atomic clocks with cold atomsatomic clocks with …atomic clocks with cold atomsatomic clocks with...

24
Atomic clocks with cold atoms Atomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630) Observatoire de Paris, France Quantum engineering with photons, atoms and molecules Les Houches, February 2005

Upload: others

Post on 06-Aug-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Atomic clocks with cold atomsAtomic clocks with cold atomsAtomic clocks with cold atoms

Pierre LemondeBureau National de Métrologie – SYRTE (UMR CNRS 8630)

Observatoire de Paris, France

Quantum engineering with photons, atoms and moleculesLes Houches, February 2005

Page 2: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Atomic FountainsAtomic FountainsAtomic Fountains

10 fountains in operation (SYRTE, PTB, NIST, USNO, PENN state, ON, IEN, NPL) with an accuracy of ~10-15. Several projects (NIJM, NIM, KRIISS, VNIIFTRI...)

See e.g. Proc. 6th Symp. Freq. Standards and Metrology (World Scientific 2002)

BNM-SYRTE (F) PTB (D) NIST (USA)

Page 3: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Atomic fountains: Principle of operationAtomic fountains: Principle of operationAtomic fountains: Principle of operationSelection

3

2

1

Nat ~2×109

σr ~1.5−3mmT ~1µK∆V ~2 cm.s-1

Vlaunch ~ 4m.s-1

H ~1mT ~500ms

Tc ~0.8-2s Detection

Page 4: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

vacuum chamber and cavityvacuum chamber and cavityvacuum chamber and cavity

The 2 outermost shields are removed

Interrogation region with magnetic and thermal shields

Compensation coils

Collimator for molasses beams

Optical molasses

Page 5: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

optical benchoptical benchoptical benchLaser diode based system, can be made compact and reliable

External cavity diode laser

Acousto-optic modulator

Optical fibers

Cs vapor cell

Injection locked diode laser

Page 6: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

-100 -50 0 50 1000.0

0.2

0.4

0.6

0.8

1.0

-1.0 -0.5 0.0 0.5 1.00.0

0.2

0.4

0.6

0.8

1.0

detuning (Hz)

0.94 Hz

trans

ition

pro

babi

lity P

NO AVERAGING

ONE POINT = ONE MEASUREMENT OF P

Ramsey fringes in atomic fountainRamsey fringes in atomic fountainRamsey fringes in atomic fountain

We alternate measurements on bothe sides of the central fringe to generate an error signal, whichis used to servo-control the microwave source

Fluctuations of the transition probability:

Page 7: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Frequency stability with a cryogenic Oscillator Frequency stability with a cryogenic Oscillator Frequency stability with a cryogenic Oscillator With a cryogenic sapphire

oscillator, low noise microwave synthesis

(~ 3×10-15 @ 1s)

FO2 frequency stability

This stability is close to the quantum limit. A resolution of 10-16 is obtained after 6 hours of integration. With Cs the frequency shift is then close to 10-13!

Page 8: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Fountain AccuracyFountainFountain AccuracyAccuracyFO1FO2(Rb)FO2(Cs)Fountain (BNM-SYRTE)

0.0(3.0)0.0(3.0)0.0(3.0)Residual Doppler effect

-3.3(3.3)0.0(2.0)-4.3(3.3)Microwave leaks, spectral purity, synchronous perturbations.

0.0(1.0)0.0(1.0)0.0(1.0)Collisions with residual gaz.

0.0(1.4)0.0(1.4)0.0(1.4)Recoil0.0(1.0)0.0(1.0)0.0(1.0)Neighbouring transitions.

7.5

-197.9(2.4)

-162.8(2.5)1199.7(4.5)

7

0.0(1.0)

-127.0(2.1)3207.0(4.7)

-357.5(2)Collisions + cavity pulling

-168.2(2.5)Blackbody radiation1927.3(.3)second order Zeeman

6.5Total

Effect Shift and uncertainty (10-16)

Frequency difference between FO1 and FO2: 3 10-16

Page 9: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Collisional shift measurementCollisionalCollisional shift measurementshift measurement

Launching

Sweeping

Pushing0 1 2 3 4

0

2

4

6

Rab

i Fre

quen

cy (k

Hz)

Time (ms)100% 50%

|->

|+> |3,n>

|4,n-1>

|4,n-1>

|3,n>

δ

0 1 2 3 4

-5

0

5

Det

unin

g (k

Hz)

Time (ms)

By performing the internal state selection with adiabatic passage, we vary the atomic density by a factor of 2 without changing velocity and position distribution

Cold collisions then only depend on the atomic number

To measure the cold collision shift in quasi real time

We alternate measurements with full or interrupted adiabatic passage (produces n or n/2) F. Pereira Dos Santos et al., PRL

89,233004 (2002)

