august 2020 | version 0820 | sika (nz) ltd

32

Upload: others

Post on 28-Jun-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD
Page 2: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

2

4 Pile Head Detail - Without levelling

5 Pile Head Detail - With levelling and SikaProof® Tape A+

6 Pile Head Detail for tension piles - With levelling and SikaProof® Tape A+

7 Construction Joint - For concrete stage wall with SikaProof® Sandwich Tape

8 Construction Joint - With external Sika® Waterbar

9 Construction Joint - With internal Sika® Waterbar

10 Construction Joint - With SikaFuko® Injection Hose

11 Construction Joint - With SikaSwell® A / S-2

12 Construction Joint - For concrete stage wall with SikaProof® Tape A+

13 Expansion Joint - With Sika® Waterbar

14 General membrane layout - Blindside waterproofing onto vertical excavation wall

15 General membrane layout - Blindside waterproofing with thermal insulation

CONTENTS

Page 3: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

3

16 General membrane layout - With protection layer or geotextile

17 General membrane layout - With thermal insulation

18 General overlap joint - With SikaProof® Tape A+

19 General overlap joint - With SikaProof® Sandwich Tape

20 Transition wall to roof slab - With SikaProof® P-1201 in-situ adheres post-applied system

21 Transition base slab to wall - With SikaProof® P-1201 in-situ adheres post-applied system

22 Transition base slab to wall with toe - With SikaProof® P-1201 in-situ adheres post-applied system

23 Transition base slab to wall - With SikaProof® Sandwich Tape

24 Transition base slab to wall - With SikaProof® Tape A+

25 Transition base slab to wall - Shotcrete Blinding with SikaProof® Tape A+

26 Pipe Penetration detail

27 Tie bolt detail in wall - With SikaProof® Patch-200 B

28 Sika® diaphragm wall (D-Wall) waterproofing solution - D-Wall double SikaFuko® with SikaProof® A+

29 Sika® diaphragm wall (D-Wall) waterproofing solution - D-Wall Waterbar with SikaProof® A+

31 Sika® diaphragm wall (D-Wall) waterproofing solution - D-Wall Waterbar/SikaFuko® with SikaProof® A+

Page 4: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

4

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0405C_2009_enSeptember 2020

SikaProof® A+ - PILE HEAD DETAILWithout levelling

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

900_020704_0405C_2009_enAs close to rebars

> 50 mm

Ground

Structural concrete

Substrate

Concrete pile head

SikaProof® A+ membrane

Additional SikaSwell® S-2,rings or SikaFuko®(depending on requirements)

Seal the top with appropriateSikadur® epoxy sealant

Optional SikaProof® Fix Tape-50 tofix the membrane onto the substrate

Page 5: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

5

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0406C_2009_enSeptember 2020SikaProof® A+ - PILE HEAD DETAIL

With levelling and SikaProof® Tape A+

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

900_020704_0406C_2009_en≥

50 m

m

SikaProof® A+ membrane

Levelling with SikaGrout®or waterproofed concrete

Adhere a strip of SikaProof® Tape A+around the pile head

SikaProof® Fix Tape-50 / Sandwich Tapeto fix the membrane onto the substrate

Seal the top with appropriateSikadur® epoxy sealant

Ground

Structural concrete

Substrate

Concrete pile head

As close to pile

≥ 30 mm

Additional SikaSwell® S-2,rings or SikaFuko®

Page 6: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

6

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0476C_2009_enSeptember 2020SikaProof® A+ - PILE HEAD DETAIL FOR TENSION PILES

With levelling and SikaProof® Tape A+

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

900_020704_0476C_2009_en≥

50 m

m

SikaProof® A+ membrane

Levelling with SikaGrout®or waterproofed concrete

Adhere a strip of SikaProof® Tape A+around the pile head

SikaProof® Fix Tape-50 / Sandwich Tapeto fix the membrane onto the substrate

Additional SikaFuko®

Ground

Structural concrete

Seal the top with appropriateSikadur® epoxy sealant

Substrate

Concrete pile head

As close to pile

≥ 30 mm

Page 7: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

7

900_020704_0407C_2009_enSeptember 2020

SikaProof® A+ - CONSTRUCTION JOINTFor concrete stage wall with SikaProof® Sandwich Tape

