ata 71 cfm56 3
DESCRIPTION
Boeing 737-3/-4/-500TRANSCRIPT
![Page 1: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/1.jpg)
![Page 2: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/2.jpg)
![Page 3: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/3.jpg)
![Page 5: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/5.jpg)
![Page 6: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/6.jpg)
CFM56 CHARACTERISTICS
![Page 7: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/7.jpg)
Series 1/200 3/4/500
Engine JT8-17A CFM56-3
Max time limit for take-off or go-around
thrust:
5 min 5 min *
Max N1 102.4% 106%
Max N2 100% 105%
Max EGT's:
Take-off (5 min limit) 650°C 930°C
Continuous 610°C 895°C
Start 575°C 725°C
Oil T's & P's
Max temperature 165°C 165°C
15 minute limit (45 minute limit on NG) 130-165°C 160-165°C
Max continuous 130°C 160°C
Min oil press 40psi 13psi (warning
light),26psi (gauge)
Min oil quantity (at dispatch) 2.25 USG 60% full (12 US Quarts) **
Starting pressures prior to starter
engagement
30psi -1/2psi per 1000' amsl
Starter duty cycle 1st attempt: 2min on, 20sec off
2nd & subsequent attempt: 2min on, 3min off
LIMITATIONS
![Page 8: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/8.jpg)
ENGINE HAZARD AREAS - IDLE POWER
![Page 9: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/9.jpg)
ENGINE HAZARD AREAS - TAKEOFF POWER
![Page 10: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/10.jpg)
ENTRY/EXIT CORRIDOR (LOW IDLE)
![Page 11: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/11.jpg)
HOW TO APPROACH DURING ENGINE MAINTENANCE RUN
![Page 12: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/12.jpg)
POWERPLANT NOISE AREA
![Page 13: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/13.jpg)
ENGINE DIMENSIONS
![Page 14: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/14.jpg)
ENGINE GROUND CLEARANCE
![Page 15: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/15.jpg)
ON CONDITION MAINTENANCE
![Page 16: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/16.jpg)
POWERPLANT COWLING
![Page 17: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/17.jpg)
INLET COWL
![Page 18: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/18.jpg)
24 BOLTS AND 2 ALIGNMENT PINS AT 3
AND 9 O´CLOCK POSITIONS
INLET REMOVAL AND INSTALLATION
![Page 19: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/19.jpg)
FAN COWL
![Page 20: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/20.jpg)
FAN THRUST REVERSER COWL
![Page 21: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/21.jpg)
THRUST REVERSER COWL OPENING
CAUTION: THE WING LEADING EDGE
FLAPS MUST BE RETRACTED PRIOR
TO OPENING THE THRUST REVERSER
COWL TO PREVENT DAMAGE
EQUIPMENT.
![Page 22: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/22.jpg)
ACTUATOR LOCK ASSEMBLY
![Page 23: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/23.jpg)
ENGINE MOUNTS
![Page 24: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/24.jpg)
FWD ENGINE MOUNT & THRUST LINK
![Page 25: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/25.jpg)
AFT ENGINE MOUNT
LOCATED AT THE
12 O´CLOCK
![Page 26: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/26.jpg)
POWER PLANT DRAINS
![Page 27: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/27.jpg)
FAN COMPARTMENT DRAINAGE
![Page 28: Ata 71 cfm56 3](https://reader034.vdocument.in/reader034/viewer/2022050621/548104ccb37959c22b8b465e/html5/thumbnails/28.jpg)
CORE COMPARTMENT DRAINAGE