Important
InstallerAssembly Instructions
Electrical Wiring Diagrams
Important Assembly InstructionsEffective January 2005
Bulletin #542(Replaces April 2003)
ELECTRICAL WIRING DIAGRAMS
CONTROLS PAGEReversing Drum Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Safety Disconnect Switch or Manual Start Switch . . . . . . . . . . . . . . . . . . . . . . . . . .4
Push Button Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Reversing Three Phase Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Non-Reversing Three Phase Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Reversing Single Phase Magnetic Starter (115 Volt) . . . . . . . . . . . . . . . . . . . . . . . .8
Reversing Single Phase Magnetic Starter (230 Volt) . . . . . . . . . . . . . . . . . . . . . . . .9
Non-Reversing Single Phase Magnetic Starter (115 Volt) . . . . . . . . . . . . . . . . . . .10
Non-Reversing Single Phase Magnetic Starter (230 Volt) . . . . . . . . . . . . . . . . . . .11
MOTOR
Motor Wiring Diagram Single Phase 115/230 Volt . . . . . . . . . . . . . . . . . . . . . . . . .12
Motor Wiring Diagram Three Phase Single Voltage Motors . . . . . . . . . . . . . . . . .13
Motor Wiring Diagram Three Phase Dual Voltage Motors . . . . . . . . . . . . . . . . . . .13
Reliance Electric’s MD60 A-C Variable Speed Drive . . . . . . . . . . . . . . . . . . . . . . . . .14
● Engineering Data• Wiring Diagram — Reversing Drum Switch
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
3January—2005
To Motor(See wiring diagram
Pg. 12)
The reversing drum switch is similar tothe manual start switch, but has theadded advantage of being able toreverse the motor. It is standardequipment on most HYTROL portablemodel conveyors, and is normallymounted near the conveyor drive. Thereversing drum switch is considered asa single point control, but may beextended through the use of a remotecontrol rod (optional item), allowing theoperator to control the conveyor fromeither end. NOTE: This switch does notprovide for motor overload protection.
To Change motor rotation, interchange T5 and T8 leads
Input Power115 Volt,
Single Phase
FWD REVOFF
(L2)
(T8)
(T5)(T2 & T4)
(T1 & T3)(GROUND)
(L1)(GROUND)
1 2
3 4
5 6
•Single Phase — ReversingDrum Switch — 115 Volts AC
To MotorWire nut together
T2,T3, and T8(See wiring diagram
Pg. 12)
To Change motor rotation, interchange T5 and T8 leads
(L2)
(T1)
(T4)(T5)(GROUND)
(L1)(GROUND)
1 2
3 4
5 6
•Single Phase — ReversingDrum Switch — 230 Volts AC
1. Customer is to ground switch and motorat points shown on diagram.
2. Consult national electrical code for wiresize to be used for connections betweenmotor and switch.
3. This method provides no overloadprotection for motor.
4. Hytrol Part No. 032.1035. Allen-Bradley Reversing Drum Switch
Input Power
(See wiringdiagramPg. 13)
NOTE: To Change motor rotation, interchange any two line leads.
(L3)
(L2)(T2)(T3)(T1)
(GROUND)
(L1)
(GROUND)
1 2
3 4
5 6
•Three Phase — Reversing Drum Switch — 208-230/460 Volts AC
Input Power To Motor
● Engineering Data• Wiring Diagram — Safety Disconnect Switch or
Manual Start Switch
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
4January—2005
•Three Phase—208 - 230/460 Volts AC
1. In NEMA 1 Enclosure2. Hytrol Part Number 032.10143. This Switch has no motor
protection4. Max. 30 Amps, 600 Volts5. UL Listed 724F, CSA
(GROUND)
(L1)
(L2)
(L3)
•Single Phase—115/230 Volts AC
The manual start switch is a simple “ON-OFF” switch that directlycontrols the motor power. It is suitable for a large number ofconveyor applications not requiring a reversible operation. Themanual start switch is a single point control and is normally mountedat or near the drive. NOTE: This switch does not provide: motoroverload protection.
1. In NEMA 1 Enclosure2. Hytrol Part Number 032.10143. This Switch has no motor
protection4. Max. 30 Amps, 600 Volts5. UL Listed 724F, CSA
(GROUND)
(T1)
(T2)
(T3)TO MOTORSEE PAGE 13
POWERLINE
LINE
LINE
LOAD
LOAD
LOAD
(GROUND)
(L1)
(L2)
(GROUND)
(T1)
(T2)
TO MOTORSEE PAGE 12
POWER
LINE
LINE
LOAD
LOAD
LINE LOAD
● Engineering Data
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
5January—2005
• Wiring Diagram — Push Button Station
•Single “Start-Stop” Station
• Two “Start-Stop” Stations
•Three or More “Start-Stop” Stations
•Single “Fwd-Rev-Stop” Station
• Two “Fwd-Rev-Stop” Stations
•Three or More “Fwd-Rev-Stop” Stations
START
AB
C
STOP
START
A
B
CSTOP STOP
START
START
A
B
CGROUND
START START
Center Station is TYP. Wiring for Three or More Push-Button Stations Center Station is TYP. Wiring for Three or More Push-Button Stations
REV
STOP
FWD
FWDFWD
REV
STOP STOP
REV
FWD
REV
STOP
FWD
REV
STOP
FWD
REV
STOP
A
B
C
D
A
B
C
D
A
B
C
D
STOP STOP STOP
Remote push-button stations, designed for magneticstarters, are used to control the starter coils.Starters may be controlled by single or multiplepush-button stations. Hytrol’s standard controlvoltage through the push-button station is 115 volt,single phase.