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

≥ 200 mm

900_020704_0407C_2009_en

First concrete stageSecond concrete stage

Top view

Reinforcement

Protection layer

SikaProof® A+ membrane

Structural concrete wallAdditional joint sealing(minimum SikaSwell® A)

Ground

SikaProof® Sandwich Tape

Page 8: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

8

900_020704_0408C_2009_enSeptember 2020

SikaProof® A+ - CONSTRUCTION JOINTWith external Sika Waterbar®

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0408C_2009_en

Second concrete stage First concrete stageReinforcement

Ground

Substrate even, smooth blinding concrete

External Sika Waterbar® fixed on each edgewith SikaProof® Sandwich Tape (optional each 5 min length bond a SikaProof® Sandwich Tape across)

Structural concrete

SikaProof® A+ membrane

Page 9: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

9

900_020704_0409C_2009_enSeptember 2020

SikaProof® A+ - CONSTRUCTION JOINTWith internal Sika Waterbar®

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0409C_1903_en

Second concrete stage First concrete stage

Ground

Substrate even, smooth blinding concrete

Internal Sika Waterbar®

Structural concrete

SikaProof® A+ membrane

Reinforcement

Page 10: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

10

900_020704_0410C_2009_enSeptember 2020

SikaProof® A+ - CONSTRUCTION JOINTWith SikaFuko® injection hose

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0410C_2009_en

Second concrete stage First concrete stage

Ground

Substrate even, smooth blinding concrete

Structural concrete

SikaProof® A+ membrane

SikaFuko® VT-1 / -2 reinjectable hose

Reinforcement

Page 11: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

11

900_020704_0411C_2009_enSeptember 2020

SikaProof® A+ - CONSTRUCTION JOINTWith SikaSwell® A / S-2

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO BOX 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0411C_2009_en

Structural concrete

First concrete stageSecond concrete stage

SikaProof® A+ membrane Ground

Substrate even, smooth blinding concreteSikaSwell® A profile adheredwith SikaSwell® S-2

Reinforcement

Page 12: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

12

900_020704_0427C_2009_enSeptember 2020

SikaProof® A+ - CONSTRUCTION JOINTFor concrete stage wall with SikaProof® Tape A+

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

≥ 200 mm

900_020704_0427C_2009_en

First concrete stageSecond concrete stage

Top view

Reinforcement

Protection layer

SikaProof® A+ membrane Substrate even, smooth blinding concrete

Structural concrete wallAdditional joint sealing(minimum SikaSwell® A)

Ground

SikaProof® Tape A+

Page 13: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

13

900_020704_0412C_2009_enSeptember 2020

SikaProof® A+ - EXPANSION JOINTWith Sika Waterbar®

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO BOX 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0412C_2009_en

Ground

Substrate even, smoothblinding concrete

Structural concretebase slab

Spacer plate

SikaProof® A+ membrane

External Sika Waterbar® fixed on eachedge with SikaProof® Sandwich Tape(optional each 5 m in length bond aSikaProof® Sandwich Tape across)

Page 14: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

14

900_020704_0413C_2009_enSeptember 2020

SikaProof® A+ - GENERAL MEMBRANE LAYOUTBlindside waterproofing onto vertical excavation wall

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0413C_2009_en

Vertical excavation wall

Levelling layer

Protection layer or geotextile minimum 300g/m² (depending on requirements)

SikaProof® A+ membrane

Structural concrete wall

Page 15: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

15

900_020704_0414C_2009_enSeptember 2020

SikaProof® A+ - GENERAL MEMBRANE LAYOUT ON WALLBlindside waterproofing with thermal insulation

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0414C_2009_en

Vertical excavation wall

Levelling layer

SikaProof® A+ membrane

Structural concrete wall

Thermal insulation

Page 16: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

16

900_020704_0417C_2009_enSeptember 2020

SikaProof® A+ - GENERAL MEMBRANE LAYOUT With protection layer or geotextile

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0417C_2009_en

Backfilling material

Protection layer or geotextile minimum 300 g/m2

(depending on backfilling material)

