auxiliary valve prs6 - phtruck.com · 3 parker hannifin mobile controls division borås, sweden...

32
Auxiliary Valve PRS6 Pressure Reducing Valve Catalogue HY17-8541/UK September 2005

Upload: tranthien

Post on 13-Apr-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Auxiliary Valve PRS6Pressure Reducing Valve

Catalogue HY17-8541/UKSeptember 2005

2 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesPRS6

Subject to alteration without prior notice. The curves and diagrams in this catalogue are typical examples only. While the contents of the catalogue are updated continuously, the validity of the information given should always be confirmed. For more detailed information, please contact Parker.

Catalogue HY17-8541/UK

General

3 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesPRS6

PRS6

ApplicationsThe PRS6 is a three-way pressure reducing valve that has been developed to give reduced pressure in a particular part of a hydraulic system. The valve maintains the secondary pressure setting constantly, regardless of pressure variations on the primary side. A common application is in pilot circuits in hydraulic and electro-hydraulic servo systems, where the pres-sure is taken from the main system and reduced by the PRS6 to a level that is suitable for the pilot circuit.

Construction and functionThe valve housing is manufactured from continuously-cast grey iron and contains a precision-ground spool. To keep oil consumption at a low level, the spool has positive overlapping. This gives a certain difference in secondary pressure at different flow take-off rates. For this reason, the valve setting should be made with the desired flow rate passing through the valve. When a high primary pressure is reduced to a low secondary pressure (pressure differential over 150 bar), pres-sure reduction should be effected in two stages using two PRS6 valves connected in series.

Advantages• Compact and easy to install.

• Easy to adjust within respective pres-sure range.

• Can be factory-set and sealed to prevent unauthorized pressure changing.

• Highly suited for use as a reducing valve in pilot circuits where the pilot pressure is taken from the main circuit.

• Withstands high pressure shocks in the tank connection.

Optional equipmentNumerous other options are available for the PRS6. For further information, please contact your Parker representative.

• Spool for two-way function.

• Hand wheel for easy changing of pres-sure setting.

• Flanged version of PRS6 for flanging directly to, e.g. a valve block.

• Adjuster device for external control of secondary pressure by means of a pilot pressure.

Catalogue HY17-8541/UK

General Information

4 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesPRS6

100

120

140

160

180

200

20

40

60

80

00 5 352510 2015 30

100

120

140

160

180

200

20

40

60

80

00 5 352510 2015 30

Pressure limiting characteristic for PRS6

∆ p (bar)

q (l/min)

Functional symbol for PRS6

Pressure reducing characteristic for PRS6

∆ p (bar)

q (l/min)

Possible pressure setting ranges(applicable range will depend on pressure setting you specify)Secondary pressure4-10 bar11-20 bar21-30 bar31-45 bar46-150 bar150 bar to any value below 250 bar.

Primary pressureMax. 250 bar

Tank pressureMax. 250 bar in pressure shocks.

Recommended reduction(differential between primary and secondary pressure)Max. 150 bar

Pressure-setting flow ratePressure should be set with desired flow rate (l/min) flowing through the valve.

Recommended flow rateMax. 30 l/min depending on secondary pressure. See diagram.

ConnectionsAll connections are available in two versions:- G1/4 (BSP pipe thread) for flat seal (type Tredo) according to ISO 228/1.- 9/16-18 UNF-2B for O-ring seal according to SAE J1926/1.

LeakageConnection P to connection T max. 0.15 l/min at pressure differential of 100 bar and oil viscosity of 30 mm/s2.

WeightApprox. 1.0 kg

Hydraulic fluidsBest performance is obtained using mineral-base oil of high quality and cleanness in the hydraulic system.

HLP hydraulic fluids (DIN 51524), automatic-gearbox oil type A and API CD engine oils can be used. If in doubt, please contact Parker for further information.

For best function, oil viscosity should be between 15 and 45 mm/s2 (cSt).

FiltrationFiltration should be arranged so that Target Contamination Class 18/16/13 according to ISO 4406 is not exceeded.

TemperatureTemperature range, fluid:-20 °C to + 70 °CTemperature range, ambient:-40 °C to +70 °CTemperature-shock resistance: max. 100 °C/second

GeneralTechnical data in this catalogue is applicable using mineral base oil according to DIN 51524 at a viscosity of 30 mm2/s and temperature of 50 °C.

PRS-2

P T

S

Catalogue HY17-8541/UK

Technical Data

5 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesPRS6

PRS-1

15

39

32

25

50

9

9

15

30

2724

92A

30 m

ax

S

T

P

(1.5

4)

(0.59)

(1.97)

(0.98)

(1.26) (0.35)

(0.3

5)

(1.18)

(0.59)

(1.0

6)(0

.94)

(3.6

2)

(1.1

8 m

ax)

Fixing holes Ø6,5 (2x)

(Ø0,26 2x)

A = 15 at 4 - 45 barA = 44 at 46 - 250 bar

Catalogue HY17-8541/UK

Dimensions

6 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesPRS6

Please use ordering-code system in chart below to specify your PRS6 valve.The ordering numbers in the table below apply to certain standard settings (please cross-reference with ordering-code system chart) and can be used directly when ordering.

