audio video power conditioners · •cb = anodized black aluminum •aio = all in one panel board...
TRANSCRIPT
Audio Video Power Conditioners
Made In Canada
Setting a New Standard for Audio Video Power Conditioners
2
TORUS POWER: BUILT IN CANADA BY PLITRON
Torus Power: • Best of Class Performance
• Built with only CSA and UL Approved Components
• Field Inspected by Electrical Safety Authority (ESA) base evaluation on National Electric Code (NEC)
• Designed and Manufactured in Toronto, Ontario, Canada
• Over 100 manufacturing quality tests for every single Torus Power product.
Made In Canada
Plitron Manufacturing:
• 30 years of experience designing and manufacturing toroidal transformers for OEM customers
• Located in Toronto, Ontario, Canada
• Dedicated & Specialized R&D team
• Markets: • Audio and Video • Medical • Broadcast • Telecommunications • Computer • Green Energy / Energy Savings
3
AWARDS & ACCOLADES
Stereophile, Recommend Component 2012: Torus Power RM 20
CE Pro Magazine, Best Products of 2009: Torus Power CS 15 AVR
The World’s Best Audio System (TWBAS) 2012: Torus Power WM 100 BAL & AVR 20 CS
3
Home Theater & Sound, Reviewers Choice: Torus Power RM 10
CE Pro: Must Have Component: Torus Power RM 15
4
MARKETS
Home
Theater
Commercial
Theater
Corporate
Board Room
Professional
Audio Video
Audiophile
2-Channel Audio
Professional
Schools
5
Product Line Features
Additional Product Information: • 5 Year Warranty • Designed and Manufactured in North America
PING
Individual
ON ON
OFF
Control
Notification
TOROIDAL
ISOLATION
SMSS
AVR
True Isolation Noise
Filtration
High Instantaneous
Current Capability
Series Mode Surge
Suppression
Automatic Voltage
Regulation
Ethernet Monitoring
& Control
IS
RM
AVR Series
Series
Series
AVR
TOROIDAL
ISOLATION SMSS
6
TOROIDAL
ISOLATION
SMSS
AVR
True
Isolation
Noise
Filtration
High Instantaneous
Current Capability
Surge
Suppression
Voltage
Regulation
Ethernet Monitoring
& Control
Additional Product Information: • 5 Year Warranty • Designed and Manufactured in North America, Canada
1Cabinet Style: • RK = Rack Mount • CS = Brushed Aluminum
• CB = Anodized Black Aluminum • AIO = All In One Panel Board
• FM = Floor Mount with Plinth
PRODUCT FEATURES
Series: IS RM AVR AIO FM Amperage:
5A-20A @ 120V
5A-100A @120V
15A-90A @120V
40A-100A @ 120V 20A-50A @ 240V
200A-290A @ 120V 100A-145A @ 240V
Cabinet Style1: RK, CS,
CB RK, CS,
CB, WM RK, CS,
CB, WM 24 x 20A
Breaker Panel FM with Plinth
True Isolation from mains via Plitron
Toroidal Isolation Transformer Noise Filtering / Clean Power using
patented Plitron NBT technology High Instantaneous Current Capability Series Mode Surge Suppression (up to 6000V, 3000A, 1000 times)
Automatic Voltage Regulation (AVR & AVR2)
Remote Monitoring & Control
TVSS (Transient Voltage Spike and Surge
Suppression) Optional Optional Optional
TOROIDAL
ISOLATION
SMSS
AVR
TVSS
Features Matrix All Products
7
IS Series Premium Power Conditioning at Entry Level Prices
1. True Isolation • Torus Power provides true isolation from the external power
grid via Plitron toroidal isolation transformer.
2. Noise Attenuation - NBT • Narrow Bandwidth Technology uses the toroid as a low pass
filter. • Attenuation from 2kHz to 1MHz at 12dB/decade up to 500kHz. • Torus Power does not use passive current-limiting filter banks.
3. High Instantaneous Power on Demand • Torus Power can supply high levels of instantaneous current on
demand (up to 10x the current rating of the product) • Torus Power provides low source impedance and can draw stored
magnetic energy from the magnetic field of the toroid. • Dynamic loads like amplifiers perform better when they don’t
have to struggle to get sufficient power from the wall.
