arrowhead rainscreen panel system dwg-01 elevation · dwg-01 sheet project number drawn by no no...

22
GENERAL DETAILS 2: SYSTEM ISOMETRIC 3: ATTACHMENT EXTRUSIONS SECTION DETAILS 4: BASE 5A-B: TYPICAL VERTICAL 6: WINDOW SILL 7A-B: PARAPET 8A-B: INSIDE CORNER 9: OUTSIDE CORNER 10A. VERTICAL JAMB - START 10B. VERTICAL JAMB - END 11. TYPICAL HORIZONTAL 12. DIFFERENT DEPTH VERTICAL DETAIL 13. DIFFERENT DEPTH HORIZONTAL DETAIL 14. DIFFERENT DEPTH VERTICAL DETAIL 15. DIFFERENT DEPTH HORIZONTAL DETAIL 16. DISSIMILAR METALS - JAMB 17. DISSIMILAR METALS - SILL 18. TYPICAL SOFFIT DETAIL 19. SOFFIT TO WALL 6 14 15 13 7 5 11 12 9 10 4 8 17 16 18 19 *TESTING PERFORMED ON STANDARD SYSTEM DEPTH ONLY. INQUIRE IF ADDITIONAL TESTING IS REQUIRED. DWG-01 Sheet Project Number Drawn By No No Revisions Date Date Date Drawn NCDS Project 1 www.fairview-na.com ARROWHEAD RAINSCREEN PANEL SYSTEM 10/12/2017 ELEVATION © Copyright Fairview Architectural LLC - Patented and/or Patent Pending

Upload: others

Post on 22-Oct-2019

6 views

Category:

Documents


0 download

TRANSCRIPT

GENERAL DETAILS

2: SYSTEM ISOMETRIC3: ATTACHMENT EXTRUSIONS

SECTION DETAILS

4: BASE5A-B: TYPICAL VERTICAL6: WINDOW SILL7A-B: PARAPET8A-B: INSIDE CORNER9: OUTSIDE CORNER10A. VERTICAL JAMB - START10B. VERTICAL JAMB - END11. TYPICAL HORIZONTAL12. DIFFERENT DEPTH VERTICAL DETAIL13. DIFFERENT DEPTH HORIZONTAL DETAIL14. DIFFERENT DEPTH VERTICAL DETAIL15. DIFFERENT DEPTH HORIZONTAL DETAIL16. DISSIMILAR METALS - JAMB17. DISSIMILAR METALS - SILL18. TYPICAL SOFFIT DETAIL19. SOFFIT TO WALL

6

14

15

13

7

5

11

12

9

10

4 8

17

16

18 19

*TESTING PERFORMED ON STANDARD SYSTEM DEPTH ONLY. INQUIRE IF ADDITIONAL TESTING IS REQUIRED.

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

1www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

ELEVATION

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

2www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

SYSTEM ISOMETRIC

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

AH-107 PERIMETER CLIPAH-104 T-CLIP AH-101 FRAME

AH-204 VERTICAL CLIP

AH-203 HEAD

AH-106 STIFFENER

AH-202 BASE

AH-207 STARTER CLIP

AH-205 SILL

AH-206 END CLIP

AH-102 BASE

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

3www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

ATTACHMENT EXTRUSIONS

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

AS REQ'D

2"NOMINAL

1/4" DIA. ANCHOR(MAX. 16" O.C.)

BY OTHERS

AH-101 FRAMEEXTRUSION

SHOP ATTACHED

AH-205SILL

532" ALUMINUM

CSK RIVET@ MIN. 16" O.C.

COUNTERFLASHING

BY OTHERS

SOLID BACKERBY OTHERS

WEATHER BARRIERAPPLIED TO FACE

OF SUBSTRATEBY OTHERS

SHIM AS REQ'DBY OTHERS

5/16" WEEP HOLE & BAFFLEAT 8" FROM EACH END(℄ ON PANELS 60"-96")

4 MM VITRABONDFR CORE MCM

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

4www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

BASE DETAIL

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

12"

MIN.

