architects - strathfield · gk gk 12679-11 a122 72 units + 2 commercial construction certificate...
TRANSCRIPT
UP
UP
UP
UP
UP
4
A128
3
A128
MAIN SWITCH
BOARD
MAIN
DISTRIBUTION
FRAME
SPRINKLER
VALVE & FIRE
HYDRANT
PUMP ROOM
COMMUNITY
ROOM
COMMERCIAL
GARBAGE
ROOM
BULKY STORE
ROOM
F.H
.B.
Retail C01
109 m²
Retail C02
46 m²
LOBBY RESIDENTIAL
GARBAGE
ROOM
LIFT 1
LIFT 2
F.S.4
1:8.0 1:4.0
12.55 10.00 9.75
1:8
.0
9.75
1:8.0
FAN ROOM
LOADING
DOCK
RA
MP
DO
WN
TO
B1
+RL 12.80
+RL 12.80
+RL 12.80
+RL 12.80+RL 12.80
COURTYARD AREA
REFER TO LANDSCAPE PLAN
+RL 12.80
SU
BS
TA
TIO
N
300mm KERB
LETTERBOXES TO
AUSTRALIAN STANDARDS
DEEP SOIL AREA
REFER TO LANDSCAPE PLAN
LANDSCAPED PAVED
ISLAND SAME HEIGHT AS
FOOTPATH
LEFT TURN PAVEMENT
ARROW UA3(L)
ALL TRAFFIC TURN LEFT
SIGN R2-14(L)
CONCEALED AWNING LIGHTING TO BE
BUILT IN ACCORDANCE WITH
CONDITION 13 OF THE DA CONSENT
INTERCOM SYSTEM TO AUSTRALIAN
STANDARDS
PHOENIX PALM TO BE TRANSPLANTED TO
A NEW LOCATION IN ACCORDANCE WITH
CONDITION 62 OF THE DA CONSENT
F.H.R
F.H.R
1
A126
1
A126
2
A127
2
A127
Accessible
WC
6
A601
5
A601
1.8m HIGH SECURITY GATE & DOOR IS TO
FAIL-SAFE IN THE UNLOCKED POSITION
ON THE ACTIVATION OF THE BUILDINGS
SPRINKLER & FIRE ALARM SYSTEMS
1:8.0
1:8.0
+RL 12.80
SUBSTATION EASEMENT 5.3m x 3.3m
APPROXIMATE SEWER LINE LOCATION
SUBSTATION TO ENGINEERS DETAILS &
SPECIFICATION
RAMPS TO STRUCTURAL ENGINEERS
DETAILS AND SPECIFICATION
CONCRETE IN-SITU FLOOR SLAB REFER TO
ENGINEERS DETAILS & SPECIFICATION
FIRE HYDRANTS IN ALL FIRE-
ISOLATED STAIRS
CONCRETE IN-SITU STAIRS REFER
TO STRUCTURAL ENGINEERS
DETAILS AND SPECIFICATION
VERTICAL LIFT INSTALL TO
MANUFACTURERS DETAIL AND
SPECIFICATION
METER ROOM REFER TO CONSULTANCY
DRAWINGS AND FURTHER DETAILS
MECHANICAL SHAFTS AND DUCTS REFER
TO MECHANICAL ENGINEERS DETAILS
AND SPECIFICATION
4.0m WIDE BY 4.0m HIGH SUBSTATION RIGHT OF WAY ACCESS
2.0m WIDE OVERLAPPING CABLE EASEMENT
6x125mm CONDUITS ENCASED IN 150mm CONCRETE ON ALL SIDES
CURTAIN WALL TO
MANUFACTURERS
DETAIL &
SPECIFICATION
COMBINED FIRE HYDRANT &
SPRINKLER BOOSTER TO
ENGINEERS DETAILS &
SPECIFICATION
FOOTPATH TO BE
BUILT IN
ACCORDANCE WITH
CONDITION 68 OF
THE DA CONSENT
1:40.0
F.S.2
CARETAKER
FIRE
CONTROL
CENTRE
F.H.R
W.M
F.H
F.H.R
PA
RR
AM
ATT
A R
D
STA
IR P
RE
SS
.
