32
Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Upload: others

Post on 18-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Automation componentsBauteile für Automatisierung

POWER RELAYSINDUSTRIESRELAIS

PR 45, 46TRP 614, 624, 66, 67

TRP 651, 652

Page 2: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Universal power relaysPower relays for industrial universal purpose with 1, 2, 3 or 4 change- over contacts, available in AC or DC coils with plug-in terminals for sockets or for circuit.The relays are dustproof with IP 40 according to EN 60 with insulation parts from nonflammable material.

UniversalindustrierelaisRelais für den Universaleinsatz mit wahlweise 1, 2, 3 oder 4 Umschaltkontakten.Lieferbar mit Wechselstrom- oder Gleichstromerregung als steckbares Relais für Sockels oder für gedruckte Schaltun-gen. Die Relais sind staubgeschütz und entsprechen Schut-zart IP 40 nach EN 60529.Die Isolierteile sind aus selbstver-löschenden Kunststoffen gefertigt.

Hauptmermale- Monostabile, neutrale Relais- Gleich oder Wechelstromerregung- Hohe Schaltleistung- 1, 2, 3 oder 4 Umschaltkontakt- 1, 2 oder 3 Arbeitskontakt mit ca. 3 mm Kontaktdistanz (nur TRP 66/67)- Sockelzubehör- VDE, UL, Zulassung, CE

Main characteristic- Monostable, neutral relays- DC or AC coils- High switching power- 1, 2, 3 or 4 change- over contacts- 1, 2 or 3 make contacts with approx. 3 mm contact dis-tance (only TRP 66/67)- Sockets and accessories- VDE, UL approval, CE

RELAY

PR 45 – relay with 1, 2 or 3 CO contacts

PR 46 – relay with 1, 2 or 3 contacts for printed circuits

TRP 614 – relay with 4 CO contacts

TRP 624 – relay with 4 CO contacts for for printed circuits

TRP 66 – relay with 1, 2 or 3 CO contacts or 1, 2, 3 make contacts with con-tact distance approx. 3 mmTRP 67 – equal to TRP 66 but for printed circuitsTRP 651 – relay with one CO contacts for current up to 25 ATRP 652 – relay with two CO contacts for current up to 16 A

RELAY MOUNTING- to the socket- with two screws B2.2 x 6.5 DIN7971 directly via cover or via bracket TLK 1041 to the plate- with adapter TLK 1042 on the rail 35 mm- via socket on the rail or plate

- on printed circuit board

- to the socket- with two screws B2.2 x 6.5 DIN7971 directly via cover or via bracket TLK 1041 to the plate- with adapter TLK 1042 on the rail 35 mm- via socket on the rail or plate- on printed circuit board

- with two screws B2.2 x 6.5 DIN7971 directly via cover or via bracket TLK 1041 to the plate- with adapter TLK 1042 on the rail 35 mm

- on printed circuit board

- with two screws B2.2 x 6.5 DIN7971 directly via cover or via bracket TLK 1041 to the plate- with adapter TLK 1042 on the rail 35 mm

RELAY CONNECTION- for faston terminals 2.8 x 0.8 mm- direct soldering of wire to the terminals of relay- via socket- via socket on printed circuit- via socket

- through printed circuit

- for faston terminals 2.8 x 0.8 mm- direct soldering of wire to the terminals of relay- via socket- via socket on printed circuit- via socket- through printed circuit

- for faston terminals 4.8 x 0.5 mm- direct soldering of wire to the terminals of relay

- through printed circuit

- for faston terminals 6.3 x 0.8 mm- direct soldering of wire to the terminals of relay

ACCESORIESbracket TLK 1041adapter TLK 1042socket TLK 1141socket TLK 1143socket TLK 1441

bracket TLK 1041adapter TLK 1042socket TLK 1161socket TLK 1163socket TLK 1461

bracket TLK 1041adapter TLK 1042

bracket TLK 1041adapter TLK 1042

RELAIS

PR 45 – Relais mit 1, 2 oder 3 Wechsler

PR 46 – Relais mit 1, 2 oder 3 Wechsler für gedruckte Schaltung

TRP 614 – Relais mit 4 Wechsler

TRP 624 – Relais mit 4 Wechsler für gedruckte SchaltungTRP 66 – Relais mit 1, 2 oder 3 Wechsler der 1, 2, 3 Arbeitskontakt mit Kontaktdis-tanz ca. 3 mm

TRP 67 – gleich TRP 66 aber für gedruckte SchaltungTRP 651 – Relais mit 1 Wechsler für Strom bis 25 ATRP 652 – Relais mit 1 Wechsler für Strom bis 16 A

RELAIS BEFESTIGUNG- auf Sockel- mit zwei Schrauben B2,2 x 6,5 DIN 7971 direkt über Deckel oder über Befestigungskonsole TLK 1041 auf Platte- mit Schnappvorrichtung TLK 1042 auf Schiene 35 mm- über Sickel auf Schiene oder Platte

- auf gedruckte Schaltung

- auf Sockel- mit zwei Schrauben B2,2 x 6,5 DIN 7971 direkt über Deckel oder über Befestigungskonsole TLK 1041 auf Platte- mit Schnappvorrichtung TLK 1042 auf Schiene 35 mm- über Sickel auf Schiene oder Platte- auf gedruckte Schaltung

