astral wire guard pipes
TRANSCRIPT
-
8/18/2019 Astral Wire Guard Pipes
1/12
STRONG NAHIN, ASTRAL STRONG!! TM
NO
CORROSION
UV RESISTANTCORROSION
RESISTANT
ASTRAL WIRE GUARD™ - CONDUIT PIPES & FITTINGS
Technical Manual
For Residential & Commercial Applications
-
8/18/2019 Astral Wire Guard Pipes
2/12
COMPANY PROFILE
01 www.astralcpvc.com
ASTRAL POLYTECHNIK LIMITED, introduced CPVC plumbing system for the
first time in India in 1999 and changed the history of Indian Plumbing
®Industry. Today ASTRAL is undoubtably leader in CPVC plumbing system.
®ASTRAL is known for innovative products and within 15 years of its
®existence, ASTRAL has introduced so many products that are ahead of the
time, like CPVC fire sprinkler system, CPVC-AL-CPVC multi layer pipes,
Foamcore multilayer pipes, Underground drainage system, Lead free
Column Pipes for submersible pumps, piping system for soil, waste and rain
water and click ring type uPVC drain waste and vent system.
®ASTRAL now introduces "Wire Guard" rigid PVC conduit pipes and fittings.
®As known for its quality, reliability and trust worthiness, ASTRAL offers
superior quality "Wire Guard" rigid conduit pipes and fittings, with all kind
of necessary accessories to complete the need of time. Manufactured with
TMstate of the art machines and world class set up, ASTRAL WIRE GUARD
assures 100% satisfaction for life time.
Santej Plant
Himachal Pradesh Plant
Dholka Plant
Hosur Plant
Head Office - Ahmedabad, Gujarat
-
8/18/2019 Astral Wire Guard Pipes
3/12
02www.astralcpvc.com
INTRODUCTION
TMASTRAL WIRE GUARD conduit pipes and fittings have
good impact strength, superior light proofness and
chemical resistance. It has high heat deflection
temperature and ductile behavior even at low
temperatures.TM
ASTRAL WIRE GUARD conduit is the lightest in weight
compared to other materials and usually lower in cost thenTMother terms of conduit. ASTRAL WIRE GUARD conduit is
available in three different wall thicknesses with the thin-
wall variety only suitable for embedded use in concrete
and heavier grades suitable for direct burial and exposed
work.TM
ASTRAL WIRE GUARD conduit pipes and fittings resists
moisture and many corrosive substances. Joints to fittings
are made with slip-on solvent welded connections, which
set up rapidly after assembly and attain full strength in
about few hours.
INTRODUCTION : COLOUR
ASTRAL WIRE GUARD electrical conduits are available in
Black Colour. Other colours are available on request.
TM
TM®ASTRAL Rigid PVC WIRE GUARD conduit
pipes are manufactured in accordance with
Bureau of Indian Standards specifications
IS 9537 : 3 in the range of 20mm to 63mm
with light, medium and heavy range.
TMASTRAL WIRE GUARD PRODUCT SPECIFICATION
BLUE : Light Mechanical Strength (LMS)
YELLOW : Medium Mechanical Strength (MMS)
WHITE : Heavy Mechanical Strength (HMS)
COLOUR CODES FOR CLASS OF PIPES
DIMENSIONAL DETAILS OF PVC CONDUITS AS PER IS 9537 : 3
Out SideDiameter
in mm
Toleranceon OD
Light Medium
Min.ID
Min. WallThickness
Max. WallThickness
Min.ID
Min. WallThickness
Max. WallThickness
20
25
32
40
50
63
-0.3
-0.4
-0.4
-0.4
-0.5
-0.6
17.4
22.1
28.6
35.8
45.1
57.0
1.15
1.25
1.50
1.90
2.20
2.70
1.30
1.45
1.70
2.10
2.45
3.00
16.90
21.40
27.80
35.40
44.30
–
1.40
1.60
1.90
2.10
2.60
–
1.55
1.80
2.10
2.30
2.85
–
15.80
20.60
26.60
34.40
43.20
–
1.95
2.00
2.50
2.60
3.15
–
2.10
2.20
2.70
2.80
3.40
–
Heavy
Min.ID
Min. WallThickness
Max. WallThickness
Fire is one of the major hazards to life and property, and
electrical installations are perhaps one primary source of
generation and propagation of fire. Protection of cables
and raceways against fire is therefor an important and
primary consideration in the design and industry
standards.