FA
N R
OO
M
GA
S M
ETE
R R
OO
M
7
A601
F.S.1
+RL 12.80
+RL 12.80F.S.2
F.S.3
850mm
clear
850mm
clear
850mm
clear
850mm
clear 850mm
clear (each)
850mm
clear
850mm
clear
850mm
clear
850mm
clear
850mm
clear
850mm
clear
+RL 12.80
ROLLER SHUTTER WITH
SWING DOOR
+R
L 1
2.8
0
F.I.P.
12.7512.80
12.52
12.80
850mm
clear
2x660 BIN LINEAR WITH
COMPACTOR & GARBAGE CHUTE
TO MANUFACTURERS DETAIL AND
SPECIFICATION
EXTERNAL WALLS, INTERNAL
WALLS, FLOORS & CEILINGS IN
COMMERCIAL AREAS REQUIRE
INSULATION REFER TO
SECTION-J REPORT
+RL 12.80
1:14.012.52 12.80
clear
ø 1500
12.52
850mm
clear
12.80
N
PROJECT
CLIENT
TITLE
DRAWN
DATE
DWG No
CHECKED
SCALE
architects p +61 2 9797 1599 f +61 2 9797 1533
330a Parramatta Rd HOMEBUSH WEST
NSW 2140
DO NOT SCALE. USE FIGURED DIMENSIONS IN PREFERENCE TO SCALED, CHECK ALL DIMENSIONS ON SITE BEFORE FABRICATION.
COPYRIGHT. ALL RIGHTS RESERVED. CANNONT BE REPRODUCED OR COPIED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF GM
ARCHITECTS. ANY LICENSE EXPRESSED OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE
TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT BETWEEN GM ARCHITECTS AND THE INSTRUCTING PARTY.
A1 1 : 100
NOT FOR
CONSTRUCTION
A3 1 : 200
26/10/2017
4:05 PMHomebush Construction P/L
153 Parramatta Rd Homebush
Ground Floor
GKGK
12679-11 A107
72 Units + 2 CommercialCONSTRUCTION CERTIFICATE
Ground Floor
Issue Date Description
8 26.10.2017 S96 & CC
Ground Floor
RL 12.80
Level 1
RL 17.62
Level 2
RL 20.67
Level 3
RL 23.72
Level 4
RL 26.77
Level 5
RL 29.82
Level 6
RL 32.87
Level 7
RL 36.10
Level 8
RL 39.15
Level 9
RL 42.20
Level 10
RL 45.25
Level 11
RL 48.30
Level 12
RL 51.35
Level 13
RL 54.40
Level 14
RL 57.45
Basement 1
RL 9.10
Basement 2
RL 6.10
Basement 3
RL 3.10
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
3050
3050
3050
3050
3050
3050
3050
3230
3050
3050
3050
3050
3050
4820
3700
3000
3000
1 1
5
6
7
68 8 8
6 6
1
6
1
5
7
11
5 5
7 71 1
5 55 5
2 2
2 2
2
8
4
4
7
4
4
4
6
5 5
5 5
4
7
4
4
4
6
7 7
2
2
2
2
2
2 2
2
2
2 2
2
2
2
2
2
2
2
2
2
3 3
3 3
8 8
8
PROVIDE GLAZING STRIPS TO ALL FULLY
GLAZED AREAS ON THE GROUND FLOOR LEVEL
5
8
5
5
RL 59.12 Lift Overun
PROJECT
CLIENT
TITLE
DRAWN
DATE
DWG No
CHECKED
SCALE
architects p +61 2 9797 1599 f +61 2 9797 1533
330a Parramatta Rd HOMEBUSH WEST
NSW 2140
DO NOT SCALE. USE FIGURED DIMENSIONS IN PREFERENCE TO SCALED, CHECK ALL DIMENSIONS ON SITE BEFORE FABRICATION.