Model Max Current
Rating (A) Outlets
IS 5 5 6
IS 5 BX 5 6
IS 10 10 8
IS 10 BX 10 8
IS 15 15 10
IS 20 20 10
AVR
TOROIDAL
ISOLATION
True Toroidal
Isolation
Noise Filtration
High Instantaneous
Current Capability
8 8
4. Series Mode Surge Suppression (SMSS) • Meets IEE C62.41 1991 (6000V, 3000A, 1000 times) • Torus Power SMSS absorbs the surge in the toroid and slowly bleeds it
to the loads, preventing ground contamination. • Torus Power SMSS does not shunt surges to ground like MOVs. • SMSS uses all non-sacrificial components (does not require
replacement or repair after large surges )
Model Max
Current Rating (A)
Output Breaker
(A) Outlets
RM 2.5 2.5 - 4
RM 5 5 - 6
RM 10 10 - 8
RM 5 BX 5 - 6
RM 10 BX 10 - 8
RM 15 15 - 10
RM 20 20 - 10
RM 20 BAL 20 - 10
RM 45 BAL 45 3x20 18
RM 60 BAL 60 3x20 18 RM 75 BAL 75 4x20 24
RM 100 BAL 100 5x20 24
1. True Isolation from the external power grid. 2. Noise Attenuation using Plitron’s proprietary NBT Technology. 3. High Levels of Instantaneous Current on demand.
RM Series
TOROIDAL
ISOLATION
True Toroidal
Isolation
Noise Filtration
High Instantaneous
Current Capability
SMSS
Series Mode Surge
Suppression
9 9 9
Series Mode Surge Suppression (SMSS) • Meets IEE C62.41 1991 (6000V, 3000A, 1000 times) • Torus Power SMSS absorbs the surge in the toroid and slowly bleeds it
to the loads, preventing ground contamination. • Torus Power SMSS does not shunt surges to ground like MOVs. • SMSS uses all non-sacrificial components (does not require
replacement or repair after large surges )
IS Series Features • True Isolation from the external power grid. • Noise Attenuation using Plitron’s proprietary NBT Technology. • High Levels of Instantaneous Current on demand.
TOROIDAL
ISOLATION
True Toroidal
Isolation
Noise Filtration
Instantaneous
Current On
Demand
SMSS
Series Mode
Surge
Suppression
Model Max
Current Rating (A)
Output Breaker (A)
WM 45 BAL 45 3x20
WM 60 BAL 60 3x20
WM 75 BAL 75 4x20
WM 100 BAL 100 5x20
TOROIDAL
ISOLATION
True Toroidal
Isolation
Noise Filtration
High Instantaneous
Current Capability
SMSS
Series Mode Surge
Suppression
Wall Mount Products
RM Series
*Additional TVSS available on all WM models
10 10
RM Series Features • True Isolation from the external power grid. • Noise Attenuation using Plitron’s proprietary NBT Technology. • High Levels of Instantaneous Current on demand. • Series Mode Surge Suppression
Automatic Voltage Regulation (AVR) • Mains system voltage at 120V +/-5V • Normal operation with incoming voltage from 85V to 135V
Remote Monitoring & Control • Power conditions may be monitored on the Torus Power, or via any web
browser on the local network (Vi, Vo, I) • Email notification in the event of system fault • Power cycling (on/off) via web browser interface
Model Max
Current Rating (A)
Output Breaker
(A) Outlets
AVR 15 15 - 10
AVR 20 20 - 10
AVR 20 BAL 20 - 10
AVR 45 BAL 45 3x20 18
AVR 60 BAL 60 3x20 18
AVR 75 BAL 75 4x20 24
AVR 90 BAL 90 5x20 24
AVR Automatic Voltage
Regulation
Ethernet Monitoring
& Control
TOROIDAL
ISOLATION
True Toroidal
Isolation
Noise Filtration
High Instantaneous
Current Capability
SMSS
Series Mode Surge
Suppression
AVR Series Automatic Voltage Regulation
11 11
RM Series Features • True Isolation from the external power grid. • Noise Attenuation using Plitron’s proprietary NBT Technology. • High Levels of Instantaneous Current on demand. • Series Mode Surge Suppression
Automatic Voltage Regulation (AVR) • Mains system voltage at 120V +/-5V • Normal operation with incoming voltage from 85V to 135V
Model Max
Current Rating (A)
Output Breaker (A)
WM 45 BAL AVR 45 3x20
WM 60 BAL AVR 60 3x20
WM 75 BAL AVR 75 4x20