- mit zwei Schrauben B2,2 x 6,5 DIN 7971 direkt über Deckel oder über Befestigungskonsole TLK 1041 auf Platte- mit Schnappvorrichtung TLK 1042 auf Schiene 35 mm- auf gedruckte Schaltung

- mit zwei Schrauben B2,2 x 6,5 DIN 7971 direkt über Deckel oder über Befestigungskonsole TLK 1041 auf Platte- mit Schnappvorrichtung TLK 1042 auf Schiene 35 mm

ANSSSCHLUSSART- für Fastonanschlüsse 2,8 x 0,8 mm- Drahtlötung direkt auf Anschlüsse- über Sockel- über Sockel auf gedruckte Schaltung- über Sockel

- durch gedruckte Schaltung

- für Fastonanschlüsse 2,8 x 0,8 mm- Drahtlötung direkt auf Anschlüsse- über Sockel- über Sockel auf gedruckte Schaltung- über Sockel- durch gedruckte Schaltung

- für Fastonanschlüsse 4,8 x 0,5 mm- Drahtlötung direkt auf Anschlüsse

- durch gedruckte Schaltung

- für Fastonanschlüsse 6,3 x 0,8 mm- Drahtlötung direkt auf Anschlüsse

ZUBEHÖRBefestigungskonsole TLK 1041Schnappvorrichtung TLK 1042Sockel TLK 1141Sockel TLK 1143Sockel TLK 1441

Befestigungskonsole TLK 1041Schnappvorrichtung TLK 1042Sockel TLK 1161Sockel TLK 1163Sockel TLK 1461

Befestigungskonsole TLK 1041Schnappvorrichtung TLK 1042

Befestigungskonsole TLK 1041Schnappvorrichtung TLK 1042

Page 3: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Technical dataContact data

Technische AngabenKontaktseite

Coils Coil rated

voltage

Un(V)6

12244860

110220230380*

Operative voltage rangeat 20ºC

Coil resistanceat 20ºC

DC 50Hz 60HzRn (Ω) ± 10%

28110440

174027509000

3600039000

Operate Uop≤(V)

4.89.6

19.238.44888

176184304

UmaxDC ≤(V)

918367391

168336351579

UmaxAC≤(V)9.519387695

174349365603

WicklungenWicklungs-

-nenn-spannung

Un(V)6

12244860

110220230380*

Betriebsspannungsbereichbei 20ºC

Wicklungswider-stand bei 20ºC

DC 50Hz 60HzRn (Ω) ± 10%

Ansprech Uan≤(V)

4.89.6

19.238.44888

176184304

UmaxDC ≤(V)

918367391

168336351579

UmaxAC≤(V)9.519387695

174349365603

Coil data at ambient temperature 20 ºCRated power: app. 1.3 W; 2 VAOperate power: app. 0.8 W; 1.2 VAMax. coil temperature: 155º CThermal coil temperature: 50 K/WOperate voltage: Uop ≤ 80% Un

Release voltage: Ure ≥ 10% Un (DC); Ure ≥ 15% Un (AC)Operative range: 1 EN 61810-1

Wicklungsangaben bei Umgebungstemp. 20 ºCNennleistung: app. 1.3 W; 2 VAAnsrechleistung: app. 0.8 W; 1.2 VAMax. Wicklungstemperatur: 155º CWärmewiderstand: 50 K/WAnsprechspannung: Uop ≤ 80% Un

Rückfallspannung: Urü ≥ 10% Un (DC); Urü ≥ 15% Un (AC)Arbeitsbereich: 1 EN 61810-1

Relay type:

Contact material:Rated current:Max. switch-on current:(4 s, 10% duty cycle)Max. operating voltage:Max. switching power:Min. switching load:Contact resistance:(New relay)Max. operatingfrequency:Mechanical life:Electrical life:

PR 45PR 46

TRP 614TRP 624

TRP 66TRP 67

TRP 652 TRP 651

AgNi 1010 A

20 A

10/16 A

20/32 A

10 A

20 A

16 A

32 A

25 A

50 A250 VAC 400/250 VAC 250 VAC

12 VAC 100mA ≤ 100mΩ

(measuring method CA 3, IEC 61810-7)1000 operat./h at rated load36000 oerat./h at min. load

> 107 operatingsee diagram

2500 VA 2500 VA 4000 VA 4000 VA 6000 VA

Relais tip:

Kontaktmaterial:Nennstrom:Max. Einschalstrom:(4 s, 10% ED)Max. Schaltspannung:Max. Schaltleistung:Min. Schaltbelastung:Kontaktwiderstand:(Neuzustand)Max. Schalthäufigkeit:

Mechanische Lebensdauer:Elektrische Lebensdauer:

