ELECTRICAL INSTALLATION MANUAL**SLIDERS**
1510596 Revision 5-18-04
NABCO ENTRANCES INC.Phone: 877-622-2694 Fax: 888-679-3319Technical Assistance: 1-866-622-8325http://www.nabcoentrances.comEmail: [email protected]
WARNINGDo not install, operate or service this product unless you have read and understand the
Safety Practices, Warnings, Installation and Operating Instructions contained in this man-ual. Failure to do so may result in property damage, or bodily injury.
BLUEBLUE
RED
YELLOW
GREEN
REDBROWN
PLUG WITH BLUE JUMPER MUST BE
IN PLACE
NOT USED
RED
YELLOWREDBROWN
RED
GREEN
ORANGEBROWN
PLUG WITH BLUEJUMPER MUSTBE IN PLACE
ACUSENSORHARNESS
PT. NO. 229184
BROWN
WIRE NUT
BLUE
BLACK
BLACK
BLACK"REDUCE"
LEAVE OPEN
EMITTERDETECTOR
BROWN
LIGHT BLUEBROWN
BROWN
INTERIOR ACUSENSORPT. NO. 148902
BLACK
BLUE
EXTERIOR ACUSENSORPT. NO. 148902
ACUSENSOR HARNESS
PT. NO. 229184
Teleco Brand Safety Beams
BLUEWHITERED
GREENBLACK
BLUE
REDWHITE
GREENBLACK
BLACK 120 VAC "HOT"120 VAC "COMMON"SERVICE GROUND
BLACK
BLACK
WHITE
WHITE
BLUE
BLACKBROWNREDGREENORANGEORANGE
SWITCH BOX
WIRE NUT
WIRE NUT
CAUTION For continued protectionagainst fire, replace onlywith a fuse of the sametype and rating.WARNING
Not Used115 VAC Common115 VAC HotNot UsedWhiteBlack1234NO.COLORUSEMotor V PhaseEncoder 12 VDCEncoder A PhaseMotor U PhaseEncoder GroundEncoder B PhaseUSERedOrangeBrownBlueBlackYellow123456NO.COLOR12 VDC+12 VDC - (Common)Interior Activation SensorHolding BeamReduced OpeningMode Switch 1Mode Switch 2Exterior Activation Sensor Alternating ActivationBreakoutOutput Switch HI (Elec. Lock, Airlock, etc.)Output Switch LO (Elec. Lock, Airlock, etc.)
BrownRedBlackWhiteGreenOrangeOrangeOrangeYellowBlueVioletGray9DC12V7616 BHM0M162SQBAOUT +OUT -123456789101112 (See Mode Switch Table)NO.SYMBOLCOLORUSE [ SLIDE MODE SELECTED ]USE [ SWING MODE SELECTED ](See Mode Switch Table)MODE SWITCH TABLEMOOpenGndGndOpenM1OpenOpenGndGndModeAutoExitHold OpenNight
No.Fuse Inside
Rating: 125V, 5ASize: 5.2 x 20mm1. Adjustments to the door can only be made with a Handy Terminal.
No adjustments are available inside the control box.2. Replaceable fuse located inside the control box.3. Turn the power off prior to removing the cover.4. This unit can not be repaired in the field. Any attempted repairs
by an unauthorized NABCO facility will void the warranty.
N A B C O 2 4 8 9 0 1 M i c r o p r o c e s s o r C o n t r o l l e r 12 VDC+12 VDC - (Common)Approach Activation SensorHolding Beam or Swing SensorThreshold Safety MatMode Switch 1Mode Switch 2Exterior Activation SensorAlternating ActivationBreakoutOutput Switch HI (Elec. Lock, Airlock, etc.)Output Switch LO (Elec. Lock, Airlock, etc.)Power Connector (4 pin)
Motor Connector (6 pin)
Handy Terminal Connector (6 pin)Main Harness Connector (12 pin)
VIOLETGRAYYELLOW NOT USED
ORANGE
NOT USEDNOT USED
WIRE NUT
WIRE NUTWHITE
MOTOR
OPERATOR
MINIMUM 5 AMPERE SERVICEPER OPERATOR
GREEN
BLACKBLUE
BLUE
ON
O N E W A Y
R E D U C E D O P E N
H O L D O P E NF U L L O P E N
ON
LY
AU
TO
DO
OR
OP
ER
AT
ION
RED
BLACKRED
RED
OF
F
N I G H T
BLUE
BACK SIDE OFSWITCH SHOWN.
BLACK
WHITE
WHITE
REDROCKER SWITCH EXTENSION HARNESSPT. 229186
MOTOR HARNESS AND PLUGS
PLUG FOR HANDY TERMINAL
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 2 -
Table of Contents
Electrical Information Page 3
Typical Slider Wiring Page 4
Microprocessor Controller Page 5-6
Dual Operator Wiring Diagrams Page 7
Acusensor/Acumotion Page 8
How Door Function Modes are Achieved via the Rocker Switches Page 9
Holding Beams (Activation—Hold Open) Page 10
Holding Beam (Breakout—Power Interrupt) Page 11
Diagram for connecting push plates and or card readers for Night mode. Page 12
Electric Locks—Fail Safe Page 13
Electric Locks—Fail Secure Page 14
Troubleshooting Page 15-17
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 3 -
Electrical Information
Note: Since the Model 1175 Slider is predominantly wired at the factory the site installer/electrician has a relatively simple task.
1. Convenient electric service access holes have been provided in the slide header end caps and jamb tubes. An installer/electrician should route 120 VAC, single phase, 5 AMP (MINIMUM) power to the factory sup-plied and mounted junction box in the header.
2. The installer/electrician should connect one power hot lead (Black) to the power cut off switch mounted inside the junction box. Utilizing an ap-propriate wire nut, the installer/electrician should connect the common lead (White) to the loose common lead (White) found inside the junction box. The ground wire should be connected to the ground screw located in the back of the switch junction box.
3. Replace the junction box cover. The unit’s power should now be activated through the building’s electrical circuit breaker box. Proceed with performance set-up procedures outlined in the Mi-croprocessor and Handy Terminal Manual p/n 159000
WARNINGDisconnect all power to the junction box prior to making any electrical connections. Wiring must meet all local, state, federal or other governing agency codes. Failure to do so may result in serious personal or fatal injury.
