axial_fans_2007_en.pdf

Upload: chaveliux7

Post on 02-Jun-2018

241 views

Category:

Documents


1 download

TRANSCRIPT

  • 8/10/2019 Axial_fans_2007_EN.pdf

    1/435

    version 07 Axial fans

    The engineers choice

  • 8/10/2019 Axial_fans_2007_EN.pdf

    2/435

    2

    Axial fans

    ebm-papst's axial fans prove their reputation as space-saving wonders by moving air for hot or cold

    air exchange in a wide variety of devices and systems. Their outstanding features are their small installation depth, low noise level and exceptional efficiency, and are particularly well suited for air

    flow through heat exchangers.

    Furthermore, in the EC version, they become intelligent "energy-saving wonders" for an extremely

    wide range of applications, primarily in ventilation, air-conditioning and refrigeration technology and

    the automotive industry.

    One principle, countless options

    The axial fan, the function of which is similar to

    a propeller, moves the air axially, parallel to therevolving motor shaft. The ebm-papst external

    rotor motor is integrated directly into the axial

    impeller, forming a compact axial fan unit. They

    are usually installed with wall rings in short or

    long nozzles.

    The extensive ebm-papst product range offers

    the right solution for each requirement and is

    classified for a wide variety of applications:

    S series with sickle-shaped blades for high

    air flow at medium pressure

    K series with especially low noise level ideally suited for refrigeration plant

    applications

    A series for high-pressure applications

    is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG

    Design according to requirements

    Energy efficiency, controllability and low-noise

    performance and all this together with

    external rotor motors in AC and EC technology:

    ebm-papst axial fans are optimally matched to

    customer requirements.

    The EC technology (12 VDC to 110 VDC or

    line-voltage-powered 100 VAC to 480 VAC) with

    integrated or external electronics enables

    precision open and closed-loop control with

    very high efficiency. The following standard

    features are available:

    tach output, error message, linear or PWM

    input, temperature or flow rate-dependent

    control systems or bus-connectable interface.

  • 8/10/2019 Axial_fans_2007_EN.pdf

    3/435

    3

    Table of content

    General information 4

    Company profile: ebm-papst

    Our key to success

    How to use this catalogue

    How to find your ebm-papst product

    How to order your ebm-papst product

    AC axial fans, AC diagonal fans 13

    AC axial fans, S series 23

    AC axial fans, K series 131

    AC axial fans, A series 157

    Square shaded-pole motors (Q-motor) 301

    Energy-saving motors (ESM) 315

    EC axial fans, EC diagonal fans 179

    EC axial fans, S series 185

    EC-SYSTEMS 329

    Options

    Switch power supplies

    External commutation electronics for rail technology

    Temperature sensor / control module

    Pressure control / selection module for 3 speeds

    Interface converter / RS485 repeater

    RS485 terminal box / hand-held control terminal

    Speed setting

    LISA control software / fan control software

    HMS controller

    Accessories 361

    Guard grilles, streamers

    Wall rings

    Connection leads

    Accessories for Q-motors and ESM Terminal boxes, capacitors

    Speed setting

    Motor protection switch

    Star-delta switch / repair switch

    Technology 391

    Technical parameters & scope

    Impellers

    Motors

    Control technology

    Distributors, agencies and subsidiaries 430

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x

    i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

  • 8/10/2019 Axial_fans_2007_EN.pdf

    4/435

    4

    Company profile: ebm-papst

    The entire scope of ventilation and drive technology: this is the world of ebm-papst. More than 9,800 people in

    Germany and throughout the world develop, produce and sell our motors and fans. Our global presence andour unique range of products based on a quality standard that surpasses every other have made us what we are:

    world market leader in motors and fans. Expertly knowing what our customers need and incessantly striving

    to arrive at the perfect application solution for a wide variety of different industries is what determines our daily

    work. Those who know us know the high standards we apply to our work and know our creed: to be as close

    to our customers as possible and to simply be the best in terms of innovation and reliability.

    Our headquarters in Mulfingen

  • 8/10/2019 Axial_fans_2007_EN.pdf

    5/435

    5

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    Left: Our location in St. Georgen

    Right: Our location in Landshut

    Our history Our drive

    Rooted in ebm, PAPST and mvl, the three leading innovators in thedevelopment and production of motors and fans, ebm-papst hasestablished itself as the world market leader. Now as ever, our legendaryinventive spirit shines through in products that set standards in manysegments of industry worldwide. We are proud to say that despite difficultcompetition, our performance has always been exemplary and outstand-ing in business, in our personal relationship with our customers, and ofcourse with respect to technology and engineering. For decades, we havecontributed to the world of air technology and drive engineering withsmall revolutions and large milestones.To maintain this advantage in skills and knowledge to get maximumquality and thus the highest degree of customer satisfaction, our

    employees around the world put their passion and dedication to work for you.

    Passionately involved in R&D

    Our catalogues just list the results of our incessant efforts in R&D:products of highest quality and reliability. After all, it is our passion toconstantly try something new and improve what we have. In doing so,we take advantage of the latest development methods and state-of-the-art technology and invest quite heavily in R&D facilities. Best of all,though, we rely on excellently trained and skilled engineers andtechnicians to be at your service in R&D and Sales & Distribution.

    Producing and safeguarding high-quality products and services

    This is our promise without any compromise. Whether produced in one ofour five factories in Germany or one of our eleven international productionsites, our products always have the same high level of quality. This qualitycontrol is something you can definitely rely on! And this across all levelsof production and throughout all processes: consulting customers, devel-opment, material selection through to picking certified, choice suppliersand on to the production of parts and final delivery. On top of this, ourproducts have to pass the most rigourous tests under all realistic operat-

    ing conditions: continuous stress test, salt spray test, vibration test, orprecision noise measuring, just to mention a few. And the product gets

    clearance for serial production only after all thedesired characteristics have been determined tobe just right.Environmental care is another priority withebm-papst. This is why we have developedour product line in EC technology, which makesfor very low power consumption. Due to ourmanufacturing philosophy, there is absolutefocus on environmental care in production,recycling, waste and waste water disposal.

    Global Domestic

    In order to be specialist for customised solutions

    throughout the world, you need strong partners.Global Domestic i.e. being present all over theworld and being a national company in eachindividual country is how we have establishedourselves in all important markets on this globewith our successful subsidiaries. And so you willalways find ebm-papst close to home, speakingyour language, and knowing the demands ofyour markets. Besides, our worldwide produc-tion alliance serves as a basis for competitivepricing. Our global services and logistic outlets,i.e. IT networking, safeguard short reactiontimes and just-in-time delivery.

    All our efforts are documented in a comprehen-sive quality management system, both for prod-ucts and services. Being certified as complyingwith the tough requirements of the internationalstandards DIN EN ISO 9001, ISO/TS 16949-2and of standard DIN EN ISO 14001 is just oneseal of approval we have received for our

    unceasing efforts to provide only the bestquality products and services.

  • 8/10/2019 Axial_fans_2007_EN.pdf

    6/435

    6

    Our key to success

    Our innovations and technologies keep on turning into new industrial standards. This competitive capabili ty canonly be maintained by seeing ventilation as a whole: the interrelationship between, and thus the system of, motor

    engineering, aerodynamics, and electronics. These are our three core competencies, imminently connected and

    linked in each of our products. And so we handle air intelligently and quietly and continue to set new standards in

    drive technology. Our system solutions form the main part of our product range by now. And they will be our main

    key to success.

    Motor engineering, aerodynamics, electronics

    Our drive is well known and famous with specialists: our external-rotormotor, which has made us world market leader quietly, yet powerfully.Being versatile as to integration, it is ideally suited to the most diverseapplications. Based on this principle, we here at ebm-papst have devel-oped the widest range of fans and motor types in the world. And for hotor aggressive blower mediums, the internal-rotor motor is the perfectcomplement.

    Still, in drive engineering, certain applications simply require the internal-rotor motor principle, and they are then realised with our motors specifi-cally developed for such cases. Take, for instance, the steering supportmotor in the automotive field developed as innovation in active steering.

    Be it axial or centrifugal fans, centrifugal blowers, compact fans ortangential blowers: we always design fan blades, impeller blades andducted housings with the specific application in mind. We strive tominimise noise and to optimise efficiency. This is the challenge thatwe have taken up and which we meet working away powerfully

    and quietly.

    Finally, intelligence will become the decisivefactor on all markets in future. After all, only inconnection with electronics can drive and airflow as a system solution have an optimaleffect in a product or application. Interfaces areavoided, and thus potential faults and failures.