WM 90 BAL AVR 90 5x20
Remote Monitoring & Control • Power conditions may be monitored on the Torus Power, or via any web
browser on the local network (Vi, Vo, I) • Email notification in the event of system fault • Power cycling (on/off) via web browser interface
AVR Automatic Voltage
Regulation
Ethernet Monitoring
& Control
TOROIDAL
ISOLATION
True Toroidal
Isolation
Noise Filtration
High Instantaneous
Current Capability
SMSS
Series Mode Surge
Suppression
AVR Series Wall Mount Products
*Additional TVSS available on all WM models
12
AVR Automatic Voltage
Regulation
Ethernet Monitoring
& Control
TOROIDAL
ISOLATION
True Toroidal
Isolation
Noise Filtration
High Instantaneous
Current Capability
SMSS
Series Mode Surge
Suppression
Individual Outlet
Zone Control
Automatic
Reboot
Switch-On Delay
AVR2 Series Automatic Voltage Regulation 2
NEW IN AVR2 ON ON
OFF
PING
PING
AVR upgradable to AVR2 through Manufacturer
Individual
ON ON
OFF
Control
AVR Automatic Voltage
Regulation
Ethernet Monitoring
& Control
TOROIDAL
ISOLATION
True Toroidal
Isolation
Noise Filtration
High Instantaneous
Current Capability
SMSS
Series Mode Surge
Suppression
Scheduling &
Sequencing
Email Fault
Notification
Notification
4 Zones available in 15A and 20A models 7 Zones available in 45A to 90A models
WHAT’S INSIDE?
Input Breaker (on/off)
Medical Grade Duplex Outlets
Grounding Post
IEC Inlet
Series Mode Surge Suppression Board
Relay Card
Toroidal Isolation Transformer
12V Fault Notification
12V Trigger (on/off)
RS-232 (on/off)
Ethernet Port Rear Panel
Face Plate
Rear Panel
13
Rack/Shelf Mount AVR Products
Input Breaker (on/off)
LCD Display
14
WHAT’S INSIDE? Wall Mount Products
Relay Card
Series Mode Surge Suppression Board
Input
Toroidal Isolation Transformer
Output
Cooling Fan
Ethernet Port
RS-232
12V Fault Notification
12V Trigger (on/off)
TECHNOLOGY
TOROIDAL
ISOLATION
2. Noise Attenuation - NBT • Narrow Bandwidth Technology (NBT) uses the toroid
as a low pass filter. • Attenuation from 2kHz to 1MHz at 12dB/decade up to
500kHz. • Torus Power does not use passive current-limiting
filter banks to achieve attenuation.
3. High Instantaneous Current Capability • Torus Power can supply high levels of instantaneous
power. This is achieved through an optimally designed transformer which is capable of providing clean and least obstructed power flow.
• Dynamic loads like amplifiers perform better when they don’t have to struggle to get sufficient power from the wall.
6. Ethernet Monitoring & Control • Electrical parameters (Voltage In/Out & Current
Draw) may be monitored on the Torus Power, or via any web browser on the local network.
• Email Fault Notification in the event of system fault • Switch-On Safety Delay • Power cycling (on/off) via web browser interface (all
outlets for AVR, individual zones for AVR2) • Scheduler and Sequencer • Auto Reboot when internet is lost
5. Automatic Voltage Regulation (AVR) • Maintains system voltage at 120V +/-5V with
incoming voltage from 85V to 135V. • Start-up Delay as an additional safety feature to
protect against extreme voltage conditions. • Programmable automatic shut-off during extreme
voltage.
4. Series Mode Surge Suppression (SMSS) • Meets IEEE C62.41 1991 (6000V, 3000A, 1000 times) • Torus Power SMSS absorbs the surge in the toroid
and slowly bleeds it to the loads, preventing ground contamination.
• Torus Power SMSS does not shunt surges to ground like MOVs.
• SMSS uses all non-sacrificial components (does not require replacement or repair after large surges )
1. True Isolation • Torus Power provides true isolation from the external
power grid via Plitron toroidal isolation transformer.
