Lucid Arena | V1.1 • Page 1 Installations and Service Guide Installation and Service Guide | V1.1 Lucid arena | LED lamp Read these instructions before installing the device, putting it into operation, storage or handling it in any other manner This Installation and Service Instructions, Edition 01-2010 is, for the LED lighting arena Lucid 60 ° / 120 ° IP66

Upload: andrei-daniel

Post on 27-Dec-2014

27 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Arena 1 1 Service Guide

Lucid Arena | V1.1 • Page 1 Installations and Service Guide

Installation and Service Guide | V1.1

Lucid arena | LED lamp

Read these instructions before installing the device, putting it into operation, storage or handling it in any other manner

This Installation and Service Instructions, Edition 01-2010 is, for the LED lighting arena Lucid 60 ° / 120 °

IP66

Page 2: Arena 1 1 Service Guide

Lucid Arena | V1.1 • Page 3 Installations and Service Guide Page 2 • Lucid Arena | V1.1 Installations and Service Guide

Introduction

Intended Application

electrical engineering technicians.

LEiDs GmbH & Co. KGDonaustr. 22-2471522 BacknangGermanyPhone +49 7191 323020Telefax +49 7191 323029Email:

EU-Directives

Name plate

This installation and service manual is for people (Electricians, service technicians), which are responsible for the installation and maintenance of the LED light "Lucid arena”. These people must be familiar with all the relevant electrical regulations and adhere to them in all cases. This guide is not suitable for users without special knowledge.

The LED light series „Lucid arena“ is a luminaire for professional use in industrial buildings and outdoor applications. They are used to illumination of work, storage, corridors and footpaths.

The installation and maintenance of the device is reserved exclusively for

For questions about the handling of the lights that are not answered in this manual, please contact us at:

LED lamp series Lucid arena was approved by the German Certification body VDE and satisfies the requirements of the European Union Directives.

For precise identification, you will find information on model / item number on the nameplate of the lamp. Write down this information when you have questions or when spare parts need to be ordered.

[email protected]

Safety Precautions

Risk of elecrticity

– –

Installation•

• Connect the „power supply“ (transformer) to the appropriate power source from the mains supply.• Use only the integrated „power supply“ to supply power to the lamp. • Unplug the lamp from the mains and from any other device if a malfunction occurs. • Do not open the Lucid Arena as a replacement of the light source is not planned and is not provided! • Make sure, that only qualified personnel (electricians) are responsible for installation and maintenance of the lamp. • If the safe operation of a device is not ensured according to the safety regulations. Then you should turn off the lamp and ensure that no accidental operation of the lamp is possible.

Safe operation is for example no longer possible, if the lamp power supply or cables are visibly damaged if foreign materials have entered into the lamp.

Please note: A terminal clamp is not in the scope of supply of the lamp. Please use an adequate terminal clamp that corresponds to the safety standard for installation.

The installation steps described in this manual should only be carried out by trained personnel. And should be carried out, according to the local electrical safety standards. • Perform only the maintenance work described in this manual. Any further attempts to repair or adjustment of the lamp could lead to physical injury, property damage and damage to the lamp. • For all work carried out on ceilings, high poles or any other high mounted lamps, the adequate safety ladders or the appropriate installation machinery should be used in accordance with the safety standards.• If necessary a safety net should be mounted.

Page 3: Arena 1 1 Service Guide

Lucid Arena | V1.1 • Page 3 Installations and Service Guide Page 2 • Lucid Arena | V1.1 Installations and Service Guide

Introduction

Intended Application

electrical engineering technicians.

LEiDs GmbH & Co. KGDonaustr. 22-2471522 BacknangGermanyPhone +49 7191 323020Telefax +49 7191 323029Email:

EU-Directives

Name plate

This installation and service manual is for people (Electricians, service technicians), which are responsible for the installation and maintenance of the LED light "Lucid arena”. These people must be familiar with all the relevant electrical regulations and adhere to them in all cases. This guide is not suitable for users without special knowledge.

The LED light series „Lucid arena“ is a luminaire for professional use in industrial buildings and outdoor applications. They are used to illumination of work, storage, corridors and footpaths.

The installation and maintenance of the device is reserved exclusively for

For questions about the handling of the lights that are not answered in this manual, please contact us at:

LED lamp series Lucid arena was approved by the German Certification body VDE and satisfies the requirements of the European Union Directives.

For precise identification, you will find information on model / item number on the nameplate of the lamp. Write down this information when you have questions or when spare parts need to be ordered.