Factory Wiring
GroundHot
Common
DN 0006
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 4 -
Typical Slider Wiring
Wiring diagrams are included in the back of this manual, which reflect the typical primary and secondary circuits installed at the factory. The low voltage (12 VDC) Reed switch (panic break away) and Acusensor are easily connected on site using factory installed connector housings. The factory uses Underwriters Laboratories’ (UL) recognized component wire, terminals and connector housings to manufacture the slider. Contact the Customer Service Department for assistance with special applications.
WARNINGMicroprocessor controller contains HIGH VOLTAGE! Installation should be performed by qualified personnel only. Wiring must meet all local, state, federal or other governing agency
codes. Failure to do so may result in serious personal or fatal injury.
General Wiring Diagram
BACK SIDE OFSWITCH SHOWN.
SW. EXT.HARNESS
PT. NO. 22-9220
SW. EXT.HARNESS
PT. NO. 22-9220
WHITEWHITE
PLUG WITH BLUE JUMPER
MUST BE IN PLACE
PN 120324
HOLDING BEAM CONNECTOR. USE
ONLY WITHHOLDING BEAMS!
ACUSENSOR EXTENSION HARNESS
PT. NO.22-9267RED
Yel
Gray Gray
Yel
RED
ACUSENSOR EXTENSION HARNESS
PT. NO.22-9267
RED
ACUSENSOR HARNESSPT. NO. 229184
BLACK
GREENWHITE
EXTERIOR ACUSENSORPT. NO. 148902
MAGNETIC POWER DOWN SWITCH PT.
NO. 229222
MAGNETIC POWER DOWN SWITCH PT.
NO. 229222
HANDING HARNESSPT. NO. 11-9208
RIGHT HAND UNITS ONLY
MTR. HARNESS
& PLUG
Microprocessor ControllerPT. NO. 24-8901
PN 219821-01
2110097 Telescopic Operator219528 1175 Slider Operator
Telescopic units only.Second pulley for
PLUG FOR HANDY TERMINAL
U16 and later models.New Switch
BROWNORANGE
RED
GREEN
BROWN +12 VDC
PT. 229186EXTENSION HARNESSROCKER SWITCH
BLACKGREEN
REDWHITEBLUE
WHITE
PT. NO. 148902INTERIOR ACUSENSOR
WHITEGREEN
BLACK
PT. NO. 229184ACUSENSOR HARNESS
GREEN
RED
WHITE
BLUE
REDREDBLUEBLUE
Red
White
White
Black
Red
Blue
Red
Green
Red
OPEN
FULL
HOLD OPEN
ONE WAY
TWO
WAY
NIGHT
OFF
REDUCED OPEN
ON
Green
Black
White
Black
Blue
Red
BLACKGREEN
WHITERED
BLUE
WIRE NUT
WIRE NUT
PER OPERATORMINIMUM 5 AMPERE SERVICE
USED FOR ELECTRIC LOCKUSED FOR ELECTRIC LOCKUSED FOR SEQUENTIAL OPERATION
WHITE
OPERATOR
MOTOR
ORANGE 62
YELLOWGRAYVIOLET
Handy Terminal Connector (6 pin)
M o t o r C o n n e c t o r (6 p i n )
P o w e r C o n n e c t o r ( 4 p i n )
S i z e : 5 .2 x 2 0 m mR a t i n g : 1 2 5 V , 5A
F u s e Ins ide
N o .
C O L O RS Y M B O LN O .
12
11
10
9
8
7
6
5
4
3
2
1
O U T -
O U T +
BA
SQ
62
M1
M0
H
6 B
61
7
9 D C 1 2 V
G r a y
V i o l e t
B l u e
Y e l l o w
O r a n g e
O r a n g e
O r a n g e
G r e e n
W h i t e
B l a c k
R e d
B r o w n
C O L O RN O .
6
5
4
3
2
1
Y e l l o w
B l a c k
B l u e
B r o w n
O r a n g e
R e dU S E
E n c o d e r B P h a s e
E n c o d e r G r o u n d
M o t o r U P h a s e
E n c o d e r A P h a s e
E n c o d e r 1 2 V D C
M o t o r V P h a s e
U S EC O L O RN O .
4
3
2
1
B l a c k
W h i t e
N o t U s e d
1 1 5 V A C H o t
1 1 5 V A C C o m m o n
N o t U s e d
W A R N I N G
t y p e a n d r a t i n g .
w i th a f u s e o f t h e s a m e
a g a i n s t f i re , r e p l a c e o n l yF o r c o n t i n u e d p r o t e c t i o n
C A U T I O N
WIRE NUT
WIRE NUT
SWITCH BOX
ORANGE M1ORANGE M0GREENREDBROWNBLACK
BLUE
WHITE
GREEN
WHITE
BLACK
BLACK
SERVICE GROUND
120 VAC "COMMON"
120 VAC "HOT"BLACK
DN 0001
WHITE
WHITE
OFF
NIGHT
RED
RED
BLUE
BLACK
RED
RED
BLACK
DOO
R O
PERATIO
NAU
TOO
NLY
FULL OPENHOLD OPEN
REDUCED OPEN
BLACKGREEN
WHITERED
ONE WAY
ON
BLUE
SWITCH SHOWN.BACK SIDE OF
U16 and earlier models.Old Switch
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 5 -
By
alte
rnat
ely
switc
hing
the
two
MO
& M
1 (o
rang
e w
ires)
on
the
mic
ropr
oces
sor h
arne
ss to
RED
(com
mon
) the
var
ious
doo
r mod
es su
ch a
s H
OLD
OPE
N m
ode,
EX
IT m
ode,
NIG
HT
mod
e et
c. a
re a
chie
ved.
(Off
= no
t sw
itche
d to
com
mon
On
= sw
itche
d to
com
mon
)Bl
ue (B
A) w
ire m
ust r
emai
n tie
d to
Red
(Com
mon
) for
doo
r to
func
tion.