PR 45PR 46

TRP 614TRP 624

TRP 66TRP 67

TRP 652 TRP 651

AgNi 1010 A

20 A

10/16 A

20/32 A

10 A

20 A

16 A

32 A

25 A

50 A250 VAC 400/250 VAC 250 VAC

12 VAC 100mA≤ 100mΩ

(Messmethode CA 3, IEC 61810-71000 Schaltsp./h bei Nennlast

36000 Schaltsp./h bei min. Last> 107 SchaltspieleSiehe Diagramm

2500 VA 2500 VA 4000 VA 4000 VA 6000 VA

5.725

100400630

200077008800

21500

52080

320510

175070007500

28110440

174027509000

3600039000

5.725

100400630

200077008800

21500

52080

320510

175070007500

* only TRP 66/67 * nur TRP 66/67

Sonstige DatenPrüfspannung (1min.) Kontakt - Wicklung: ≥ 2 kVeff, 50 Hz ≥ 2.5 kVrms – TRP 66, 67 Kontakt - Kontakt: ≥ 1 kVeff, 50 Hz nur Arbeitskontakt: ≥ 2.5 kVrms – TRP 66, 67 zwischen Kontaktsätzen: ≥ 2 kVeff, 50 HzAnsprechzeit bei Un ≥ 20 ms

Reduction factorReduktionsfaktor

Other dataTest voltage (1min.) contact – coil: ≥ 2 kVrms, 50 Hz ≥ 2.5 kVrms – TRP 66, 67 contact – contact: ≥ 1 kVrms, 50 Hz only make contact: ≥ 2.5 kVrms – TRP 66, 67 between contact sets: ≥ 2 kVrms, 50 HzOperate time at Un ≥ 20 ms

Operative voltage rangeBetriebsspannungsbereich

0,0

0,5

1,0

1,5

2,0

2,5

-40 -30 30 40 50 60-10 0 10 20-20

Ope

rativ

e vo

ltage

rat

ioA

rbei

tssp

annu

ngsv

erhä

ltnis

Ambient temperature (°C)Umgebungstemperatur

Umax /Un(AC)

Umax/Un(DC)

Uop/UnUan/Un

0,30,4 0,21 0,8 0,6

F

cos

0,4

0,5

0,6

0,7

0,80,9

1 Operations eff. =operations (cos =1) x F

Schaltzahl eff. =Schaltzahl (cos =1) x F

Page 4: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Ordering data for TRP 66, TRP 67

Basic designationType of terminals:6 – for socket, faston or soldering7 – for printed circuitNumber of change over contacts: 1, 2 or 3Contact form:1 – change over contact2 – make contact (contact distance approx. 3 mm)Rated voltage of coil and type of voltage: (DC, 50 Hz, 60 Hz)

Bestellangaben für PR 45/46, TRP 61/62

TypenschlüsselAnschlüsstyp:5 – für Sockel, Faston oder Drahtlötung6 – für gedruckte SchaltungAnzahl der Umschaltkontakte: A, B, C oder 4 für TRP 6Spannungstyp: 0 – DC, 5 – 50 Hz, 6 – 60 HzWicklungnennspannung

Data subject to alteration Änderungen vorbehalten

Release time: ≤ 15 msBounce time: ≤ 5 msInsulation resistance (500 VDC): > 103 MΩVibration resistance (10-55 Hz): 3 gnShock resistance (11ms) functional: 10 gn destructive: 100 gnAmbient temperature for operating: -25 ºC to + 50 ºC for storage: -40 ºC to + 80 ºCProtection degree: IP 40, EN 60529Insulation class: 3-250, IEC 60664-1Mounting position: as desired, relay distance 10 mmRelay weight: 80 g

Rückfallzeit: ≤ 15 msPrellzeit: ≤ 5 msIsolationswiderstand (500 VDC): > 103 MΩVibrationsfertigkeit (10-55 Hz): 3 gnStossfestigkeit (11ms) zuverlässiges Schalten: 10 gn Beschädigunsgrenze: 100 gnUmgebungstemperatur in Betrieb: -25 ºC to + 50 ºC bei Lagerung: -40 ºC to + 80 ºCSchutzklasse: IP 40, EN 60529Isolationsgruppe: 3-250, IEC 60664-1Einbaulage: beliebig, Montageabstand 10 mmGewicht: 80 g

Max. switching capacity, DC loadGleichstrom-Lastgrenzkurve Belastung

Electrical life, resistive AC loadKontaktlebensdauer bei ohmscher AC Belastung

104

105

106

107

Ope

ratio

nsSc

haltz

ahl

Switching powerSchaltleistung

1 2 3 4 5

123

Ope

ratin

g cu

rren

tSc

halts

trom

Operating voltageSchaltspannung

20

kVA

n

U (V)

I (A

)

60 100 140 180 220 260

1625

610

4

1

2

0,40,6

0,1

0,2

6 4 123

5

1 – Relay TRP 6512 – Relay TRP 6523 – Relays PR 45/46 and TRP 66/67

1 – Relais TRP 6512 – Relais TRP 6523 – Relais PR 44/45 und TRP 66/67

1 – Relay TRP 651, resistive load2 – Relay TRP 652, resistive load Relays TRP 45/46 and TRP 61/62/66/673 – two contacts in series, resistive load4 – one contact, resistive load5 – two contacts in series, inductive load L/R = 40 ms6 – one contact, inductive load L/R = 40 ms

1 – Relais TRP 651, ohmsche Belastung2 – Relais TRP 652, ohmsche Belastung Relais TRP 45/46 und TRP 61/62/66/673 – zwei Kontakte in Serie, ohmsche Belastung4 – ein Kontakt, ohmsche Belastung5 – zwei Kontakte in Serie, induktive Belastung L/R = 40 ms6 – ein Kontakt, induktive Belastung L/R = 40ms

