attention - rockwellautomation.com · disconnect switch installation (cont'd) (4) - 5/16-18...
TRANSCRIPT
Table of Contents Page
Quick Installation Guide - Disconnect Switch Installation 2,3 - Disconnect Handle Installation 3 - Cable Mechanism Installation 4 - Connecting Rod Adjustment Procedure 5
Conversion from Right Hand to Left Hand Operation 6
Enclosure Without Handle Cutout 7 - Locate Handle - Drill Handle Holes
Door Catch Mounting Bracket Installation 8
Trailer Fuse Block Installation (600A) 9
Fuse Clip Installation (600A) 10
Bulletin 1494C Cable Operated Disconnect Switch Kit Components 11 Bulletin 1494C Cable Operated Disconnect Switch Kit Optional Accessory List 12
ATTENTION: The following procedures are critical to the proper operation of the disconnect handle and switch. Failure to follow these steps can result in damage to the equipment and/or serious injury or death to the operator.
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
G. Ushakow 7-30-077-30-07
7-30-07
M. JutzJ. Koziczkowski
ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing. Follow NFPA 70E requirements. Install in suitable enclosure. Keep free from contaminants.
Bulletin 1494C Cable Operated Disconnect Switch Kit (600A)Installation Instructions(Cat 1494C- _ _ _ Series 2 : 600A)
42052-190-01 (1)Printed in U.S.A.
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
1 13
QUICK INSTALLATION GUIDE
Disconnect Switch Installation
Enclosure with Right Hand Flange Enclosure with Left Hand Flange
Enclosure with Right Hand Flange Enclosure with Left Hand Flange
(2)
1
IMPORTANT: When locating the 600A switch, verify that the minimum diameter for the loop of the cable between the switch mechanism and handle mechanism is not less than 16 inches.Any reduction to the diameter of the bend loop for the cable will reduce the efficiency of the cable system, and create additional drag and friction within the cable conduit.
IMPORTANT: Verify that the cable assembly does not interfere with any mechanical and moving parts. Keep the cable conduit a minimum of 1/2" from all heat sources and current carrying terminals, fuses, transformers, etc.
Locate switch with right hand mechanism
8-1/4"
15"
(4) - 9/32" Dia.Mounting Holes
8-1/4"
15"
(4) - 9/32" Dia.Mounting Holes
1a
Locate switch with left hand mechanism1b
16" Dia. Minimum 16" Dia. Minimum
16" Dia. Minimum16" Dia. Minimum
8-1/4"
15"
(4) - 9/32" Dia.Mounting Holes
8-1/4"
15"
(4) - 9/32" Dia.Mounting Holes
2 13
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
(3)
2
4 5
3
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
3 13
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
Disconnect Switch Installation (Cont'd)
Rotate crossbar to closed position. Assemble the cable mechanism bracket to the disconnect switch.
Turn the connecting rod clockwise (approximately 9 - 10 turns) until jam nuts touch drive bar
Turn the connecting rod counter-clockwise (less than 1 turn) until hole in threaded rod aligns with hole in cable mechanism lever.
Drive Bar
Jam Nuts
1
90 - 130 lb-in
ThreadedRod
Cable Mechanism Lever
90 - 130 lb-in
(4)
Disconnect Switch Installation (Cont'd)
(4) - 5/16-18 threadforming screws provided with
disconnect switch.
7
1Assemble disconnect switch assembly to mounting plate.6 Attach threaded rod to cable mechanism lever.
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
4 13
Cable Mechanism Installation3
NOTE: Apply grease from capsule to gasket or grooveto retain gasket to handle.
Disconnect Handle Installation
Install gasket.1 2 3
2
7-11 lb-in
Install handle and mechanism bracket. Install defeater lever.
(Right HandFlange MountedShown)
60 - 80 lb-in
1 Verify that disconnect switch and handle are in the "ON" position.
2 Rotate connecting rod (clockwise) into drive bar until it begins to exit the drive bar (approximately 18 full turns).
1
2
ThreadedRod
Cable Mechanism Lever
90 - 130 lb-in
90 - 130 lb-in
CLOSED
(5)
3
5
4
ATTENTION: CHECK FOR PROPER OPERATION. Upon completion of the installation instructions, no further adjustment of the cable mechanism is required.