[email protected]

Safety Precautions

Risk of elecrticity

– –

Installation•

• Connect the „power supply“ (transformer) to the appropriate power source from the mains supply.• Use only the integrated „power supply“ to supply power to the lamp. • Unplug the lamp from the mains and from any other device if a malfunction occurs. • Do not open the Lucid Arena as a replacement of the light source is not planned and is not provided! • Make sure, that only qualified personnel (electricians) are responsible for installation and maintenance of the lamp. • If the safe operation of a device is not ensured according to the safety regulations. Then you should turn off the lamp and ensure that no accidental operation of the lamp is possible.

Safe operation is for example no longer possible, if the lamp power supply or cables are visibly damaged if foreign materials have entered into the lamp.

Please note: A terminal clamp is not in the scope of supply of the lamp. Please use an adequate terminal clamp that corresponds to the safety standard for installation.

The installation steps described in this manual should only be carried out by trained personnel. And should be carried out, according to the local electrical safety standards. • Perform only the maintenance work described in this manual. Any further attempts to repair or adjustment of the lamp could lead to physical injury, property damage and damage to the lamp. • For all work carried out on ceilings, high poles or any other high mounted lamps, the adequate safety ladders or the appropriate installation machinery should be used in accordance with the safety standards.• If necessary a safety net should be mounted.

Page 4: Arena 1 1 Service Guide

Lucid Arena | V1.1 • Page 5 Installations and Service Guide Page 4 • Lucid Arena | V1.1 Installations and Service Guide

Production Description

Models

Luminous

Pre-assembly

Temperature control point (tc)

The LED lamp series “Lucid arena” comes complete with matching power supply for driving the light source. The connection of the lamp is done via a 3-wire jacketed connection cable that suits the operation demands of the lamp. The series “Lucid arena” are maintenance free. All lamps can be mounted with the bracket construction, which allows for mounting on walls and ceilings. The reliable “Lucid arena” lamp has an average life span of 60,000 hours.

The luminosity of the model Lucid arena compares to a 500 watt Halogen flood light, but at a significantly lower power consumption. The lamp is designed for applications in warehouses and commercial properties.

After unpacking the lamp , the screws of the bracket clamp should be loosened with an “Allen key” 5mm and the bracket should be placed in vertical position. Please make sure that the cable is not pinched between the bracket and heat sinks. Tighten the screws securely when the bracket is vertical.

The maximum temperature of 80 ° C may not be exceeded at the mark shown on the picture. By complying with the maximum temperature control at the tc point, this ensures that no components over heat and effect the performance of the lamp. At high temperatures sufficient cooling should be provided. In case this temperature are reached the lamp has to be cut-off from the power immediately.

Installation•

Cleaning - Maintenance- Information•

Technical data

100 V - 240V 24V constant current 3,85A

24V direct current -30° to +50°

IIP 66

1120 leds / ALDER AS-3528WCA2 100 Watt

app. 5,8 kg / app. 500 gDimensions LxBxH 322 x 220 x 160mm

LED light should be mounted horizontally at the desired position.• Minimum of 2 mounting-screws with a diameter of 6mm should be used for the mounting of the mounting bracket on the surface(wall/ceiling).• The power connection is via a 1m long flexible cable.The cable has loose ends and must have an additional terminal box (not included). If necessary, the cable ends should be safe guarded with ferrules.• The „earthing“ of the lamp is done via the green and yellow cable. • When the ideal angle of orientation of the LED lamp has been approved, all screws should be tightened and should be checked at least once a year, and if necessary tightened again. • When adjusting the LED light, precaution should be taken, that no damage is done to the power cable.

All parts of the device are maintenance free.• Use only with supplied „power supply“! • The LED module should not be opened! • For cleaning we recommend a damp cloth. • No cleaning agents should be used. • Damaged cable should be replaced immediately with new cable.

Power supply voltage inputPower supply voltage outputOperating voltage for module LEDPermitted ambient TempProtection ClassType of ProtectionNo. of LEDs/TypeTotal power consumptionTotal Weight / Light field

Bracket in packing position Bracket in vertical position

Item-no. Colour

Temperature

Angle of

Radiation

Luminous flux

(Lumen)

Light intensity

(Candela)18010 cold whi te 120° 8050 lm 256218013 cold whi te 60° 7645 lm 908018020 dayl ight whi te 120° 8050 lm 256218023 dayl ight whi te 60° 7645 lm 908018030 normal whi te 120° 8050 lm 256218033 normal whi te 60° 7645 lm 908018040 warm white 120° 7245 lm 230618043 warm white 60° 6880 lm 8170

Temperature control point (tc)

Page 5: Arena 1 1 Service Guide

Lucid Arena | V1.1 • Page 5 Installations and Service Guide Page 4 • Lucid Arena | V1.1 Installations and Service Guide

Production Description

Models

Luminous

Pre-assembly

Temperature control point (tc)

The LED lamp series “Lucid arena” comes complete with matching power supply for driving the light source. The connection of the lamp is done via a 3-wire jacketed connection cable that suits the operation demands of the lamp. The series “Lucid arena” are maintenance free. All lamps can be mounted with the bracket construction, which allows for mounting on walls and ceilings. The reliable “Lucid arena” lamp has an average life span of 60,000 hours.