Refe
r to
Page
9 fo
r mor
e in
form
atio
n
Inte
rnal
1
Amp
Rel
ay
DN
0010
All
volta
ges
show
n m
easu
red
with
resp
ect t
o R
ed (C
omm
on)
Aux
iliary
O
utpu
t(th
is s
witc
h ac
ts li
ke a
do
or
sequ
ence
r)
Sequ
entia
l W
all S
witc
hH
oldi
ng B
eam
sN
.O. c
onta
cts
Exte
rior S
enso
rN
.O. c
onta
cts
Inte
rior S
enso
rN
.O. c
onta
cts
12 V
DC
@ n
o Ac
tivat
ion
0 VD
C @
Act
ivat
ion
12 V
DC
@ n
o Ac
tivat
ion
0 VD
C @
Act
ivat
ion
12 V
DC
@ n
o Ac
tivat
ion
0 VD
C @
Act
ivat
ion
Red
(Com
mon
)
ON
/OFF
R
ocke
r Sw
itch
Pani
cBr
eako
ut /
Stop
C
ircui
t
Logi
c C
ircui
t
Logi
c C
ircui
t
Red
uced
O
peni
ng
Pan
ic B
reak
out S
witc
h (n
orm
ally
clo
sed
cont
acts
)
0 VD
C if
Pan
ic C
ircui
t Clo
sed
and
Roc
ker S
witc
h Tu
rned
"ON
"12
VD
C if
Pan
ic C
ircui
t Ope
n or
Roc
ker S
witc
h Tu
rned
"OFF
"
+12
VDC
Slid
er S
chem
atic
Wiri
ng D
iagr
am -
U04
and
Hig
her M
icro
proc
esso
r
Blu
e
Nab
co "
U"
Serie
s M
icro
proc
esso
r
Roc
ker S
witc
h Ba
nk
Ora
nge
(M0)
Ora
nge
(M1)
Red
(7)
Viol
et (o
ut+)
Yello
w(S
Q)
Gra
y(ou
t-)
Gre
en (H
)
Blue
(BA
)
Blac
k (6
1)
Brow
n (9
DC
12V
)
Whi
te (6
B)
Ora
nge
(62)
Pan
ic B
reak
out S
witc
h (n
orm
ally
clo
sed
cont
acts
)
Pan
ic B
reak
out S
witc
h (n
orm
ally
clo
sed
cont
acts
)
PN 2
4980
1
Microprocessor Controller
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 6 -
Microprocessor Controller
The Microprocessor controller has been designed to control the numerous operating characteristics of the slide door system including speed, recycling and door opening width. It will need to be programmed after the installation is complete. (See the Microprocessor Manual p/n 159000 for more details).
CAUTION:Read and understand the Microprocessor Manual p/n 159000 before attempting to
power-up the door. Failure to do so may result in damage to the door and/or injury to the installer and will nullify all warranties.
Microprocessor Main Harness Diagram
Bla
ck
Yell
owB
lue
Pur
ple
Gre
y
Ora
nge
M1
Bro
wn
Red B
lack
Ora
nge
MO
Gre
enW
hite
Whit
eBl
ack
Blu
eG
reen
Ora
nge
MO
Ora
nge
M1
Red
Bro
wn
CN
4
Red
Red
Gre
en
Bro
wn Re
d
Roc
ker
Sw
itch
Con
nect
or
Blue
Blue
Blac
kG
reen
Blue
Whi
teRe
d
Mot
or P
lugCN
2
M.C
.
CN
1
Red
Gre
enR
ed
Blue
Red
ON
RE
DU
CE
D O
PE
N
OFF
NIGH
T
TWO WAY
ON
E W
AY
HOLD
OPE
N
Red
Blac
k
Whi
te
Whi
teBl
ack
FULLOPEN
Red Blue Gre
en
Blac
k
Whi
te
Hol
ding
Bea
m C
onne
ctor
Red
Blue
Bre
akaw
ayC
onne
ctor
s
BlueR
ed
Blu
e
Inte
rior A
ccus
enso
rC
onne
ctor
Whit
e
Whit
e
Whit
e
Whit
e
Whit
e
Whit
e
Whi
te
Blac
k
Gro
und
Whit
e
120
VA
C
HO
LD O
PE
N
FULL
Bla
ck
Bla
ck
Red
Gre
enR
ed
Whit
e
Blue
Red
Red
AUTO
NIG
HT
ON
Blue
D O O R O P E R A T I O NO N L Y
O F F
RE
DU
CE
D O
PE
N
Whi
te
ON
E W
AY
Mai
n B
reak
erS
witc
hin
Hea
der
DN
000
2
CN
3
Han
dyT
erm
inal
Con
nect
or
Red
Bro
wn O
rang
e
Ora
nge
Yello
wG
reen
Blue
Whi
teR
edYe
llow
Blac
k
Blu
e
Ora
nge
62
Roc
ker S
witc
h E
xten
sion
Har
ness
PN
229
186
Roc
ker S
witc
hes
(Old
)U
16 a
nd e
arlie
r mod
els.
Bac
ksid
e of
bot
hsw
itche
s sh
own.
Roc
ker S
witc
hes
(New
)U
16 a
nd la
ter m
odel
s.P
N 2
1982
1-01
NO
TE
: In
som
e ca
ses
the
inte
rior
and
exte
rior A
ccus
enso
rs a
re re
vers
ed
Ext
erio
r A
ccus
enso
rC
onne
ctor
Blu
eR
ed
Whit
e
Gre
en
Bla
ck
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 7 -
NOT
USED
NOT
USED
HARN
ESS
FO
R SL
IDE
RSI
MUL
TAN
EO
US P
AIR
P/N:
215
901
ROC
KER
SW
ITC
HES
P/N:
219
821-
01
CAUT
ION
USE
[SLI
DER/
SWIN
GER
]
For
cont
inued
pro
tect
ionag
ainst
fire
, re
place
only
with
sam
e ty
pe a
nd r
ating
of f
use.
WAR
NING
1 2 3 4
COLO
R
WHI
TEBL
ACK
NO.