-
8/18/2019 Astral Wire Guard Pipes
4/12
ADVANTAGES
03 www.astralcpvc.com
ADVANTAGES
STRENGTH
NO MAINTENANCE
DURABILITY
VERSATILE AND ELEGANT
ENVIRONMENTAL IMPACT
TMASTRAL WIRE GUARD have high
mechanical strength that is attested by
tests conduced as specified in IS 9537: 3.
Hence they can be used both in open /
surface and concealed installation.
TMASTRAL WIRE GUARD requires no
maintenance due to its excellent
weather protected properties.
TMA ST RA L W IR E G UA RD e le ctr ica l
conduit pipes last for a lifetime.
The physical properties of PVC allow
designers a high degree of freedom
while designing. Superior finished
pipes and fittings add a touch of
beauty to the buildings .
PVC has a lower feedstock energy
especially compared to other polymers
and common building materials. It is
the least energy intensive of all
thermoplastics. In life cycle analysisand independent studies, PVC's
environmental impact has been found
most favorable, so the more usage of
PVC will greatly help to keep our global
natural resources intake for longer
period of time. It is not polluting air,
water or land during manufacturing or
service life and can be recycled after
prolonged service life.
HIGH CORROSION RESISTANCE
FIRE RESISTANCE
CONDUCTIVITY
LIGHTWEIGHT
EASY WIRING
EASY INSTALLATION
TMASTRAL WIRE GUARD is non-corrosive
by nature and are not attacked by
corrosive, salty atmosphere & excessive
humidity. They are immune to chemical
and galvanic corrosion. Hence they are
ideal electrical conduits.
TMASTRAL WIRE GUARD do not support
combustion and when the source of
ignition is removed they are self
extinguishing.
TMASTRAL WIRE GUARD is non-conductor
TMof electricity. ASTRAL WIRE GUARD
conduit prevents electrical shocks.
Hence they are most suitable for
electrical conduits.
TMASTRAL WIRE GUARD have low specific
gravity, which implies that it is much
lighter than the pipes made from more
®traditional materials. ASTRAL Pipes are
therefore easier to handle. This result in
reduced transportation & installationcosts.
TMASTRAL WIRE GUARD have smooth
interior walls which helps in reducing the
friction thus helping in easy wiring.
TMASTRAL WIRE GUARD can be shaped
and joined without difficulty.TM
ASTRAL WIRE GUARD Pipes are joined
by solvent cement, which is simpler,
cheaper & easier.
-
8/18/2019 Astral Wire Guard Pipes
5/12
TECHNICAL SPECIFICATIONS
04www.astralcpvc.com
BASIC PHYSICAL PROPERTIES
PROPERTY TEST METHOD CONDITION ENGLISH UNITS SI UNITS
Specific Gravity
Water Absorption
Rockwell Hardness
Izod Impact
Tensile Strength
Tensile Modulus
Flexural Strength
Flexural Modulus
Compressive Strength
Compressive Modulus
Coefficient of Thermal
Expansion
Thermal Conductivity
Heat Distortion
Temperature @ 66 psi
Flammability Rating
Flame Spread
Smoke Developed
Limiting Oxygen Index
Dielectric Strength
Dielectric Constant
Power Factor
Volume Resistivity
Insulation Resistance
MECHANICAL
THERMAL
FIRE RESISTANCE PROPERTY
ELECTRICAL
ASTM D792
ASTM D570
ASTM D785
ASTM D256
ASTM D638
ASTM D638
ASTM D790
ASTM D790
ASTM D695
ASTM D695
ASTM D696
ASTM C177
ASTM D638
UL 94
ASTM E84
ASTM E84
ASTM D2863
ASTM D147
ASTM D150
ASTM D150
ASTM D257
73°F / 23°C
73°F / 23°C
212°F / 100°C
73°F / 23°C
73°F / 23°C
73°F / 23°C
73°F / 23°C
73°F / 23°C
73°F / 23°C
73°F / 23°C
73°F / 23°C
0.062 in/0.157 cm
60hz, 30°F/-1°C
60Hz 73°F/23°C
73°F / 23°C
1.40 to 1.46
+0.03%
+0.55%
119
1.5 ft lbs/in
7000 psi
3,60,000 psi
15,100 psi
4,15,000 psi
9000 psi
1,96,000 psi
-53.4 x 10 in/in/°F
20.95 BTU in/hr/ft /°F
179°F
V-0, 5VB, 5VA
15
70-125
45%
1100
3.70
0.0096
≥100Ω
1.40 to 1.46
+0.03%
+0.55%
------
60 J/m2
55 N/mm2
2500 N/mm2
104 N/mm2
2860 N/mm2
62 N/mm2
1350 N/mm
-56.3 x 10 m/m/°K
20.14 Wm/°K/m
80°C
4,30,000 V/cm
3.70
0.009615
5.4 x 10 ohm/cm
BATCH WISE TESTING BEFORE DISPATCHING
1. Checking of dimensions 2. Bending Test
3. Compression Test 4. Impact Test
5. Collapse Test 6. Resistance to Heat
7. Resistance to Burning 8. Electrical Characteristics
®ASTRAL is having well equipped quality testing laboratory in their plant as per the ISI
standards for testing of all PVC electrical conduits & accessories. The high quality
performance is attained with experienced and qualified staff and skilled workers.TM
Each batch of ASTRAL WIRE GUARD pipes & fittings are tested as per Bureau of
®Indian Standards relevant scheme of testing and inspection. ASTRAL takes the
following acceptance and type tests in the laboratory before dispatch the
material.