Code Ordering numberPRS6G-10-01-O 8234 8906 35PRS6G-20-01-O 8234 8906 25PRS6G-30-01-O 8234 8906 33PRS6G-40-01-O 8234 8906 34PRS6G-100-01-O 8234 8907 08

Code Sealing O Not sealed P Valve sealed with sealing wire and seal

Ordering code

Code Secondary pressure Valve is delivered preset at specified secondary pressure (pressure range 4 bar to marginally below 250 bar)

Code Pressure-setting flow rate Secondary pressure is set while desired flow rate (l/min) is passing through valve. Flow range: 0 - 30 l/min

Code Connection G G1/4 (BSP pipe) thread U 9/16-18 UNF-2B thread

Catalogue HY17-8541/UK

Ordering

PRS6 — —

Secondary pressure

Pressure setting

Sealing

Connection

7 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesPRS6

Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application, including consequences of any failure, and review the information concerning the product or sys-tem in the current product catalogue. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met.

The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.

WARNING!

Catalogue HY17-8541/UK

Parker Hannifin is the world’s premier supplier of motion and control systems and solutions, with sales and manufacturing facilities throughout the world. For product information and details of your nearest Parker sales office, visit us at www.parker.com or call free on 00800 2727 5374.

Hydraulics GroupSales Offices

Austria Wiener Neustadt Tel: +43 (0)2622 23501Fax: +43 (0)2622 66212

Belgium Nivelles Tel: +32 (0)67 280 900 Fax: +32 (0)67 280 999

Czech Republic Klecany Tel: +420 284 083 111 Fax: +420 284 083 112

Denmark Ballerup Tel: +45 4356 0400 Fax: +45 4373 8431

Finland Vantaa Tel: +358 (0)9 4767 31 Fax: +358 (0)9 4767 3200

France Contamine-sur-Arve Tel: +33 (0)450 25 80 25 Fax: +33 (0)450 03 67 37

GermanyKaarst Tel: +49 (0)2131 4016 0 Fax: +49 (0)2131 4016 9199

Hungary Budapest Tel: +36 (06)1 220 4155 Fax: +36 (06)1 422 1525

Ireland Dublin Tel: +353 (0)1 293 9999 Fax: +353 (0)1 293 9900

Italy Corsico (MI) Tel: +39 02 45 19 21 Fax: +39 02 4 47 93 40

The Netherlands Oldenzaal Tel: +31 (0)541 585000 Fax: +31 (0)541 585459

Norway Ski Tel: +47 64 91 10 00 Fax: +47 64 91 10 90

Poland Warsaw Tel: +48 (0)22 863 49 42 Fax: +48 (0)22 863 49 44

Portugal Leca da Palmeira Tel: +351 22 9997 360 Fax: +351 22 9961 527

Slovakia Ref. Czech Republic Spain Madrid Tel: +34 91 675 73 00 Fax: +34 91 675 77 11

Sweden Spånga Tel: +46 (0)8 597 950 00 Fax: +46 (0)8 597 951 10

TurkeyMerter/IstanbulTel.: +90 212 482 91 06 or 07Fax: +90 212 482 91 10

United Kingdom Warwick Tel: +44 (0)1926 317 878 Fax: +44 (0)1926 317 855

InternationalEurope

Catalogue HY17-8541/UKPDF 09/05

© Copyright 2005 Parker Hannifin CorporationAll rights reserved.

Australia Castle Hill Tel: +61 (0)2-9634 7777 Fax: +61 (0)2-9899 6184

Canada Milton, Ontario Tel: +1 905-693-3000 Fax: +1 905-876-0788

China Beijing Tel: +86 10 6561 0520 Fax: +86 10 6561 0526

Asia Pacific GroupHong Kong, Kowloon Tel: +852 2428 8008 Fax: +852 2425 6896

IndiaMumbai Tel: +91 22 7907081 Fax: +91 22 7907080

JapanTokyo Tel: +(81) 3 6408 3900 Fax: +(81) 3 5449 7201

Latin America GroupBrazilTel: +55 12 3954-5100 Fax: +55 12 3954-5266

South Africa Kempton Park Tel: +27 (0)11-961 0700 Fax: +27 (0)11-392 7213

USACleveland (industrial) Tel: +1 216-896-3000 Fax: +1 216-896-4031Lincolnshire (mobile) Tel: +1 847-821-1500 Fax: +1 847-821-7600

Auxiliary Valve QDS6Sequence Valve, 3-way

Catalogue HY17-8542/UKSeptember 2005

2 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesQDS6

Catalogue HY17-8542/UK

Subject to alteration without prior notice. The curves and diagrams in this catalogue are typical examples only. While the contents of the catalogue are updated continuously, the validity of the information given should always be confirmed. For more detailed information, please contact Parker.

General

3 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesQDS6

Catalogue HY17-8542/UK

QDS6

ApplicationsThe QDS6 sequence valve is designed to open or close a hydraulic pilot signal (that comes from an external source) when it reaches a predetermined pressure level. Common applications of the valve are in pilot logic circuits and sequence-control sub-circuits. One example of use is as a means of load-moment limitation (overload protection) in the lifting func-tions of mobile cranes, in conjunction with hydraulic remote control. In such cases, the QDS6 is used to break the pilot signal between the control valve and the directional valve when the signal pressure reaches a predetermined value set on the QDS6.

Construction and functionThe QDS6 is a three-way, pilot-operated valve. Its directional function is normally open or normally closed.

The valve housing is manufactured from continuously-cast grey iron and contains a precision-ground spool and pilot section.

When the pilot signal exceeds the preset switching pressure, the spool changes position, thus blocking P and connecting S with T. Alternatively, T is blocked and S connected with P (see figure on page 4). The spool is positively overlapped, i.e. it closes the one connec-tion before opening the other. The pilot section can be drained either internally or externally. Pilot sections with external drainage can be fed with an external pres-sure in the drainage connection to obtain a higher switching pressure than the one preset.