AVR
SMSS
3. High Instantaneous Current Capability • Torus Power can supply high levels of instantaneous
current on demand (up to 10x the current rating of the product)
• Torus Power provides low source impedance and can draw stored magnetic energy from the magnetic field of the toroid.
• Dynamic loads like amplifiers perform better when they don’t have to struggle to get sufficient power from the wall.
15
TOROIDAL
ISOLATION
SMSS AVR
TECHNOLOGY
Individual Zone Control • Individually addressable outlet zones :
• 4 zones for 15A and 20A models • 7 zones for 45A, 60A, 75A & 90A models
• Available in AVR2 models
Auto Reboot • Outlet will automatically reboot if Torus Power
detects a loss of internet connection. • Designed to reboot the modem and/or router to
regain connection • Available in AVR2 models
Scheduler & Sequencer • Scheduler: Each zone may be programmed with 6 on
or off events per day, seven days per week. • Power-up sequencing with selectable delay times
between zones. • Scheduler remains active even when internet
connection is lost, so long as unit is powered. • Sequencing available via Scheduler as well • Available in AVR2 models
Switch-On Safety Delay • When power is restored or turned on, Torus power
waits 5 seconds prior to engaging the circuit to ensure safe line conditions.
• Available in AVR & AVR2 models
Email Fault Notification • Notification Email in event of extreme voltage • High Voltage is >135V for products with single phase
(120V) input, and > 270V for products with dual phase (2 x 120V, or 240V) input.
• Low voltage is defined as <85V for products with single phase (120V) input, and <170V for products with dual phase (2x120V, or 240V) input.
• Available in AVR & AVR2 models
PING
Individual
ON ON
OFF
Control
Notification
PING
Individual
ON ON
OFF
Control
Notification
AVR & AVR2 Series Ethernet Monitoring & Control Features
16
AVR Web Browser Online Interface AVR Status
Switch Power
Setup
Email Configuration
Network Configuration
17
BLOCK SCHEMATIC
18 18
Features Matrix
Additional Product Information: • 5 Year Warranty • Designed and Manufactured in North America, Canada
PRODUCT FEATURES
Series: IS RM AVR AIO FM Amperage:
5A-20A @ 120V
5A-100A @120V
15A-90A @120V
40A-100A @ 120V 20A-50A @ 240V
200A-290A @ 120V 100A-145A @ 240V
Cabinet Style1: RK, CS,
CB RK, CS,
CB, WM RK, CS,
CB, WM 24 x 20A
Breaker Panel FM with Plinth
True Isolation from mains via Plitron
Toroidal Isolation Transformer Noise Filtering / Clean Power using
patented Plitron NBT technology High Instantaneous Current Capability Series Mode Surge Suppression (up to 6000V, 3000A, 1000 times)
Automatic Voltage Regulation (AVR & AVR2)
Remote Monitoring & Control
TVSS (Transient Voltage Spike and Surge
Suppression) Optional Optional Optional
1Cabinet Style: • RK = Rack Mount • CS = Brushed Aluminum
• CB = Anodized Black Aluminum • AIO = All In One Panel Board
All Products
TOROIDAL
ISOLATION
SMSS
AVR
TVSS
• FM = Floor Mount with Plinth
19
AIO Features • True Isolation from the external power grid. • Noise Attenuation using Plitron’s proprietary NBT Technology. • High Levels of Instantaneous Current on demand. • Transient Voltage Spike and Surge Suppression (TVSS) • Industrial grade bolt-in breakers (24 x 20A) • 1” x 1.25” all copper buss bars
The All In One Panel Board brings together the Torus Power benefits with the footprint of an industrial grade distribution panel.
All In One Systems Custom Products
Transient Voltage
Spike & Surge
Suppression 6’
TOROIDAL
ISOLATION
True Toroidal
Isolation
Noise Filtration
Instantaneous Current
On Demand
TVSS
Model Nominal
Input Voltage (V)
Nominal Output Voltage (V)
Output Current
(A)
Power Rating (kVA)
AIO-5K-240 240 240 and/or 2x120 2x20 5 AIO-5K-208 208 240 and/or 2x120 2x24 5
AIO-7.5K-240 240 240 and/or 2x120 2x30 7.5 AIO-7.5K-208 208 240 and/or 2x120 2x36 7.5
AIO-12.5K-240 240 240 and/or 2x120 2x52 12.5 AIO-12.5K-208 208 240 and/or 2x120 2x60 12.5
20 20
Model Nominal Input
Voltage (V) Nominal Output Voltage (V)
Output Current Rating (A)
Weight (lbs.)