QUALITY CONTROL
GENERAL
-
8/18/2019 Astral Wire Guard Pipes
6/12
05 www.astralcpvc.com
PVC ROUND CONDUIT PIPE & FITTINGS
PRODUCTCODE
SIZE OD(mm)
STANDARDPACKPRODUCT
PRODUCTCODE
SIZE OD(mm)
STANDARDPACKPRODUCT
2025
32
40
50
63
100 x 3 mtr100 x 3 mtr
50 x 3 mtr
25 x 3 mtr
25 x 3 mtr
18 x 3 mtr
LMS (LOW MECHANICAL STREES)
MMS (MEDIUM MECHANICAL STREES)
20
25
3240
50
100 x 3 mtr
100 x 3 mtr
50 x 3 mtr25 x 3 mtr
25 x 3 mtr
HMS (HIGH MECHANICAL STREES)
20
25
32
40
50
100 x 3 mtr
100 x 3 mtr
50 x 3 mtr
25 x 3 mtr
25 x 3 mtr
FOR PLAIN END CONDUITS
20
25
20
15
CIRCULAR BOX - TERMINAL (1WAY)
AC 600-020L - 3MAC 600-025L - 3M
AC 600-032L - 3M
AC 600-040L - 3M
AC 600-050L - 3M
AC 600-063L - 3M
AC 600-020M - 3M
AC 600-025M - 3M
AC 600-032M - 3MAC 600-040M - 3M
AC 600-050M - 3M
AC 600-020H - 3M
AC 600-025H - 3M
AC 600-032H - 3M
AC 600-040H - 3M
AC 600-050H - 3M
AC 210 - 201
AC 210 - 251
AC 210 - 202 A
AC 210 - 252 A
20
25
20
15
CIRCULAR BOX - ANGLE (2WAY)
LMS (LOW MECHANICAL STREES)
FOR SOCKET END CONDUITS
AC 600-020L -SS - 3MAC 600-025L -SS - 3M
AC 600-032L -SS - 3M
AC 600-040L -SS - 3M
AC 600-050L -SS - 3M
AC 600-063L -SS - 3M
2025
32
40
50
63
100 x 3 mtr100 x 3 mtr
50 x 3 mtr
25 x 3 mtr
25 x 3 mtr
18 x 3 mtr
AC 600-020M - SS - 3M
AC 600-025M - SS - 3M
AC 600-032M - SS - 3M
AC 600-040M - SS - 3M
AC 600-050M - SS - 3M
AC 600-020H - SS - 3M
AC 600-025H - SS - 3M
AC 600-032H - SS - 3M
AC 600-040H - SS - 3M
AC 600-050H - SS - 3M
20
25
3240
50
20
25
32
40
50
100 x 3 mtr
100 x 3 mtr
50 x 3 mtr25 x 3 mtr
25 x 3 mtr
100 x 3 mtr
100 x 3 mtr
50 x 3 mtr
25 x 3 mtr
25 x 3 mtr
MMS (MEDIUM MECHANICAL STREES)
HMS (HIGH MECHANICAL STREES)
AC 210 - 202 T
AC 210 - 252 T
20
25
20
15
CIRCULAR BOX - THROUGH (2WAY)
AC 210 - 203
AC 210 - 253
20
25
20
15
CIRCULAR BOX - TEE (3WAY)
-
8/18/2019 Astral Wire Guard Pipes
7/12
06www.astralcpvc.com
PVC ROUND CONDUIT PIPE & FITTINGS
AC 220 - 203
AC 220 - 253
*
*
20
25
10
10
AC 220 - 204
AC 220 - 254
*
*
20
25
10
10
DEEP CIRCULAR BOX - TEE (3WAY)
BOX - INTERSECTION (4WAY)
BRANCH - 2WAY (U)
AC 230 - 020U
AC 230 - 025U
20
25
20
20
PRODUCTCODE
SIZE OD(mm)
STANDARDPACKPRODUCT
PRODUCTCODE
SIZE OD(mm)
STANDARDPACKPRODUCT
CIRCULAR EXTENSION RING
AC 211 - 020
AC 211 - 025
20
25
50
40
BRANCH - 3WAY (Y)