Advantages• Compact - easy to install.

• Several pressure ranges available - enables high setting precision.

• Easy to adjust pressure within speci-fied pressure range - facilitates fine tuning.

• Can be factory-set and sealed - prevents unauthorized pressure changing.

• Withstands high pressure shocks in the tank connection - gives long service life in systems with high intermittent tank pressure.

• Simple design - gives great reliability.

Optional equipmentNumerous other options are available for the QDS6. For further information, please contact your Parker representative.

• Hand wheel for easy changing of pres-sure setting.

• Flanged version of QDS6 for flanging directly to, e.g. a valve block.

General Information

4 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesQDS6

Catalogue HY17-8542/UK

Pressure drop for QDS61 = Pressure drop P-S for spool A and B2 = Pressure drop S-T for spool C and E3 = Pressure drop P-S for spool C and E4 = Pressure drop S-T for spool A and B

∆ p (bar)

q (l/min)

Functional symbols for QDS6

Possible pressure setting ranges (applicable range will depend on pressure setting you specify)

Switching pressure4-10 bar11-20 bar21-30 bar31-45 bar46-150 bar150-250 bar

Working pressureMax. 250 bar

Tank pressureMax. 250 bar in pressure shocks.

Recommended flow rateMax. 20 l/min

ConnectionsAll connections are available in two versions:- G1/4 (BSP pipe thread) for flat seal (type Tredo) according to ISO 228/1.- 9/16-18 UNF-2B for O-ring seal according to SAE J1926/1.

LeakageAt pressure differential of 100 bar and viscosity of 30 mm/s2:P to S max. 12 cm3/minS to T max. 12 cm3/minP to X max. 5 cm3/min

WeightApprox. 1.0 kg

Hydraulic fluidsBest performance is obtained using mineral-base oil of high quality and cleanness in the hydraulic system. HLP hydraulic fluids (DIN 51524), automatic-gearbox oil type A and API CD engine oils can be used. If in doubt, please contact Parker for further information.

For best function, oil viscosity should be between 15 and 45 mm/s2 (cSt).

FiltrationFiltration should be arranged so that Target Contamination Class 18/16/13 according to ISO 4406 is not exceeded.

TemperatureTemperature range, fluid:-20 °C to + 70 °CTemperature range, ambient:-40 °C to +70 °CTemperature-shock resistance: max. 100 °C/second

GeneralTechnical data in this catalogue is applicable using mineral base oil according to DIN 51524 at a viscosity of 30 mm2/s and temperature of 50 °C.

25

30

35

5

10

15

20

00 5 352510 2015 30

1234

QDS-2

D

D

S

S

S

S

P

P

P

P

T

T

T

T

X

X

X

X

Spool A

Spool B

Spool C

Spool E

For damped signal only

(Positively overlapped spool)

Technical Data

5 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesQDS6

Catalogue HY17-8542/UK

Fixing holes ∅ 6.5 (2x)

(Ø0.26 2x)A = 15 at 4 - 45 barA = 44 at 46 - 250 bar

QDS-1

15

3939

50

25

32 9

9

30

15

2724

92A

30 m

ax

S

T

P

X

D

(0.59)

(1.5

4)(1

.54)

(1.97)

(0.98)

(1.26) (0.35)

(0.3

5)

(1.18)

(0.59)

(1.0

6)(0

.94)

(3.6

2)

(1.1

8 m

ax)

Fitted for spools B and E only

Fitted for damped signal only

Dimensions

6 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesQDS6

Catalogue HY17-8542/UK

When ordering your QDS6 sequence valve, please make use of the ordering-code system as per the example given in the chart below. For certain standard valve settings, however, there are direct ordering numbers, which are given in the table below.

Code Ordering numberQDS6G-05-B-O-O 8234 8905 75QDS6G-15-E-O-O 8234-8905 92QDS6G-25-B-O-O 8234 8905 91QDS6G-100-B-O-O 8234 8905 83QDS6G-250-E-O-O 8234 8905 88

Ordering code

Code Switching pressure Valve is delivered preset at specified switching pressure. Pressure range 4 - 250 bar.

Code Connection G G1/4 (BSP pipe) thread U 9/16-18 UNF-2B thread

Code Damping of signal X O Not damped

D Damped

Code Spool function A P to S normally open. External drainage of pilot section.

B P to S normally open. Internal drainage of pilot section.

C P to S normally closed. External drainage of pilot section.

E P to S normally closed. Internal drainage of pilot section.

Code Sealing O Not sealed P Valve sealed with sealing wire and seal

QDS6 — —

Switching pressure

Spool function

Damping of signal X

Sealing

Connection

— —

Ordering

7 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesQDS6

Catalogue HY17-8542/UK

Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application, including consequences of any failure, and review the information concerning the product or sys-tem in the current product catalogue. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met.

The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.

WARNING!

Hydraulics GroupSales Offices

Catalogue HY17-8542/UKPDF 09/05

© Copyright 2005 Parker Hannifin CorporationAll rights reserved.

Parker Hannifin is the world’s premier supplier of motion and control systems and solutions, with sales and manufacturing facilities throughout the world. For product information and details of your nearest Parker sales office, visit us at www.parker.com or call free on 00800 2727 5374.