COPYRIGHT. ALL RIGHTS RESERVED. CANNONT BE REPRODUCED OR COPIED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF GM
ARCHITECTS. ANY LICENSE EXPRESSED OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE
TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT BETWEEN GM ARCHITECTS AND THE INSTRUCTING PARTY.
A1 1 : 100
NOT FOR
CONSTRUCTION
A3 1 : 200
26/10/2017
4:01 PMHomebush Construction P/L
153 Parramatta Rd Homebush
Elevations
GKGK
12679-11 A122
72 Units + 2 CommercialCONSTRUCTION CERTIFICATE
Elevations South Elevation Parramatta Rd
Key Finishes
1 Vitracore G2 Cladding - Zinc Light 5790
2 Vitracore G2 Cladding - Bright Yellow 1140
3 Vitracore G2 Cladding - Zinc Dark 5220
4 Vitracore G2 Cladding - Classic Beige 1310
5 Rendered & Painted - Bristol South Pole P201-N1
6 Aluminium Windows & Doors - Powder Coated Dulux
Electro Black Ace Flat 9069116F
7 Balustrades - Frosted Glass
8 Rendered & Painted - Bristol Heather Ashes P202-N3
Issue Date Description
8 26.10.2017 S96 & CC
Ground Floor
RL 12.80
Level 1
RL 17.62
Level 2
RL 20.67
Level 3
RL 23.72
Level 4
RL 26.77
Level 5
RL 29.82
Level 6
RL 32.87
Level 7
RL 36.10
Level 8
RL 39.15
Level 9
RL 42.20
Level 10
RL 45.25
Level 11
RL 48.30
Level 12
RL 51.35
Level 13
RL 54.40
Level 14
RL 57.45
Basement 1
RL 9.10
Basement 2
RL 6.10
Basement 3
RL 3.10
3050
3050
3050
3050
3050
3050
3050
3230
3050
3050
3050
3050
3050
4820
3700
3000
3000
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
5
7
8
8 8
6
5
8
5
8
5
5
5
5
7
8
8
8
8
6 6 6
5
5
5
5
7
5
8
6
5
5
7
3 3
3 3
7
6
5
5
8
8
7
6
5
5
6 6
7
6 6
7
88
83 3
5 5 5 5 5
66
8 8
RL 59.12 Lift Overun
PROJECT
CLIENT
TITLE
DRAWN
DATE
DWG No
CHECKED
SCALE
architects p +61 2 9797 1599 f +61 2 9797 1533
330a Parramatta Rd HOMEBUSH WEST
NSW 2140
DO NOT SCALE. USE FIGURED DIMENSIONS IN PREFERENCE TO SCALED, CHECK ALL DIMENSIONS ON SITE BEFORE FABRICATION.
COPYRIGHT. ALL RIGHTS RESERVED. CANNONT BE REPRODUCED OR COPIED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF GM
ARCHITECTS. ANY LICENSE EXPRESSED OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE
TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT BETWEEN GM ARCHITECTS AND THE INSTRUCTING PARTY.
