arcitectural door accessories.pdfdoor accessories required tools: • 12mm wrench • 7/16"...

4
Copyright © 2018, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited. 81050 11/18 Pemko Soft Close Device For Box Track Hardware System Architectural Door Accessories Required Tools: • 12mm Wrench • 7/16" Wrench • Level • 1/8" Hex Key 1. Remove door. Remove fascia and end caps if applicable. Measure and record the clearance or gap from bottom of track to top edge of door. This will be important later. Remove in track stops. Remove door from track by sliding door off of one end of track. Remove hanger from mounting bracket using WRENCH14 (provided) and 12mm wrench (not provided). Door can also be removed by loosening nuts on hanger using WRENCH14 (provided) and 12mm wrench (not provided). Unhook door from hangers as shown. NOTE: Move door past door guide before unhooking door. Works with Pemko Systems: H180 SHS80 H200 280_SWTKIT SF280_SWTK RF280SWTK HBP200 Part Number Description SC1411-1 Single Device 88-132 lbs SC1411-2 Dual Device 88-132 lbs SC1413-1 Single Device 133-176 lbs SC1413-2 Dual Device 133-176 lbs SC1418-1 Single Device 177-200 lbs SC1418-2 Dual Device 177-200 lbs Minimum Door Width 28" WARNING: DO NOT LEAVE DOOR UNATTENDED AT ANY POINT DURING INSTALLATION! For easy 3D instructions, download the BILT mobile app available on the App Store or Google Play.

Upload: others

Post on 08-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Arcitectural Door Accessories.pdfDoor Accessories Required Tools: • 12mm Wrench • 7/16" Wrench • Level • 1/8" Hex Key 1. Remove door. Remove fascia and end caps if applicable

Copyright © 2018, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole orin part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited. 81050 11/18

Pemko Soft Close DeviceFor Box Track Hardware System

Architectural Door Accessories

Required Tools:• 12mm Wrench • 7/16" Wrench • Level • 1/8" Hex Key

1. Remove door.Remove fascia and end caps if applicable.

Measure and record the clearance or gap from bottom of track to top edge of door. This will be important later.

Remove in track stops.

Remove door from track by sliding door off of one end of track.

Remove hanger from mounting bracket using WRENCH14 (provided) and 12mm wrench (not provided).

Door can also be removed by loosening nuts on hanger using WRENCH14 (provided) and 12mm wrench (not provided).

Unhook door from hangers as shown.

NOTE: Move door past door guide before unhooking door.

Works with Pemko Systems:H180SHS80H200280_SWTKITSF280_SWTKRF280SWTKHBP200

Part Number Description

SC1411-1 Single Device 88-132 lbs

SC1411-2 Dual Device 88-132 lbs

SC1413-1 Single Device 133-176 lbs

SC1413-2 Dual Device 133-176 lbs

SC1418-1 Single Device 177-200 lbs

SC1418-2 Dual Device 177-200 lbs

Minimum Door Width 28"

WARNING: DO NOT LEAVE DOOR UNATTENDED AT ANY POINT DURING INSTALLATION!For easy 3D instructions, download the BILT mobile app available on the App Store or Google Play.

Page 2: Arcitectural Door Accessories.pdfDoor Accessories Required Tools: • 12mm Wrench • 7/16" Wrench • Level • 1/8" Hex Key 1. Remove door. Remove fascia and end caps if applicable

Copyright © 2018, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole orin part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited. 281050 11/18

4a. Position soft close damper(s).Locate soft close damper(s) on top door edge. Pay special attention to damper orientation as shown. Catches are installed toward center of door.

Damper mounted on left side of door must face front of door. Damper on right side of door must face back of door as shown.

System may come with only one damper.

3. Activate devices.Slide catch towards center of device as shown.

2. Replace hanger bolts.Remove hanger bolt and replace it with taller hanger bolt provided as shown.

4b. Mark and pre-drill holes for damper(s). Predrill 1/8" x 2" for #10 x 2" wood screws (provided).

9/16"(14mm)

5"(127mm)

Front Face of Door

Back Face of Door

7-7/16"(189mm)

X 2" (51mm)Deep

1/8"

9/16"(14mm)

5"(127mm)

Front Face of Door

Back Face of Door

7-7/16"(189mm)

X 2" (51mm)Deep

1/8"

Catch

Catch

Device on LEFT faces front of door.

Device on RIGHT faces back of door.Catch

Catch

Taller Hanger Bolt

Page 3: Arcitectural Door Accessories.pdfDoor Accessories Required Tools: • 12mm Wrench • 7/16" Wrench • Level • 1/8" Hex Key 1. Remove door. Remove fascia and end caps if applicable

Copyright © 2018, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole orin part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited. 381050 11/18

6. Choose activator pin.Choose appropriate activator pin by using recorded clearance information you gathered in step one and chart in this step.

Clearance Activator Pin

1" to 1-1/4" Short Pin

1-5/16" to 1-3/8" Long Pin

Clearance

5. Hang door and adjust until level.

Slide door into open end of track or hook door to hangers as shown.

Adjust until level.

Level

4c. Install damper(s) with spacers.Insert spacers (provided) between mounting tabs on dampers as shown.

Attach damper to top door edge using #10 x 2" wood screws.

7. Install activator pin.Install appropriate activator pin on end of rod as shown using 5/64" hex wrench (provided).

Short Pin

Long Pin

Page 4: Arcitectural Door Accessories.pdfDoor Accessories Required Tools: • 12mm Wrench • 7/16" Wrench • Level • 1/8" Hex Key 1. Remove door. Remove fascia and end caps if applicable

81050 11/18Copyright © 2018, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole orin part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.

Memphis, TN 38141Phone: 800.824.3018

USA:Ventura, CA 93003Phone: 800.283.9988

Canada:Vancouver, BC V2T6W3Phone: 877.535.7888

Toronto, ON L4K4T9Phone: 877.535.7888

www.assaabloydooraccessories.us

14"(35.5cm)

10. Reinstall fascia and end caps.Apply foam tape to fascia 14" in from door edge to edge of foam as shown if applicable.

Apply second foam tape to wall 14" in from opposite end of track edge to edge of foam as shown if applicable.

Reinstall fascia and end caps.

9. Align activator.

Move door to open/closed position.

Adjust activator assembly location as needed.

Ensure proper engagement between activator pin and soft close damper.

8. Install activator assembly into track.Install activator assembly into track as shown.

Be sure that activator pin is pointing towards center of track.

Ensure bottom base portion of activator is in line with door edge when door is in open/closed position as shown.

Tighten two hex bolts in bottom base of activator assembly using 7/16" wrench (not provided).

Tighten two screws in bottom base of activator assembly using 1/8" hex key (not provided).

Activator PinD

oor

Edge

Screws and Hex Bolts

Activator Pin

Damper

Foam Tapeon Fascia Foam Tape

on Wall

Door Edge

Track Edge14"