Power Rating (kVA)
FM-35K-230 230 240 and/or 2x120
145 724
35 FM-35K-240 240 145 FM-35K-230-TVSS 230
240 and/or 2x120 145
730 FM-35K-240-TVSS 240 145 FM-25K-230 230
240 and/or 2x120 100
612 25
FM-25K-240 240 100 FM-25K-230-TVSS 230
240 and/or 2x120 100
618 FM-25K-240-TVSS 240 100
The Floor Mount System combines protection, capacity, and fidelity.
FM Features • True Isolation from the external power grid. • Noise Attenuation using Plitron’s proprietary NBT
Technology. • High Levels of Instantaneous Current on demand. • Transient Voltage Spike and Surge Suppression (TVSS)
- optional
Floor Mount Systems Custom Products
Transient Voltage
Spike & Surge
Suppression
TOROIDAL
ISOLATION
True Toroidal
Isolation
Noise
Filtration
Instantaneous
Current On
Demand
TVSS
21
50A 100A 200A 300A 0A
5A – 20A
5A – 100A
15A – 90A
40A – 100A
100A – 290A
Current Capacity (Amps)
Current Rating by Series & Systems
FM Systems
AIO Systems
AVR Series
RM Series
IS Series
22
Made In Canada
Setting a New Standard for Audio Video Power Conditioners
Plitron Manufacturing 8-601 Magnetic Drive Toronto, Ontario M2J2J3, Canada www.toruspower.com www.plitron.com
Matthew Roher Business Development Manager - Torus Power [email protected] 416-667-9914 x248
CONTACT
Audio Video Power Conditioners
23
APPENDIX
24 24
UNDERSTANDING POWER APPENDIX A1: Incoming Power
Source: http://science.howstuffworks.com/environmental/energy/power.htm
Incoming Power: High levels of noise due to voltage shaping
(inverters & converters) and the growing number of noise-generating household devices (dimmers, non-linear power supplies, non-linear loads).
The effects of power line impedance become greater as the distance to the load increases. This can result in loss of power.
Inconsistent voltage levels (Sags, Brownouts, Surges and Spikes)
“Keeping voltage distortion, current harmonics, normal mode noise and common mode noise to a minimum in a power distribution system is absolutely necessary for reliable operation.”
-Arthur Kelm, Ground One Work Includes: Chief Engineer at Skywalker Sound, Technical Consultant to Walt Disney Imagineering, General
Manager & Technician at Record One Studios
Common Electrical Impurities APPENDIX A2: Incoming Power
25
Low Voltage / Brownout High Voltage
Noise*: Common Mode / Differential Mode
Voltage Spikes/Transients
Voltage Sag High Impedance:
Voltage Drops as Distance Increases
Clean Voltage Sine Wave
This pure 120V sine wave is required for every audio video system, especially high fidelity systems that are more discriminating.
*Motors and switching power supplies are the primary culprits for noise. Common Mode Noise is noise between the neutral and ground, Differential Mode Noise is noise between the neutral and line.
Line Neutral
Ground
Loss
Loss
26
THINKING ABOUT POWER IN A DIFFERENT WAY APPENDIX A3: MANAGING INCOMING POWER
“For years sensitive electronics have been segregated from other equipment in the recording and post production environment. When engineering a new system all loads should be divided into categories and isolated from one another.”
-Arthur Kelm, Ground One Work Includes: Chief Engineer at Skywalker Sound, Technical Consultant to Walt Disney Imagineering, General
Manager & Technician at Record One Studios
Motor loads are frequently associated with the negative effects of voltage spikes & dips when motors start up (example: HVAC systems).
Motor Loads
These loads are generally not a problem with the exception of florescent light ballasts and SCR dimmer circuits.
Lighting &
Convenience Loads
These are the most critical loads that must isolated, protected and conditioned! Audio Video systems are a perfect example.
Sensitive
Electronic Loads
Types of Loads