assignment3:

4
Assignment3: The main purpose of this assignment was evaluating the impact of solid volume defined in front of examined building to consider the Impact of its shadow on main building. The distance building and volume have neglect able impact on inside temperature of target building. numbers of variable including window to wall ratio, rotation of building toward west and east and level of curviness of the front façade of the building were defined and their impact on inside thermal condition were evaluated. The first graph depicts the inside Monthly temperature when windows to wall ratio is equal to 0.9 percent. Next two graphs demonstrate the temperature fluctuation in term Of a year when window to wall (WTW) ratio is equal to 0.5 and 0.1 respectably. As the graphs show inside temperature decreases considerably as the WTW ratio decreases. The effect of orientation toward west and east is demonstrated in third page. As the result show there is no magnificent different in thermal Conditions when the building is at its maximum diversion toward East or West, just couple of degrees on its peak. Finally the impact of curviness and shape of front façade has been examined and small change on the peak of graph observed. In fact the more Lanier façade caused only 2 degree decrease of temperature.

Upload: saki

Post on 22-Feb-2016

37 views

Category:

Documents


0 download

DESCRIPTION

Assignment3: The main purpose of this assignment was evaluating the impact of solid volume defined in front of examined building to consider the Impact of its shadow on main building. The distance building and volume have neglect able impact on inside temperature of target building. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Assignment3:

Assignment3:The main purpose of this assignment was evaluating the impact of solid volume defined in front of examined building to consider the Impact of its shadow on main building. The distance building and volume have neglect able impact on inside temperature of target building.numbers of variable including window to wall ratio, rotation of building toward west and east and level of curviness of the front façade of the building were defined and their impact on inside thermal condition were evaluated. The first graph depicts the inside Monthly temperature when windows to wall ratio is equal to 0.9 percent. Next two graphs demonstrate the temperature fluctuation in term Of a year when window to wall (WTW) ratio is equal to 0.5 and 0.1 respectably. As the graphs show inside temperature decreases considerably as theWTW ratio decreases.The effect of orientation toward west and east is demonstrated in third page. As the result show there is no magnificent different in thermal Conditions when the building is at its maximum diversion toward East or West, just couple of degrees on its peak.Finally the impact of curviness and shape of front façade has been examined and small change on the peak of graph observed. In fact the moreLanier façade caused only 2 degree decrease of temperature.

Page 2: Assignment3:

Window to wall ratio

Page 3: Assignment3:

orientation

Page 4: Assignment3:

Impact of curviness of front façad on inside thermal conditions