USE
EMPT
Y
115V
AC H
OT
EMPT
Y
1 2 3 4 5 6
ORA
NGE
RED
BRO
WN
YELL
OW
COLO
RNO
.US
E
115V
AC C
OM
MO
N
MO
TOR
V PH
ASE
ENCO
DER
A PH
ASE
MO
TOR
U PH
ASE
ENCO
DER
GND
ENCO
DER
B PH
ASE
1 2 3 4
7 61 6B
NO. 9D
C12V
COLO
RSY
MBO
L BRO
WN
RED
BLAC
KW
HITE
12VD
C +
12VD
C -,
COM
MO
NAP
PRO
ACH
5H
GRE
EN
6 7 8 9 10 11 12
M0
M1
62 BA OUT
+O
UT -
ORA
NGE
ORA
NGE
ORA
NGE
YELL
OW
BLUE
VIO
LET
GRA
Y
SQ
OUT
PUT
-O
UTPU
T +
SEQ
UENT
IAL
APPR
OAC
H(TH
ROUG
H)
REDU
CED
OPE
NING
/SAF
ETY
MAT
THRE
SHO
LD S
ENSI
NG /
PRES
ENCE
SEN
SOR
MO
DE S
W1
MO
DE S
W2
BREA
K O
UT
BLUE
BLAC
K
GYRO
TECH
- 248
901.10
POW
ER S
OUR
CE (
4P)
OPE
RATO
R (6
P)FU
SE
INSI
DERA
TING
:125
V, 4
ASI
ZE:5
.2 x
20m
m
HAND
Y TE
RMIN
AL (
6P)
SENS
OR
(12P
)
1.Ple
ase
adjus
t th
is op
erat
or a
s pe
r ins
truc
tion
man
ual.
2.Tu
rn t
he p
ower
off
, be
fore
ope
ning
the
box.
3.Do
n't o
pen
this
box
exce
pt f
or r
eplac
ing f
use.
O
ther
wise,
the
war
rant
y will
be t
erm
inate
d.4.
Repa
ir of
this
unit
exc
ept
by N
abco
Ent
ranc
es,
Inc.
m
ay c
ause
sof
twar
e an
d ha
rdwa
re m
alfun
ction
.
CAUT
ION
USE
[SLI
DER/
SWIN
GER
]
For
cont
inued
pro
tect
ionag
ainst
fire
, re
place
only
with
sam
e ty
pe a
nd r
ating
of f
use.
WAR
NING
1 2 3 4
COLO
R
WHI
TEBL
ACK
NO.
USE
EMPT
Y
115V
AC H
OT
EMPT
Y
1 2 3 4 5 6
ORA
NGE
RED
BRO
WN
YELL
OW
COLO
RNO
.US
E
115V
AC C
OM
MO
N
MO
TOR
V PH
ASE
ENCO
DER
12VD
CEN
CODE
R A
PHAS
EM
OTO
R U
PHAS
EEN
CODE
R G
NDEN
CODE
R B
PHAS
E
1 2 3 4
7 61 6B
NO. 9D
C12V
COLO
RSY
MBO
L BRO
WN
RED
BLAC
KW
HITE
12VD
C +
12VD
C -,
COM
MO
NAP
PRO
ACH
5H
GRE
EN
6 7 8 9 10 11 12
M0
M1
62 BA OUT
+O
UT -
ORA
NGE
ORA
NGE
ORA
NGE
YELL
OW
BLUE
VIO
LET
GRA
Y
SQ
OUT
PUT
-O
UTPU
T +
SEQ
UENT
IAL
APPR
OAC
H(TH
ROUG
H)
REDU
CED
OPE
NING
/SAF
ETY
MAT
THRE
SHO
LD S
ENSI
NG /
PRES
ENCE
SEN
SOR
MO
DE S
W1
MO
DE S
W2
BREA
K O
UT
BLUE
BLAC
K
GYRO
TECH
- 248
901.10
POW
ER S
OUR
CE (
4P)
OPE
RATO
R (6
P)FU
SE
INSI
DERA
TING
:125
V, 4
ASI
ZE:5
.2 x
20m
m
HAND
Y TE
RMIN
AL (
6P)
SENS
OR
(12P
)
1.Ple
ase
adjus
t th
is op
erat
or a
s pe
r ins
truc
tion
man
ual.
2.Tu
rn t
he p
ower
off
, be
fore
ope
ning
the
box.
3.Do
n't o
pen
this
box
exce
pt f
or r
eplac
ing f
use.
O
ther
wise,
the
war
rant
y will
be t
erm
inate
d.4.
Repa
ir of
this
unit
exc
ept
by N
abco
Ent
ranc
es,
Inc.
m
ay c
ause
sof
twar
e an
d ha
rdwa
re m
alfun
ction
.
A B
Bla
ck(6
1)W
hite
(6B
)G
reen
(H)
Ora
nge(
M0)
Ora
nge(
M1)
Ora
nge(
62)
Blu
e(B
A)
Red
(7)
Vio
let(O
UT+
)
Bro
wn(
9DC
12V
)
Gra
y(O
UT-
)
Yel
low
(SQ
)
Bla
ck(6
1)W
hite
(6B
)G
reen
(H)
Ora
nge(
M0)
Ora
nge(
M1)
Ora
nge(
62)
Blu
e(B
A)
Red
(7)
Vio
let(O
UT+
)
Bro
wn(
9DC
12V
)
Gra
y(O
UT-
)
Yel
low
(SQ
)
RE
D
BR
OW
NB
RO
WN
RE
D
GR
EE
NO
RA
NG
E(6
2)
RE
DW
HIT
E
RE
D
RE
DW
HIT
E
RE
D
RE
DR
ED
BR
OW
NB
RO
WN
BLA
CK
RE
D
BR
OW
NB
RO
WN
RE
D
GR
EE
NO
RA
NG
E(6
2)
LAB
EL
B
LAB
EL
B
LAB
EL
A
C
124 3
2 12 1 124
124 3
21
21
D2
2
BLU
EB
LUE
BLU
EB
LUE
BLU
E
RE
DR
ED
1
1
2 41 3 5
2 41 3 5
21
21
21
21
GR
EE
NG
RE
EN
OR
AN
GE
(M1)
OR
AN
GE
(M0)
BLU
EB
LUE
Bre
akou
t Sw
itch
B s
ide
door
4/1/
2004
RE
DR
ED
BR
OW
NB
RO
WN
BLA
CK
BLU
EB
LUE
BLU
EB
LUE
LAB
EL
A
2 41 3 5
21
21
2 41 3 5
124
21
21
21
21
BLU
EB
LUE
GR
EE
NG
RE
EN
OR
AN
GE
(M1)
ON
REDU
CED
OPE
N
OFF
NIG
HT
T W O W A Y
ONE
WAY
HOLD
OPE
N
F U L LO P EN
DU
AL
OP
ER
ATO
R W
IRIN
G D
IAG
RA
M
DN
0071
Bre
akou
t Sw
itch
A s
ide
door
MIC
ROPR
OCE
SSO
R CO
NTR
OLL
ER
(MC
)(w
ith s
pecia
l har
ness
) P
/N: 2
4890
1
Plug
bot
h Br
eako
ut S
witc
hes
#229
222
into
MC
Harn
ess
#218
901
at D
Rec
epta
cle
of H
arne
ss #
2159
01.