    Setting new standards with EC technology

    Wherever intelligent air handling is required,where energy consumption needs to be reducedand performance has to be maximised, thereour EC motors are your reliable answer. They donot waste financial or natural resources.Instead, they boost high efficiency, continuouscontrollability via analogue or digital inputs,long and maintenance-free service life, androbustness.

    Production Winding machine

  • 8/10/2019 Axial_fans_2007_EN.pdf

    7/435

    7

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    Without any problems, the ebm-papst EC technology allows you to realisenetworked, bus-linked appliances, to integrate simple or complex controlsat low cost and to also realise time and again new, customised andcomplete solutions. Here, ebm-papst excels as competent developmentpartner, with our experience of more than 25 years and our excellentknow-how in R & D and production also being well documented in a fewhundred national and international patents. And there is also our abilityto listen intently, to pay good attention to our customers and theirdemands in order to come up with new and pioneering ideas, such as:

    EC fan units for clean room technology. As the electronics are integrated and the unitis wired up completely and ready to plug in,there is no need for our customers to wastetime and money on laborious wiring work.

    Sensitive EC sensor fans for the automotiveindustry providing optimal selection of theair-conditioning unit in the car and, combinedwith booster blowers, individual air-condition-ing of each and every passenger seat.

    EC gas blowers with commutation andcontrol electronics including a processor.They are developed in such a way as tomake the blower premix the required amountof air with the gas. Aerodynamics with theseblowers are adjusted in such a way as tomake these blowers ideal for use in verylimited space at high back pressure.

    Left: Endurance test room

    Centre: Shaker Right: Measurement station

    Top: Betz manometer

    Left: Precision noise measurement lab

  • 8/10/2019 Axial_fans_2007_EN.pdf

    8/435

    8

    56

    A C centrifugal fansbackward curved, 3-D, 400

    Ma teria l: Impeller: Sheet aluminium,joined by tabsRotor: Coated in black

    Number of bla des: 6 Direction of rota tion: Clockwise, seen on rotor Type of protection: IP 54 (acc.to EN60529) Insula tion cla ss: "F" Mounting position: Any Condens a te disch a rges: None Mode of opera tion: Continuous operation (S1) Bea rings: Maintenance-free ball bearings

    Nomina l da ta

    Type Motor

    R4E 400 M4E094-FA

    R4E 400 M4E094-HA

    subjectto alterations

    1000 2000 3000 4000

    0 500 1000 [CFM]1500 2000 2500

    [ P a ]

    100

    200

    300

    400

    500

    600

    0 , 5

    1 , 0

    1 , 5

    2 , 0

    [ i n H 2

    O ]

    2 , 5

    [m3 /h]

    60 Hz50 Hz

    2

    1

    A

    1

    2

    B

    Curves

    VAC Hz rpm W A F/VDB C p. 596 f.

    A2a)1~ 2 30 50 1355 375 1.75 8.0 /400 -40 to +60

    1 ~ 2 30 60 1480 540 2.40 8.0 /400 -40 to +501~ 2 30 50 1370 480 2.40 10.0 /450 -40 to +801 ~ 2 30 60 146 0 700 3.15 10.0 /450 -40 to +55

    A

    A2a)B

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n c y

    S p e e d

    / r p m ( 1 )

    C a p a c i t o r

    P e r m

    . a m b

    . t e m p

    .

    E l e c t r . c o n n e c t i o n

    (1) Nominal data in operating pointwith maximum load

    M a x

    . p o w e r

    i n p u t ( 1 )

    M a x

    . c u r r e n t

    d r a w ( 1 )

    13501380

    13701390

    n[rpm]

    P1[W]

    I[A]

    370331

    469

    430

    1.751.58

    2.372.17

    A

    B

    A

    B

    1

    2

    2

    1

    LpA[dB(A)]

    6465

    66

    68

    R4E 400 M4E094-F A2a)1~ 230 50 355 375 1.75 8.0 /400 40 to +60

    1 ~ 2 30 60 480 540 2.40 8.0 /400 40 to +50A

    1350 70 1.75A 1 4

    1

    A

    How to use this catalogue

    The ebm-papst catalogue combines a technical and a product-specific section.

    Technical section: General information on how to select and find ebm-papst products for your specificapplication is found in the chapters "Selection" (p. 10) and "Technical parameters" (p. 392).

    In case you require technical background information on ebm-papst product groups, simply turn to

    the chapters "Impellers" (p. 396), "Motors" (p.410) and "Control technology" (p. 414).

    Product-specific section: The product-specific section is organised according to product diameters,

    lines, materials and/or design principles.

    Headline

    The headline indicates which technology (AC or EC), which design(centrifugal, axial, etc.), and which line (e.g. S-Range) the product belongs

    to. Impeller diameter or other features are also indicated.

    Part designation / Type

    This key designates and identifies allebm-papst products and serves aspart number:

    1) Type A - axial fanS - axial fan with guard grille

    W - axial fan with wall ring V - axial combinationR - centrifugal fan, single inletG - centrifugal blower, single inlet (with scroll housing)B - centrifugal fan, dual inletD - centrifugal blower, dual inlet (with scroll housing)K - centrifugal combinationM - motorP - pumps

    2) Number of poles (AC) / number of cores (EC)2-, 4-, 6-, 8- and 12-pole (Z = 12) / 1- and 3-core

    3) Motor typeD - 3-phase motorE - single-phase motor with operating capacitorG - EC motorS - shaded-pole motorQ - square shaded-pole motors

    4) Impeller diameter in mm5) Key for mechanical design6) Key for electrical design7) Key for mechanical variants

    R 2 E 190 -AO 26 -05

    1 2 3 4 5 6 7

    What a product page is made up of (reduced scale - 50%)

  • 8/10/2019 Axial_fans_2007_EN.pdf

    9/435

    9

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    Mounting dimensions

    57

    Motor protection: Des ign with thermal overload protector Cable exit: Diagonal Protection cl a ss: I (acc.to EN61800-5-1) Product conforming to st a nda rd: CE

    Centrifug a l fa n

    R4E 400-AR05 -06

    R4E 400-AP17 -06

    Dimensions

    b c d e g

    1 41 .0 1 72 .0 1 28 .0 5 0. 0 90.0

    164.0 193 .0 1 48 .0 7 0. 0 1 13 .0

    kg

    7.1

    8.8

    Inlet nozzle(long)

    54476 -2-4013

    54476 -2-4013

    2

    b

    g

    5

    e

    d 1

    c 1

    1 2 4

    2 6 8

    4 0 4

    2 5 7

    3

    7 0

    66

    9 0

    5 0

    2 2

    0 , 3

    1 1 5

    M64 5

    - 0 , 4

    1 0 0

    6 0 0

    M a s s o f

    c e n t r i f u g a l f a n

    Capacitorp.5 60 f.

    Guard grillep.553

    Inlet nozzlep.550

    Electr.connectionsp.5 96 f.

    28

    5 5

    1 0 0

    1 1 5

    7

    G e n e r a l

    i n f o r m a t i o n

    A C

    c e n t r i f u g a l ,

    b a c k w a r d

    A C

    c e n t r i f u g a l ,

    f o r w a r d

    E C c

    e n t r i f u g a l ,

    b a c k w a r d

    E C

    c e n t r i

    f u g a l , b a c k -

    w a r d

    f o r c l e a n r o o m s

    E C c

    e n t r i f u g a l ,

    f o r w a r d

    E C - S

    Y S T E M

    S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    R4E 400-AR05 -06 1 41 .0 1 72 .0 1 28 .0 5 0. 0 90.07.1 54476 -2-4013

    Brass lead tipsDepth of screwmax. 12 mm

    Product description

    Depending on the product, information is provided here on the following:material, number of blades, direction of air flow, direction of rotation,

    system of protection, insulation class, mounting position, condensatedischarge holes, mode of operation, design, bearing, technical equipment,EMC, leakage current, motor protection, electrical connection, cable exit,protection class, capacitor, product conforming to standards, approvalsand options.

    Nominal data

    AC products (up to motor size 074) and EC products (DC-fed):Free-blowing or at minimal backpressure

    AC products (from motor size 094) and EC products (AC-fed):

    In operating point at maximum load

    Graphic rendition of products

    All drawings represent the design principle and are not to scale.Dimensions are either given in the product drawing or, with varyingdimensions, in the table of dimensions given above the drawing.