218"

NOMINAL

1-3/4"

#12 X 3/8" SELFTAPPING SCREW(2) PER CLIP

OUTLINEOF SHIMBELOW

AH-101 FRAMEEXTRUSION

AH-204VERTICAL CLIP

532" ALUMINUM

CSK RIVET@ MIN. 16" O.C.

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

SHIM AS REQ'D

AH-104T-CLIP

4 MM VITRABONDFR CORE MCM

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

5Awww.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

TYPICAL VERTICAL DETAIL

OUTLINE OFAH-202

BASE BELOW

IF SELF TAPPING SCREWSPENETRATE WEATHERBARRIER, THESE LOCATIONSMUST BE SEALED

#12 X 3/4" SELF DRILLING TEKSCREWS MAY BE USED WITHEXTERIOR INSULATED WALLS

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

VARIES1" MIN.

218"

NOMINAL

#12 X 3/8" SELFTAPPING SCREW(1) PER CLIP

OUTLINEOF SHIMBELOW

AH-206END CLIP

532" ALUMINUM

CSK RIVET@ MIN. 16" O.C.

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

SHIM AS REQ'D

AH-101 FRAMEEXTRUSION

AH-207STARTER CLIP

4 MM VITRABONDFR CORE MCM

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

5Bwww.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

ALT. HORIZ/VERTICAL DETAIL

OUTLINE OFAH-202

BASE BELOW

#12 X 1/2" SELFTAPPING SCREW

(1) PER CLIP

AH-107PERIMETERCLIP

IF SELF TAPPING SCREWSPENETRATE WEATHERBARRIER, THESE LOCATIONSMUST BE SEALED

#12 X 3/4" SELF DRILLING TEKSCREWS MAY BE USED WITHEXTERIOR INSULATED WALLS

#12 X 1/2" SELFTAPPING SCREW(1) PER CLIP

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

34"

MIN.

2"NOMINAL

1/4" DIA. ANCHOR(MAX. 16" O.C.)

BY OTHERS

AH-101 FRAMEEXTRUSION

532" ALUMINUMCSK RIVET@ MIN. 16" O.C.

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

BACKER ROD& SEALANTBY OTHERS

WINDOWSYSTEMBY OTHERS

AH-203 HEADEXTRUSION

AH-107PERIMETERCLIP

COUNTERFLASHING

BY OTHERS

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

6www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

DISSIMILAR METALS

4 MMVITRABONDFR CORE MCMSHIM AS REQ'D

BY OTHERS

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

2"NOMINAL

1/4" DIA. ANCHOR(MAX. 16" O.C.)

BY OTHERS

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

PARAPET CAPBY OTHERS

WOODBLOCKING

BY OTHERS

SHIM AS REQ'DBY OTHERS

AH-101FRAMEEXTRUSION

532" ALUMINUMCSK RIVET@ MIN. 16" O.C.

AH-203HEADEXTRUSION

AH-107PERIMETERCLIP

4 MMVITRABONDFR CORE MCM

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

7Awww.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

PARAPET DETAIL

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

2"NOMINAL

1/4" DIA. ANCHOR(MAX. 16" O.C.)

BY OTHERS

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

12"

MIN.

AH-101FRAMEEXTRUSION

AH-202BASE

4 MM VITRABONDFR CORE MCM

SHIM AS REQ'DBY OTHERS

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

7Bwww.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

PARAPET DETAIL

WEATHER PROOFINGBY OTHERS

USE BACKERROD & SEALANTBETWEEN PANELSAT TOP OF PARAPET

AH-104T-CLIP

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

12"

MIN.

#12 X 3/8" SELFTAPPING SCREW(2) PER CLIP

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.