If th
is is
not
follo
wed,
Br
eako
ut w
ill n
ot fu
nctio
npr
oper
ly.
OR
AN
GE
(M0)
BLU
E
RE
DR
ED
AC
US
EN
SO
R(IN
TER
IOR
SID
E)
AC
US
EN
SO
R(E
XTE
RIO
R S
IDE
)
AC
US
EN
SO
R(IN
TER
IOR
SID
E)
AC
US
EN
SO
R(E
XTE
RIO
R S
IDE
)
A do
or s
top
is n
eede
d at
the
cent
er o
f the
hea
der t
o st
opth
e do
ors
inde
pend
ently
.
ENCO
DER
12VD
C
Plug
Roc
ker S
witc
h #2
1982
1-01
into
MC
Harn
ess
#218
901
at C
Rec
epta
cle
of #
2159
01ha
rnes
s.
If th
is is
not
follo
wed
, Br
eako
ut w
ill n
ot fu
nctio
nan
d th
e Br
eako
ut S
witc
hes
#229
183
may
wel
d sh
utan
d ne
ed to
be
repl
aced
.
Bre
akou
t Sw
itch
Har
ness
Ext
ensi
on22
9220
-00
MIC
ROP
ROCE
SSO
R C
ONT
RO
LLER
(MC)
(with
spe
cial h
arne
ss)
P/N
: 24
8901
JUM
PER
PLU
G F
OR
SIM
ULTA
NEO
US P
AIR
P/N:
119
826
Dual Operator Wiring Diagram
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 8 -
ACUSENSOR/ACUMOTIONThe header is wired from the factory so that the activation circuitry on the exterior sensor is turned off in One Way Traffic Mode (the safety circuitry remains active and can not be turned off). The exterior sensor is located on the side of the header in the direction of panic or panel breakout. This can easily be reversed in the field by swapping the connectors where each sensor plugs into the main harness.
1
234
Red
Yellow
Red
Red
Black
White
Green
Black
White
Green
1234
1234
Acusensor Harness (#229184)
1
234
1234
Acusensor Harness (#229184)
RedBlack
White
Green
Green
White
BlackRed
Brown
GrayGray
1234
Yellow
Yellow
4
321 1
234
Red
YellowGray
Acusensor Extension Harness(#229267-01 48" Long)(#229267-02 24" Long)
4
321 1
234
Red
YellowGray
Acusensor Extension Harness(#229267-01 48" Long)(#229267-02 24" Long)
4
321
4
32
1
Brown
Orange
GreenRed
Brown
Red
Black
or
Main Harness
4
321
432
1
Main Harness
Brown
Orange
GreenRed
Brown
Red
Black
or
DN 0003
ExteriorSensor
InteriorSensor
ExteriorSensor
InteriorSensor
AcusensorPN 148902
Acumotion1410364
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 9 -
OFF OFF Auto Mode. Both sensor signals are available Electric Lock is always unlocked.
OFF ON Night Mode. None of the sensor signals will be accepted. Sensors will provide threshold safety and electric lock is always locked. Activation must occur by means of an exterior activation device such as a card reader or key switch.
ON ON Hold Open Mode. The door keeps the full open point, not affected by sensors. Electric Lock is always unlocked.
ON OFF One Way Traffic. The interior sensor activates the door; the exterior sensor provides threshold safety. Electric Lock is locked until an interior activation is received
MODE SWITCH TABLEMO M1 ModeOFF OFF Automatic ModeOFF ON Night ModeON ON Hold Open ModeON OFF One Way Mode
The table at right summarizesthe functions as outlined above:
MO M1 Results
How Door Function Modes are Achieved via the Rocker SwitchesBy alternately switching the two MO & M1 (orange wires) on the microprocessor harness to RED (common) the various door modes such as HOLD OPEN mode, EXIT mode, NIGHT mode etc. are achieved. Refer to the tables below.
(Off = not switched to common On = switched to common)
Sliders Electrical Manual
NABCO ENTRANCES INC www.nabcoentrances.com - 10
Holding Beams (Activation—Hold Open) The Holding Beam is a factory-installed unit consisting of an emitter, detector and control box. They are flush mounted in door frames and/or jamb tubes, facing each other along the threshold. A pulsed, infrared light beam is continuously transmitted across the door opening. Interruption of the beam will switch the White holding beam input wire to Red (Common). This will cause the system to re-activate and hold open until the interruption is cleared.
13 Yellow 12 G
ray 11 Yellow 10 G
ray 9 Yellow 8 B
lue 7 Yellow 6 B
lue
Brown
Green
Blue
RedBlue
Brown
Black
Blue
Green
Red
White
Red
Orange
YellowJacket color
ConnectEach Terminal
the Same
BraidedShield
Plastic Conductor
Optex Controller and One RCVR & One TRANSPT. NO. 149710-01
EMTR 1Gray
BlueRCVR 2
RCVR 1Blue
EMTR 2Gray
Brown
Red
Optex OS-10CController
Red
Term # & Color
Not used
Exterior Motion Sensor
Interior Motion Sensor
Panic Breakout Switch or Plug with
Blue Jumper connects
here.