    Indication of relevant accessories and additional information

    The pages indicated at the bottom refer to the accessories, e.g. inletnozzles, guard grilles, wall rings, etc. for this particular product,as well as additional information (e. g. the connection diagram).

    Curves and operating points

    The diagram gives air performance curves pertaining to the product.Refer to the operating point table to the right for information on speed,

    power consumption, current draw, sound level or sound pressure leveland overall efficiency of the impeller.

  • 8/10/2019 Axial_fans_2007_EN.pdf

    10/435

    10

    How to select your ebm-papst product

    Solutions for ventilation offered by ebm-papst

    In the field of ventilation, ebm-papst offers the perfect solution for a vast number of applications. Depending on motor,

    impeller and control technology, there is almost no limit to the number of possible combinations, thus making sure you can

    find the best solution for your application.

    Criteria for selection

    When selecting a fan for a specific application, these parameters play animportant role: Air flow with given back pressure Voltage supply, divided into DC and AC voltage (1~ , 3~ ) Noise generation Efficiency Available mounting space

    Selecting a fan

    The following diagram shows the range of characteristic curves for themost important fan designs and serves as a helpful tool in preselectinga design on the basis of air flow and back pressure.

    Characteristic curves of the various designs

    axial fanscentrifugal fans , backward curvedcentrifugal blowers , s ingle inletcentrifugal blowers , dual inletdiagonal fans

    [m/h]

    [ P a ]

    1000200 500 2000 5000 10000 20000 50000

    200

    400

    600

    800

    1000

    1200

  • 8/10/2019 Axial_fans_2007_EN.pdf

    11/435

    11

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    How to order your ebm-papst product

    Have you found the suitable ebm-papst product and would like to order it now?

    In this case, simply contact your nearest ebm-papst sales office by E-mail, fax or phone.

    Don't know exactly which ebm-papst product you need to order?

    In this case, simply contact your nearest ebm-papst sales office byE-mail, fax or phone. Our specialists in ventilation and drive technologyare always there to help you find the best solution for your specificapplication.

    Using the questions provided in the checklist here as a guideline, you canmake sure your ebm-papst contact has all the necessary information tohandle your enquiry as efficiently and quickly as possible.

    How your ebm-papst product is delivered

    In our order confirmation, you will find information on when, how and

    where to the delivery will be made.

    We deliver: Ex works (excluding packaging) Via freight carrier (we also use postal services for shipments

    up to 30 kg)

    All the other details such as packaging, freight, insurance and customsduty will be settled with your ebm-papst contact prior to the time weissue our order confirmation.

    Is there anything else you need to know about your

    ebm-papst product?

    In this case, simply contact your nearest ebm-papst sales office byE-mail, fax or phone.We have the answer to your problem and arealways glad to be able to be of assistance.

    Using the questions provided in the checklist here as a guideline, you canmake sure your ebm-papst contact has all the necessary information tohandle your enquiry as efficiently and quickly as possible.

    Checklist

    Part designation / type Quantity needed Field of application Ambient conditions (humidity, temperature, climate) Impeller diameter Air flow Back pressure Voltage supply

    For your nearest sales office, please turn to page 430.

  • 8/10/2019 Axial_fans_2007_EN.pdf

    12/435

    12

  • 8/10/2019 Axial_fans_2007_EN.pdf

    13/435

    13

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    AC axial fans, AC diagonal fans

    AC diagonal fans 208 20

    AC axial fans 130 - 250 14

  • 8/10/2019 Axial_fans_2007_EN.pdf

    14/435

    14

    AC axial fans 130

    Material:Wall ring: Die-cast aluminium,

    coated in black Blades: Sheet steel, coated in black

    Rotor: Open, coated in black Number of blades: 7 Direction of air flow: "V", exhaust over

    struts Direction of rotation: Counter-clockwise,

    seen on rotor Type of protection: IP 20 Insulation class: "B" Mounting position: Any

    Nominal data

    Type Motor VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg

    W2S130-AA25 -01 M2S 052-CA

    p. 416 f.

    B)1~ 115 50 325 2800 41 49 80 -25 to +60

    1~ 115 60 380 3250 38 53 120 -25 to +801~ 230 50 325 2800 45 49 80 -25 to +501~ 230 60 380 3250 39 53 120 -25 to +70

    A

    W2S130-AA03 -01 M2S 052-CA B)1.1

    1.1

    A

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s

    E l e c t r . c o n n e c t i o n

    subject to alterations

    100 200 300

    0 50 100 150 [CFM]200

    [ P a ]

    40

    80

    120

    160

    0 , 2

    0 , 4

    0 , 6

    [ i n H

    2 O ]

    [m3 /h]

    60 Hz50 Hz

    A

    Curves

    Guard grillep. 368

    1500.5

    550.3

    1 7 2

    0 . 5

    6 5 4

    , 3 5

    / 4

    , 4 5

    - 0 . 0

    5

    1 6 2

    + 0 . 1

    - 0 . 3

    Electr. connectionsp. 416 f.

    "V"

    Condensate discharges: None Mode of operation:

    Continuous operation (S1) Bearings: Maintenance-free ball bearings

    Motor protection: TOP wired internally Electrical connection:Cable length 330 mm, beginning at wall ring

    Protection class: I Product conforming to standards:

    EN 60335-1, CE Approvals: VDE, UL, CSA, CCC, GOST

    Brass lead tips

  • 8/10/2019 Axial_fans_2007_EN.pdf

    15/435

    15

    AC axial fans 130

    Material:Wall ring: Die-cast aluminium,

    coated in black Blades: Sheet steel, coated in black

    Rotor: Open, coated in black Number of blades: 5 Direction of air flow: "A", intake over

    struts Direction of rotation: Counter-clockwise,

    seen on rotor Type of protection: IP 20 Insulation class: "B" Mounting position: Any

    Nominal data

    Type Motor VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg

    W2S130-BM15-01 M2S 052-CA

    p. 416 f.

    B)1~ 115 50 380 2700 47 60 -25 to +50

    1~ 115 60 425 3050 46 62 -25 to +701~ 230 50 380 2700 47 60 -25 to +501~ 230 60 425 3050 46 62 -25 to +70

    B

    W2S130-BM03-01 M2S 052-CA B)1.1

    1.1

    B

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s

    E l e c t r . c o n n e c t i o n

    subject to alterations

    100 200 300 400

    0 50 100 150 [CFM]200 250

    [ P a ]

    20

    40

    60

    80

    100

    120

    0 , 1

    0 , 2

    0 , 3

    0 , 4

    [ i n H

    2 O ]

    [m3 /h]

    60 Hz50 Hz

    B

    Curves

    Guard grillep. 368 f.

    Electr. connectionsp. 416 f.

    66

    1 5 0

    0

    . 5

    550.2162+0.15 -0.30

    1720.5

    4

    , 4 5

    - 0 . 0

    5 / 4

    , 2 0

    + 0

    . 0 5

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    "A"

    Condensate discharges: None Mode of operation:

    Continuous operation (S1) Bearings: Maintenance-free ball bearings

    Motor protection: TOP wired internally Electrical connection:Cable length 330 mm, beginning at wall ring

    Protection class: I Product conforming to standards:

    EN 60335-1, CE Approvals: VDE, UL, CSA, CCC, GOST

    Brass lead tips

  • 8/10/2019 Axial_fans_2007_EN.pdf

    16/435

    16

    AC axial fans 142

    Material:Wall ring: Die-cast aluminium,

    coated in black Blades: Sheet steel, coated in black

    Rotor: Open, coated in black Number of blades: 7 Direction of air flow: "V", exhaust over

    struts Direction of rotation: Counter-clockwise,

    seen on rotor Type of protection: IP 22 Insulation class: "B" Mounting position: Any

    Nominal data

    Type Motor VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg

    W2E142-BB05 -01 M2E 052-BA 1~ 115 50 330 2800 25 52 -25 to +55

    1~ 115 60 390 3300 24 57 -25 to +701~ 230 50 330 2800 25 52 -25 to +551~ 230 60 390 3300 24 57 -25 to +70

    A

    W2E142-BB01 -01 M2E 052-BA 0.9

    0.9

    A

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s

    subject to alterations

    100 200 300 400

    0 50 100 200 [CFM]150

    [ P a ]

    40

    80

    120

    160

    200

    0 , 2

    0 , 4

    0 , 6

    [ i n H

    2 O ]

    [m3 /h]

    60 Hz50 Hz

    A

    Curves

    Guard grillep. 368 f.