PR 4TRP 6

5, 61, 2 X X XXX V

Ordering data for PR 45/46, TRP 61/62

Basic designationType of terminals:5 – for socket, faston or soldering6 – for printed circuitNumber of change over contacts: A, B, C or 4 for TRP 6Voltage type: 0 – DC, 5 – 50 Hz, 6 – 60 HzRated voltage of coil

PR 4TRP 6

5, 61, 2 X X XXX V

TRP 6 X X X XXX,XXXX

Bestellangaben für TRP 66, TRP 67

TypenschlüsselAnschlüsstyp:6 – für Sockel, Faston oder Drahtlötung7 – für gedruckte SchaltungAnzahl der Umschaltkontakte: 1, 2 oder 3Kontakttyp:1 – Umschaltkontakt2 – Arbeitskontakt (Kontaktdistanz ca. 3 mm)Wicklungnennspannung und Spannungstyp: (DC, 50 Hz, 60 Hz)

TRP 6 X X X XXX,XXXX

Page 5: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Dimensions and terminals arrangementAbmessungen und Anschlussbelegung

PR 45 PR 46 TRP 614 TRP 624

PR 4xAx

PR 4xBx

TRP 4xCx

TRP 6x4x

TRP 65

TRP 651 TRP 652

TRP 66, TRP 67

TRP 6x21

TRP 6x31

TRP 6x11

Page 6: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

AccessoriesZubehör

SocketsSockels

BracketBefestigungskonsole

AdapterSchnappvorrichtung

TLK 1041 TLK 1042

Safety clipHaltefeder

Relays PR 45 and TRP 614

a425955

b363236

for socketsTLK 1141, TLK 1161TLK 1441TLK 1461

Relais PR 45 und TRP 614

a425955

b363236

für SockelTLK 1141, TLK 1161TLK 1441TLK 1461

TLK 1143for/für PR 45

TLK 1161 for/für TRP 614 TLK 1461 for/für TRP 614

TLK 1441 for/für PR 45

TLK 1163for/für TRP 614

TLK 1141for/für PR 45

Page 7: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 8: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 9: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 10: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 11: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 12: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 13: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 14: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 15: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 16: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 17: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 18: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 19: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 20: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652
Page 21: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Automation componentsBauteile für Automatisierung

POWER RELAYSINDUSTRIERELAIS

TRP 68, 69

Page 22: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

TRP 68, 69

IndustrierelaisKompaktes Relais für den industriellen Einsatz mit wahlweise 1, 2 oder 3 Umschalkontakten.Lieferbar mit Wechselstrom- oder Gleich-stromerregung als steckbares Relais mit 8 oder 11 polig Anschlüssbelegung.Die Relais sind staubgeschütz und entsprechen Schutzart IP 50 nach EN 60529. Die Isolierteile sind aus selbstverlöschenden Kunststoffen gefer-tigt.

Hauptmerkmale- Monostabile, neutrale Relais- Gleich oder Wechselstromerregung- Hohe Schaltleistung- 1, 2 oder 3 Umschaltkontakte- 8 oder 11 polige Anschlüsse- Eine oder zwei Schaltstellungsanzeigen- LED – Schaltstellungsanziege- Handprüftaste- Freilaufdiode bei DC Typen- Sockelzubehör- VDE, CE, UL Zulassung

Industrial RelaysCompact relays for industrial purpose with 1, 2 or 3 change – over contacts, avaiable in AC or DC coils with 8 or 11 pins plug – in terminals.The relays are dustproof IP 50 according to EN 60529 with insulations parts from nonflammablematerial.

Main characteristics- Monostable, neutral relays- DC or AC coils- High switching power- 1, 2 or 3 change – over contacts- 8 or 11 pins terminals- Single or double flag for switch indication- LED for switch indication- Manual test key- Protection diode for DC types- Socets and accessories- VDE, CE, UL approval

Relays TRP 68 and TRP 69 are versions with single or double flag.Single (red flag) appears when the relay is in the operated posi-tion. When the relay releases the red flag disappears.Double flag relay version has beside the red flag another yellowflag which remains latched, even when the relay release. Red flagin the window means that the relay has energized. Yellow flag inthe window means that the relay was energized but now it is in the released position. Yellow flag returns to its normal positionwith an arm on the top side of the relay.Relays TRP 68 and TRP 69 has also a test key on the top side of the relay for manual switching of the contacts.This key can be activated permanently with a safety clip for permanent relay switching.