DESIGN BYARCHITECT

2"NOMINAL

2"NOMINAL

SHIM AS REQ'D

AH-101 FRAMEEXTRUSION

AH-204RUN FULL LENGTHBETWEEN HORIZONTALBASES

532" ALUMINUM

CSK RIVET@ MIN. 16" O.C.

AH-104T-CLIP

4 MM VITRABONDFR CORE MCM

14"

ADD STIFFENER ASSHOWN FOR THIS

CONDITION

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

8www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

INSIDE CORNER DETAIL

OUTLINE OFAH-202

BASE BELOW

OUTLINE OFSHIM BELOW

IF SELF TAPPING SCREWSPENETRATE WEATHERBARRIER, THESE LOCATIONSMUST BE SEALED

#12 X 3/4" SELF DRILLING TEKSCREWS MAY BE USED WITHEXTERIOR INSULATED WALLS

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

12"

MIN

#12 X 3/8" SELFTAPPING SCREW

(2) PER CLIP

OUTLINEOF SHIMBELOW

AH-101FRAMEEXTRUSION

532" ALUMINUM

CSK RIVET@ MIN. 16" O.C.

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

12"

MIN.

2"NOMINAL

SHIM AS REQ'D

AH-104T-CLIP

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

9www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

OUTSIDE CORNER DETAIL

4 MM VITRABONDFR CORE MCM

OUTLINE OFAH-202BASE BELOW

AH-204AT CORNERS

TO RUN FULL LENGTHBETWEEN

HORIZONTAL BASES

AH-104T-CLIP

AH-102TO RUN FULL LENGTH

BETWEENHORIZONTAL BASES

#12 X 1/2" SELFTAPPING SCREW

(1) PER CLIP

IF SELF TAPPING SCREWSPENETRATE WEATHERBARRIER, THESE LOCATIONSMUST BE SEALED

#12 X 3/4" SELF DRILLING TEKSCREWS MAY BE USED WITHEXTERIOR INSULATED WALLS

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

34"

MIN.

#12 X 3/8" SELFTAPPING SCREW(1) PER CLIP

OUTLINEOF SHIMBELOW

AH-101 FRAMEEXTRUSION

AH-207STARTER CLIP

532" ALUMINUMCSK RIVET@ MIN. 16" O.C.

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

2"NOMINAL

BACKER ROD& SEALANTBY OTHERS

SHIM AS REQ'D

AH-107PERIMETER CLIP

4 MM VITRABONDFR CORE MCM

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

10Awww.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

VERTICAL JAMB DETAIL - START

OUTLINE OFAH-202BASE BELOW

IF SELF TAPPING SCREWSPENETRATE WEATHERBARRIER, THESE LOCATIONSMUST BE SEALED

#12 X 3/4" SELF DRILLING TEKSCREWS MAY BE USED WITHEXTERIOR INSULATED WALLS

#12 X 1/2" SELFTAPPING SCREW(1) PER CLIP

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

34"

MIN.

#12 X 1/2" SELFTAPPING SCREW(1) PER CLIP

OUTLINEOF SHIMBELOW

AH-101 FRAMEEXTRUSION

AH-207STARTER CLIP

532" ALUMINUM

CSK RIVET@ MIN. 16" O.C.

SOLID BACKERBY OTHERS

2"NOMINAL

BACKER ROD& SEALANTBY OTHERS

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

10Bwww.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

VERTICAL JAMB DETAIL - END

AH-107PERIMETER CLIP

4 MM VITRABONDFR CORE MCM

WEATHERBARRIER

AS REQUIRED.DESIGN BYARCHITECT

OUTLINE OFAH-202

BASE BELOW

SHIM AS REQ'D

IF SELF TAPPING SCREWSPENETRATE WEATHERBARRIER, THESE LOCATIONSMUST BE SEALED

#12 X 3/4" SELF DRILLING TEKSCREWS MAY BE USED WITHEXTERIOR INSULATED WALLS

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

2"NOMINAL

1/4" DIA. ANCHOR(MAX. 16" O.C.) BY OTHERS

AH-101 FRAMEEXTRUSION

AH-202BASE

532" ALUMINUMCSK RIVET@ MIN. 16" O.C.