SikaProof® A+ membrane

Structural concrete wall

Page 17: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

17

900_020704_0418C_2009_enSeptember 2020

SikaProof® A+ - GENERAL MEMBRANE LAYOUTWith thermal insulation

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0418C_2009_en

Backfilling material

Thermal insulation

SikaProof® A+ membrane

Structural concrete wall

Page 18: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

18

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0415C_2009_enSeptember 2020

SikaProof® A+ - GENERAL OVERLAP JOINTWith SikaProof® Tape A+

900_020704_0415C_2009_en

50 mm

Ground

Substrate even, smooth blinding concrete

SikaProof® Tape A+

Structural concrete

SikaProof® A+ membrane

Page 19: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

19

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0416C_2009_enSeptember 2020

SikaProof® A+ - GENERAL OVERLAP JOINTWith SikaProof® Sandwich Tape

900_020704_0416C_2009_en

> 50 mm

Ground

Substrate even, smooth blinding concrete

SikaProof® Sandwich Tape

Structural concrete

SikaProof® A+ membrane

Page 20: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

20

900_020704_0419C_2009_en August 2021 NZ

SikaProof® A+ - TRANSITION WALL TO ROOF SLABWith SikaProof® P-12 in-situ adhered post-applied system

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

900_020704_0419C_2009_en

>10

0 m

m>

200

mm

Structural concrete wall

Overlapping surface of SikaProof® A+

SikaProof® A+ membrane

SikaProof® P-12 membrane

SikaProof® Primer-01

Structural concrete roof slab

Additional joint sealing(minimum SikaSwell® A)

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

Page 21: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

21

900_020704_0421C_2009_en August 2021 NZ

SikaProof® A+ - TRANSITION BASE SLAB TO WALLWith SikaProof® P-12 in-situ adhered post-applied system

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0421C_2009_en

Structural concrete base slab

Ground

Additional joint sealing (minimum SikaSwell® A)

Substrate even,smooth blinding concrete

SikaProof® A+ membrane

Structural concrete wall

>10

0 m

m>

50 m

m

Backfilling material

Protection layer

SikaProof® P-12 membrane

SikaProof® Primer-01

Overlapping surface of SikaProof® A+ membrane

Page 22: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

22

900_020704_0422C_2009_en August 2021 NZ

SikaProof® A+ - TRANSITION BASE SLAB TO WALL WITH TOE With SikaProof® P-12 in-situ adhered post-applied system

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0422C_2009_en

>10

0 m

m

Structural concrete base slab

Ground

Substrate even,smooth blinding concrete

SikaProof® A+ membrane

Additional joint sealing (minimum SikaSwell® A)

Structural concrete wallBackfilling material

Protection layer

SikaProof® P-12 membrane

SikaProof® Primer-01

Chamfer concrete edge

>50

mm

Overlapping surface of SikaProof® A+

Page 23: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

23

900_020704_0423C_2009_enSeptember 2020

SikaProof® A+ - TRANSITION BASE SLAB TO WALLWith SikaProof® Sandwich Tape

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0423C_2009_en

≥ 2

00 m

m

Structural concrete base slab

Ground

Additional joint sealing (minimum SikaSwell® A)

Substrate even,smooth blinding concrete

SikaProof® A+ membrane

Reinforcement starter bars

Structural concrete wall

Excavation wall orbackfilling material

SikaProof® A+ membrane

Protection layer

SikaProof® Sandwich Tape

Page 24: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

24

900_020704_0428C_2009_enSeptember 2020

SikaProof® A+ - TRANSITION BASE SLAB TO WALLWith SikaProof® Tape A+

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0428C_2009_en

≥ 2

00 m

mStructural concrete base slab

Ground

Additional joint sealing (minimum SikaSwell® A)

Substrate even,smooth blinding concrete

SikaProof® A+ membrane

Reinforcement starter bars

Structural concrete wall

Excavation wall orbackfilling material

SikaProof® A+ membrane

Protection layer

SikaProof® Tape A+

Page 25: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

25

900_020704_0652C_2009_enSeptember 2020

SikaProof® A+ - TRANSITION BASE SLAB TO WALL Shotcrete Blinding with SikaProof® Tape A+

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0652C_2009_en

≥ 2

00 m

m

Structural concrete base slab

Ground

Additional joint sealing (minimum SikaSwell® A)

Substrate even,smooth blinding concrete

SikaProof® A+ membrane

Reinforcement starter bars

Structural concrete wall

SikaProof® Tape A+

Bored concrete pile

Shotcrete layer

Protection layer (e.g. Sika® Geotextile 500g/m2)