Austria Wiener Neustadt Tel: +43 (0)2622 23501Fax: +43 (0)2622 66212

Belgium Nivelles Tel: +32 (0)67 280 900 Fax: +32 (0)67 280 999

Czech Republic Klecany Tel: +420 284 083 111 Fax: +420 284 083 112

Denmark Ballerup Tel: +45 4356 0400 Fax: +45 4373 8431

Finland Vantaa Tel: +358 (0)9 4767 31 Fax: +358 (0)9 4767 3200

France Contamine-sur-Arve Tel: +33 (0)450 25 80 25 Fax: +33 (0)450 03 67 37

GermanyKaarst Tel: +49 (0)2131 4016 0 Fax: +49 (0)2131 4016 9199

Hungary Budapest Tel: +36 (06)1 220 4155 Fax: +36 (06)1 422 1525

Ireland Dublin Tel: +353 (0)1 293 9999 Fax: +353 (0)1 293 9900

Italy Corsico (MI) Tel: +39 02 45 19 21 Fax: +39 02 4 47 93 40

The Netherlands Oldenzaal Tel: +31 (0)541 585000 Fax: +31 (0)541 585459

Norway Ski Tel: +47 64 91 10 00 Fax: +47 64 91 10 90

Poland Warsaw Tel: +48 (0)22 863 49 42 Fax: +48 (0)22 863 49 44

Portugal Leca da Palmeira Tel: +351 22 9997 360 Fax: +351 22 9961 527

Slovakia Ref. Czech Republic Spain Madrid Tel: +34 91 675 73 00 Fax: +34 91 675 77 11

Sweden Spånga Tel: +46 (0)8 597 950 00 Fax: +46 (0)8 597 951 10

TurkeyMerter/IstanbulTel.: +90 212 482 91 06 or 07Fax: +90 212 482 91 10

United Kingdom Warwick Tel: +44 (0)1926 317 878 Fax: +44 (0)1926 317 855

InternationalEurope

Australia Castle Hill Tel: +61 (0)2-9634 7777 Fax: +61 (0)2-9899 6184

Canada Milton, Ontario Tel: +1 905-693-3000 Fax: +1 905-876-0788

China Beijing Tel: +86 10 6561 0520 Fax: +86 10 6561 0526

Asia Pacific GroupHong Kong, Kowloon Tel: +852 2428 8008 Fax: +852 2425 6896

IndiaMumbai Tel: +91 22 7907081 Fax: +91 22 7907080

JapanTokyo Tel: +(81) 3 6408 3900 Fax: +(81) 3 5449 7201

Latin America GroupBrazilTel: +55 12 3954-5100 Fax: +55 12 3954-5266

South Africa Kempton Park Tel: +27 (0)11-961 0700 Fax: +27 (0)11-392 7213

USACleveland (industrial) Tel: +1 216-896-3000 Fax: +1 216-896-4031Lincolnshire (mobile) Tel: +1 847-821-1500 Fax: +1 847-821-7600

Auxiliary ValvesVV6Shuttle Valve

Catalogue HY17-8602/UKSeptember, 2005

2 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesVV6

Catalogue HY17-8602/UK

ApplicationsThe VV6 enables two flows in a hydraulic system to be directed alternately into a common service line. The flow with the highest pressure takes priority.)

The valve is intended for use in load-signal systems and in pilot-operated systems that have two alternate operator’s stations.

Design and functionThe valve consists of a valve housing, a poppet and two valve seats. It has two inlets and one outlet.

The pressure differential that arises when oil flows through the valve pushes the poppet to the opposite inlet and blocks it, at the same time as the outlet is opened. The valve can only be used with the direction of flow going from the inlets to the outlet.

Technical dataWorking pressureMax. 250 bar

Recommended flow rateMax. 20 l/min

ConnectionsAll connections are available in two versions:G-version (BSP pipe thread) for flat seal (type Tredo) according to ISO 228/1 and UN version for O-ring seal according to SAE J1926/1.

WeightApprox. 0.4 kg

Hydraulic fluidsBest performance is obtained using mineral-base oil of high quality and clean-ness in the hydraulic system.

HLP hydraulic fluids (DIN 51524), automatic-gearbox oil type A and API CD engine oils can be used.

Synthetic, fire-resistant and envi-ronmentally friendly fluids can also be used. Please contact Parker for further information.

For best function, fluid viscosity should be between 15 and 45 mm2/s.

FiltrationFiltration should be arranged so that Target Contamination Class 20/18/14 according to ISO 4406 is not exceeded.

TemperatureTemperature range (fluid):-20 °C to +80 °CTemperature range (ambient):-40 °C to +60 °CTemperature change:Max. 100 °C/s

GeneralThe data given above is applicable at an oil temperature of 50 °C and viscosity of 30 mm2/s using mineral-base oil according to DIN 51524.

Advantages of VV6 shuttle valve

• Small dimensions, easy to install

• Rapid switching

The curves used in this publication are typical curves only.The manufacturer reserves the right to make modifications without prior notice.

General Information

3 Parker HannifinMobile Controls DivisionBorås, Sweden

Auxiliary ValvesVV6

Catalogue HY17-8602/UK

∆ p (bar)

q (l/min)

12

2

4

6

8

10

00 5 10 15 20 25 30

Hydraulic symbol for VV6Pressure-drop characteristics for VV6

∅6,5

27

IN IN

OUT

46

92

15

3020

30

5,5

OrderingThe VV6 can be ordered using a designation code or ordering number.

Thread Designation Ordering No.G1/4 VV6G 8234 8902 70UNF-9/16-18-2B VV6U 8234 8902 71

Technical Information

Dimensional drawing, VV6

Hydraulics GroupSales Offices

Catalogue HY17-8602/UKPDF 09/05

© Copyright 2005Parker Hannifin CorporationAll rights reserved.