AC 230 - 020YAC 230 - 025Y
2025
2020
BRANCH - 4 WAY (H)
AC 230 - 020H
AC 230 - 025H
20
25
15
20
AC 212 - 020 20 30
AC 200 - 065 65 150
LOOP IN BOX
CIRCULAR LID
AC 237 - 252 25 > 20 250
REDUCER
AC 210 - 204
AC 210 - 254*
* 20
25
20
15
CIRCULAR BOX - INTERSECTION (4WAY)
AC 220 - 201
AC 220 - 251*
* 20
25
10
10
DEEP CIRCULAR BOX - TERMINAL (1WAY)
AC 220 - 202 A
AC 220 - 252 A
*
*
20
25
10
10
AC 220 - 202 T
AC 220 - 252 T
*
*
20
25
10
10
DEEP CIRCULAR BOX - ANGLE (2WAY)
DEEP CIRCULAR BOX - THROUGH (2WAY)
* Introducing very shortly
AC 229 - 020
AC 229 - 025
AC 229 - 032
AC 229 - 040
AC 229 - 050
20
25
32
40
50
200
125
60
30
20
AC 209 - 020*
AC 209 - 025*
AC 209 - 032*
AC 209 - 040
AC 209 - 050
AC 209 - 063
20
25
32
40
50
63
50
25
15
5
4
4
COUPLER
SLIP TYPE BEND
SLIP TYPE BEND (ISI)
AC 209 - 020 I
AC 209 - 025 I
AC 209 - 032 I
AC 209 - 040 I
AC 209 - 050 I
20
25
32
40
50
30
15
5
1
1
AC 235 - 020
AC 235 - 025
AC 235 - 032
AC 235 - 040
AC 235 - 050
20
25
32
40
50
200
100
75
50
25
FEMALE BUSH ADAPTER
AC 242 - 020* 20 200
ROUND 'U' CLIP
-
8/18/2019 Astral Wire Guard Pipes
8/12
07 www.astralcpvc.com
PVC ROUND CONDUIT FITTINGS
PRODUCTCODE
SIZE OD(mm)
STANDARDPACKPRODUCT
PRODUCTCODE
SIZE OD(mm)
STANDARDPACKPRODUCT
AC 241 - 020
AC 241 - 025
20
25
200
150
SADDLE STRAP
AC 240 - 020
AC 240 - 025AC 240 - 032
AC 240 - 040
AC 240 - 050*
AC 240 - 063*
20
2532
40
50
63
200
150100
100
100
50
SPACE BAR SADDLE
* Introducing very shortly
LID SURFACE SWITCH BOX
AC 263 - 033*
AC 263 - 063*
3'x3'75x756'x3'
160x75
60
75
AC 261 - 332*
AC 261 - 443*
AC 261 - 643*
AC 261 - 663*
AC 261 - 993*
AC 261 - 124*
75x75x503'x3'x2'
110x110x754'x4'x3'
160x110x756'x4'x3'
160x160x756'x6'x3'
225x225x759'x9'x3'
300x300x11012'x12'x4'
10
1
1
1
1
1
ADAPTABLE BOX WITH LID
SWITCH BOX-FLUSH MOUNTED
AC 264 - 333*
AC 264 - 633*
75x75x633'x3'x2.5'
160x75x636'x3'x2.5'
10
10
AC 262 - 033*
AC 262 - 063*
75x753'x3'
160x756'x3'
12
10
SURFACE SWITCH BOX
AC 206 - 020AC 206 - 025
2025
12575
ROUND ELBOW
AC 201 - 020
AC 201 - 025
20
25
50
50
ROUND TEE
AC 207 - 020*
AC 207 - 025*
20
25
125
75
INSPECTION ELBOW
AC 202 - 020*
AC 202 - 025*
20
25
50
25
INSPECTION TEE
40
20
AC 208 - 020*
AC 208 - 025*
20
25
INSPECTION BENDuPVC SOLVENT CEMENT
Code Size Std. Pkg.