A1 1 : 100
NOT FOR
CONSTRUCTION
A3 1 : 200
26/10/2017
4:01 PMHomebush Construction P/L
153 Parramatta Rd Homebush
Elevations
GKGK
12679-11 A123
72 Units + 2 CommercialCONSTRUCTION CERTIFICATE
ElevationsNorth Elevation
Key Finishes
1 Vitracore G2 Cladding - Zinc Light 5790
2 Vitracore G2 Cladding - Bright Yellow 1140
3 Vitracore G2 Cladding - Zinc Dark 5220
4 Vitracore G2 Cladding - Classic Beige 1310
5 Rendered & Painted - Bristol South Pole P201-N1
6 Aluminium Windows & Doors - Powder Coated Dulux
Electro Black Ace Flat 9069116F
7 Balustrades - Frosted Glass
8 Rendered & Painted - Bristol Heather Ashes P202-N3
Issue Date Description
8 26.10.2017 S96 & CC
Ground Floor
RL 12.80
Level 1
RL 17.62
Level 2
RL 20.67
Level 3
RL 23.72
Level 4
RL 26.77
Level 5
RL 29.82
Level 6
RL 32.87
Level 7
RL 36.10
Level 8
RL 39.15
Level 9
RL 42.20
Level 10
RL 45.25
Level 11
RL 48.30
Level 12
RL 51.35
Level 13
RL 54.40
Level 14
RL 57.45
Basement 1
RL 9.10
Basement 2
RL 6.10
Basement 3
RL 3.10
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
3050
3050
3050
3050
3050
3050
3050
3230
3050
3050
3050
3050
3050
4820
3700
3000
3000
8
8 8
8
5
5
5
6
7
6 6
7
4
4
4
4
4
4
4
3
3
8 8
8
3
3
33 3
3 3
2
2
5
5
5
5
6
57
5
5
6
5
4
4
4
RL 59.12 Lift Overun
PROJECT
CLIENT
TITLE
DRAWN
DATE
DWG No
CHECKED
SCALE
architects p +61 2 9797 1599 f +61 2 9797 1533
330a Parramatta Rd HOMEBUSH WEST
NSW 2140
DO NOT SCALE. USE FIGURED DIMENSIONS IN PREFERENCE TO SCALED, CHECK ALL DIMENSIONS ON SITE BEFORE FABRICATION.
COPYRIGHT. ALL RIGHTS RESERVED. CANNONT BE REPRODUCED OR COPIED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF GM
ARCHITECTS. ANY LICENSE EXPRESSED OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE
TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT BETWEEN GM ARCHITECTS AND THE INSTRUCTING PARTY.
A1 1 : 100
NOT FOR
CONSTRUCTION
A3 1 : 200
26/10/2017
4:01 PMHomebush Construction P/L
153 Parramatta Rd Homebush
Elevations
GKGK
12679-11 A124
72 Units + 2 CommercialCONSTRUCTION CERTIFICATE
ElevationsEast Elevation
Key Finishes
1 Vitracore G2 Cladding - Zinc Light 5790
2 Vitracore G2 Cladding - Bright Yellow 1140
3 Vitracore G2 Cladding - Zinc Dark 5220
4 Vitracore G2 Cladding - Classic Beige 1310
5 Rendered & Painted - Bristol South Pole P201-N1
6 Aluminium Windows & Doors - Powder Coated Dulux
Electro Black Ace Flat 9069116F
7 Balustrades - Frosted Glass
8 Rendered & Painted - Bristol Heather Ashes P202-N3
Issue Date Description
8 26.10.2017 S96 & CC
Ground Floor
RL 12.80
Level 1
RL 17.62
Level 2
RL 20.67
Level 3
RL 23.72
Level 4
RL 26.77
Level 5
RL 29.82
Level 6
RL 32.87
Level 7
RL 36.10
Level 8
RL 39.15
Level 9
RL 42.20
Level 10
RL 45.25
Level 11
RL 48.30
Level 12
RL 51.35
Level 13
RL 54.40
Level 14
RL 57.45
Basement 1
RL 9.10
Basement 2
RL 6.10
Basement 3
RL 3.10
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
3050
3050
3050
3050
3050
3050
3050
3230
3050
3050
3050
3050
3050
4820
3700
3000
3000
8
8
5
8
6
5
5
5
5
5
6
5
3
5
3 8
8
6
7
3 3
4
8
3 3 8
4
44
3
4
4
3 3
7
6
2
2
4
5
7
2
6
5
5
5
4
4
RL 59.12 Lift Overun
PROJECT
CLIENT
TITLE
DRAWN
DATE
DWG No
CHECKED
SCALE
architects p +61 2 9797 1599 f +61 2 9797 1533
330a Parramatta Rd HOMEBUSH WEST
NSW 2140
DO NOT SCALE. USE FIGURED DIMENSIONS IN PREFERENCE TO SCALED, CHECK ALL DIMENSIONS ON SITE BEFORE FABRICATION.