Parker Hannifin is the world’s premier supplier of motion and control systems and solutions, with sales and manufacturing facilities throughout the world. For product information and details of your nearest Parker sales office, visit us at www.parker.com or call free on 00800 2727 5374.

Austria Wiener Neustadt Tel: +43 (0)2622 23501Fax: +43 (0)2622 66212

Belgium Nivelles Tel: +32 (0)67 280 900 Fax: +32 (0)67 280 999

Czech Republic Klecany Tel: +420 284 083 111 Fax: +420 284 083 112

Denmark Ballerup Tel: +45 4356 0400 Fax: +45 4373 8431

Finland Vantaa Tel: +358 (0)9 4767 31 Fax: +358 (0)9 4767 3200

France Contamine-sur-Arve Tel: +33 (0)450 25 80 25 Fax: +33 (0)450 03 67 37

GermanyKaarst Tel: +49 (0)2131 4016 0 Fax: +49 (0)2131 4016 9199

Hungary Budapest Tel: +36 (06)1 220 4155 Fax: +36 (06)1 422 1525

Ireland Dublin Tel: +353 (0)1 293 9999 Fax: +353 (0)1 293 9900

Italy Corsico (MI) Tel: +39 02 45 19 21 Fax: +39 02 4 47 93 40

The Netherlands Oldenzaal Tel: +31 (0)541 585000 Fax: +31 (0)541 585459

Norway Ski Tel: +47 64 91 10 00 Fax: +47 64 91 10 90

Poland Warsaw Tel: +48 (0)22 863 49 42 Fax: +48 (0)22 863 49 44

Portugal Leca da Palmeira Tel: +351 22 9997 360 Fax: +351 22 9961 527

Slovakia Ref. Czech Republic Spain Madrid Tel: +34 91 675 73 00 Fax: +34 91 675 77 11

Sweden Spånga Tel: +46 (0)8 597 950 00 Fax: +46 (0)8 597 951 10

TurkeyMerter/IstanbulTel.: +90 212 482 91 06 or 07Fax: +90 212 482 91 10

United Kingdom Warwick Tel: +44 (0)1926 317 878 Fax: +44 (0)1926 317 855

InternationalEurope

Australia Castle Hill Tel: +61 (0)2-9634 7777 Fax: +61 (0)2-9899 6184

Canada Milton, Ontario Tel: +1 905-693-3000 Fax: +1 905-876-0788

China Beijing Tel: +86 10 6561 0520 Fax: +86 10 6561 0526

Asia Pacific GroupHong Kong, Kowloon Tel: +852 2428 8008 Fax: +852 2425 6896

IndiaMumbai Tel: +91 22 7907081 Fax: +91 22 7907080

JapanTokyo Tel: +(81) 3 6408 3900 Fax: +(81) 3 5449 7201

Latin America GroupBrazilTel: +55 12 3954-5100 Fax: +55 12 3954-5266

South Africa Kempton Park Tel: +27 (0)11-961 0700 Fax: +27 (0)11-392 7213

USACleveland (industrial) Tel: +1 216-896-3000 Fax: +1 216-896-4031Lincolnshire (mobile) Tel: +1 847-821-1500 Fax: +1 847-821-7600

Auxiliary valvesPLC seriesDirect-acting pressure relief valves

Catalogue HY17-8702/UKAugust 2005

2 Parker Hannifin ABMobile Controls DivisionBoras, Sweden

Pressure relief valvesPLC series

List of contents PageGeneral Information ....................................................................................................... 3PLC053 .......................................................................................................................... 4Single housing for PLC053 ............................................................................................ 5PLC082 .......................................................................................................................... 6Single housing for PLC082 ............................................................................................ 7Double housing for PLC082 .......................................................................................... 8PLC182 .......................................................................................................................... 9PLC280 ........................................................................................................................ 10Ordering ....................................................................................................................... 11

Catalogue HY17-8702/UK

Contents

Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBEDHEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provideproduct and/or system options for further investigation by users having technical expertise. It is important that you analyze allaspects of your application, including consequences of any failure, and review the information concerning the product orsystem in the current product catalogue. Due to the variety of operating conditions and applications for these products orsystems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products andsystems and assuring that all performance, safety and warning requirements of the application are met.

The products described herein, including without limitation, product features, specifications, designs, availability and pricing, aresubject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.

WARNING!

3 Parker Hannifin ABMobile Controls DivisionBoras, Sweden

Pressure relief valvesPLC series

The PLC series auxiliary valves are direct-acting, factory-set pressure relief valves ofthe cartridge type that can be suppliedwith or without a threaded plug. They canalso be supplied with housings to facilitatein-line installation.

PLC valves are intended primarily toact as combined pressure-relief and anti-cavitation valves - otherwise known as portrelief valves - in the service ports of ourdirectional valves. However, they can alsobe used to advantage in other situationswhere pressure relief valves in this sizerange are required. Indeed, PLC cartridgevalves are purchased in great quantities byseveral of the world’s leading pump andtransmission manufacturers.

Construction and functionPLC pressure relief valves are made ofhigh-strength steel and consist of a seat,poppet, spring and nut. After the pressuresetting has been made, the damper nut islocked against the poppet by welding, inorder to prevent the factory-set openingvalue from changing. When the cartridge issupplied with a plug, a spring is includedto enable the cartridge to function as ananti-cavitation valve. An anti-cavitation val-ve is essentially a check valve that enablesoil to be sucked from the tank line in orderto prevent cavitation in a consumer. Theplug is fitted with an O-ring of nitrile rub-ber.

Poppets without a pressure relief func-tion are also available. They are usedwhen only a ‘check valve’ is required toperform an anti-cavitation function.