TSWTIN-250
TSWTIN-500
TSWTIN-1000
250 ML
500 ML
1000 ML
24
12
12
*EXPANSION JOINT
-
8/18/2019 Astral Wire Guard Pipes
9/12
08www.astralcpvc.com
INSTALLATION
Open : Use clamps to hold.
Concealed : Make a slot of appropriate width in wall, fix pipe in slot and cover with mortar.
INSTALLATION PROCEDURES
CAPACITY OF CONDUITS
Capacity of conduits for simultaneous drawing of single corePVC insulated cable for a straight run upto 10m without bends.
TABLE - 01Capacity of conduits for simultaneous drawing of single corePVC insulated cables for a run upto 10m with one bend.
TABLE - 02
RECOMMENDED PRACTICE
TMASTRAL WIRE GUARDconstructed that it will be possible to bend the conduiteasily with the aid of bending spring and all conduits andconduit fittings are of unthreaded type. The number ofsingle core, PVC insulated non-sheathed cables run in oneconduit shall be such that it permits easy drawing of the
non-metallic conduits are so cables. The actual number ofshall not be greater than the number given in theappropriate table. Where different sizes of cables aredrawn into a conduit, the number and sizes of cablesinstalled shall be selected in accordance with the methoddetailed in tables. A separate insulated earth wire shall bedrawn into all rigid non-metallic conduits.
cables drawn into any conduit
Nominal Cross Sectional
area of conductor
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.070.0
Size of Conduit (mm)
11
8
5
4
2
2
-
-
--
-
-
10
7
4
3
2
-
--
-
-
-
13
7
6
4
3
2-
-
-
-
-
10
9
5
4
32
-
-
-
-
-
-
10
7
54
20 25 32 40 50-
-
-
-
-
-
-
10
76
63
Nominal Cross Sectional
area of conductor
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.070.0
Size of Conduit (mm)
8
6
4
3
-
-
-
-
--
-
-
8
6
3
2
-
-
--
-
-
-
11
6
5
3
2
--
-
-
-
-
8
7
4
3
2-
-
-
-
-
-
12
18
6
43
20 25 32 40 50-
-
-
-
-
-
-
9
75
63
Capacity of for simultaneousdrawing of single core PVC insulated cables for a run upto10m with 2 bends
TMASTRAL WIRE GUARD
TABLE - 03
Nominal Cross Sectional
area of conductor
1.5
2.5
4.0
6.010.0
16.0
25.0
35.0
50.0
70.0
Size of Conduit (mm)
6
4
3
2-
-
-
-
-
-
11
8
6
42
2
-
-
-
-
-
-
-
84
3
2
-
-
-
-
-
-
116
5
3
2
-
-
-
-
-
-10
9
5
4
3
2
20 25 32 40 50
TABLE - 04
Nominal Cross
Sectional area
of conductor mm²
Cable Factor
1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0
22 30 43 58 105 121 193 253 342 451
CABLE FACTOR
For each size of cable it is intended to use, obtain the appropriate factor from Table 4. Add all the cable factors so obtained andcompare with the conduit factor given in Table 5.The conduit size which will satisfactorily accommodate the cables is that size having a factor equal to or exceeding the sum of thecable factor.
-
-
-
--
12
7
6
4
3
63
TABLE - 05TM
ASTRAL WIRE GUARD FACTOR
Conduit Size mmupto 10 mtr.
Without Bend
Upto 10 mtr.
with 1 Bend
Upto 10 mtr.
With 2 Bend
20
244
196
141
32
783
643
474
25
442
358
260
40
1092
883
646
50
1943
1571
1149
63
2715
2429
1527
-
8/18/2019 Astral Wire Guard Pipes
10/12
09 www.astralcpvc.com
All conduit pipe and fittings expand and contract with
changes in temperature. All materials expansion and
contraction rates are represented by coefficients of thermal
expansion. A general rule of thumb is that for every 100°Ftemperature change in a 100 ft. run of PVC conduit; the
conduit will undergo 3.6" of expansion or contraction.