    Connection leadp.374

    119

    38+0,5

    152,5

    1620,2

    1 5 0

    + 0

    , 5

    172+0,5

    4

    , 2

    0 , 1

    80,1

    "V"Blade terminal 2.8 x 0.5 mm

    Condensate discharges: None Mode of operation:

    Continuous operation (S1) Bearings: Maintenance-free ball bearings

    Motor protection: TOP wired internally Electrical connection: Blade terminal2.8 x 0.5 mm (operating capacitorconnected)

    Protection class: I Product conforming to standards:

    EN 60335-1, CE Approvals: VDE, UL, CSA, CCC, GOST

  • 8/10/2019 Axial_fans_2007_EN.pdf

    17/435

    17

    AC axial fans 143

    Material:Wall ring: Die-cast aluminium,

    coated in black Blades: Sheet steel, coated in black

    Rotor: Open, coated in black Number of blades: 5 Direction of air flow: "V", exhaust over

    struts Direction of rotation: Counter-clockwise,

    seen on rotor Type of protection: IP 20 Insulation class: "B" Mounting position: Any

    Nominal data

    Type Motor VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg

    W2E143 -AA15 -01 M2E 052-BF 1~ 115 50 375 2800 24 55 -25 to +70

    1~ 115 60 440 3300 26 60 -25 to +701~ 230 50 375 2800 24 55 -25 to +701~ 230 60 440 3300 26 60 -25 to +70

    B

    W2E143 -AA09 -01 M2E 052-BF 1.0

    1.0

    B

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s

    subject to alterations

    100 200 300 400

    0 50 100 150 [CFM]200 250

    [ P a ]

    40

    80

    120

    160

    200

    0 , 2

    0 , 4

    0 , 6

    [ i n H

    2 O ]

    [m3 /h]

    60 Hz50 Hz

    B

    Curves

    Guard grillep. 368 f.

    Connection leadp.374

    171,50,4

    162

    9 6 1

    861

    1 6 5 0

    , 4

    8 , 8

    510,3

    4

    , 6 / 4

    , 7 5 - 0

    , 4

    7 6 1

    2 5 1

    7,2+0,1 -0,3 7,2

    +0,1 -0,3

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    "V" Blade terminal 2.8 x 0.5 mm

    Condensate discharges: None Mode of operation:

    Continuous operation (S1) Bearings: Maintenance-free ball bearings

    Motor protection: TOP wired internally Electrical connection: Blade terminal2.8 x 0.5 mm (operating capacitorconnected)

    Protection class: I Product conforming to standards:

    EN 60335-1, CE Approvals: VDE, UL, CSA, CCC, GOST

  • 8/10/2019 Axial_fans_2007_EN.pdf

    18/435

    18

    AC axial fans 143

    Material:Wall ring: Die-cast aluminium,

    coated in black Blades: Sheet steel, coated in black

    Rotor: Open, coated in black Number of blades: 5 Direction of air flow: "V", exhaust over

    struts Direction of rotation: Counter-clockwise,

    seen on rotor Type of protection: IP 20 Insulation class: "B" Mounting position: Any

    Nominal data

    Type Motor VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg

    W2E143-AB15 -01 M2E 052-BF 1~ 115 50 420 2800 26 54 -25 to +60

    1~ 115 60 500 3300 29 58 -25 to +751~ 230 50 420 2800 26 54 -25 to +601~ 230 60 500 3300 29 58 -25 to +75

    A

    W2E143-AB09 -01 M2E 052-BF 1.0

    1.0

    A

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s

    subject to alterations

    100 200 300 400

    0 50 100 150 [CFM]200 250

    [ P a ]

    40

    80

    120

    160

    200

    0 , 2

    0 , 4

    0 , 6

    [ i n H

    2 O ]

    [m3 /h]

    60 Hz50 Hz

    A

    Curves

    Guard grillep. 368 f.

    Connection leadp.374

    171,50,4

    162

    9 6 1

    861

    1 6 5 0

    , 4

    8 , 8

    510,3

    4

    , 6 / 4

    , 7 5 - 0

    , 4

    7 6 1

    2 5 1

    7,2+0,1 -0,3 7,2

    +0,1 -0,3

    "V" Blade terminal 2.8 x 0.5 mm

    Condensate discharges: None Mode of operation:

    Continuous operation (S1) Bearings: Maintenance-free ball bearings

    Motor protection: TOP wired internally Electrical connection: Blade terminal2.8 x 0.5 mm (operating capacitorconnected)

    Protection class: I Product conforming to standards:

    EN 60335-1, CE Approvals: VDE, UL, CSA, CCC, GOST

  • 8/10/2019 Axial_fans_2007_EN.pdf

    19/435

    19

    AC axial fans 200

    Material:Wall ring: Die-cast aluminiumBlades: Sheet steel, coated in black Rotor: Coated in black

    Number of blades: 7 Direction of air flow: "V", exhaust overstruts

    Direction of rotation: Counter-clockwise,seen on rotor

    Type of protection: IP 44 Insulation class: "B" Mounting position: Any Condensate discharges: None

    Nominal data

    Type Motor VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg

    W2E200-HK86 -01 M2E 068-BF 1~ 115 50 925 2550 64 0.58 5.0 /220 59 100 -25 to +60

    1~ 115 60 1030 2800 80 0.70 5.0 /220 61 120 -25 to +651~ 230 50 925 2550 64 0.29 1.5 /400 59 100 -25 to +601~ 230 60 1030 2800 80 0.35 1.5 /400 61 120 -25 to +65

    B

    W2E200-HK38 -01 M2E 068-BF 2.0

    2.0

    B

    1~ 230 50 450 1370 30 0.21 40 50 -25 to +701~ 230 60 525 1590 26 0.18 44 50 -25 to +80W4S200-HK04 -01 M4S 068-BF 2.0C

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s

    subject to alterations

    200 400 600 800

    0 100 300 400 [CFM]200 500

    [ P a ]

    20

    40

    60

    80

    100

    120

    140

    160

    0 , 2

    0 , 4

    0 , 6

    [ i n H

    2 O ]

    [m3 /h]

    60 Hz50 Hz

    B

    C

    Curves

    Guard grillep.369

    PE N L

    (1)ca. 2

    260

    240 4

    , 5 +

    0 , 2

    2 2 5

    1 2

    72,6

    4

    800,3

    240260

    2 2 5

    4 , 5

    + 0 , 2

    1 2

    4

    NPE L

    2,67

    80 0,3

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    W2E200-HK

    (1) Protruding capacitor

    W4S200-HK

    "V"

    "V"

    Mode of operation:Continuous operation (S1)

    Bearings: Maintenance-free ball bearings Motor protection: TOP wired internally

    Electrical connection: Terminal strips(operating capacitor connected) Protection class: I Product conforming to standards:

    EN 60335-1, CE Approvals: VDE, UL, CSA, CCC;

    also GOSTB

    Capacitorp. 382 f.

  • 8/10/2019 Axial_fans_2007_EN.pdf

    20/435

    20

    AC diagonal fans 208

    Material:Wall ring: Die-cast aluminiumBlades: Plastic PA Rotor: Coated in black

    Number of blades: 5 Direction of air flow: "V", exhaust overstruts

    Direction of rotation: Counter-clockwise,seen on rotor

    Type of protection: IP 44 Insulation class: "F" Mounting position: Any Condensate discharges: None

    Nominal data

    Type Motor VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg

    W2D208-BA02 -01 M2D068-CF 3~ 400 Y 50 820 2740 60 0.15 67 135 -25 to +70

    3~ 400 Y 60 920 3090 80 0.15 70 165 -25 to +701~ 115 50 815 2750 67 0.70 6.0 /220 68 135 -25 to +721~ 115 60 925 3100 87 0.78 6.0 /220 70 165 -25 to +72

    A

    W2E208-BA86 -01 M2E 068-CF 2.8

    2.8

    B

    1~ 230 50 815 2750 67 0.33 1.5 /450 68 135 -25 to +721~ 230 60 925 3100 87 0.39 1.5 /450 70 165 -25 to +72W2E208-BA20 -01 M2E 068-CF 2.8B

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s

    subject to alterations

    200 400 600 800

    0 100 300 400 [CFM]200

    [ P a ]

    20

    40

    60

    80

    100

    120

    140

    160

    0 , 2

    0 , 4

    0 , 6

    [ i n H

    2 O ]

    [m3 /h]

    60 Hz50 Hz

    500

    BA

    1

    2

    3

    4

    Curves

    3090299029602990

    n

    [rpm]

    P1

    [W]

    LpA

    [dB(A)]80939692

    70696970

    A

    A

    A

    A

    1

    2

    4

    3

    3100299029603020

    n

    [rpm]

    P1

    [W]

    LpA

    [dB(A)]87

    10010297

    70706970

    B

    B

    B

    B

    1

    2

    4

    3

    Capacitorp. 382 f.