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

SHIM AS REQ'DBY OTHERS

5/16" WEEP HOLE & BAFFLEAT 8" FROM EACH END(℄ ON PANELS 60"-96")

12"

MIN.

AH-104 T-CLIP

4 MM VITRABONDFR CORE MCM

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

11www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

TYPICAL HORIZONTAL DETAIL

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

12"

MIN.

VARIES

1-3/4"

#12 X 3/8" SELFTAPPING SCREW(2) PER CLIP

OUTLINEOF SHIMBELOW

AH-101 FRAMEEXTRUSION

AH-204VERTICAL CLIP

532" ALUMINUM

CSK RIVET@ MIN. 16" O.C.

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

SHIM AS REQ'D

AH-104T-CLIP

4 MM VITRABONDFR CORE MCM

.157 ACM OR .125ALUMINUM PLATE. WIDTH

VARIES W/ PANEL SIZE

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

12www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

DIFF. DEPTH VERTICAL DETAIL

OUTLINE OFAH-202

BASE BELOW

IF SELF TAPPING SCREWSPENETRATE WEATHERBARRIER, THESE LOCATIONSMUST BE SEALED

#12 X 3/4" SELF DRILLING TEKSCREWS MAY BE USED WITHEXTERIOR INSULATED WALLS

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

VARIES

1/4" DIA. ANCHOR(MAX. 16" O.C.) BYOTHERS

AH-101FRAMEEXTRUSION

AH-202BASEEXTRUSION

532" ALUMINUMCSK RIVET@ MIN. 16" O.C.

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

SHIM AS REQ'DBY OTHERS

5/16" WEEP HOLE & BAFFLEAT 8" FROM EACH END(℄ ON PANELS 60"-96")

12"

MIN.

AH-104 T-CLIP

.157 ACM OR .125ALUMINUM PLATE. WIDTHVARIES W/ PANEL SIZE

SOLID BACKERBY OTHERS

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

13www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

DIFF. DEPTH HORIZONTAL DETAIL

4 MM VITRABONDFR CORE MCM

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

12"

MIN.

VARIES

1-3/4"

AH-101 FRAMEEXTRUSION

AH-202BASE5

32" ALUMINUMCSK RIVET

@ MIN. 16" O.C.

AH-104T-CLIP

4 MM VITRABONDFR CORE MCM

.157 ACM OR .125ALUMINUM PLATE. WIDTH

VARIES W/ PANEL SIZE

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

14www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

DIFF. DEPTH VERTICAL DETAIL

#12 X 3/8" SELFTAPPING SCREW(2) PER CLIP

OUTLINEOF SHIMBELOW

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

SHIM AS REQ'D

OUTLINE OFAH-202

BASE BELOW

IF SELF TAPPING SCREWSPENETRATE WEATHERBARRIER, THESE LOCATIONSMUST BE SEALED

#12 X 3/4" SELF DRILLING TEKSCREWS MAY BE USED WITHEXTERIOR INSULATED WALLS

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

VARIES

1/4" DIA. ANCHOR(MAX. 16" O.C.) BYOTHERS

SHIM AS REQUIREDBY OTHERS

AH-101 FRAMEEXTRUSION

AH-202BASE

532" ALUMINUMCSK RIVET@ MIN. 16" O.C.

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

SHIM AS REQ'DBY OTHERS

5/16" WEEP HOLE & BAFFLEAT 8" FROM EACH END(℄ ON PANELS 60"-96")

12"

MIN.

AH-104 T-CLIP

4 MM VITRABONDFR CORE MCM

.157 ACM OR .125ALUMINUM PLATE.WIDTH VARIES W/PANEL SIZE

SOLID BACKERBY OTHERS

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

15www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

DIFF. DEPTH HORIZONTAL DETAIL

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

34"

MIN.