Panic Breakout Switch or Plug with
Blue Jumper connects
here.
Panic Breakout Switch or Plug with
Blue Jumper connects
here.
PN 15-10288DN 0004
Terminal #6
Terminal #1
Terminal #13
Terminal #5
Optex OA-10C Beams on a GT-1175Wiring Diagram for Holding Beams(U04 and Higher)
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 11
Holding Beam (Breakout—Power Interrupt)The Holding Beam is a factory-installed unit consisting of an emitter, detector and control box. They are flush mounted in door frames and/or jamb tubes, facing each other. A pulsed, infrared light beam is continuously transmitted across the door opening. Interruption of the beam by breaking out a door panel will interrupt the blue wire power down loop. This will cause the system to stop operating until the door panel is repositioned and latched.
Term # & Color
Panic Breakout Switch or Plug with
Blue Jumper connects
here.
Holding Beams
Panic Breakout Switch or Plug with
Blue Jumper connects
here.
Interior Motion Sensor
Exterior Motion Sensor
Optex Controller and One RCVR & One TRANSPT. NO. 149710-01
PN 15-10287DN 0005
Terminal #5Terminal #1
Terminal #13Terminal #6
Optex OA-10C Beams on a GT-1175Wiring Diagram for Breakout Beams(U04 and Higher)
Plastic ConductorShieldBraided
the SameEach Terminal
Connect
Jacket color Yellow
13 Yellow 12 G
ray 11 Yellow 10 G
ray 9 Yellow 8 Blue 7 Yellow 6 Blue
GrayEMTR 1
Optex OS-10CController
BlueRCVR 1
Red Jumper
Orange
Red
RedBrown
White
Red
Green
Blue
Black
BlackBlue
Brown
PT. NO. 1110187Hold Beam Pigtail
BlueRed
Blue
Green
Brown
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 12
Diagram for connecting push plates and or card readers for Night mode.Attach the normally open contacts across the red and black wire on either the rocker or key switches.
HOLD
OPE
N
FULL
Blac
k
Blac
k
Red
Gre
enR
ed
Whi
te
Blue
Red
Red
AUTO
NIG
HT
ON
DO O R O PERATIO NO N L Y
O FF REDU
CED
OPEN
Whi
te
ON
E W
AY
Blue
Blu
eG
reen
Ora
nge
MOOr
ange
M1
Red
Blue
Whi
te
Gree
n
Whi
te
Gree
n
Whi
te
Gree
n
Roc
ker
Switc
hC
onne
ctor
Blue
Blu
e
Blue
Red
Blue
Blac
k
Blac
k
Red G
reen
Whi
te
Blue
Red
Gre
enRe
d
Blue
Red
ON
RE
DU
CE
D O
PE
N
OFF
NIG
HT
TWO WAY
ON
E W
AY
HOL
D O
PE
N
Red
Blac
k
Whit
e
Whit
eBl
ack
FULLOPEN
Red
Blue Gre
en
Blac
k
Whit
e
RE
DU
CE
D
Red
Whi
te
Bla
ckG
reen
Blu
e
Push
but
tom
sw
itch
durin
g ni
ght m
ode.
Red (
#1)
Whi
te (#
6)Bl
ack
(#2)
Red
(#8)
Gree
n (#
1)B
lue (
#4)
Push
but
tom
sw
itch
durin
g ni
ght m
ode.
Push
but
tom
sw
itch
durin
g ni
ght m
ode.
DN
000
7
OLD
ROCK
ER S
WIT
CHU1
6 an
d ea
rlier
mod
els.
NEW
ROC
KER
SWIT
CHU1
6 an
d la
ter m
odel
s.PN
219
821-
01
KEY
SWIT
CHPN
219
820
H.O
.N
IGH
T
FULL
STO
P
AU
TOE
XIT
Clos
ing
cont
acts
with
doo
rin
NIG
HTm
ode
open
sdo
or.
Brea
kaw
ayC
onne
ctor
s
Back
side
of s
witc
h.
1175
Micr
opro
cess
or W
ire D
iagr
amAc
tivati
on w
ith N
ight
mod
e.Co
nnec
t car
d re
ader
and w
all pl
ateno
rmall
y ope
n dry
cont
acts
as s
hown
.Ac
cess
in th
e hea
der.
Back
side
of s
witc
h.
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 13
MO
V10
1576
RELA
Y(DC
12V)
2292
40
RECT
IFIE
R11
9929
-01
AC24
V
TRAN
SFO
RMER
(GRN
)
AC11
5V (Y
EL)
(BLK
/WHT
)ELEC
TRIC
LO
CK /
STRI
KE
Fail
Safe
Type
(BLK
/WHT
)
ON O
PEN
>>>
CLO
SECL
OSE
D
LOCK
EDUN
LOCK
ED (O
N)
ACTI
VATE
SIGN
AL
DOOR
OUTP
UTSI
GNAL
time
delay
(0.2
5~1s
ec)
time
delay
(0.2
5~1s
ec)
CLO
SED
LOCK
EDHa
ndy
Term
inal
: Au
x. O
utpu
t [0]
, tim
e de
lay
[0]~
[3]
Mod
e In
put :
One
Way
Tra
ffic
Mod
e or
Nig
ht M
ode
(OR)
(OR)
OUT
+ (V
IOLE
T)
OUT
- (G
RAY)
7 (R
ED)
Wire
Nut
1031
25N
o.
MIC
ROPR
OCES
SOR
CON
TROL
LER
GY
RO
TE
CH
- 2
4890
1H
AND
Y TE
RM
INAL
(6P)
SEN
SOR
(12P
)
1.Pl
ease
adj
ust t
his
oper
ator
as
per i
nstru
ctio
n m
anua
l.2.
Turn
the
powe
r off,
bef
ore
open
ing
the
box.
3.Do
n't o
pen
this
box
exc
ept f
or re
plac
ing
fuse
.
Othe
rwis
e, th
e wa
rrant
y will
be
term
inat
ed.
4.Re
pair
of th
is u
nit e
xcep
t by L
anso
n In
dust
ries,
Inc.
m
ay c
ause
sof
twar
e an
d ha
rdwa
re m
alfu
nctio
n.