    Guard grillep. 367

    4

    , 5

    4

    , 5

    10 0,310 0,3

    "V"

    Section C-C

    Mode of operation:Continuous operation (S1)

    Bearings: Maintenance-free ball bearings Motor protection: Without TOP,

    TOP wired internally Electrical connection: Terminal strips(operating capacitor connected)

    Protection class: I Product conforming to standards:

    EN 60335-1, also CE Approvals: VDE, CCC, GOST

    B

    B

    A

  • 8/10/2019 Axial_fans_2007_EN.pdf

    21/435

    21

    AC axial fans 250

    Material:Wall ring: Die-cast aluminiumBlades: Sheet steel, coated in black Rotor: Coated in black

    Number of blades: 7 Direction of air flow: "V", exhaust overstruts

    Direction of rotation: Counter-clockwise,seen on rotor

    Type of protection: IP 44 Insulation class: "F" Mounting position: Any Condensate discharges: None

    Nominal data

    Type Motor VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg

    W2E 250-HL06 -01 M2E 068-CF 1~ 230 50 1865 2550 127 0.56 4.0 /400 69 100 -25 to +60

    1~ 230 60 1970 2700 180 0.79 4.0 /400 70 100 -25 to +45C 2.0

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s

    subject to alterations

    400 800 1200 1600

    0 200 400 800 [CFM]6 00

    [ P a ]

    20

    40

    60

    80

    100

    120

    140

    0 , 1

    0 , 2

    0 , 5

    [ i n H

    2 O ]

    [m3 /h]

    6 0 Hz50 Hz

    0 , 3

    0 , 4

    C

    Curves

    Capacitorp. 382 f.

    Guard grillep.369

    PE N L

    320

    295 5

    , 4 + 0

    , 2

    2 8 0

    1 2

    7

    2,6

    4

    80 0,3

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    "V"

    Mode of operation:Continuous operation (S1)

    Bearings: Maintenance-free ball bearings Motor protection: TOP wired internally

    Electrical connection: Terminal strips(operating capacitor connected) Protection class: I Product conforming to standards:

    EN 60335-1, CE Approvals: VDE, UL, CSA, CCC, GOST

  • 8/10/2019 Axial_fans_2007_EN.pdf

    22/435

    22

  • 8/10/2019 Axial_fans_2007_EN.pdf

    23/435

    23

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    AC axial fansS series

    AC axial fans, S series 500 - 910 74

    AC axial fans, S series 200 - 450 24

  • 8/10/2019 Axial_fans_2007_EN.pdf

    24/435

    24

    AC axial fansS series, 200

    Material: Guard grille: Steel, phosphated and coated in black plasticWall ring: Sheet steel, pre-galvanised and coated in black plasticBlades: Sheet steel, coated in black Rotor: Coated in black

    Number of blades: 9 Direction of rotation: Counter-clockwise, seen on rotor Type of protection: IP 44 Insulation class: "B" Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request Condensate discharges: Rotor-side Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings

    Nominal data

    Type Motor

    *2D 200(1) M2D068-BF

    *2E 200 M2E 068-BF

    *4D 200(1) M4D068-BF

    subject to alterations

    200 400 600 800

    0 100 300 400 [CFM]200 500

    [ P a ]

    20

    40

    60

    80

    100

    120

    140

    0 , 1

    0 , 2

    0 , 4

    0 , 5

    [ i n H

    2 O ]

    0 , 3

    [m3 /h]

    60 Hz50 Hz

    2

    2

    1

    1

    AC

    Curves

    25402470

    14301420

    n[rpm]

    P1[W]

    7074

    2123

    A

    C

    A

    C

    1

    2

    2

    1

    VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg p. 416 f.

    C1)/C2)3~ 230/400 50 890 2600 68 0.29/0.17 65 140 -25 to +45

    3~ 230/400 60 990 2900 70 0.23/0.13 68 140 -25 to +701~ 230 50 890 2600 64 0.30 1.5 /400 65 150 -25 to +701~ 230 60 990 2900 78 0.34 1.5 /400 68 150 -25 to +70

    A

    A1)1.4

    1.6

    B

    *4S 200 M4S 068-BF 1~ 230 50 470 1370 30 0.21 42 50 -25 to +75

    1~ 230 60 540 1580 27 0.19 46 50 -25 to +80 B)1.2D

    3~ 230/400 50 500 1440 20 0.12/0.07 43 70 -25 to +803~ 230/400 60 600 1690 20 0.10/0.06 47 90 -25 to +90 C1)/C2)1.4C

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s w i t h o u t

    a t t a c h m

    e n t s

    E l e c t r . c o n n e c t i o n

    (1) 230 VAC / 400 VAC Y

    I[A]

    0.29/0.170.29/0.17

    0.12/0.070.12/0.07

  • 8/10/2019 Axial_fans_2007_EN.pdf

    25/435

    "V" A4S 200-AH04 -01 A4S 200-AI04 -01

    W4S 200-CH04 -01W4S 200-CI04 -01

    S4S 200-BH04 -01S4S 200-BI04 -01

    S4S 200-AH04 -01S4S 200-AI04 -01"A"

    25

    Motor protection: Without TOP, TOP wired internally Cable exit: Lateral, variable Protection class: I Product conforming to standards: EN 60335-1, also CE

    Approvals: CCCB

    DB

    DBCA

    DBCA

    Withoutattachments

    With guard grillefor full nozzle

    With fullround nozzle (1)

    With guard grillefor short nozzle

    "V" A2D 200-AH18 -01 A2D 200-AI18 -01

    W2D200-CH18 -01W2D200-CI18 -01

    S2D 200-BH18 -01S2D 200-BI18 -01

    S2D 200-AH18 -01S2D 200-AI18 -01"A"

    "V" A2E 200-AH38 -01 A2E 200-AI38 -01

    W2E 200-CH38 -01W2E 200-CI38 -01

    S2E 200-BH38 -01S2E 200-BI38 -01

    S2E 200-AH38 -01S2E 200-AI38 -01"A"

    "V" A4D 200-AH14 -01 A4D 200-AI14 -01

    W4D200-CH14 -01W4D200-CI14 -01

    S4D 200-BH14 -01S4D 200-BI14 -01

    S4D 200-AH14 -01S4D 200-AI14 -01"A"

    D i r e c t i o n o

    f a i r

    f l o w

    200 400 600 800

    0 100 300 400 [CFM]200 500

    [ P a ]

    20

    40

    60

    80

    100

    120

    140

    160

    0 , 2

    0 , 4

    0 , 6

    [ i n H

    2 O ]

    [m3 /h]

    60 Hz50 Hz

    2

    2

    1

    1

    BD

    B

    D

    B

    D

    25552465

    13601350

    6770

    3131

    0.310.32

    0.220.22

    1

    2

    2

    1

    Curves

    "V"/"A" "V"/"A" "V"/"A" "V"/"A"

    Terminal boxp.381

    Wall ringp. 372 f.

    Guard grillep. 362 f.

    Drawingsp. 26 f.

    Capacitorp. 382 f.