SikaProof® A+ membrane

Page 26: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

26

900_020704_0420C_2009_enSeptember 2020

SikaProof® A+ - PIPE PENETRATION DETAIL

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0420C_2009_en

Ground

Substrate even, smooth blinding concrete

SikaProof® A+ membrane

Structural concrete

SikaProof® Tape A+

Pipe penetration

SikaSwell® S-2(depending on requirements)

Page 27: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

27

900_020704_0424C_2009_enSeptember 2020

SikaProof® A+ - TIE BOLT DETAIL IN WALLWith SikaProof® Patch-200 B

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information onlyapplies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika'sTechnical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer tothe most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020704_0424C_2009_en

Top view

Protection layer

Backfilling material

Structural concrete wall

SikaProof® A+ membrane

SikaProof® Patch-200 B(use a strip of SikaProof®Fix Tape-50 to level thetie bolt holt)

Fill the tie bolt hole with a suitableSikaGrout® / Sikadur® groutingmaterial, minimum 100 mm

Page 28: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

28

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020707_0446C_1904_enApril 2019

SIKA DIAPHRAGM WALL (D-WALL)WATERPROOFING SOLUTIOND-Wall double SikaFuko® with SikaProof® A+

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

900_020707_0446C_1904_en

SikaProof® A+ 12 membrane

D-Wall

Injection of the D-Wall joints withSika® Injection-310 through SikaFuko® VT-2

Sika® Injection-310in D-Wall panel joints

SikaFuko® VT-1 pre-injectedwith Sika® Injection-307

SikaFuko® VT-1 pre-injectedwith Sika® Injection-307

SikaSwell® A Profile adhered with SikaSwell® S-2

SikaProof® A+ 12 membrane adhered with Sikadur®-31 CF

Geotextile cushion layer

Blinding concrete

SikaProof® Tape A+

Page 29: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

29

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020707_0450C_1904_enApril 2019

SIKA DIAPHRAGM WALL (D-WALL)WATERPROOFING SOLUTIOND-Wall Waterbar with SikaProof® A+

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

900_020707_0450C_1904_en

D-Wall

SikaProof® A+ 12 membrane

Sika Waterbar® O-20 DWall orSika Waterbar® O-25 DWall

Sika® Injection-310in D-Wall panel joints

SikaFuko® VT-1 pre-injectedwith Sika® Injection-307

SikaFuko® VT-1 pre-injectedwith Sika® Injection-307

SikaSwell® A Profile adhered with SikaSwell® S-2

SikaProof® A+ 12 membrane adhered with Sikadur®-31 CF

Geotextile cushion layer

Blinding concrete

SikaProof® Tape A+

Page 30: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

30

Sika (NZ) LTD

PO Box 19192

Auckland 1746

New Zealand

Ph. 0800 745 269

www.sika.co.nz

900_020707_0442C_1904_enApril 2019

SIKA DIAPHRAGM WALL (D-WALL)WATERPROOFING SOLUTIOND-Wall Waterbar/SikaFuko® with SikaProof® A+

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

900_020707_0442C_1904_en

D-Wall

SikaProof® A+ 12 membrane

Sika Waterbar® O-20 DWall orSika Waterbar® O-25 DWall

Injection of the D-Wall joints withSika® Injection-310 through SikaFuko® VT-2

Sika® Injection-310in D-Wall panel joints

SikaFuko® VT-1 pre-injectedwith Sika® Injection-307

SikaFuko® VT-1 pre-injectedwith Sika® Injection-307

SikaSwell® A Profile adhered with SikaSwell® S-2

SikaProof® A+ 12 membrane adhered with Sikadur®-31 CF

Geotextile cushion layer

Blinding concrete

SikaProof® Tape A+

Page 31: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD
Page 32: AUGUST 2020 | VERSION 0820 | SIKA (NZ) LTD

32

SIKA (NZ) LTDPO BOX 19192Avondale · Auckland1746 · New Zealand

ContactPhone 0800 745 269www.sika.co.nz

WHO WE ARESika AG, Switzerland, is a globally active speciality chemicals company. Sika supplies the building and construction industry as well as manufacturing industries (automotive, bus, truck, rail, solar and wind power plants, façades). Sika is a leader in processing materials used in sealing, bonding, damping, reinforcing and protecting loadbearing structures. Sika’s product lines feature high quality concrete admixtures, specialty mortars, sealants and adhesives, damping and reinforcing materials, structural strengthening systems, industrial flooring as well as roofing and waterproofing systems.

FOR MORE WATERPROOFING INFORMATION:

/122