GROUND
GROUND
GROUND
GROUND
GROUND
● Engineering Data
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
6January—2005
• Wiring Diagram — Reversing Three Phase StarterThe reversing magnetic starter directly controls thecurrent to the motor by actually closing the required set ofcontacts to cause motor rotation in the desired direction(Forward/Reverse), and provides a remote means ofconveyor directional control. Remote pushbuttonstations, designed for magnetic starters, are used tocontrol the starter coils. Starters may be controlled bysingle or multiple pushbutton stations. Magnetic startersalso provide the added feature of overload protection forthe motor.
Three Phase Power,voltage as required for the motor
● Engineering Data
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
7January—2005
• Wiring Diagram— Non-Reversing Three Phase Starter
The non-reversing magnetic starter directly controls the current tothe motor by actually (closing) the required set of contacts to causemotor rotation in one direction, and provides a remote means ofconveyor control. Remote pushbutton stations, designed formagnetic starters, are used to control the starter coil. Starters maybe controlled by single or multiple pushbutton stations. Magneticstarters also provide the added feature of overload protection forthe motor.
Three Phase Power, voltage as required for the motor
● Engineering Data
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
8January—2005
• Wiring Diagram — Reversing Single Phase Magnetic Starter
The reversing magnetic starter directly controls the current to themotor by actually closing the required set of contacts to causemotor rotation in the desired direction (Forward/Reverse), andprovides a remote means of conveyor directional control.Remote push-button stations, designed for magnetic starters, areused to control the starter coils. Starters may be controlled bysingle or multiple push-button stations. Magnetic starters alsoprovide the added feature of overload protection for the motor.
115 Volt, Single Phase Power
● Engineering Data
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
9January—2005
230 Volt, Single Phase Power
• Wiring Diagram — Reversing Single Phase Magnetic Starter
The reversing magnetic starter directly controls the current to themotor by actually closing the required set of contacts to causemotor rotation in the desired direction (Forward/Reverse), andprovides a remote means of conveyor directional control.Remote push-button stations, designed for magnetic starters, areused to control the starter coils. Starters may be controlled bysingle or multiple push-button stations. Magnetic starters alsoprovide the added feature of overload protection for the motor.
● Engineering Data
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
10January—2005
• Wiring Diagram — Non-Reversing Single Phase Magnetic Starter
The non-reversing magnetic starter directly controls the current tothe motor by actually closing the required set of contacts to causemotor rotation in one direction, and provides a remote means ofconveyor control. Remote pushbutton stations, designed formagnetic starters, are used to control the starter coil. Starters maybe controlled by single or multiple push-button stations. Magneticstarters also provide the added feature of overload protection for themotor.
115 Volt, Single Phase Power
● Engineering Data
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
11January—2005
• Wiring Diagram — Non-Reversing Single Phase Magnetic Starter
The non-reversing magnetic starter directly controls the current tothe motor by actually closing the required set of contacts to causemotor rotation in one direction, and provides a remote means ofconveyor control. Remote pushbutton stations, designed formagnetic starters, are used to control the starter coil. Starters maybe controlled by single or multiple push-button stations. Magneticstarters also provide the added feature of overload protection for themotor.
230 Volt, Single Phase Power
Counterclockwiserotation
Clockwiserotation
Counterclockwiserotation
Clockwiserotation
L1 L2 JOIN
T1 T4,T5 T2,T3 and T8
T1 T4,T8 T2,T3 and T5
T1,T3,T8 T2,T4,T5
T1,T3,T5 T2,T4,T8
230VOLT
115VOLT
● Engineering Data
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
12January—2005
• Motor Wiring Diagram
NOTES:1. To reverse motor rotation interchange
T5 and T8 leads2. Wiring reference
SINGLE PHASE, 115/230 VOLTFigure B
THREE PHASE, SINGLE VOLTAGE MOTORS
Figure A
● Engineering Data
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
13January—2005
NOTES:1. Y-CONNECTED2. To reverse motor rotation
interchange any two power leads
• Motor Wiring Diagram
NOTES:1. Y-CONNECTED, DUAL VOLTAGE
MOTOR2. To reverse motor rotation interchange
any two power leads3. Wiring reference4. Motors with leads T10, T11, T12; these
three leads are to be connected together.
L1 L2 L3 TIE TOGETHER
230 VOLT OR T1,T7 T2,T8 T3,T9 T4,T5200-208 VOLT and T6
460 VOLT OR T1 T2 T3 (T4,T7) 400-416 VOLT (T5,T8)
(T6,T9)
THREE PHASE, DUAL VOLTAGE MOTORS200-208/400-416 VOLTOR 230/460 VOLT
Figure C
● Engineering Data
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
14January—2005
• Reliance Electric’s MD65 A-C Variable Speed Drive
● Engineering Data
TECHNICAL MANUALHYTROL CONVEYOR COMPANY, INC.
JONESBORO, ARKANSAS
Page:
15January—2005
• Reliance Electric’s MD65 A-C Variable Speed Drive