    Electr. connectionsp. 416 f.

    n[rpm]

    P1[W]

    I[A]

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    (1) Increased noise levels in "V" direction of air flow

  • 8/10/2019 Axial_fans_2007_EN.pdf

    26/435

    26

    AC axial fansS series, 200, drawings of directions of air flow "V" and "A"

    9 0

    58

    2 7

    M4

    0,2

    - 2

    9 2

    1 9 7

    39

    - 0 , 1

    2 7

    17

    2

    5

    362

    8520450

    6

    3

    Without attachments Type

    A2D 200-AH18 -01 A2D 200-AI18 -01 A2E 200-AH38 -01 A2E 200-AI38 -01 A4D 200-AH14 -01 A4D 200-AI14 -01 A4S 200-AH04 -01 A4S 200-AI04 -01

    "V""A""V""A""V""A""V""A"

    5

    7

    6 x 6 0

    2 5 0

    2 8 0

    2 0 0

    80

    1 5

    1 , 2

    5

    9

    With full round nozzle Type

    W2D200-CH18 -01W2D200-CI18 -01W2E200-CH38 -01W2E 200-CI38 -01W4D200-CH14 -01W4D200-CI14 -01W4S200-CH04 -01W4S 200-CI04 -01

    "V""A""V""A""V""A""V""A"

    4,5

    2 4 5

    3,9

    With guard grille for full nozzle Type

    S2D 200-BH18 -01

    S2D 200-BI18 -01S2E 200-BH38 -01S2E 200-BI38 -01S4D 200-BH14 -01S4D 200-BI14 -01S4S 200-BH04 -01S4S 200-BI04 -01

    "V"

    "A""V""A""V""A""V""A"

    "V""A"

    "V""A"

    "V""A"

    Depth of screwmax. 5 mm

    Brass lead tips

  • 8/10/2019 Axial_fans_2007_EN.pdf

    27/435

    27

    463,9

    23513 7

    2 6 0

    2 2 9

    With guard grille for short nozzle Type

    S2D 200-AH18 -01S2D 200-AI18 -01S2E 200-AH38 -01S2E 200-AI38 -01S4D 200-AH14 -01S4D 200-AI14 -01S4S 200-AH04 -01S4S 200-AI04 -01

    "V""A""V""A""V""A""V""A"

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    "V"

    "A"

  • 8/10/2019 Axial_fans_2007_EN.pdf

    28/435

    28

    AC axial fansS series, 250

    Material: Guard grille: Steel, phosphated and coated in black plasticWall ring: Sheet steel, pre-galvanised and coated in black plasticBlades: Sheet steel, coated in black Rotor: Coated in black

    Number of blades: 7 Direction of rotation: Counter-clockwise, seen on rotor Type of protection: IP 44 Insulation class: "B" Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request Condensate discharges: Rotor-side Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings

    Nominal data

    Type Motor

    *2D 250(1) M2D068-CF

    *2E 250 M2E 068-CF

    *4D 250(1) M4D068-CF

    subject to alterations

    400 800 1200 1600

    0 200 400 800 [CFM]6 00

    [ P a ]

    20

    40

    60

    80

    100

    120

    140

    0 , 1

    0 , 2

    0 , 5

    [ i n H

    2 O ]

    [m3 /h]

    6 0 Hz50 Hz

    0 , 3

    0 , 4

    2

    2

    1

    1

    A

    D

    E

    Curves

    24552310

    13701360

    1370

    1360

    n[rpm]

    P1[W]

    106125

    4345

    71

    73

    A

    D

    E

    A

    D

    E

    1

    2

    2

    2

    1

    1

    VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg p. 416 f.

    C1)/C2)3~ 230/400 50 1830 2500 100 0.34/0.20 69 150 -25 to +65

    3~ 230/400 60 1950 2650 140 0.40/0.23 70 150 -25 to +451~ 230 50 1820 2450 115 0.51 3.0 /400 69 120 -25 to +651~ 230 60 1970 2600 150 0.66 3.0 /400 71 85 -25 to +50

    A

    A1)1.9

    2.1

    B

    3~ 230/400 50 1010 1400 25 0.12/0.07 54 70 -25 to +853~ 230/400 60 1140 1580 32 0.12/0.07 57 70 -25 to +80 C1)/C2)1.9C

    *4E 250 M4E 068-BF 1~ 230 50 1010 1400 42 0.19 1.5 /400 54 80 -25 to +55

    1~ 230 60 1200 1630 45 0.20 1.5 /400 58 100 -25 to +70 A1)1.9D

    *4S 250 M4S 068-CF 1~ 230 50 1000 1390 69 0.53 54 80 -25 to +50

    1~ 230 60 1160 1600 63 0.45 58 80 -25 to +65 B)1.7E

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s w i t h o u t

    a t t a c h m

    e n t s

    E l e c t r . c o n n e c t i o n

    (1) 230 VAC / 400 VAC Y

    I[A]

    0.34/0.200.38/0.22

    0.200.20

    0.53

    0.53

  • 8/10/2019 Axial_fans_2007_EN.pdf

    29/435

    29

    Motor protection: Without TOP, TOP wired internally Cable exit: Lateral, variable Protection class: I Product conforming to standards: EN 60335-1, also CE

    Approvals: CCC; also GOSTDDBA

    EDB

    DBECA

    EDBCA

    Withoutattachments

    With guard grillefor full nozzle

    With fullround nozzle (1)

    With guard grillefor short nozzle

    "V" A2D 250-AH02 -01 A2D 250-AI02 -01

    W2D250-CH02 -01W2D250-CI02 -01

    S2D 250-BH02 -01S2D 250-BI02 -01

    S2D 250-AH02 -01S2D 250-AI02 -01"A"

    "V" A2E 250-AL06 -01 A2E 250-AM06 -01

    W2E 250-CL06 -01W2E 250-CM06 -01

    S2E 250-BL06 -01S2E 250-BM06 -01

    S2E 250-AL06 -01S2E 250-AM06 -01"A"

    "V" A4D 250-AH22 -01 A4D 250-AI22 -01

    W4D250-CH22 -01W4D250-CI22 -01

    S4D 250-BH22 -01S4D 250-BI22 -01

    S4D 250-AH22 -01S4D 250-AI22 -01"A"

    D i r e c t i o n o

    f a i r

    f l o w

    400 800 1200 1600

    0 200 600 800 [CFM]400

    [ P a ]

    20

    40

    60

    80

    100

    120

    140

    0 , 1

    0 , 2

    0 , 3

    0 , 5

    [ i n H

    2 O ]

    0 , 4

    [m3 /h]

    6 0 Hz50 Hz

    2

    2

    1

    1

    B

    C

    B

    C

    B

    C

    24552290

    13751350

    116132

    2730

    1

    2

    2

    1

    Curves

    "V"/"A" "V"/"A" "V"/"A" "V"/"A"

    Terminal boxp.381

    Wall ringp. 372 f.

    Guard grillep. 362 f.

    Drawingsp. 30 f.

    Capacitorp. 382 f.

    Electr. connectionsp. 416 f.

    n[rpm]

    P1[W]

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    "V" A4E 250-AH02 -01 A4E 250-AI02 -01

    W4E 250-CH02 -01W4E 250-CI02 -01

    S4E 250-BH02 -01S4E 250-BI02 -01

    S4E 250-AH02 -01S4E 250-AI02 -01"A"

    "V" A4S 250-AH02 -01 A4S 250-AI02 -01

    W4S 250-CH02 -01W4S 250-CI02 -01

    S4S 250-BH02 -01S4S 250-BI02 -01

    S4S 250-AH02 -01S4S 250-AI02 -01"A"

    (1) Increased noise levels in "V" direction of air flow

    I[A]

    0.510.57

    0.12/0.070.12/0.07

  • 8/10/2019 Axial_fans_2007_EN.pdf

    30/435

    30

    AC axial fansS series, 250, drawings of directions of air flow "V" and "A"

    9 0

    58

    2 7

    M4

    0,2

    - 2

    9 2

    2 5 1

    34

    - 0 , 1

    2 7

    c

    2

    5

    3a

    8520450

    6

    3

    Without attachments Type a c A2D 250-AH02 -01 A2D 250-AI02 -01 A2E 250-AL06 -01 A2E 250-AM06 -01 A4D 250-AH22 -01 A4D 250-AI22 -01 A4E 250-AH02 -01 A4E 250-AI02 -01 A4S 250-AH02 -01 A4S 250-AI02 -01

    72.072.072.072.072.072.062.062.072.072.0

    18.021.018.027.018.027.014.022.018.023.0

    "V""A""V""A""V""A""V""A""V""A"

    6

    7

    6 x 6 0

    2 9 5

    3 2 0

    2 5 7

    87

    1 5

    1 , 2

    5

    9

    With full round nozzle Type

    W2D250-CH02 -01W2D250-CI02 -01W2E 250-CL06 -01W2E250-CM06 -01W4D250-CH22 -01W4D250-CI22 -01W4E250-CH02 -01W4E 250-CI02 -01

    W4S250-CH02 -01W4S 250-CI02 -01

    "V""A""V""A""V""A""V""A"

    "V""A"

    4,5

    2 9 0

    3,9h

    k

    With guard grille for full nozzle Type h k S2D 250-BH02 -01

    S2D 250-BI02 -01S2E 250-BL06 -01S2E 250-BM06 -01S4D 250-BH22 -01S4D 250-BI22 -01S4E 250-BH02 -01S4E 250-BI02 -01S4S 250-BH02 -01S4S 250-BI02 -01