5 13
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
Cable Mechanism Installation (Cont'd)3Align connecting rod with primary link.
Turn disconnect handle "OFF" and install handle mechanism spring.
Connecting Rod Adjustment Procedure4"ON" Position➊ Move disconnect handle to the "ON" position.
➋ If switch does not fully close, return handle to "OFF" position.
➌ Remove link spring hitch pin and disengage the connecting rod from the primary link.
➍ Turn connecting rod counter-clockwise (1 or more) full turns.
➎ Re-engage connecting rod in primary link of handle, insert hitch
pin and re-test
➏ Repeat ➊ - ➎ as necessary.
➐ Re-install link spring.
"OFF" Position➊ Move disconnect handle to the "OFF" position.
➋ If switch does not fully open, return handle to "ON" position.
➌ Remove hitch pin and link spring, then disengage the connecting rod from the primary link.
➍ Turn connecting rod clockwise (1 or more) full turns.
➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test.
➏ Repeat ➊ - ➎ as necessary.
➐ Re-install link spring.
Install hitch pin clip Hitch Pin Clip
ConnectingRod
Primary Link
(6)
1
2
3
90 -130 lb-in
Remove drive mechanism from right side of switch(3) - 5/16 - 18 Hex Head Screws with disconnect switchin the "OFF" position.
Rotate crossbar to closed position.
Reinstall drive mechanism on left side of switch
Conversion from Right Hand to Left Hand Operation (If Required)
IMPORTANT: Switch conversion to left-hand operation requires left-hand cable mechanism.
ATTENTION: With switch in the "CLOSED" position, drive mechanism should align with crossbar.
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1029855
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
6 13
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
(7)
Enclosure without Handle Cutout
1
Top Handle Hole
Top Handle Hole
Square corners orup to 1/4" radius
Locate Handle
Right Hand Flange Left Hand Flange
(2) .328 Dia. Holes
1/4"
1/2"
Drill Handle Holes2
● Enclosures with a Flange Thickness less than 3/16" use dimensions below to install disconnect handle.
6-1/2"5-1/2"
5/16"
18-3/16" 18-3/16"
1-3/8" 1-3/8"1-1/8" 1-1/8"
7 13
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
(8)
8 13
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
Door Catch Bracket Installation Right hand installation shown (for left hand installation follow similar procedures)
Top Handle Hole
Door CatchMounting
Bracket
Door CatchMountingBracket
Right Hand Flange Left Hand Flange
1 - 1/8"
1 - 3/8"
Enclosure Door Flange Thickness K
1 - 5/8"
Enclosure Base
TOP VIEW
Door Catch Mounting Bracket:● Provided with projections for welding.● Projections can also be used as a guide for drilling holes.● Can be used as a template to drill corresponding holes in the enclosure door. ● User to supply the hardware for fastening the bracket. ● Fasteners must provide the degree of ingress protection for the environmental rating of the enclosure. ● The bracket hardware must be inaccessible to unauthorized personnel.
Dimension K (3/4" to 1")● When using large disconnect handle kit only (1494F-M2 or -S2), use door catch provided with handle kit.● When using large disconnect handle kit and small door hardware kits (1494V-L1, -LL1, -L2 or -LL2), use door catch provided with door hardware kit.
Dimension K (1-1/8" to 1-3/8")● When using large disconnect handle kit and large door hardware kits (1494V-L3 or -LL3), use door catch provided with door hardware kit.
Door CatchMounting Bracket
Door CatchMounting Bracket
Door Catch
Door Catch
Top
18-3/16"
1-3/8" 1-3/8"1-1/8" 1-1/8"
18-3/16"
3-3/4"
1-5/8"
3-3/4"
1-5/8"
(9)
Trailer Fuse Block Installation (Switch Rating 600A)Note: Not required for non-fusible disconnect switch applications.
Note: Terminal bolts need to be moved from disconnect switch load terminals to fuse block.
Note: Refer to instructions provided with separately mounted fuse blocks (Catalog Numbers 1491-N621 and 1491-R621).