Technical dataContact data

Relay type:Contact material:Rated current:Max. switch-on current: (4 s, 10% duty cycle)Max. operating voltage:Max. switching power:Min. switching load:Contact resistance:(New relay)Max. operating frequency:Machanical life:Electrical life:

Relais type:Kontaktmaterial:Nennstrom:Max. Einschaltstrom: (4 s, 10% ED)Max. Schaltspannung:Max. Schaltleistung:Min. Schaltbelastung:Kontaktwiderstand:(Neuzustand)Max. Schalthäufigkeit:

Mechanische Lebensdauer:Elektrische Lebensdauer:

TRP 68, TRP 69AgNi 10

10 A20 A

250 VAC, VDC

2500 VA 400 W12 VAC, 100 mA

≤ 100 mΩCA3, IEC 61810-7

1000 Schaltsp./h bei Nennlast36000 Schaltsp./h bei min Last

> 107 SchaltspieleSiehe Diagramm

TRP 68, TRP 69AgNi 10

10 A20 A

250 VAC, VDC

2500 VA 400 W12 VAC, 100 mA

≤ 100 mΩCA3, IEC 61810-7

1000 operat./h at rated load36000 operat./h at min load

> 107 operationssee diagram

Technische AngabenKontaktseite

Relais TRP 68 und TRP 69 sind mit einer oder zwei Anzeigen gefertigt. Eine (rote) Anzeige erscheint sich wenn das Relais in angeschprochene Position ist. Diese Anzeige erlischt wenn das Relais rückfällt. Die Relaisausführung mit der zwei Anzeigen haben neben rote Anzeige auch eine gelbe Anzeige, die bleibt verriegelt auch wenn das Relais rückfällt. Die rote Anzeige im Fenster bedeutet, dass das Relais angesprochen war. Die gelbe Anzeige in Fenster bedeutet, dass das Relais angesprochen war, aber jetz ist es im rückgefallene Position. Die gelbe Anzeige kann man mit einem Hebel auf dem oberen Teil des Relais zurückkehren.Relais TRP 68, TRP 69 haben auch eine Handprüftaste auf dem oberen Teil des Relais für manuellen schalten des Kontaktes. Diese Handprüftaste kann man mit einem Haltefeder für Befestigung des Relais dauernd aktivieren und damit des Relais dauernd schalten.

Page 23: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Coils

Coil rated voltage

Un(V)

612244860

110220230

Operative voltage rangeat 20ºC

Coil resistanceat 20ºC

DC 50Hz 60HzRn (Ω) ± 10%

28110440

174027509000

3600039000

Operate Uop≤(V)

4.89.6

19.238.44888

176184

UmaxDC ≤(V)

918367391

168336351

UmaxAC

≤(V)9.519387695

174349365

Wicklungen

0,0

0,5

1,0

1,5

2,0

2,5

-40 -30 30 40 50 60-10 0 10 20-20

Ope

rativ

e vo

ltage

rat

ioA

rbei

tssp

annu

ngsv

erhä

ltnis

Ambient temperature (°C)Umgebungstemperatur

Umax / Un (DC)

Umax / Un (AC)

Uop / UnUan / Un

5.725

100400630

200077008800

52080

320510

175070007500

Wicklungs-nenn-

spannung Un(V)

612244860

110220230

Betriebsspannungsbereich at 20ºC

Wicklungswider-stand at 20ºC

DC 50Hz 60HzRn (Ω) ± 10%

28110440

174027509000

3600039000

Ansprech Uop≤(V)

4.89.6

19.238.44888

176184

UmaxDC ≤(V)

918367391

168336351

UmaxAC

≤(V)9.519387695

174349365

5.725

100400630

200077008800

52080

320510

175070007500

Coil data at ambient temperature 20ºC

Rated power: app. 1.3 W; 2 VAOperate power: app. 0.8 W; 1.2 VAMax. coil temperature: 155 ºCThermal coil resistance: 50 K/WOperate voltage: Uop ≤ 80 % Un

Release voltage: Ure ≥ 10 % Un (DC); Ure ≥ 15 % Un (AC)Operative range: 1 (EN 61810-1)

Wicklungsangaben bei Umgebungstemp. 20ºC

Nennenleistung: ca. 1.3 W; 2 VAAnsprechleistung: ca. 0.8 W; 1.2 VAMax. Wicklungstemperatur: 155 ºCWärmewiderstand: 50 K/WAnsprechspannung: Uan ≤ 80 % Un

Rückfallspannung:: Urü ≥ 10 % Un (DC); Urü ≥ 15 % Un (AC)Arbeitsbereich: 1 (EN 61810-1)

Max. switching capacity, resistive DC loadGleichstrom-Lastgrenzkurve bei ohmscher Belastung

Sonstige DatenPrüfspannung (1 min.) Kontakt – Wicklung: ≥ 2 kVeff, 50 Hz Kontakt – Kontakt: ≥ 1 kVeff, 50 Hz zwichen Kontaktsätzen: ≥ 2 kVeff, 50 HzAnsprechzeit bei Un ≤ 15 ms Rückfallzeit: ≤ 15 msPrellzeit: ≤ 5 msIsolationswiderstand (500 VDC): > 103 MΩVibrationsfestigkeit (10-55 Hz): 3 gn

Stossfestigkeit (11 ms) zuverlässiges Schalten: 10 gn

Beschädigunsgrenze: 100 gn

Umgebunstemperatur in Betrieb: - 25 ˚C bis + 50 ˚C bei Lagerung: - 40 ˚C bis + 80 ˚CSchutzklasse: IP 50, EN 60529Isolationsgruppe: 3-250, IEC 60669-1Einbaulage: beliebig, Montageabstand 10 mmGewicht: 85 g

Operative voltage rangeBetriebsspannungsbereich

Other dataTest voltage (1 min.) Contact – coil: ≥ 2 kVrms, 50 Hz Contact – contact: ≥ 1 kVrms, 50 Hz Between contact sets: ≥ 2 kVrms, 50 HzOperate time at Un ≤ 15 ms Release time: ≤ 15 msBounce time: ≤ 5 msInsulation resistance (500 VDC): > 103 MΩVibration resistance (10-55 Hz): 3 gn