Technical dataFlow capacityThe flow capacities of the respective PLCvalves are dependent on the extent ofpressure increment that can be accepted,

and are illustrated in the typical graphsthat begin overleaf. The nominal flowcapacities, however, are as follows:

PLC053 50 l/minPLC082 80 l/minPLC182 180 l/minPLC280 280 l/min

Pressure-setting flowAs standard, the desired pressure is setwith a flow of 20 l/min passing through thepressure relief valve. The exception is thePLC053, for which the pressure setting ismade with a flow of 10 l/min passingthrough the valve.

WeightsPLC053 0,06 kgPLC082 0,11 kgPLC182 0,165 kgPLC280 0,39 kg

The PLC valves are all supplied with athreaded plug.

Housing for PLC082 cartridge(inclusive of cartridge) 1,6 kgHousing for two PLC082 cartridges(inclusive of cartridges) 2,8 kg

Hydraulic fluidsBest performance is obtained using mine-ral-base oil of high quality and cleannessin the hydraulic system.

Hydraulic fluids of type HLP (DIN51524), oil for automatic gearboxes TypeA and engine oil type API CD can beused.

Synthetic, fire-resistant and environ-mentally friendly oils can also be used. Ifin doubt about the suitability of an oil,please contact your nearest Parker repre-sentative for advice.

For best function, oil viscosity shouldbe between 15 and 45 mm2/s (cSt).

PLC053 PLC082 PLC182 PLC280

FiltrationFiltration should be arranged so that Tar-get Contamination Class 20/18/14 accor-ding to ISO 4406 is not exceeded.

TemperatureTemperature range, fluid:-20 oC to +90 oCTemperature range, ambient:-40 oC to +60 oCTemperature shock resistance:max. 100 oC/second

GeneralThe data given in this catalogue is appli-cable at an oil temperature of 50 oC andviscosity of 30 mm2/s (cSt) using mineral-base oil complying with DIN 51524, whenthe cartridge valve is installed in a mastermanifold.

Features and benefits• Small dimensions - easy to install

• Single unit - facilitates installation

• Very tight - no unnecessary leakagelosses

• Good characteristic – small pressurechange between different flows

• Good opening and closing characteris-tics – distinct opening and closing

• Low hysteresis – good precision inpressure maintenance

• Fast acting – reacts quickly to pressuresurges

• Setting locked by welding – preventsundesirable changing of pressure set-ting

Catalogue HY17-8702/UK

General Information

4 Parker Hannifin ABMobile Controls DivisionBoras, Sweden

Pressure relief valvesPLC053 series

Catalogue HY17-8702/UK

Technical Information

10 5020 6030 40

10

00

20

30

R0,1-0,3

R1±0,2

2,7±

0,2

0,5±

0,1

(32,

5±0,

1)

32,5

±0,

1

R0,5 max

R0,6 max

R0,2 max

2,5

2,5

15°±1°

40°±1° 45°±5°

0,05 A

A

0,1 A

0,05 A

15 m

in

23+

0,2

-0,8

M18x1,5-6H

Ø20,3 0-0,1

Ø13,8 +0,0430

Ø0,

1

4

4

Ø10+0,04-0,02

4

4

0,05 A

A

10 5020 6030 40

100

00

200

300

400

Diagram for PLC053 pressure relief valve

∆p (bar) Pressure override characteristic

q (l/min)∆p (bar) Anti-cavitation characteristic

Seat embossed with Ø13 mm class III steel ballImpact energy 9±2 NmStated dimensions apply before embossing

With

in40

min

appl

ies

Cavity drawing, PLC053

Machining tools can be purchased from Parker Hannifin.

Hydraulic symbol forpressure relief valve

Anti-cavitationvalve (N)

Unless stated otherwise:Edges broken 0.1-0.5 unlessindicated otherwise

6,3

Anti-cavitation valve (N)

Pressure relief valve

q (l/min)

T

P

5 Parker Hannifin ABMobile Controls DivisionBoras, Sweden

Pressure relief valvesPLC053 series

Catalogue HY17-8702/UK

Technical Information

P

T

~60 ~30

~35

A

A

YY6

WW12

5 4 3

X X3773

6

XXX/10P

T

Single housing

Hydraulic symbol for single housing

OrderingPLC053 mounted in single housingThe PLC053 mounted in a single housing can be ordered usingthe ordering numbers below. Should you require a pressure set-ting not listed in the table, please contact your Parker Hannifinrepresentative.

Pressure Ordering No[bar]

50 376731763 376731880 3767319

100 3767320125 3767321140 3767322160 3767323175 3767324190 3767325210 3767326230 3767327240 3767328250 3767329260 3767330270 3767331280 3767332

10 20 30

100

00

200

300

400

Diagram for PLC053 pressure relief valve

∆p (bar) Pressure override characteristic

q (l/min)

6 Parker Hannifin ABMobile Controls DivisionBoras, Sweden

Pressure relief valvesPLC082 series

Catalogue HY17-8702/UK

Dimensions

Cavity drawing, PLC082

46,5

min

37±

0,1

30 m

ax

20,5

max

0,1

A

4

16 m

in10

±0,

2

0,05 AA

4

44

4

8 m

in

M24x1,5 - 6H

Ø30+20

Ø18+0,110

Ø13+0,07

0

35°±1°

45°±5°

2,5

0,05 A

1±0,

1

R0,4 max

R0,2±0,1

15°±1° Ø25,30

-0,1

0,1R1±0,2

2±0,

2

A

2,5

30

25

5

15

10

20

00 25 50 75 100

300

500

400

100

200

00 25 50 75 100

Seat embossed with Ø16 mm class III steel ballImpact energy 12±2 NmStated dimensions apply before embossing

Inom

45 m

ingä

ller

Machining tools can be purchased from Parker Hannifin.