The luminosity of the model Lucid arena compares to a 500 watt Halogen flood light, but at a significantly lower power consumption. The lamp is designed for applications in warehouses and commercial properties.

After unpacking the lamp , the screws of the bracket clamp should be loosened with an “Allen key” 5mm and the bracket should be placed in vertical position. Please make sure that the cable is not pinched between the bracket and heat sinks. Tighten the screws securely when the bracket is vertical.

The maximum temperature of 80 ° C may not be exceeded at the mark shown on the picture. By complying with the maximum temperature control at the tc point, this ensures that no components over heat and effect the performance of the lamp. At high temperatures sufficient cooling should be provided. In case this temperature are reached the lamp has to be cut-off from the power immediately.

Installation•

Cleaning - Maintenance- Information•

Technical data

100 V - 240V 24V constant current 3,85A

24V direct current -30° to +50°

IIP 66

1120 leds / ALDER AS-3528WCA2 100 Watt

app. 5,8 kg / app. 500 gDimensions LxBxH 322 x 220 x 160mm

LED light should be mounted horizontally at the desired position.• Minimum of 2 mounting-screws with a diameter of 6mm should be used for the mounting of the mounting bracket on the surface(wall/ceiling).• The power connection is via a 1m long flexible cable.The cable has loose ends and must have an additional terminal box (not included). If necessary, the cable ends should be safe guarded with ferrules.• The „earthing“ of the lamp is done via the green and yellow cable. • When the ideal angle of orientation of the LED lamp has been approved, all screws should be tightened and should be checked at least once a year, and if necessary tightened again. • When adjusting the LED light, precaution should be taken, that no damage is done to the power cable.

All parts of the device are maintenance free.• Use only with supplied „power supply“! • The LED module should not be opened! • For cleaning we recommend a damp cloth. • No cleaning agents should be used. • Damaged cable should be replaced immediately with new cable.

Power supply voltage inputPower supply voltage outputOperating voltage for module LEDPermitted ambient TempProtection ClassType of ProtectionNo. of LEDs/TypeTotal power consumptionTotal Weight / Light field

Bracket in packing position Bracket in vertical position

Item-no. Colour

Temperature

Angle of

Radiation

Luminous flux

(Lumen)

Light intensity

(Candela)18010 cold whi te 120° 8050 lm 256218013 cold whi te 60° 7645 lm 908018020 dayl ight whi te 120° 8050 lm 256218023 dayl ight whi te 60° 7645 lm 908018030 normal whi te 120° 8050 lm 256218033 normal whi te 60° 7645 lm 908018040 warm white 120° 7245 lm 230618043 warm white 60° 6880 lm 8170

Temperature control point (tc)

Page 6: Arena 1 1 Service Guide

Lucid Arena | V1.1 • Page 7 Installations and Service Guide Page 6 • Lucid Arena | V1.1 Installations and Service Guide

Warrenty

1.

2.

3.4.

5.

6.

7.

The warranty is valid for 2 years, unless an additional warranty extension was agreed at the time of purchase. The warranty extension is an additional service with a cost factor.The warranty starts on the date of delivery to the end customer.To assert a warranty claim, the purchase receipt showing date of delivery and date of purchase has to be submitted. When warranty claim is filed, the defective unit has to be returned to your dealer or directly to: LEiDs GmbH & Co.KG, Donau Str. 22-24, D-71522 Backnang, Email: [email protected] warranty covers all material and construction errors.The warranty excludes all the errors and defects occurring due to the following points:

a) Not following the instruction manual.b) Natural wear and tear.c) External influences for example, transport damage, damage due to shock impact, overheating, damage caused by chemicals, damage caused by electrochemical reactions, eg. trough water, acids and improper use. d) Repairing and modification done by unauthorized personal.e) Use of inappropriate accessories.f) Furthermore, excluded are: Damage caused by improper handling, incorrect installation and improper maintenance (see installation instruction), damage due to force majeure, fire, vandalism and any further accidents

Within the warranty period. LEiDs will eliminate any errors that occur, this will be done after consultation with the dealer. The malfunctioning parts will be repaired or replaced. Exchanged parts will automatically become the property of LEiDs GmbH& Co.KG. Further claims, of whatever kind, in particular claims for financial damages are not included.