Shock resistance (11 ms) Functional: 10 gn

Destructive: 100 gn

Ambient temperature For operating: - 25 ˚C to + 50 ˚C For storage: - 40 ˚C to + 80 ˚CProtection degree: IP 50, EN 60529Insulation class: 3-250, IEC 60669-1Mounting position: as desired, relay Distance 10 mmRelay weight: 85 g

0,1

1

10

5

120 160 200 2400 40 80

Ope

ratin

g cu

rren

tSc

halts

trom

(A

)

Operating voltage (V) Schaltspannung

Page 24: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Electrical life, resistive AC loadKontaktlebensdauer bei ohmscher AC Belastung

Electrical life, resistive DC loadKontaktlebensdauer bei ohmscher DC Belastung

150 200 250 3000 50 100

Ope

ratio

nsSc

halts

piel

eSwitching power (W)Schaltleistung

350 400

10.000.000

1.000.000

100.000

10.000

10.000.000

0 0,2 1,4 1,6 1,8 20,6 0,8 1 1,20,4

Ope

ratio

nsSc

halts

piel

e

Switching power (kVA)Schaltleistung

1.000.000

100.000

10.0002,2 2,4 2,6

Ordering data for TRP 68, TRP 69

Basic designation

8 – 8 terminal pins9 – 11 terminal pins

Number of change over contacts: 1 or 2 for TRP 68 or 3 for TRP 69

1 - relay with test key2 – relay with test key and 1 flag3 – relay with test key and 2 flags4 – relay with test key and LED5 – relay with test key, LD and flag Relays with DC coil6 – relay with test key and protection diode7 – relay with test key, 1 flag and protection diode8 – relay with test key, 2 flags and protection diode9 – relay with test key, LED and protection diode0 – relay with test key, 1 flag, LED and protection diode

Rated voltage of coil; type of voltage: DC, 50 Hz, 60 Hz

TRP 6 X X XXXX ;XXXX

Bestellangaben für TRP 68, TRP 69

Typenschlüssel

8 – 8 Anschlüsse9 – 11 Anschlüsse

Anzahl der Umschaltkontakte: 1 oder 2 für TRP 68 oder 3 für TRP 69

1 - Relais mit Handprüftaste2 – Relais mit Handprüftaste und 1 Anzeige3 – Relais mit Handprüftaste und 2 Anzeige4 – Relais mit Handprüftaste und 1 Anzeige und LED5 – Relais mit Handprüftaste, Anzeige und LED Relais mit DC Wicklung6 – Relais mit Handprüftaste und Freilaufdiode7 – Relais mit Handprüftaste, 1 Anzeige und Freilaufdiode8 – Relais mit Handprüftaste, 2 Anzeige und Freilaufdiode9 – Relais mit Handprüftaste, LED und Freilaufdiode0 – Relais mit Handprüftaste, 1 Anzeige, LED und Freilaufdiode

Wicklungsnennspannung; Spannungstyp: DC, 50 Hz, 60 Hz

TRP 6 X X XXXX ;XXXX

Page 25: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Dimensions and terminals arrangementAbmessungen und Anschlussbelegung

TRP 681 TRP 682 TRP 693

Protection diodeFreilaufdiode

Page 26: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Sockel Bezeichnung Für Relais Anschlussart BefestigungTLK 1468 TRP 68 with screws on plate or rail 35 mm TLK 1469 TRP 69 with screws on plate or rail 35 mm TLK 1158 TRP 68 for soldering on plateTLK 1159 TRP 69 for soldering on plate

Socket designation For relay Connections InstallationTLK 1468 TRP 68 with screws on plate or rail 35 mm TLK 1469 TRP 69 with screws on plate or rail 35 mm TLK 1158 TRP 68 for soldering on plateTLK 1159 TRP 69 for soldering on plate

AccessoriesZubehör

SocketsSockels

Safety clipHaltefeder

14 7,5 323,6

Ø28

,5

38 47

0,8 36

55

Page 27: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Automation componentsBauteile für Automatisierung

MINIATURE POWER RELAYSMINIATUR-INDUSTRIERELAIS

TRP 312, 314, 322, 324

Page 28: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

New generation of miniature industry relays TRP 3Compact relays for industry and general purposes with 2 or 4 change-over contacts, available for AC or DC coil with plug-in, soldering or print terminals. The relays are dustproof with IP 50 ac-cording to EN 60519 with insulations parts from nonflammable material.

TRP 312, 314, 322, 324

Neue Generation des Miniatur-Industri-erelais TRP 3Kompaktes Relais für den industriellen und ge-nerellen Einsatz mit wahlweise 2, oder 4 Um-schaltkontakten.Lieferbar mit Wechselstrom- oder Gleich-stromerregung als löt-, steckbares Relais oder in Print-Ausführung.Die Relais sind staubgeschütz und entsprechen Schutzart IP 50 nach EN 60529. Die Isolierteile sind aus selbstverlöschenden Kunststoffen gefertigt.

