Asbestos Free Arc Quencher Replacement Kits Replaces asbestos plate style arc quenchers on AK and early AKRpower circuit breakers with reliable , proven steel plate style arc quenchers used on modern AKR breakers . Easy- to - use kits provide all required parts , hardware and instructions for arc quencher replacement on one breaker . Kits meet ANSI C 37.59 requirements for safe , reliable performance . GE Electrical Distribution & Control

Upload: others

Post on 12-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AsbestosFree ArcQuencher ReplacementKits · Title: DET-096 Author:  Subject - LV-EQUIP - BREAKERS - GE - AK - Keywords: ASBESTOS FREE ARC QUENCHER REPLACEMENT KITS FOR …

AsbestosFreeArc QuencherReplacementKits

Replaces asbestos plate style arcquenchers on AK and early AKRpowercircuit breakers with reliable,provensteel plate style arc quenchers used onmodern AKR breakers.Easy-to-use kits provide all requiredparts,hardware and instructions for arcquencher replacementon one breaker.Kits meetANSI C37.59 requirements forsafe, reliable performance.

GE Electrical Distribution & Control

Courtesy of NationalSwitchgear.com
Page 2: AsbestosFree ArcQuencher ReplacementKits · Title: DET-096 Author:  Subject - LV-EQUIP - BREAKERS - GE - AK - Keywords: ASBESTOS FREE ARC QUENCHER REPLACEMENT KITS FOR …

Everything you need in one packageThe Asbestos Free Arc Quencher Replacement kits listed below are shipped complete with detailed installationinstructions and everything you need for fast, easy arc quencher replacement.• Asbestos free metal plate or ceramic arc quenchers• Contact guides and arc runners (when required )

• Asbestos free replacement barriers (when required)• All required mounting hardware

Arc Quencher Replacement Kit catalog number selection

AK025 AQR1 G1Breaker Model Application

AK-15AK-25AKU-25

AQR1= Arc Quencher ReplacementKit Generation 1

For Asbestos Removal = G1Removal kit for ceramic arc quenchers = G2= AK025 124

AKR-30S = AKR3S ’•*AKR-30AKRU-30 = AKR30

AKR-30HAKRU-30H = AKR3H

AK-50AKT-50AKU-50

= AKO50 24

AKJ-50AKJT-50AKJU-50AKR-50AKRT-50AKRU-50

= AKR50

AKJ-50HAKJT-50HAKJU-50HAKR-50HAKRT-50HAKRU-50H

= AKR5H

AKJ-50AKJT-50 = AKD50 *AKJU-50AKJ-50HAKJT-50H = AKD5H 3

AKJU-50HAK-75AKR-75AK-100AKR-100

= AK075 24

= AKR75 2

= AKO10 24

= AKR10 2

1 Kits contain replacement barriers only;arc quenchers do not contain asbestos.

? G2 kits are not available for these breakers;please contact the factory for individualreplacement arc quenchers.

3 These kits are for use on breakers used inAKD and AKD-5 switchgear and substructures.

4 Does not apply to AK-1 series breakers.

Contact your local GE sales office or call GE ED&C SwitchgearOperation at 319-753-8400 for details and ordering information.

GE Electrical Distribution & ControlGeneral Electric Company41 Woodford Avenue, Plainville, CT 06062(£) 1995 General Electric CompanyDET-096 0495