autoliv safety center · 2019-09-30 · autolivsafety center component test laboratory for more...

1
Autoliv Safety Center Component Test Laboratory For more information, do not hesitate to contact us! Thomas Norberg Phone: +46 322 62 6234 Email: [email protected] www. testcenter.autoliv.com Environmental Climate Temperatures -70 oC - +180 o C Relative humidity <98 % Climate chambers 1m 3 - 18m 3 Test object <3,5m x 2m x 2m Aging Temperatures -70 o - +300 o C Chambers 1m 3 - 17 m 3 Test object <4m x 1,8m x 1,8m Temperature chock Transition times >10 s Temperatures -80 o C - +200 o C Test object <3,5m x 1m x 1,5m Corrosion Salt fog in programmable chamber Test object <1,5m x 1m x 1m Dust Test object <1,5m x 1m x 1m Different types of dust Dew test Test object <0,5m x 0,5m x 0,5m Strength Tensile strength - Static forces <100kN Pendulum - Dynamic forces <20kN Vibration 6-degrees of freedom vibrator Field data reshaped in laboratory Masses < 350 kg 3-axis vibrator Masses <900 kg Temperatures -40 o C to +105 o C Acoustic Noise chamber - Field data in laboratory Impulse noise - Ear model for injury values Testing ground Special surface of cobble stone Squeak and rattle test Miscellaneous Odour test - Subjective evaluation Scratch test - 0-10N, 0-20N Abrasion test - Textiles and plastic Nickel leakage test - Cr6+ test Flammability test - Textiles and plastics Compression test - Spring force test High speed filming - <20 000 fps Drop test - Into steel plate Endurance test - Wear out test Gloss tolerances - Spectrophotometer test Judgement of appearance - Colour and surface Colour tolerance test - Plastic materials Chemical resistance test Digital microscope Deployment Dynamic Masses <100kg Velocity <16m/s FMHI Free Motion Head Impact Static - Temperatures -40°C - +100 °C OOP - Multiple dummies IP First numeral; 1-6 Second numeral; 1-5, 7-9 CE Testing according to EN/ISO 14451 Drop, Vibration, Thermal, Fire, Tank, Functioning Ulrika Carlsson Phone: +46 322 66 7748 Email: [email protected]

Upload: others

Post on 07-Apr-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Autoliv Safety Center · 2019-09-30 · AutolivSafety Center Component Test Laboratory For more information, do not hesitate to contact us! Thomas Norberg Phone: +46 322 62 6234 E

Autoliv Safety CenterComponent Test Laboratory

For more information, do not hesitate to contact us!

Thomas NorbergPhone: +46 322 62 6234

E‐mail: [email protected]

www. testcenter.autoliv.com

Environmental• Climate

Temperatures -70oC - +180o C Relative humidity <98 % Climate chambers 1m3 - 18m3

Test object <3,5m x 2m x 2m• Aging

Temperatures -70o - +300o C Chambers 1m3 - 17 m3

Test object <4m x 1,8m x 1,8m• Temperature chock

Transition times >10 s Temperatures -80oC - +200o C Test object <3,5m x 1m x 1,5m

• Corrosion Salt fog in programmable chamber Test object <1,5m x 1m x 1m

• Dust Test object <1,5m x 1m x 1m Different types of dust

• Dew test Test object <0,5m x 0,5m x 0,5m

Strength• Tensile strength - Static forces <100kN• Pendulum - Dynamic forces <20kN

Vibration• 6-degrees of freedom vibrator

Field data reshaped in laboratory Masses < 350 kg

• 3-axis vibrator Masses <900 kg Temperatures -40oC to +105oC

Acoustic• Noise chamber - Field data in laboratory • Impulse noise - Ear model for injury values• Testing ground

Special surface of cobble stone Squeak and rattle test

Miscellaneous• Odour test - Subjective evaluation • Scratch test - 0-10N, 0-20N • Abrasion test - Textiles and plastic• Nickel leakage test - Cr6+ test• Flammability test - Textiles and plastics• Compression test - Spring force test• High speed filming - <20 000 fps• Drop test - Into steel plate• Endurance test - Wear out test• Gloss tolerances - Spectrophotometer test• Judgement of appearance - Colour and surface• Colour tolerance test - Plastic materials• Chemical resistance test• Digital microscope

Deployment • Dynamic

Masses <100kg Velocity <16m/s FMHI Free Motion Head Impact

• Static - Temperatures -40°C - +100 °C• OOP - Multiple dummies

IP• First numeral; 1-6• Second numeral; 1-5, 7-9

CE• Testing according to EN/ISO 14451• Drop, Vibration, Thermal, Fire, Tank, Functioning

Ulrika Carlsson  Phone: +46 322 66 7748

E‐mail: [email protected]