    5.0

    05.005.005.005.00

    10.0

    010.00

    10.00

    10.00

    10.00

    "V"

    "A""V""A""V""A""V""A""V""A"

    "V""A"

    "V""A"

    "V""A"

    Depth of screwmax. 5 mm

    Brass lead tips

  • 8/10/2019 Axial_fans_2007_EN.pdf

    31/435

    31

    m3,9

    7

    3 0 0

    2 7 1

    n

    vu

    With guard grille for short nozzle Type m nS2D 250-AH02 -01S2D 250-AI02 -01S2E 250-AL06 -01S2E 250-AM06 -01S4D 250-AH22 -01S4D 250-AI22 -01S4E 250-AH02 -01S4E 250-AI02 -01S4S 250-AH02 -01S4S 250-AI02 -01

    50.045.050.045.050.045.050.045.050.045.0

    5.005.005.005.005.00

    u v

    14.017.014.023.014.023.010.018.014.019.0

    34.034.034.034.034.034.024.024.034.034.0

    "V""A""V""A""V""A""V""A""V""A"

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    "V""A"

  • 8/10/2019 Axial_fans_2007_EN.pdf

    32/435

    32

    AC axial fans2-poleS series, 300

    Material: Guard grille: Steel, phosphated and coated in black plasticWall ring: Sheet steel, pre-galvanised and coated in black plasticBlades: Sheet steel, coated in black Rotor: Coated in black

    Number of blades: 5 Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"counter-clockwise, seen on rotor

    Type of protection: IP 44 Insulation class: "B" Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request Condensate discharges: Rotor-side Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings

    Nominal data

    Type Motor

    *2D 300(1) M2D074-DF

    *2E 300 M2E 074-DF

    subject to alterations

    1000 2000 3000

    0 500 1000 2000 [CFM]1500

    [ P a ]

    40

    80

    120

    160

    200

    0 , 2

    0 , 4

    0 , 6

    [ i n H

    2 O ]

    [m3 /h]

    6 0 Hz50 Hz

    2

    1

    A

    Curves

    25302400

    n[rpm]

    P1[W]

    228273

    A

    A

    1

    2

    VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg p. 416 f.

    C1)/C2)3~ 230/400 50 3130 2580 210 0.62/0.36 72 200 -25 to +55

    3~ 230/400 60 3350 2750 300 0.83/0.48 73 125 -25 to +401~ 230 50 3410 2700 230 1.10 8.0 /400 73 200 -25 to +501~ 230 60 3740 3000 350 1.55 8.0 /400 76 50 -25 to +40

    A

    A1)3.0

    3.0

    B

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s w i t h o u t

    a t t a c h m

    e n t s

    E l e c t r . c o n n e c t i o n

    (1) 230 VAC / 400 VAC Y

    I[A]

    0.68/0.390.78/0.45

  • 8/10/2019 Axial_fans_2007_EN.pdf

    33/435

    33

    Motor protection: Without TOP, TOP wired internally Cable exit: Variable Protection class: I Product conforming to standards: EN 60335-1, also CE

    Approvals: CCC

    B

    BA

    Withoutattachments

    With guard grillefor full nozzle

    With fullround nozzle

    With guard grillefor short nozzle

    "V" A2D 300-AP02 -01 A2D 300-AP02 -02

    W2D300-CP02 -30W2D300-CP02 -31

    S2D 300-BP02 -30S2D 300-BP02 -31

    S2D 300-AP02 -30S2D 300-AP02 -31"A"

    "V" A2E 300-AP02 -01 A2E 300-AP02 -02

    W2E 300-CP02 -30W2E 300-CP02 -31

    S2E 300-BP02 -30S2E 300-BP02 -31

    S2E 300-AP02 -30S2E 300-AP02 -31"A"

    D i r e c t i o n o

    f a i r

    f l o w

    B

    1000 2000 3000

    0 500 1500 [CFM]1000 2000

    [ P a ]

    40

    80

    120

    160

    200

    0 , 2

    0 , 4

    0 , 6

    [ i n H

    2 O ]

    [m3 /h]

    6 0 Hz50 Hz

    1

    2

    B

    B

    26802560

    252290

    1.111.27

    1

    2

    Curves

    "V"/"A" "V"/"A" "V"/"A" "V"/"A"

    Terminal boxp.381

    Wall ringp. 372 f.

    Guard grillep. 362 f.

    Drawingsp. 34 f.

    Capacitorp. 382 f.

    Electr. connectionsp. 416 f.

    n[rpm]

    P1[W]

    I[A]

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

  • 8/10/2019 Axial_fans_2007_EN.pdf

    34/435

    34

    AC axial fans2-poleS series, 300, drawings of directions of air flow "V" and "A"

    +

    104

    685

    450 20

    7 5

    5

    30 3

    0-

    2 900,2

    1 0 2

    2 9 8 2

    3 7

    38 3

    M4M6

    4 x 9 0

    Without attachments Type

    A2D 300-AP02 -01 A2D 300-AP02 -02 A2E 300-AP02 -01 A2E 300-AP02 -02

    "V""A""V""A"

    0

    3 8 0

    3 2 6

    3 9 7

    1180

    6 x 6 0

    9

    1 5

    With full round nozzle Type

    W2D300-CP02 -30W2D300-CP02 -31W2E 300-CP02 -30W2E 300-CP02 -31

    "V""A""V""A"

    3 6 0

    50

    6,5

    With guard grille for full nozzle Type

    S2D 300-BP02 -30

    S2D 300-BP02 -31S2E 300-BP02 -30S2E 300-BP02 -31

    "V"

    "A""V""A"

    "V""A"

    "V""A"

    "V""A"

    Depth of screwmax. 10 mm

    Brass lead tips

  • 8/10/2019 Axial_fans_2007_EN.pdf

    35/435

    35

    505

    0

    3 6 0

    6,5

    1854

    3 2 4

    With guard grille for short nozzle Type

    S2D 300-AP02 -30S2D 300-AP02 -31S2E 300-AP02 -30S2E 300-AP02 -31

    "V""A""V""A"

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    "V""A"

  • 8/10/2019 Axial_fans_2007_EN.pdf

    36/435

    36

    AC axial fans4-poleS series, 300

    Material: Guard grille: Steel, phosphated and coated in black plasticWall ring: Sheet steel, pre-galvanised and coated in black plasticBlades: Sheet steel, coated in black Rotor: Coated in black

    Number of blades: 5 Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"counter-clockwise, seen on rotor

    Type of protection: IP 44 Insulation class: "B" Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request Condensate discharges: Rotor-side Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings

    Nominal data

    Type Motor

    *4D 300(1) M4D068-CF

    *4E 300 M4E 068-CF

    subject to alterations

    500 1000 1500

    0 250 500 1000 [CFM]750

    [ P a ]

    20

    40

    60

    80

    100

    0 , 1

    0 , 2

    0 , 3

    [ i n H

    2 O ]

    [m3 /h]

    60 Hz50 Hz

    1

    2

    A

    Curves

    13501260

    n[rpm]

    P1[W]

    6688

    A

    A

    1

    2

    VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg p. 416 f.

    C1)/C2)3~ 230/400 50 1860 1370 60 0.29/0.17 57 90 -25 to +45

    3~ 230/400 60 2080 1540 75 0.26/0.15 60 60 -25 to +401~ 230 50 1740 1400 68 0.30 2.0 /400 59 80 -25 to +601~ 230 60 2040 1630 92 0.41 2.0 /400 63 70 -25 to +45

    A

    A1)1.9

    1.9

    B

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s w i t h o u t

    a t t a c h m

    e n t s

    E l e c t r . c o n n e c t i o n

    (1) 230 VAC / 400 VAC Y

    I[A]

    0.29/0.170.33/0.19

  • 8/10/2019 Axial_fans_2007_EN.pdf

    37/435

    37

    Motor protection: Without TOP, TOP wired internally Cable exit: Axial, variable Protection class: I Product conforming to standards: EN 60335-1, also CE

    Approvals: CCC; also GOSTB

    B

    BA

    BA

    Withoutattachments

    With guard grillefor full nozzle

    With fullround nozzle

    With guard grillefor short nozzle

    "V" A4D 300-AP28 -01 A4D 300-AP28 -02

    W4D300-CP28 -30W4D300-CP28 -31

    S4D 300-BP28 -30S4D 300-BP28 -31

    S4D 300-AP28 -30S4D 300-AP28 -31"A"

    "V" A4E 300-AP26 -01 A4E 300-AP26 -02

    W4E 300-CP26 -30W4E 300-CP26 -31

    S4E 300-BP26 -30S4E 300-BP26 -31

    S4E 300-AP26 -30S4E 300-AP26 -31"A"

    D i r e c t i o n o

    f a i r

    f l o w

    500 1000 1500

    0 250 500 1000 [CFM]750

    [ P a ]

    20

    40

    60

    80

    100

    0 , 1

    0 , 2

    0 , 3

    [ i n H

    2 O ]

    [m3 /h]

    60 Hz50 Hz

    1

    2

    B

    B

    B

    13901290

    7288

    0.320.39

    1

    2

    Curves

    "V"/"A" "V"/"A" "V"/"A" "V"/"A"

    Terminal boxp.381

    Wall ringp. 372 f.