Page 10: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

The “adiabatic passage method”: ExperimentsThe “adiabatic passage method”: ExperimentsThe “adiabatic passage method”: Experiments

We have a practical realization of two atomic samples with a density ratio precisely equal to 1/2

Extrapolation of the collisionalshift:

MEASURED

The value and the stability of the ratio between 50% and 100% configurations is monitored during each measurement. We find:

Page 11: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

BNM-SYRTE fountain ensembleBNMBNM--SYRTE fountain ensembleSYRTE fountain ensemble

Page 12: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

100 1000 10000

1E-16

1E-15

1E-14

2.83 10-14

4.13 10-14

stab

ilité

de

fréqu

ence

temps (s)

FO1 FO2 Difference

5.01 10-14

Frequency comparisons between fountainsFrequency comparisons between fountainsFrequency comparisons between fountains

Page 13: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Below 10-16: Two possible waysBelow 10Below 10--1616: Two possible ways: Two possible ways

0

1

atomic resonancemacroscopic oscillator

atoms

interrogation

correction

atomic quality factor

natural width-Fourier limit, long interaction time-low oscillator spectral width

-Large atom number-low noise detection scheme-low noise oscillator

-as high as possible

Atomic transition in the optical domain

A clock in space

+ transition should be insensitive to external perturbations-low

Page 14: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Optical frequency standards ?Optical frequency standards ?Optical frequency standards ?

Frequency stability :

Increase (x 105)

!!!!!!!!!Optical fountain at the quantum limit

Frequency accuracy: most of the shifts (expressed in absolute values) don't dependon the frequency of the transition (Collisions, Zeeman...).

-Ability to compare frequencies (now solved with femto)

-Recoil and first order Doppler effect (trapped ion clocks)

-Interrogation oscillator noise conversion (Dick effect).

Three major difficulties

The best optical clocks so far exhibit frequency stabilities in the 10-15 τ -1/2 range togetherwith an accuracy around 10-14.

Page 15: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Optical lattice clockOpticalOptical latticelattice clockclock

3P01

461 nm

689 nm

698 nm(87Sr: 1 mHz)

1S0

1P1

3S1688 nm

679 nm

λtrap

λtrap

Clock transition 1S0-3P0 transition Katori, Proc. 6th Symp. Freq. Standards and Metrology (2002)Pal’chikov, Domnin and Novoselov J. Opt. B. 5 (2003) S131Katori et al. PRL 91, 173005 (2003)

Combine advantages of single trapped ion andFree fall neutral atoms optical standards

Other possible atoms: Hg, Yb, Ca, MgWhat is the required depth of the lattice (hyperpolarisability, available power...) ?

Page 16: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Periodic PotentialPeriodic PotentialPeriodic Potential

Eigenstates organize in bands and write , with n the band number and q the quasi-momentum

one restricts to the first Brillouin zone ]-kl,kl]

Eigenstates are delocalized over the whole lattice

U0=0 Eigenstates are plane waves

Page 17: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Periodic PotentialPeriodic PotentialPeriodic Potential

Eigenstates organize in bands and write , with n the band number and q the quasi-momentum

one restricts to the first Brillouin zone ]-kl,kl]

U0≠0 plane waves separated by 2kl are coupled by Hext

Eigenstates are delocalized over the whole lattice

Energy scale (Sr)

Page 18: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Spectroscopy in a latticeSpectroscopy in a latticeSpectroscopy in a lattice

q q+ks

Absorption of a photon: translation of the atomic momentum by ħks

Page 19: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Spectroscopy in a latticeSpectroscopy in a latticeSpectroscopy in a lattice

Transitions are shifted by ~ width of the band: Residual Doppler/recoil)

Atoms have to be prepared in the ground bandU0 has to be high : 50-100 Er High order effects, Hg, can we do better ?

Page 20: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

A deep lattice is needed...A deep lattice is needed...A deep lattice is needed...

Problem

Page 21: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Though...Though...Though...

Solution

Page 22: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Effect of gravityEffect of gravityEffect of gravity

g=0

Resonant tunnel effect ⇒ delocalization

g≠0

Non-resonant tunnel effect ⇒localization

For Sr: ∆g~1 kHz

Page 23: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

Wannier-Stark statesWannierWannier--Stark statesStark states

couples |q> states with each other (Bloch oscillations)

Long-lived metastable states separated by

Page 24: Atomic clocks with cold atomsAtomic clocks with …Atomic clocks with cold atomsAtomic clocks with cold atoms Pierre Lemonde Bureau National de Métrologie – SYRTE (UMR CNRS 8630)

unshifted carriersymmetric sidebands: possibility to use a much shallower traps (~10 Er)

Spectroscopy of W-S statesSpectroscopy of WSpectroscopy of W--S statesS states