Main characteristics- Monostable, neutral relay- DC or AC coil- High switching power- 2 or 4 change-over contacts- Print or plug-in, soldering terminals- Flag or LED switch indication- Manual test key (latchable)- Protection diode for DC types- VDE Approval, CE, UL Approval

Hauptmerkmale- Monostabile, neutrae Relais- Gleich oder Wechselstromerregung- Hohe Schalteistung- 2 oder 4 Umschaltkontakte- Print oder löt-, steckbare Anschlüsse- Mechanische oder LED Schaltstellungsanzeige- Handprüftaste (verriegelbar)- Freilaufdiode bei DC Typen- VDE Zulassung, CE, UL Zulassung

Manual test keyHandprüftaste

Pull direction for test key latchingVerriegelung durch ziehen der Prüftaste

Page 29: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Technical data

Contact dataContact form:Contact material:Rated current:Max. switch-on current:(4s, 10 % duty cycle)Max. operating voltage:Max. switching power:

Min. switching load:Contact resistance:(New relay)Max. operating frequency:

Mechanical life:Electrical life:

AgNi 10

Technische Angaben

Kontaktseite

** Umgebungstemperatur in Betrieb: -25 °C to +50 °C

** Ambient temperature: -25 °C to +50 °C

Coil data at ambient temperature 20 ºC

Rated power: app. 1 W; 1.2 VAOperate power: app. 0.6 W; 0.7 VAMax. coil temperature: 155 ºCThermal coil resistance: 65 K/WOperate voltage: Uop ≤ 80 % Un

Release voltage: Ure ≥ 10 % Un (DC); ≥ 15 % Un (AC)Operative range: 1 (EN 61810-1)

Wicklungsangaben bei Umgebungstemp. 20 ºC

Nennleistung: app. 1 W; 1.2 VAAnsprechleistung: app. 0.6 W; 0.7 VAMax. Wicklungstemperatur: 155 ºCWärmewiderstand: 65 K/WAnsprechspannung: Uan ≤ 80 % Un

Rückfallspannung: Urü ≥ 10 % Un (DC); ≥ 15 % Un (AC)Arbeitsbereich: 1 (EN 61810-1)

Technical data - Tehnische Angaben

≤ 100 mΩ(measuring method CA3, IEC 61810-7)

1200 operat./h at rated load (4 CO)1500 operat./h at rated load (2 CO)

30000 operat./h at min. load > 2 x 107 operations

see diagram

TRP 3x2x (2 CO) TRP 3x4x (4 CO)

10 A, 12 A** 5 A, 6 A**

20 A 10 A250 VAC, VDC

2500 VA 400Wsee diagram

1250 VA 200 Wsee diagram

12 VAC, 100 mA

Kontaktausführung:Kontaktmaterial:Nennstrom:Max. Einschaltstrom:(4s, 10 % ED)Max. Schaltspannung:Max. Schaltleistung:

Min. Schaltbelastung:Kontaktwiderstand:(Neuzustand)Max. Schalthäufigkeit:

Mechanische Lebensdauer:Elektrische Lebensdauer:

AgNi 10

≤ 100 mΩ(Messmethode CA3, IEC 61810-7)1200 Schaltsp./h bei Nennlast (4 U)1500 Schaltsp./h bei Nennlast (2 U)

30000 Schaltsp./h bei min. Last > 2 x 107 Schaltspiele

Siehe Diagramm

TRP 3x2x (2 CO) TRP 3x4x (4 CO)

10 A, 12 A** 5 A, 6 A**

20 A 10 A250 VAC, VDC

2500 VA 400WSiehe Diagramm

1250 VA 200 WSiehe Diagramm

12 VAC, 100 mA

Coils

Coil rated voltage

Un(V)

612244860

110220230

Operative voltage rangeat 20ºC

Coil resistanceat 20ºC

DC ACRn (Ω) ± 10%40

160650

26004000

135005300058000

1249

192785

12403880

1740018200

Operate Uop≤(V)

4.89.6

19.238.44888

176184

UmaxDC ≤(V)9.6

19.238.777.596

176350366

UmaxAC≤(V)8.3

16.733.566.983

153306320

Wicklungen

Wicklungs--nenn-

spannung Un(V)

612244860

110220230

Betriebsspannungsbereichbei 20ºC

Wicklungswider-stand bei 20ºCDC AC

Rn (Ω) ± 10%40

160650

26004000

135005300058000

1249

192785

12403880

1740018200

Ansprech Uan≤(V)

4.89.6

19.238.44888

176184

UmaxDC ≤(V)9.6

19.238.777.596

176350366

UmaxAC≤(V)8.3

16.733.566.983

153306320

Page 30: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Operative voltage rangeBetriebsspannungsbereich

Other data

Test voltage (1 min.) contact – coil: ≥ 2 kVrms, 50 Hz contact – contact: ≥ 1 kVrms, 50 Hz Between contact sets: 2 CO ≥ 2 kVrms, 50 Hz 4 CO ≥ 1 kVrms, 50 HzOperate time at Un ≤ 15 ms Release time: ≤ 14 msBounce time: ≤ 5 msInsulation resistance (500 VDC): > 103 MΩVibration resistance (10-55 Hz): 3 gn