Diagram for PLC082 pressure relief valves

∆p (bar) Pressure override characteristic

q (l/min)∆p (bar) Anti-cavitation characteristic

Hydraulic symbol forpressure relief valveUnless stated otherwise:

Edges broken 0.1-0.5 unlessindicated otherwise

6,3

q (l/min)

P

T

T

P

7 Parker Hannifin ABMobile Controls DivisionBoras, Sweden

Pressure relief valvesPLC082 series

Catalogue HY17-8702/UK

Dimensions

40

18

(18)

5060

80

10

1538

86

75

18

P

T

Connection T, Tank*

Single housing

Hydraulic symbol for single housing

Connection P (pressure)*

SW = 12, T = 80 Nm

Mounting hole Ø11 (2x)

Connection P (pressure)*

*) Thread dimension G ½ or G ¾.See page 11.

SW = spanner widthT = tightening torque

8 Parker Hannifin ABMobile Controls DivisionBoras, Sweden

Pressure relief valvesPLC082 series

Catalogue HY17-8702/UK

Dimensions

32

11

40

1066421

(32)

7548

11,5

68

56

Connection T, Tank, plugged (G 3/4)

Mounting hole

Ø11 (3x) Connection M2, pressure (2x)*

Connection M1, pressure (2x)*

M1 T M2

Double housing

Hydraulsymbol för dubbelhus

*) Thread dimension G ½ or G ¾.See page 11.

SW = spanner widthT = tightening torque

SW = 12, T = 80 Nm (2x)

9 Parker Hannifin ABMobile Controls DivisionBoras, Sweden

Pressure relief valvesPLC182 series

Catalogue HY17-8702/UK

Technical Information

M24x1,5-6H

0,1A

A0,05

42,5

Ø0,2 AØ20 +0,084

0

0+0,07Ø14

19,5

min

27 m

ax

56±

0,1

**68

min

***7

2 m

in

21,5

min

0,5

A

14 min

11,5

±1,

5

Ø4 min

(56)

1±0,

2

0,05 A

2,5

35°±1°

R0,4 max alt.

R0,2±0,1 alt.

0,4x45° max

0,2±0,1x45°

0,7±

0,2

45°±5°

15°±1°

2,5

R1 max

2±0,

2

0,1 A

Ø25,30

-0,1

25 12550 15075 175100 200

10

5

15

25

00

20

30

25 12550 15075 175100 200

100

00

200

300

400

500

Seat embossed with Ø16 mm class III steel ballImpact energy 12±2 NmStated dimensions apply before embossing

** applies to Ø14 + 0.07/0*** applies to Ø14

Cavity drawing, PLC182

Diagram for PLC182 pressure relief valves

∆p (bar) Pressure override characteristic

q (l/min)

∆p (bar) Anti-cavitation characteristic

Machining tools can be purchased from Parker Hannifin.

Hydraulic symbol forpressure relief valve

Unless stated otherwise:Edges broken 0.1-0.5 unlessindicated otherwise

6,3

q (l/min)

P

T

T

P

10 Parker Hannifin ABMobile Controls DivisionBoras, Sweden

Pressure relief valvesPLC280 series

Catalogue HY17-8702/UK

Technical Information

26,5

a) 34 max

81,5

min

77,5

min

65,5

±0,

1

40 m

ax

26 m

ax20

min

3,2

0,1

16,5 max

60°±2°

0

9 0+0,2

2,5

Ø0,

1A

M B

4 Ø25

H11

M33

x2-6

H

Ø40

,2H

9

Ø44

,8H

11

A

Ø17

H10

Ø0,

1 0,05

0,05

B

2,5

A

2,5

3,7+0,20

2xR1±0,1

0,5±0,2x45°

3,3±0,2

R1 max

Ø35

,4+

0,1

0

0,1 A

2,5

R0,2±0,1 alt.0,2±0,1x45°

R0,6 max alt.

R0,4 max alt.

0,6x45° max

0,4x45° max

15°±1°

45°±5°

45°±1°

0,05 A

2,5

1±0,1

0,5+10

(65,5)

12,8 max

Ø5

min

2,5

Ø17H10

Ø25H11

Ø40H9

Ø44,8H11

+0,070

+0,062

+0,160

+0,1300

0

0

0

A

A

A – A

15

20

10

00

5

50 100 150 200 250 300 350

300

400

100

200

500

00 50 100 150 200 250 300 350

Seat embossed with Ø25 mm class II steel ballImpact energy 18±3 NmStated dimensions apply before embossing

a) For emergency operationSW = Spanner widthT = Tightening torque

Groove forO-ring 39.2 x 3

2x F

ree

from

bur

nsH

=0,

2 m

ax S

TD

508

0,34

1

Cavity drawing, PLC280

Diagram for PLC280 pressure relief valve

∆p (bar) Pressure override characteristic

q (l/min)∆p (bar) Anti-cavitation characteristic

Machining tools can be purchased from Parker Hannifin.

Without drainage of springchamber

With drainage of spring chamber

Unless stated otherwise:Edges broken 0.1-0.5 unlessindicated otherwise

6,3

Hydraulic symbol forpressure relief valve

q (l/min)

P

T

SW = 34 T = 150 Nm

11 Parker Hannifin ABMobile Controls DivisionBoras, Sweden

Pressure relief valvesPLC series

PLC-series pressure relief valves can be ordered using theordering numbers in the table below.