USE
USE
CA
UT
ION
US
E [S
LID
ER
/SW
ING
ER]
For
cont
inue
d pr
otec
tion
agai
nst
fire,
rep
lace
only
with
sam
e ty
pe a
nd r
atin
gof
fus
e.WA
RN
ING
FUSE
INS
IDE
RATI
NG:1
25V,
4ASI
ZE:5
.2 x
20m
m
GYR
O T
ECH
LAN
SON
IND
UST
RIE
SIN
C.
EN
TR
AN
CE
S
CO
LOR
BR
OW
NR
ED
BLA
CKW
HIT
E
GR
EEN
OR
ANG
E
OR
ANG
EO
RAN
GE
YE
LLO
WB
LUE
VIO
LET
GR
AY
7 61 6B9DC
12V
SY
MBO
L
H M0
M1
62 BA
OU
T +
OU
T -
SQ
1 2 3 4NO
.
5 6 7 8 9 10 11 12
POW
ER S
OURC
E (4
P)
OPER
ATOR
(6P)
EM
PTY
115V
AC
HO
TE
MPT
Y
115V
AC
CO
MM
ON
WH
ITE
BLA
CK
1 2 3 4
CO
LOR
NO
.
MO
TOR
V P
HAS
EE
NCO
DE
R 12
VDC
EN
COD
ER
A P
HA
SE
MO
TOR
U P
HAS
EE
NCO
DE
R G
NDE
NCO
DE
R B
PH
AS
E
OR
ANG
ER
ED
BR
OW
N
YE
LLO
W
CO
LOR
BLU
EB
LACK
1 2 3 4 5 6NO
.
DN 0008
KIT
PN 2
1104
71-0
2N
OTE
: LO
CK
WO
RKS
ON
LY IN
NIG
HT
& EX
IT M
ODE
S
BRO
WN
1431
97-0
5
VIO
LET
1016
49
9DC1
2V(B
ROW
N)
12
34
56
78
9
Electric Locks—Fail Safe
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 14
Wire
Nut
1031
25R
ELAY
(DC
12V)
2292
40
MO
V10
1576
BRO
WN
1431
97-0
5VI
OLE
T 10
1649
(GR
N)
(OR
)
(OR
)
AC
24V
TRAN
SFO
RM
ERA
C11
5V
REC
TIFI
ER11
9929
-01
KIT
PN 2
1104
71-0
1N
OTE
: LO
CK
WO
RKS
ON
LY IN
NIG
HT
& EX
IT M
OD
ES
No.
MIC
RO
PR
OC
ES
SO
R C
ONT
RO
LLE
RG
YR
O T
EC
H -
24
890
1
HAND
Y TE
RMIN
AL (6
P)SE
NSOR
(12P
)
1.Pl
ease
adj
ust t
his
oper
ator
as
per i
nstru
ctio
n m
anua
l.2.
Turn
the
pow
er o
ff, b
efor
e op
enin
g th
e bo
x.3.
Don
't op
en th
is b
ox e
xcep
t for
repl
acin
g fu
se.
O
ther
wis
e, th
e w
arra
nty
will
be
term
inat
ed.
4.R
epai
r of t
his
unit
exce
pt b
y La
nson
Indu
strie
s, In
c.
may
cau
se s
oftw
are
and
hard
war
e m
alfu
nctio
n.
US
E
US
E
CA
UT
ION
US
E [S
LIDE
R/S
WIN
GE
R]
For
con
tinue
d pr
otec
tion
agai
nst f
ire,
repl
ace
only
with
sam
e ty
pe a
nd r
ating
of f
use.
WA
RN
ING
FUSE
IN
SID
ER
ATIN
G:1
25V,
4ASI
ZE:5
.2 x
20m
m
GYR
O T
ECH
LAN
SON
IND
UST
RIE
SIN
C.
EN
TR
AN
CE
S
CO
LOR
BRO
WN
RED
BLA
CK
WHI
TE
GRE
EN
ORA
NG
E
ORA
NG
EO
RAN
GE
YEL
LOW
BLU
EV
IOLE
TG
RAY
7 61 6B9DC1
2VS
YM
BO
L
H M0
M1
62 BA
OU
T +
OU
T -
SQ
1 2 3 4NO
.
5 6 7 8 9 10 11 12
POW
ER S
OURC
E (4
P)
OPER
ATOR
(6P)
EM
PT
Y
115V
AC
HO
TE
MP
TY
115V
AC
CO
MM
ON
WHI
TE
BLA
CK
1 2 3 4
CO
LOR
NO
.
MO
TO
R V
PH
AS
EE
NCO
DER
12V
DC
ENC
ODE
R A
PH
ASE
MO
TO
R U
PH
AS
EE
NCO
DER
GN
DE
NCO
DER
B P
HAS
E
OR
ANG
ER
ED
BR
OW
N
YE
LLO
W
CO
LOR
BLU
EB
LAC
K
1 2 3 4 5 6NO
.O
UT+
(V
IOLE
T)
OU
T-
(GR
AY)
7 (R
ED)
DN 0009
9DC
12V
(BR
OW
N)
(YEL
)
Wire
Nut
1031
25
Fail
Secu
re
Type
(BLK
/W
HT)
(BLK
/W
HT) EL
ECTR
IC L
OC
K / S
TRIK
E
ON
OPEN
>>>
CLO
SECL
OSED
LOCK
EDUN
LOCK
ED (O
N)
AC
TIV
ATE
SIG
NA
L
DO
OR
OU
TPU
TS
IGN
AL
time
delay
(0.2
5~1s
ec)
time
delay
(0.2
5~1s
ec)
CLOS
ED
LOCK
EDHa
ndy
Term
inal
: Au
x. O
utpu
t [0]
, tim
e de
lay
[0]~
[3]
Mod
e In
put :
One
Way
Tra
ffic
Mod
e or
Nig
ht M
ode
12
34
56
78
9
Electric Locks—Fail Secure
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 15
Par
t No.
1110
431
BD
raw
ing
No.
