automotive appendix
DESCRIPTION
okTRANSCRIPT
APPENDIX A
a.1.2. Assessment Area
AUTOMOTIVE SERVICING NC IITRAINING REGULATIONSFOR
AUTOMOTIVE SERVICING NC IIAUTOMOTIVE/LAND TRANSPORT SECTOR
TECHNICAL EDUCATION AND SKILLS DEVELOPMENT AUTHORITYEast Service Road, South Superhighway, Taguig City, Metro Manila
TABLE OF CONTENTS
CONSTRUCTION INDUSTRY - ELECTRICAL SUB-SECTOR
ELECTRICAL INSTALLATION & MAINTENANCE NC II
Page No.
SECTION 1 AUTOMOTIVE SERVICING NC II QUALIFICATION1
SECTION 2 COMPETENCY STANDARDS2 92
Basic Competencies2 - 13
Common Competencies14 - 53
Core Competencies54 - 92
SECTION 3 TRAINING STANDARDS93 101
3.1 Curriculum Design93 98
3.2 Training Delivery99
3.3 Trainee Entry Requirements100
3.4 List of Tools, Equipment and Materials100
3.5 Training Facilities101
3.6 Trainers' Qualifications101
3.7 Institutional Assessment101
SECTION 4 NATIONAL ASSESSMENT AND CERTIFICATION ARRANGEMENTS102
COMPETENCY MAP103
DEFINITION OF TERMS104 105
ACKNOWLEDGEMENTS106 - 107
3.2 TRAINING FACILITIESAUTOMOTIVE SERVICING NC II
The automotive workshop must be made of reinforced concrete or steel structure. The size must be suited on the requirements of the competencies. The class size of 25 students/trainees is reserved for the lecture room and the practical demonstration area for carrying out servicing of minor automotive parts. Most of the learning activities such as on-vehicle servicing are performed in the workshop.SPACE REQUIREMENTSIZE IN METERSAREA IN SQ. METERSTOTAL AREA IN SQ. METERS
Building (permanent)12.00 x 32.00-384.00
Student/Trainee Working Space2.50 x 2.50 per student/trainee6.25 per student156.25
Contextual Learning Laboratory4.00 x 5.0020.0020.00
Lecture Room4.00 x 7.0028.0028.00
Learning Resource Center4.00 x 5.0020.0020.00
Facilities/Equipment /Circulation Area--159.75
a.2.1 Assessment room or LaboratoriesAPPENDIX BA.2 Lighting And Ventilation
*Based on Accreditation of Assessment Center Self-Assessment Check List, TSU-CT is within the minimum TESDA requirement lighted at an average of 30-40 foot-candle with minimal tolerance dark spot.
a.2.3 Blowers/ Fans
a.3.1. Store Room APPENDIX CA.3 Auxiliary Room
*Based on TESDA Accreditation of Assessment Center Self-Assessment Check List, the tools are kept in a customize cabinets.
a.3.2. Room for Performance Assessment *Based on TESDA Accreditation of Assessment Center Self-Assessment Check List, TSU-CT can accommodate at least 10 candidates/ batch
a.3.3. Chairs and Tables *Based on TESDA Accreditation of Assessment Center Self-Assessment Check List, TSU-CT is provided with chairs, tables, chalkboard/whiteboards, and other needed furniture as needed in the laboratory.
a.3.3. Comfort Rooms
*Based on TESDA Accreditation of Assessment Center Self-Assessment Check List, TSU-CT is neat and orderly maintained by the universitys General Services Office (GSO).
A.4 ASSESSMENT EQUIPMENT, HAND TOOLS, SUPPLIES MATERIALS
LABORATORY UPGRADING MODERNIZATION
TOOLS
No. UnitItem Specification Unit CostQTYTotal Amount
1setsBox wrench95043800
2setsSocket wrench3500414000
3setsPliers45041800
4setsScrew driver85043400
5setsWire stripper120044800
6setsMechanics hammer2204880
7pcsApron7502015000
8pcsGoggle150203000
9pcsGlove290205800
10sets Torque wrench6500426000
11sets Feeler gauge2004800
12setsBattery tester5000420000
13setsHydrometer30041200
14setsDial gauge9000436000
15setsBore gauge4000416000
16setsMicrometer caliper6000424000
Total 176480
EQUIPMENT
No. UnitItem Specification Unit CostQTYTotal Amount
1units Motor Vehicle450,0002900000
2units Engine75,0002150000
3units Hydraulic jack/lift3,50027000
4units Growler tester4,800419200
5units Ignition timing light4,500418000
6units Tachometer2,900411600
7units Differential and front axle3,300413200
8units Multimeter3,900415600
Total 1134600
Materials
No. UnitItem Specification Unit CostQTYTotal Amount
1 ltrs Engine oil2905014500
2 ltrs Grease2005010000
3 ltrs Sealant /adhesive250102500
4 ltrs Hydraulic oils/gear oil220102200
5 ltrs Automatic transmission fluid2405012000
6pcs Wheel wedges500105000
7pcs Test lamp600106000
Total 52200
LABORATORY UPGRADING MODERNIZATION
Equipment 176,480
Tools 1,134,600
Material52,200
Total1,363,280
a.5.1 Medicine CabinetAPPENDIX DA.5 Safety Provisions
A first-aid cabinet for antidotes and neutralizing solution are present on the laboratory
a.5.2 Open Floor SpacesAre appropriately grouped to provide ease of movement
a.5.4. Fire Extinguisher
a.5.4. Equipment LayoutTraining equipment are arrange according to sequence of operation
a.5.6. Color Coded Buttons
Industrial training equipment emergency buttons are well color coded and ergonomically installed for safety.
35