Should you require a pressure setting not listed in the table, or requirethe pressure setting to be made at a flow different to standard, pleasecontact your Parker Hannifin representative.

Pressure PLC053 PLC082 PLC182 PLC280[bar] with plug

40 — 9120 0291 03 9120 0292 50 —50 393000K176 9120 0291 04 9120 0292 51 —63 393000K177 9120 0291 05 9120 0292 52 —80 393000K178 9120 0291 06 9120 0292 53 —

100 393000K179 9120 0291 07 9120 0292 54 —125 393000K180 9120 0291 08 9120 0292 55 —140 393000K181 9120 0291 09 9120 0292 56 —160 393000K182 9120 0291 10 9120 0292 57 —175 393000K183 9120 0291 11 9120 0292 58 —190 393000K184 9120 0291 12 9120 0292 59 —210 393000K185 9120 0291 13 9120 0292 60 —230 393000K186 9120 0291 14 9120 0292 61 20006727250 393000K187 9120 0291 15 9120 0292 62 20004981280 393000K189 9120 0291 16 9120 0292 63 20007439300 393000K190 9120 0291 17 9120 0292 64 20005798330 393000K191 9120 0291 18 9120 0292 65 —350 393000K192 9120 0291 19 9120 0292 66 20000990380 393000W018 9120 0291 20 9120 0292 67 20006115400 — 9120 0291 21 9120 0292 68 —420 393000U020 9120 0291 22 9120 0292 69 00153491N* 393000K194 9120099686 — —

* Anti-cavitation valve without pressure-relief function

PLC082 mounted in single housingThe PLC082 mounted in a single housing can be ordered using theordering numbers below. Should you require a pressure setting notlisted in the table, please contact your Parker Hannifin representative.

Pressure G1/2 G3/4[bar]

50 3766780 3766789125 3766781 —160 3766782 —175 3766783 —190 3766784 3766903210 3766785 3766904230 3766786 3766862

PLC082 mounted in double housing

Pressure G1/2 G3/4[bar]

140 3766767 —160 3766769 3766777175 3766770 —190 3766771 —210 3766772 —230 3766773 3766900250 — 3766901280 — 3766873

Catalogue HY17-8702/UK

Ordering

Parker Hannifin is the world’s premier supplier of motion and control systemsand solutions, with sales and manufacturing facilities throughout the world. Forproduct information and details of your nearest Parker sales office, visit us atwww.parker.com or call free on 00800 2727 5374.

Hydraulics GroupSales Offices

AustriaWiener NeustadtTel: +43 (0)2622 23501Fax: +43 (0)2622 66212

BelgiumNivellesTel: +32 (0)67 280 900Fax: +32 (0)67 280 999

Czech RepublicKlecanyTel: +420 284 083 111Fax: +420 284 083 112

DenmarkBallerupTel: +45 4356 0400Fax: +45 4373 8431

FinlandVantaaTel: +358 (0)9 4767 31Fax: +358 (0)9 4767 3200

FranceContamine-sur-ArveTel: +33 (0)450 25 80 25Fax: +33 (0)450 03 67 37

GermanyKaarstTel: +49 (0)2131 4016 0Fax: +49 (0)2131 4016 9199

HungaryBudapestTel: +36 (06)1 220 4155Fax: +36 (06)1 422 1525

IrelandDublinTel: +353 (0)1 293 9999Fax: +353 (0)1 293 9900

ItalyCorsico (MI)Tel: +39 02 45 19 21Fax: +39 02 4 47 93 40

The NetherlandsOldenzaalTel: +31 (0)541 585000Fax: +31 (0)541 585459

NorwaySkiTel: +47 64 91 10 00Fax: +47 64 91 10 90

PolandWarsawTel: +48 (0)22 863 49 42Fax: +48 (0)22 863 49 44

PortugalLeca da PalmeiraTel: +351 22 9997 360Fax: +351 22 9961 527

SlovakiaRef. Czech Republic

SpainMadridTel: +34 91 675 73 00Fax: +34 91 675 77 11

SwedenSpångaTel: +46 (0)8 597 950 00Fax: +46 (0)8 597 951 10

TurkeyMerter/IstanbulTel.: +90 212 482 91 06 or 07Fax: +90 212 482 91 10

United KingdomWarwickTel: +44 (0)1926 317 878Fax: +44 (0)1926 317 855

InternationalEurope

Catalogue HY17-8702/UKPDF 08/05

© Copyright 2005Parker Hannifin CorporationAll rights reserved.

AustraliaCastle HillTel: +61 (0)2-9634 7777Fax: +61 (0)2-9899 6184

CanadaMilton, OntarioTel: +1 905-693-3000Fax: +1 905-876-0788

ChinaBeijingTel: +86 10 6561 0520Fax: +86 10 6561 0526

Asia Pacific GroupHong Kong, KowloonTel: +852 2428 8008Fax: +852 2425 6896

IndiaMumbaiTel: +91 22 7907081Fax: +91 22 7907080

JapanTokyoTel: +(81) 3 6408 3900Fax: +(81) 3 5449 7201

Latin America GroupBrazilTel: +55 12 3954-5100Fax: +55 12 3954-5266

South AfricaKempton ParkTel: +27 (0)11-961 0700Fax: +27 (0)11-392 7213

USACleveland (industrial)Tel: +1 216-896-3000Fax: +1 216-896-4031Lincolnshire (mobile)Tel: +1 847-821-1500Fax: +1 847-821-7600