PA
RT
NA
ME
:
MA
TE
RIA
L:
SP
EC
IFIC
ATI
ON
S:
SH
EE
T #
:1
OF
1
DA
TE:
SC
ALE
:D
RA
WN
BY
:A
PP
. BY
:
4-21
-03
JcMB
Non
e
TOLE
RA
NC
ES
(UN
LESS
NO
TED)
FR
AC
TIO
NA
L___
___±
1 64
X _
____
____
____
± .0
30X
X _
____
____
___±
.015
XX
X _
____
____
__±
.005
AN
GLE
___
____
____
± 1 2°
Dis
tribu
tor T
est H
arne
ss K
it
ITE
MQ
TYP
AR
T N
O.
DE
SC
RIP
TIO
N
1110
426
11
Doo
r Pos
ition
Har
ness
for M
agnu
m C
ontro
l11
1042
82
1Te
st H
arne
ss fo
r GT
1100
31
1110
427
Test
Har
ness
for G
T 30
0/40
0/50
0 A
nalo
g C
ontro
l
ER
N 8
94R
EVIS
IONS
DAT
E6-
11-0
3
AN
ALO
G C
ON
TRO
LTE
ST
HA
RN
ES
S F
OR
GT
300/
400/
500
LAB
EL:
TES
T H
AR
NE
SS
FO
R G
T 11
00LA
BE
L:
CO
NTR
OL
GT
300/
400/
500/
710
MA
GN
UM
D
OO
R P
OS
TIO
N T
ES
T H
AR
NE
SS
FO
R
LAB
EL:
12
34
8
76
5
Pan
ic S
witc
h B
ypas
s P
lug
1210
324
26
Mic
ropr
oces
sor S
witc
h Ju
mpe
r Plu
g1
511
9826
Mic
ropr
oces
sor T
est P
lug
14
1110
429
Inst
ruct
ion
Set
for D
istri
buto
r Tes
t Har
ness
Kit
18
1510
430
Mic
ropr
oces
sor J
umpe
r Plu
g1
711
5941
DN
0070
May
200
3P
art #
15-
1043
0T
est K
it M
anua
l
Har
ness
Kit
Dis
tribu
tor T
est
Inst
ruct
ion
Set
for
Tec
hnic
al A
ssis
tanc
e: 8
66-6
22-8
325
Fax
:
888
-679
-331
9P
hon
e: 8
77-6
22-2
694
Mus
keg
o, W
I 531
50P
.O.
Bo
x 90
6S
82
W18
717
Ge
min
i Driv
eN
AB
CO
EN
TR
AN
CE
S IN
C.
TES
T P
LUG
MIC
RO
PR
OC
ES
SO
RLA
BE
L:
JUM
PE
R P
LUG
MIC
RO
PR
OC
ES
SO
RLA
BE
L:
BY
PA
SS
PLU
GP
AN
IC S
WIT
CH
LAB
EL:
SW
ITC
H J
UM
PE
R P
LUG
MIC
RO
PR
OC
ES
SO
RLA
BE
L:
Trouble Shooting
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 16
Troubleshooting
1. Acusensor does not seem to reach out far enougha) Move the area lever on the side of the Acusensor to a higher number.b) Increase the opening speed on the door with the Handy Terminal.c) If desired, replace Acusensor with Acumotion for greater detection range.
2. Acusensor is not seeing people accessing the door from the side.a) Turn on more of the area switches on the front of the Acusensor.b) Door is set to One Way Traffic mode and sensor is switched out. Set door to Auto mode.
3. When the doors are panicked open, the system does not shut down.a) Check the wiring of the power down switch in the fixed panel or bottom of header. (Full Open
Units.) Blue (BA) circuit must go open for system to shut down.b) Check the wiring of the breakout beam circuit. (Surface Applied Units.) Blue (BA) circuit must go
open for system to shut down.
4. Doors do not move when power is applied or Handy Terminal connected.a) Confirm the swing panel is closed completely.b) Confirm Blue (BA) circuit is not open. Zero VDC between Red and Blue on microprocessor har-
ness for correct operation. If 12VDC circuit is open.b) Check the power down magnet in the top rail of the swing panel is installed and aligned with the
magnetic power down switch in the bottom of the header.c) Confirm rocker is switch is set to ON not OFF.
5. The cover on the Acusensor will not snap on.a) Install thin washers to space the Acusensor off from the header and provide clearance for the cover.
6. Doors move very slowly when the Handy Terminal is connected. (Only happens after “Stroke Cycle” initiated.)
a) This is normal. It is “learning” the door stroke.b) After learning the stroke, the Handy Terminal will prompt you with options
7. The doors do not open completely.a) Look for obstructions in the track as well as inside the header. Check to make sure that the belt
clips are not hitting something.b) On Full Open units be sure that the interlock clips are adjusted properly.c) Check for any racking in the door.b) Check that the mode switch on the panel is not in “Reduced Opening” mode.c) Use the Handy Terminal and reinitialize the system.
8. I want to eliminate all outside switches and sensors and test the system with the Handy Terminal.a) Disconnect the 12-pin connector from inside the microprocessor and install the special connector
jumper tool p/n 115941 into its place.b) The system will consist of only the motor, operator and control box (Microprocessor). The Handy
Terminal will be the only means of operating the door.
Sliders Electrical Manual
NABCOENTRANCES INC www.nabcoentrances.com - 17
Troubleshooting
9. I want to reset the system back to the factory settings.a) Plug in Hand Terminal and wait for the door to close.b) At “Swing/Slide/Stroke?” enter YES.c) At “Swing Door Y or N?” enter YES (even though you have a slide door).d) Door will try to initialize as a swing door and reset the settings.e) At “Swing/Slide/Stroke?” enter YES.f) At “Swing Door Y or N?” enter NO.g) The system will now initialize as a slide door to the factory settings.h) You must set the door stroke from the Handy Terminal from the prompts at this point.
10. Door does not run unless holding beam is interrupted.a) The holding beam connector (it has a red and white wire in it) in the main harness may be inadver-
tently plugged into one of the “Power Down” (blue wires) plugs. Any vacant “Power Down” plugs should have a blue jumper installed.
For technical assistance call: 866-622-8325or engineering at: 877-622-2694