1 2Trailer Fuse Block Location (400A Class H, J, R Fuses)
Trailer Fuse Block Location (600A Class J Fuses)
3 Trailer Fuse Block Location (600A - 250V / 600V Class H, R Fuses)
400 Amp Trailer Fuse Block (1494V-FSV400)
Torque (lb-in)Fuse
1-3/4"4-1/4"1-1/8"
400400400
250600600
H/RH/R
J90-13022-37 175-200 275-305
Amps Voltage Class FuseClip
AFuseBlock
Lug toTerminal
Wireinto Lug
Torque (lb-in)Fuse
4-3/8"600 250 / 600 J 90-130300-350 175-200 275-305
Amps Voltage Class FuseBolt
AFuseBlock
Lug toTerminal
Wireinto Lug
600 Amp Trailer Fuse Block (1494V-FS600)
A
8-1/4"
6-3/4"
6-3/4"
2-13/16" 3"
3-3/16"3/16"
3"
A
6-3/4"
2-13/16"
3-15/16" 3-15/16"
8-1/4"
6-3/4"
3"3/8"
9 13
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
(10)
Fuse Clip Installation (Switch Rating 600A)
40 - 55 lb-in
400A Fuses (Class H, J, R) 600A Fuses (Class J)
600A Fuses (Class H, R)
2
1
4
3
2
Note: Refer to instructions provided with separately mounted fuse blocks (Catalog Numbers 1491-N621 and 1491-R621).
300 - 350 lb-in
300 - 350 lb-in
1
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
10 13
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
(11)
Disconnect Switch Kit Cat No.
Cable with Right Hand Mechanism1494C-CM13: 600A (4 Ft Cable)1494C-CM14: 600A (5 Ft Cable)1494C-CM15: 600A (6 Ft Cable)1494C-CM16: 600A (10 Ft Cable)
Cable with Left Hand Mechanism1494C-CMX13: 600A (4 Ft Cable)1494C-CMX14: 600A (5 Ft Cable)1494C-CMX15: 600A (6 Ft Cable)1494C-CMX16: 600A (10 Ft Cable)
CableMechanism
Bulletin 1494C Cable Operated Disconnect Switch Kit Components
Handle
Switch
Switch with Right Hand Mechanism 1494V-DS600 (600A)
Convertible in the field for Left Hand operation
1494F-M2 (7-1/2" Painted Metal) (400A / 600A)1494F-S2 (7-1/2" Stainless Steel) (400A / 600A)
FuseBlock
FuseClips
Mounted with Switch
1494V-FSV400 (400A Class H, J, R)1494V-FS600 (600A Class J)
400A Fuses
1401-N46 (Class H, J, 400A-250V, 400A-600V)1401-N55 (Class R, 400A-250V, 400A-600V)
600A Fuses
Class J - Bolts directly to switch and fuse block (no clips required)
Class H, R - Fuse clips included with separatelymounted fuse blocks Cat. Nos.1491-N621 and 1491-R621
Separately Mounted
1491-N621 (600A 250V / 600V Class H)1491-R621 (600A 250V / 600V Class R)
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
11 13
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
42052-190-01 (1)Printed in U.S.A.
Catalog Number and Description
ElectricalInterlock
AuxiliaryContact
LugConnectors
Optional Accessories(Installation Instructions
Included with Accessory Kits)
Switch with Right Hand Mechanism 1495-N34 (1-N.O./N.C.) *1495-N35 (2-N.O./N.C.) *
*Requires Adapter Kit 1495-N36
595-A (1-N.O.) (600A) *595-B (1-N.C.) (600A) *
*Requires Adapter Kit 595-N1
FuseCover
with Door
Switch and Fuse Block
1494R-N10 (CU Wire (2) - #1/0 - 350 MCM) (600A or 400A Fuse Block)(3 per kit)
1494R-N11 (CU Wire (1) - #1/0 - 500 MCM) (600A or 400A Fuse Block)(3 per kit)
1494R-N12 (CU Wire (2) - #1/0 - 350 MCM) (600A)(2 per kit)
SwitchRating
FuseClass
Fuse ClipRating
Cat No.
250V 600V
400A 400AH, J, R600A 1495-N61
600A ---- ----Non-Fusible 1495-N61
Separately Mounted Fuse Blocks
Available only for R.H. mounted disconnect switch.
600A 600AJ600A 1495-N61
600A 600AH,R600A N/A
BULLETIN 1494C (600A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-190OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
12 13
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
Bulletin 1494C Cable Operated Disconnect Switch Kit Optional Accessory List