EXPANSION AND CONTRACTION
USE OF EXPANSION JOINTS
In installations where the expected temperature variation
exceeds 25°F expansion joints must be used. An expansion
joint consists of two tubes, one telescoping inside another.
When installing expansion joints alignment of the piston and
barrel is important. Straps should be placed approximately
one foot on either side of the joint to ensure that anymovement is directed squarely into the joint.
LOCATION OF EXPANSION JOINTS
ONE EXPANSION JOINT
TWO EXPANSION JOINTS
Proper functioning of an expansion joint depends on threeprocedures :• The correct placement of the expansion joint.• The proper installation of rigid PVC conduit and the
expansion joint.• The proper placement and fastening of support straps.
If only one expansion joint is needed between two boxes, thebarrel of the joint should be rigidly fastened close to the firstbox. Rigid PVC conduit should then be loosely supported withstraps, allowing the conduit to move freely as it expands andcontracts.
If two expansion joints are needed, the joints should be firmly
fastened back to back at the center of the run. Rigid PVCconduit should be loosely supported with straps, allowing theconduit to move freely as it expands and contracts.
TWO EXPANSION JOINTS (ALTERNATIVE)
THREE OR MORE EXPANSION JOINTS
Alternatively, the center of the run and the two expansion joints (located at the boxes) should be rigidly fastened. Allother support straps should be loosely fastened.
If more than two joints are needed in a very long run, theyshould be put in a series, one after the other. Each barrelmust be rigidly fastened while conduit is loosely supportedwith straps allowing the conduit to move freely as it expandsand contracts. When installed in a series, each section actsindependently of the other.
When expansion joints are required the following steps
should be followed :
Use the following formula to calculate the total expected
expansion in the run.
Total Expansion =
The expansion joints should then be installed at even
intervals throughout the run.
Number of Joints = Total expansion
4
The expansion joint must be installed to allow both
expansion and contraction of the conduit run. Because
installation temperatures may vary, the piston setting must
be determined. The correct piston opening is determined
using the following formula :
Piston (in) =
max temperature (°F) - installing temperature (°F) x 4
Temperature change (°F)
1. DETERMINE NUMBER OF JOINTS REQUIRED :
2. DETERMINE PISTON OPENING
Length of Run Ft.
Total Temp.Change °F 0.36X X
10010 X
PVC Pipe Length VariationDue to Temperature Change (°F)
-5Coeffecient = 3.6 x 10 in./ft./ F°
T e m p e r a t u r e C h a n g e i n ° F
Length Variation 100/ft. of Pipe
120
110
100
90
80
70
60
50
40
30
20
10
010 2 3 4 5
EXPANSION AND CONTRACTION
-
8/18/2019 Astral Wire Guard Pipes
11/12
10www.astralcpvc.com
stored at the job site on level ground in the unit package
(skids) provided by the supplier. Caution must be
exercised to avoid compression, damage or
deformation. When unit packages are stacked, care must
be used to ensure that the weight of the upper unit dose
not cause deformation to pipe in the lower units.
ASTRAL WIRE GUARD™ pipe must not be stored in tightly
enclosed areas subject to elevated temperatures. or
close to heat producing sources such as boilers, heaters,
steam lines, engine exhaust etc. Exposure to excessive
temperatures will result in distortion and deformation of
pipe.
•
•
•
•
•
•
•
Stack pipe lengths:
- either on a flat base or on level ground.
Ideally, stacks should contain one diameter pipe size
only. Where this is not possible, stack largest diameter
pipes at base of stack. Small pipes may be nested inside
larger pipes.
Store all materials in well ventilated, shady conditions.
If stored in the open for long periods or exposed tostrong sunlight, cover the stack with opaque sheeting.
Store fittings under cover. Do not remove from cartons
or packaging until required.
Store solvent cement and cleaning fluid in a cool place
out of direct sunlight and away from any heat source.
1. CUT PIPE :
2. REMOVE BURR AND BEVEL :
CLEAN :
3. CEMENT :
4. JOIN PIPE AND FITTINGS :
Cut pipe square. As joints are sealed at the
base of the fitting socket. An angled cut may result in jointfailure.
Remove all burr from inside
and outside of pipe with a knife-edge file, or deburring
tool. Chamfer (bevel) the end of the pipe 10° -15°
Remove surface dirt, grease, or moisture with a
clean dry cloth.