#12 X 1/2" SELFTAPPING SCREW

(1) PER CLIP

OUTLINEOF SHIMBELOW

AH-101 FRAMEEXTRUSION

AH-207STARTER CLIP

532" ALUMINUMCSK RIVET@ MIN. 16" O.C.

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.

DESIGN BYARCHITECT

2"NOMINAL

BACKER ROD& SEALANTBY OTHERS

SHIM AS REQ'D

AH-107PERIMETER

CLIP

4 MM VITRABONDFR CORE MCMWINDOW SYSTEM

BY OTHERS

COUNTERFLASHING

BY OTHERS

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

16www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

DISSIMILAR METALS - JAMB

OUTLINE OFAH-202BASE BELOW

IF SELF TAPPING SCREWSPENETRATE WEATHERBARRIER, THESE LOCATIONSMUST BE SEALED

#12 X 3/4" SELF DRILLING TEKSCREWS MAY BE USED WITHEXTERIOR INSULATED WALLS

#12 X 3/8" SELFTAPPING SCREW

(1) PER CLIP

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

1/2" MIN.

2"NOMINAL

1/4" DIA. ANCHOR(MAX. 16" O.C.)

BY OTHERS

AH-101 FRAMEEXTRUSION

SHOP ATTACHED

AH-205SILL

532" ALUMINUM

CSK RIVET@ MIN. 16" O.C.

COUNTERFLASHING

BY OTHERS

SOLID BACKERBY OTHERS

SHIM AS REQ'DBY OTHERS

5/16" WEEP HOLE & BAFFLEAT 8" FROM EACH END(℄ ON PANELS 60"-96")

4 MM VITRABONDFR CORE MCM

18"

WINDOW SYSTEMBY OTHERS

WEATHER BARRIERAS REQUIRED.DESIGN BYARCHITECT

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

17www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

DISSIMILAR METALS - SILL

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

2 1/2"MIN

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

18www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

TYPICAL SOFFIT DETAIL

SEE DETAIL 5A

FASCIA PANEL

SOFFIT PANEL

SEE DETAIL 5A

5/16" WEEP HOLE& BAFFLE AT 8"

FROM EACH END(℄ ON PANELS

60"-96")

ALL BASE EXTRUSIONSTO RUN FULL LENGTH

IF SELF TAPPING SCREWSPENETRATE WEATHERBARRIER, THESE LOCATIONSMUST BE SEALED

#12 X 3/4" SELF DRILLING TEKSCREWS MAY BE USED WITHEXTERIOR INSULATED WALLS

© Copyright Fairview Architectural LLC - Patented and/or Patent Pending

#12 X 3/8" SELFTAPPING SCREW(1) PER CLIP

SOLID BACKERBY OTHERS

WEATHER BARRIERAS REQUIRED.

DESIGN BYARCHITECT

2"NOMINAL

2"NOMINAL

AH-101 FRAMEEXTRUSION

AH-204RUN FULL LENGTHBETWEEN HORIZONTALBASES

532" ALUMINUM

CSK RIVET@ MIN. 16" O.C.

AH-104T-CLIP

14"

ADD STIFFENER ASSHOWN FOR THIS

CONDITION

DWG-01Sheet

Project Number

Drawn By

No

No

RevisionsDate

Date

Date Drawn

NCDSProject

19www.fairview-na.com

ARROWHEAD RAINSCREEN PANEL SYSTEM10/12/2017

SOFFIT TO WALL DETAIL

OUTLINE OFAH-202

BASE BELOW

SHIM AS REQ'D

OUTLINE OFSHIM BELOW

12"

MIN.

4 MM VITRABONDFR CORE MCM

IF SELF TAPPING SCREWSPENETRATE WEATHERBARRIER, THESE LOCATIONSMUST BE SEALED

#12 X 3/4" SELF DRILLING TEKSCREWS MAY BE USED WITHEXTERIOR INSULATED WALLS