    Guard grillep. 362 f.

    Drawingsp. 38 f.

    Capacitorp. 382 f.

    Electr. connectionsp. 416 f.

    n[rpm]

    P1[W]

    I[A]

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

  • 8/10/2019 Axial_fans_2007_EN.pdf

    38/435

    38

    AC axial fans4-poleS series, 300, drawings of directions of air flow "V" and "A"

    +

    73

    685

    450 20

    2 7

    2

    c 3

    0-

    2 580,2

    9 2

    3 0 0

    - 2

    2 7

    60 3

    M4M4

    4 x 9 0

    Without attachments Type c A4D 300-AP28 -01 A4D 300-AP28 -02 A4E 300-AP26 -01 A4E 300-AP26 -02

    13.0-7.013.0-7.0

    "V""A""V""A"

    k

    3 8 0

    3 2 6

    3 9 7

    1180

    6 x 6 0

    9

    1 5

    With full round nozzle Type k W4D300-CP28 -30W4D300-CP28 -31W4E 300-CP26 -30W4E 300-CP26 -31

    0.030.00.0

    30.0

    "V""A""V""A"

    3 6 0

    4k

    4,5

    With guard grille for full nozzle Type k S4D 300-BP28 -30

    S4D 300-BP28 -31S4E 300-BP26 -30S4E 300-BP26 -31

    0.0

    30.00.0

    30.0

    "V"

    "A""V""A"

    "V""A"

    "V""A"

    "V""A"

    Depth of screwmax. 5 mm

    Brass lead tips

  • 8/10/2019 Axial_fans_2007_EN.pdf

    39/435

    39

    504

    k

    3 6 0

    4,5

    3 2 9

    , 5

    uv

    With guard grille for short nozzle Type k S4D 300-AP28 -30S4D 300-AP28 -31S4E 300-AP26 -30S4E 300-AP26 -31

    0.030.00.0

    30.0

    u

    23.029.023.029.0

    v

    23.049.023.049.0

    "V""A""V""A"

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

    "V""A"

  • 8/10/2019 Axial_fans_2007_EN.pdf

    40/435

    40

    AC axial fansS series, 315

    Material: Guard grille: Steel, phosphated and coated in black plasticWall ring: Sheet steel, pre-galvanised and coated in black plasticBlades: Sheet steel, coated in black Rotor: Coated in black

    Number of blades: 5 Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"counter-clockwise, seen on rotor

    Type of protection: IP 44 Insulation class: "B" Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request Condensate discharges: Rotor-side Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings

    Nominal data

    Type Motor

    *4D 315(1) M4D068-DF

    *4E 315 M4E 068-DF

    *6E 315 M6E 068-DF

    subject to alterations

    600 1200 1800 2400

    0 250 1000 1250 [CFM]500 750 1500

    [ P a ]

    20

    40

    60

    80

    100

    120

    0 , 1

    0 , 2

    0 , 4

    [ i n H

    2 O ]

    0 , 3

    [m3 /h]

    6 0 Hz50 Hz

    2

    1

    A

    Curves

    14001380

    n[rpm]

    P1[W]

    90103

    A

    A

    1

    2

    Drawingsp. 42 f.

    VAC Hz m3 /h rpm W A F/VDB dB(A) Pa C kg p. 416 f.

    C1)/C2)3~ 230/400 50 2450 1400 85 0.45/0.26 60 120 -25 to +55

    3~ 230/400 60 2810 1620 110 0.42/0.24 64 120 -25 to +551~ 230 50 2440 1410 102 0.52 4.0 /400 59 120 -25 to +551~ 230 60 2840 1650 120 0.53 4.0 /400 64 120 -25 to +55

    A

    A1)2.4

    2.4

    B

    1~ 230 50 1650 950 65 0.33 2.0 /400 51 70 -25 to +501~ 230 60 1950 1120 68 0.30 2.0 /450 55 80 -25 to +60 A1)2.4C

    C u r v e

    N o m i n a l v o l t a g e

    F r e q u e n

    c y

    A i r

    f l o w

    S p e e d / r p m

    P o w e r i n p u t

    C u r r e n t

    d r a w

    C a p a c i t o r

    S o u n d p r e s s u r e l e v e l

    M a x . o p e r a t i v e r a n g e

    P e r m

    . a m b

    . t e m p

    .

    M a s s w i t h o u t

    a t t a c h m

    e n t s

    E l e c t r . c o n n e c t i o n

    (1) 230 VAC / 400 VAC Y

    I[A]

    0.45/0.260.47/0.27

  • 8/10/2019 Axial_fans_2007_EN.pdf

    41/435

    41

    Motor protection: Without TOP, TOP wired internally Cable exit: Axial Protection class: I Product conforming to standards: EN 60335-1, also CE

    Approvals: CCC; also GOSTA

    CB

    CBA

    Withoutattachments

    With guard grillefor full nozzle

    With fullround nozzle

    With guard grillefor short nozzle

    "V" A4D 315-AP10 -01 A4D 315-AP10 -02

    W4D315-CP10 -30W4D315-CP10 -31

    S4D 315-BP10 -30S4D 315-BP10 -31

    S4D 315-AP10 -30S4D 315-AP10 -31"A"

    "V" A4E 315-AP18 -01 A4E 315-AP18 -02

    W4E 315-CP18 -30W4E 315-CP18 -31

    S4E 315-BP18 -30S4E 315-BP18 -31

    S4E 315-AP18 -30S4E 315-AP18 -31"A"

    "V" A6E 315-AP02 -01 A6E 315-AP02 -02

    W6E 315-CP02 -30W6E 315-CP02 -31

    S6E 315-BP02 -30S6E 315-BP02 -31

    S6E 315-AP02 -30S6E 315-AP02 -31"A"

    D i r e c t i o n o

    f a i r

    f l o w

    600 1200 1800 2400

    0 250 1000 1250 [CFM]500 750 1500

    [ P a ]

    20

    40

    60

    80

    100

    120

    0 , 1

    0 , 2

    0 , 3

    [ i n H

    2 O ]

    0 , 4

    [m3 /h]

    60 Hz50 Hz

    2

    2

    1

    1

    B

    C

    B

    C

    B

    C

    14001380

    945930

    108120

    6366

    0.540.57

    0.330.33

    1

    2

    2

    1

    Curves

    "V"/"A" "V"/"A" "V"/"A" "V"/"A"In-line duct fan

    W4D315-IP10 -01

    W4E 315-IP18 -01

    "V"

    Terminal boxp.381

    Wall ringp. 372 f.

    Streamerp.371

    Guard grillep. 362 f.

    Capacitorp. 382 f.

    Electr. connectionsp. 416 f.

    n[rpm]

    P1[W]

    I[A]

    G e n e r a l

    i n f o r m a t i o n

    A C a x

    i a l

    f a n s

    A C a x i a l

    S s e r i e s

    A C a x i a l

    K s e r i e s

    A C a x i a l

    A s e r

    i e s

    E C a x

    i a l

    f a n s

    E C a x i a l

    S s e r i e s

    Q - m

    o t o r

    E S M

    E C

    - S Y

    S T E M S

    A c c e s s o r i e s

    T e c h n o l o g y

    C o n t a c t s

  • 8/10/2019 Axial_fans_2007_EN.pdf

    42/435

    42

    AC axial fansS series, 315, drawings of directions of air flow "V" and "A"

    83

    +

    85

    2045085

    2

    2 7

    6

    - 0

    3c

    2 0,258

    M4

    2

    3 1 2

    9 2

    2 7