COPYRIGHT. ALL RIGHTS RESERVED. CANNONT BE REPRODUCED OR COPIED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF GM
ARCHITECTS. ANY LICENSE EXPRESSED OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE
TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT BETWEEN GM ARCHITECTS AND THE INSTRUCTING PARTY.
A1 1 : 100
NOT FOR
CONSTRUCTION
A3 1 : 200
26/10/2017
4:01 PMHomebush Construction P/L
153 Parramatta Rd Homebush
Elevations
GKGK
12679-11 A125
72 Units + 2 CommercialCONSTRUCTION CERTIFICATE
ElevationsWest Elevation
Key Finishes
1 Vitracore G2 Cladding - Zinc Light 5790
2 Vitracore G2 Cladding - Bright Yellow 1140
3 Vitracore G2 Cladding - Zinc Dark 5220
4 Vitracore G2 Cladding - Classic Beige 1310
5 Rendered & Painted - Bristol South Pole P201-N1
6 Aluminium Windows & Doors - Powder Coated Dulux
Electro Black Ace Flat 9069116F
7 Balustrades - Frosted Glass
8 Rendered & Painted - Bristol Heather Ashes P202-N3
Issue Date Description
8 26.10.2017 S96 & CC
N
PROJECT
CLIENT
TITLE
DRAWN
DATE
DWG No
CHECKED
SCALE
architects p +61 2 9797 1599 f +61 2 9797 1533
330a Parramatta Rd HOMEBUSH WEST
NSW 2140
DO NOT SCALE. USE FIGURED DIMENSIONS IN PREFERENCE TO SCALED, CHECK ALL DIMENSIONS ON SITE BEFORE FABRICATION.
COPYRIGHT. ALL RIGHTS RESERVED. CANNONT BE REPRODUCED OR COPIED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF GM
ARCHITECTS. ANY LICENSE EXPRESSED OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE
TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT BETWEEN GM ARCHITECTS AND THE INSTRUCTING PARTY.
NOT FOR
CONSTRUCTION
A3 1 : 1000
26/10/2017
4:02 PMHomebush Construction P/L
153 Parramatta Rd Homebush
Shadows
GKGK
12679-11 A700
72 Units + 2 CommercialCONSTRUCTION CERTIFICATE
Shadows
A1 1 : 500
Shadows 21st June 9am Shadows 21st June 10am
Shadows 21st June 11am Shadows 21st June 12pm
Issue Date Description
8 26.10.2017 S96 & CC
DA APPROVED SHADOW OUTLINE
N
PROJECT
CLIENT
TITLE
DRAWN
DATE
DWG No
CHECKED
SCALE
architects p +61 2 9797 1599 f +61 2 9797 1533
330a Parramatta Rd HOMEBUSH WEST
NSW 2140
DO NOT SCALE. USE FIGURED DIMENSIONS IN PREFERENCE TO SCALED, CHECK ALL DIMENSIONS ON SITE BEFORE FABRICATION.
COPYRIGHT. ALL RIGHTS RESERVED. CANNONT BE REPRODUCED OR COPIED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF GM
ARCHITECTS. ANY LICENSE EXPRESSED OR IMPLIED, TO USE THIS DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE
TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT BETWEEN GM ARCHITECTS AND THE INSTRUCTING PARTY.
NOT FOR
CONSTRUCTION
A3 1 : 1000
26/10/2017
4:02 PMHomebush Construction P/L
153 Parramatta Rd Homebush
Shadows
GKGK
12679-11 A701
72 Units + 2 CommercialCONSTRUCTION CERTIFICATE
Shadows
A1 1 : 500
Issue Date Description
8 26.10.2017 S96 & CC
Shadows 21st June 1pm
Shadows 21st June 2pm
Shadows 21st June 3pm
DA APPROVED SHADOW OUTLINE