Apply a full even layer of cement to the outside
of a pipe and medium layer of cement to the inside of a
fitting.
Assemble pipe and fitting
socket till it contacts socket bottom. Hold pipe and fitting
together until the pipe does not back out. Remove
excessive cement from the exterior. A properly made joint
will show a continuous bead of cement around the
perimeter.
JOINING METHOD
DO'S & DON'TS
DO'S
•
•
DON'TS
•
•
Always insist to use ASTRAL uPVC solvent cement for
making joints.
Cut the pipe straight, as improper cut may lead to
joint failure.
Do not insert the pipe into socket of fitting without
chamfering. This can disturbing while wire pulling.
Do not install pipeline without properly placed pipe
clips. This is required to ensure efficient working of
the system.
®
HANDLING
•
•
•
ON-SITE STORAGE
•
Take all reasonable care when handling
ASTRAL WIRE GUARD™ pipes particularly in very cold
conditions when the impact strength of the material is
reduced.
Do not throw or drop pipes, or drag them along hard
surfaces.
In case of mechanical handling, use protective slings
and padded supports. Metal chains and hooks should
not make direct contact with the pipe.
ASTRAL WIRE GUARD™ Conduit pipe and fittings may
be stored indoors or outside. If stored outside, pipe and
fittings should be protected from direct exposure to
sunlight and pipe should be properly supported in
storage to prevent sagging or bending. Pipe should be
GOOD SITE PRACTICE
JOINING METHOD
-
8/18/2019 Astral Wire Guard Pipes
12/12
AWG/PCG/00 0
REV:00/09/14
d e s i g n @ s p e c t r u m
a d v t . i n
All information contained in this manual is given in good faith and believed to be accurate and reliable. But because of many factors which are outside our knowledge and control and affectuse of product, no warranty is given or is to be implied with respect to such information, nor we offer any warranty of immunity against patent infringement. No responsibility can be acceptedfor any error, omissions or incorrect assumptions. Any specification can change without prior notice.
Follow us on : App Available on :
Authorised Distributor :
CIN : L25200GJ1996PLC029134
REGISTERED & CORPORATE OFFICE:
207/1, Astral House, B/h. Rajpath Club,
Off. S.G. Highway, Ahmedabad-380 059,
Gujarat, India.
Phone : +91 79 6621 2000
Fax : +91 79 6621 2121
E-mai l : [email protected]
Website : www.astralcpvc.com
ASTRAL POLY TECHNIK LIMITED
ASTRAL IS ISO 9001:2008REGISTERED COMPANY
BRANCH OFFICES:Mumbai : Phone : (022) 2686 2227 E-mail : [email protected] Delhi : Phone : (011) 2616 8156 E-mail : [email protected] : Telefax : (080) 2661 7236 E-mail : [email protected] : Telefax : (040) 2790 0023 E-mail : [email protected] : Phone : (044) 4350 6384 E-mail : [email protected]
Jaipur : Phone : (0141) 2360 236 E-mail : [email protected] : Phone : (0522) 2728 844 E-mail : [email protected] : Phone : (0484) 3328 156 E-mail : [email protected]
STRONG NAHIN, ASTRAL STRONG!! TM
OTHER PIPING SYSTEMS
| ASTM UPVC PIPING SYSTEM | uPVC DRAIN WASTE & VENT SYSTEM | LIGHT WEIGHT FOAMCORE UPVC PIPES |
| CPVC PIPING SYSTEM FOR INDUSTRIES | ALCA PLAST SHOWER CHANNELS |
| CPVC PIPING SYSTEM FOR FIRE SPRINKLERS | CPVC-AL-CPVC MULTILAYER COMPOSITE PIPE |
| CPVC PLUMBING SYSTEM FOR HOT & COLD WATER | THE LEADING SOUNDPROOF SOIL & WASTE SYSTEM |
| uPVC PIPES FOR DRAINAGE & SEWERAGE APPLICATIONS | CLAMPS, HANGERS AND ELECTRICAL FLUSH BOXES |
| uPVC PIPE FOR AGRICULTURE & WATER TRANSPORT SYSTEM | uPVC CONVENTIONAL SYSTEM FOR SOIL WASTE & RAIN WATER |
| HEAVY METAL & LEAD FREE COLUMN PIPES FOR SUBMERSIBLE PUMPS |