Shock resistance (11 ms) Functional: 20 gn

Destructive: 100 gn

Ambient temperature For operating: - 25 ˚C to + 60 ˚C For storage: - 40 ˚C to + 85 ˚CProtection degree: IP 50, EN 60529Mounting position: as desired, relay distance 10 mmRelay weight: 35 g

Sonstige Daten

Prüfspannung (1 min.) Kontakt - Wicklung: ≥ 2 kVeff, 50 Hz Kontakt - Kontakt: ≥ 1 kVeff, 50 Hz zwischen Kontaktsätzen: 2 U ≥ 2 kVeff, 50 Hz 4 U ≥ 1 kVeff, 50 HzAnsprechzeit bei Un ≤ 15 ms Rückfallzeit: ≤ 14 msPrellzeit: ≤ 5 msIsolationswiderstand (500 VDC):> 103 MΩVibrationsfestigkeit (10-55 Hz): 3 gn

Stossfestigkeit (11 ms) zuverlässiges Schalten: 20 gn

Beschädigunsgrenze: 100 gn

Umgebungstemperatur in Betrieb: - 25 ˚C to + 60 ˚C bei Lagerung: - 40 ˚C to + 85 ˚CSchutzklasse: IP 50, EN 60529Einbaulage: beliebig, Montageabstand 10 mmGewicht: 35 g

0,0

0,5

1,0

1,5

2,0

2,5

-40 -30 30 40 50 60-10 0 10 20-20

Ope

rativ

e vo

ltage

rat

ioA

rbei

tssp

annu

ngsv

erhä

ltnis

Ambient temperature (°C)Umgebungstemperatur

Max. switching capacity, resistive DC loadGleichstrom-Lastgrenzkurve bei ohmscher Belastung

0,1

1

10

5

120 160 200 2400 40 80

TRP 2x2x(2CO)

TRP 2x4x(4CO)

Umax / Un (DC)

Umax / Un (AC)

Uop / UnUan / Un

Data subject to alteration Änderungen vorbehalten

Ope

ratin

g cu

rren

tSc

halts

trom

(A

)

Operating voltage (V) Schaltspannung

Page 31: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

Electrical life, resistive AC loadKontaktlebensdauer bei ohmscher AC Belastung

Electrical life, resistive DC loadKontaktlebensdauer bei ohmscher DC Belastung

Ordering data

Basic designation

1 – plug-in, soldering terminals2 – PCB terminals

NUmber of change over contacts: 2 or 4 CO

Relay version:1 – relay with test key2 – relay with test key and flag4 – relay with test key and LED5 – relay with flag, test key and LEDRelay for DC voltage6 – relay with test key and protection diode7 – relay with test key, flag and protection diode9 – relay with test key, LED and protection diode0 – relay with flag, test key, LED and protection diode

Rated voltage of coil

TRP 3 X X X XXX DC/AC

Bestellangaben

Typenschlüssel

1 – Steck-, Lötanschlüsse2 – Printanschlüsse

Anzahl der Umschaltkontakte: 2 oder 4 CO

Relaisausführungen:1 – Relais mit Handprüftaste2 – Relais mit Handprüftaste und Anzeige4 – Relais mit Handprüftaste und LED5 – Relais mit Anzeige, Handprüftaste und LEDRelais für DC Spannungen:6 – Relais mit Handprüftaste und Freilaufdiode7 – Relais mit Handprüftaste, Anzeige und Freilaufdiode 9 – Relais mit Handprüftaste, LED und Freilaufdiode0 – Relais mit Anzeige, Handprüftaste, LED und Freilaufdiode

Wicklungsnennspannung

TRP 3 X X X XXX DC/AC

10.000.000

0 0,2 1,4 1,6 1,8 20,6 0,8 1 1,20,4

Ope

ratio

nsSc

halts

piel

e

Switching power (kVA)Schaltleistung

150 200 250 3000 50 100

TRP 2x3x(2CO)

TRP 3x4x(4CO)

Ope

ratio

nsSc

halts

piel

e

Switching power (W)Schaltleistung

1.000.000

100.000

10.0002,2 2,4 2,6

TRP 3x2x (2CO)

TRP 3x4x (4CO)

TRP 3x4x (4CO)cos f = 0,6

TRP 2x3x (2CO)cos f = 0,6

350 400

10.000.000

1.000.000

100.000

10.000

Page 32: Automation components Bauteile für Automatisierung · Automation components Bauteile für Automatisierung POWER RELAYS INDUSTRIESRELAIS PR 45, 46 TRP 614, 624, 66, 67 TRP 651, 652

2x6,

35

4,1

3x4,413,2

Ø1,5

3,83,8

2x6,

35

4,1

4,2

4,2

Ø1,5

1 4

5 8

9 12

13 14

1 4

5 8

9 12

13 14

2 3

6 7

10 11

Dimensions and terminals arrangementAbmessungen und Anschlussbelegung

Plug-in, soldering terminalsSteck-, Lötanschlüsse

355,

5 0,528

2,2

21

2,0

21

TRP 312 TRP 314

PCB terminalsPrintanschlüsse

TRP 322 TRP 324

353,

5 0,528

1,0

21

1,0

21

iskra stikalni elementi d.d., Predstruge 29, 1312 Videm - Dobrepolje, Slovenijatel.:+386 1 7867 800, fax:+386 1 7807 619, www.iskra-se.si, [email protected]