:a) Costs for demounting and remounting of the lamp.b) Costs for sending the defect lamp to LEiDs.

LEiDS LED-Lamps are subject to continuous development according to the technical development of the LEDs and Power Supply. For this reason, in case of a warranty repair claim, the situation could arise that the original parts or the original lamp is no longer available, in such cases LEiDs reserves the right to provide parts or lamps that for fill the same function or provide parts and lamps that perform better then the originals.LEiDs, legally reserves the rights to change the warranty period, the fixed price conditions without any prior notice.Warranties, with valid registration are not effected, when the new amendments are introduced. LEiDs reserve the legal rights to make the final decision if a warranty case is valid or not.

Excluded from the guarantee

Legal Notice

This manual contains the necessary legal information explaining how to use the LEiDs LED Lamp.Understanding and following the instructions in this manual are a prerequisite for the safe implementation and operation of the lamp. This manual does not and cannot cover all conceivable applications. The LED lamp is designed for indoor, in sheltered out door areas and outdoor areas. Further more we would like to point out this manual is not a part of any prior or existing legal agreement or commitment or any other legal relationship.The manual contains information that is protected by copyright. Photocopying or translation into any other language is not allowed without the prior written consent of LEiDs Germany. This manual is containing the necessary information for the intended use.

LEiDs LED-lamps are subject to the continuous improvement due to the continuous developments in the LED industry.

Page 7: Arena 1 1 Service Guide

Lucid Arena | V1.1 • Page 7 Installations and Service Guide Page 6 • Lucid Arena | V1.1 Installations and Service Guide

Warrenty

1.

2.

3.4.

5.

6.

7.

The warranty is valid for 2 years, unless an additional warranty extension was agreed at the time of purchase. The warranty extension is an additional service with a cost factor.The warranty starts on the date of delivery to the end customer.To assert a warranty claim, the purchase receipt showing date of delivery and date of purchase has to be submitted. When warranty claim is filed, the defective unit has to be returned to your dealer or directly to: LEiDs GmbH & Co.KG, Donau Str. 22-24, D-71522 Backnang, Email: [email protected] warranty covers all material and construction errors.The warranty excludes all the errors and defects occurring due to the following points:

a) Not following the instruction manual.b) Natural wear and tear.c) External influences for example, transport damage, damage due to shock impact, overheating, damage caused by chemicals, damage caused by electrochemical reactions, eg. trough water, acids and improper use. d) Repairing and modification done by unauthorized personal.e) Use of inappropriate accessories.f) Furthermore, excluded are: Damage caused by improper handling, incorrect installation and improper maintenance (see installation instruction), damage due to force majeure, fire, vandalism and any further accidents

Within the warranty period. LEiDs will eliminate any errors that occur, this will be done after consultation with the dealer. The malfunctioning parts will be repaired or replaced. Exchanged parts will automatically become the property of LEiDs GmbH& Co.KG. Further claims, of whatever kind, in particular claims for financial damages are not included.

:a) Costs for demounting and remounting of the lamp.b) Costs for sending the defect lamp to LEiDs.

LEiDS LED-Lamps are subject to continuous development according to the technical development of the LEDs and Power Supply. For this reason, in case of a warranty repair claim, the situation could arise that the original parts or the original lamp is no longer available, in such cases LEiDs reserves the right to provide parts or lamps that for fill the same function or provide parts and lamps that perform better then the originals.LEiDs, legally reserves the rights to change the warranty period, the fixed price conditions without any prior notice.Warranties, with valid registration are not effected, when the new amendments are introduced. LEiDs reserve the legal rights to make the final decision if a warranty case is valid or not.

Excluded from the guarantee

Legal Notice

This manual contains the necessary legal information explaining how to use the LEiDs LED Lamp.Understanding and following the instructions in this manual are a prerequisite for the safe implementation and operation of the lamp. This manual does not and cannot cover all conceivable applications. The LED lamp is designed for indoor, in sheltered out door areas and outdoor areas. Further more we would like to point out this manual is not a part of any prior or existing legal agreement or commitment or any other legal relationship.The manual contains information that is protected by copyright. Photocopying or translation into any other language is not allowed without the prior written consent of LEiDs Germany. This manual is containing the necessary information for the intended use.

LEiDs LED-lamps are subject to the continuous improvement due to the continuous developments in the LED industry.

Page 8: Arena 1 1 Service Guide

Page 8 • Lucid Arena | V1.1Installations and Service Guide