10003 UK 10-2004

Technical Information: TEMPUS III

TEMPUS III

Page 2: Azkoyen Tempus III Timer Manual

General content

5 a 7

8 a 32

6 6 a 7

8 9 9 10 11 11 12 13 13 14 14 14 14 15 1617 a 18 19 19 20 20 21 21 2223 a 24 25 26 2727 a 28 29 3031 a 32

1. Introduction ..............................................................................................

2. Physical and technical characteristics ................................................

1.1. What is a Tempus III? .............................................................................. 1.2. Where can you use a Tempus III? .....................................................

2.1. Electrical characteristics .......................................................................... 2.2. Azkoyen NN6 selector ............................................................................. 2.2.1. Electrical specifications of the NN6 selector ................................... 2.2.2. Connection ..................................................................................... 2.2.3. Mechanical specifications .............................................................. 2.2.4. Operating conditions ...................................................................... 2.2.5. Component description and operation ........................................... 2.2.5.1. Terminal strip and rockers ...................................................... 2.2.5.2. Photocells of the housing and of the hinge ............................ 2.2.5.3. Cores ..................................................................................... 2.2.5.4. Anti-return system .................................................................. 2.2.5.5. Obturator unit.......................................................................... 2.2.5.6. Output photocell ..................................................................... 2.2.6. Placing the NN6 selector in the Tempus III .................................... 2.2.7. Cleaning and maintenance of the NN6 selector ............................ 2.3. Control card + power supply ........................................................... 2.3.1. Test and Control pushbuttons ........................................................ 2.3.2. Output relays ................................................................................. 2.3.3. Consumption sensor ..................................................................... 2.3.4. JP1 Connector................................................................................ 2.3.5. JP2 Connector................................................................................ 2.3.6. JP3 Connector................................................................................ 2.3.7. JP4 Connector................................................................................ 2.3.8. JP5 Connector......................................................................... 2.4. Display card ........................................................................................... 2.5. Cabinet ................................................................................................... 2.6. Coin bin .................................................................................................. 2.7. Locking system .............................................................................. 2.8. Coin entrance and recovery system....................................................... 2.9. Connection diagram .............................................................................. 2.10. Range of models and physical measurements ...........................

- 2 - PAYMENT MEANSOYK ENZA

Page 3: Azkoyen Tempus III Timer Manual

3. Programming: Accounting and operating modes .............................

4. Accessories ..........................................................................................

3.1. Accounting ............................................................................................. 3.2. Applications of the different operating modes ........................................ 3.3. Timer operating mode A ................................................................ 3.3.1. Description and general characteristics ......................................... 3.3.2. Operating characteristics ....................................................... 3.3.3. Programming ......................................................................... 3.3.4. Error messages ............................................................................. 3.4. Timer operating mode B ................................................................ 3.4.1. Description and general characteristics ......................................... 3.4.2. Operating characteristics ...................................................... 3.4.3. Programming ......................................................................... 3.4.4. Error messages .............................................................................. 3.5. Starter operating mode ................................................................. 3.5.1. Description and general characteristics ......................................... 3.5.2. Operating characteristics ...................................................... 3.5.3. Programming ......................................................................... 3.5.4. Error messages .............................................................................. 3.6. Photocopier control operating mode A ........................................... 3.6.1. Description and general characteristics ......................................... 3.6.2. Operating characteristics ....................................................... 3.6.3. Programming ......................................................................... 3.6.4. Error messages ............................................................................. 3.7. Photocopier control operating mode B .......................................... 3.7.1. Description and general characteristics ......................................... 3.7.2. Operation characteristics ....................................................... 3.7.3. Programming ......................................................................... 3.7.4. Error messages .............................................................................

4.1. Clock card .............................................................................................. 4.2. Tempus III Omega unit ...........................................................................

33 a 71

72 a 73

33 3435 a 45 3536 a 3839 a 44 4546 a 54 4647 a 4849 a 53 5455 a 59 5556 a 5757 a 58 5960 a 65 6061 a 6263 a 64 6566 a 71 6667 a 6869 a 70 71

72 73

TEMPUS III - 3 -OYK ENZA

Page 4: Azkoyen Tempus III Timer Manual

1. IntroductionThe technical information related to the Tempus III series has been designed to

inform you about its technical characteristics, its operation principle, the elements that comprise a timer, the models that currently make up the series and its many practical uses.

TEMPUS III - 5 -

Long Tempus III

Short Tempus III

Fitted Tempus III

OYK ENZA

Page 5: Azkoyen Tempus III Timer Manual

1.1. What is a Tempus III

1.2. Where can you use a Tempus III

A Tempus III is an electronic apparatus that sells time and impulses. The practical applications of a Tempus III are the on/off control of different apparatus such as: control of televisions and carwashes in time sale mode and photocopiers in impulse sale mode.

The Tempus III controls the external mechanisms that it regulates by activating and deactivating relays, which will operate in one way or another depending on the configuration and programming of the apparatus. These can respond both to internal signals (credits, clock period, etc.) and to external signals (consumption, activation, input, etc.) so it has countless applications.

The Tempus III timers have the following features:

Great programming versatility, providing infinite uses.

Admission of any type of coins of legal tender. Use the selector AZKOYEN NN6.

Display showing the time, number of services or credits available.

Accounting of the amount in pesetas that the apparatus has received (without resetting)

Consumption detector (adjustable) in output making it possible to stop the time when there is no charge.

There are many and varied applications for the Tempus III timers. Below we point out the most representative:

Tempus III to control the lighting of tennis courts and sports centres.

- 6 - PAYMENT MEANSOYK ENZA

Page 6: Azkoyen Tempus III Timer Manual

Tempus III to control photocopiers.

Tempus III to control televisions.

Tempus III to control children's amusement arcades.

Tempus III to control carwashes and vacuum-cleaning systems

Tempus III to control computers in Cybercafés..

TEMPUS III - 7 -OYK ENZA

Page 7: Azkoyen Tempus III Timer Manual

2. Physical and technical characteristics

2.1. Electrical characteristics

In this section the elements that comprise the Tempus III are studied in detail, as well as how they are connected and their electrical specifications, the construction materials, programming, operating modes and the different models that form part of the series.

Supply voltage 220Vac ± 10% 50 Hz.

Maximum primary intensity 50 mA.

Maximum intensity controllable by the relay contacts 6 A (protected by fuse).

- 8 - PAYMENT MEANSOYK ENZA

Page 8: Azkoyen Tempus III Timer Manual

2.2.1. Electrical specifications of the NN6 selector

The supply voltage required for the NN6 selector to operate correctly is 12 Vdc, which is supplied through pins 1 and 2 of connector Jp3:

2.2. Azkoyen NN6 Selector

The NN6 selector model is responsible for identifying the coins inserted into the Tempus III. It is able to admit 15 different coin models.

T h e N N 6 i s r e s p o n s i b l e f o r controlling the Tempus III with the control card + power supply and its operating mode depending on this.

TEMPUS III - 9 -OYK ENZA

Supply voltage

12Vdcmaximum: 15Vdcminimum: 10Vdc

Mean consumption

Coin validation: 50mA.

Acceptance coil: 280mA.

Page 9: Azkoyen Tempus III Timer Manual

JP3: 14 -way connec to r wh ich permits the connection of the selector with the control card + power supply by means of the selector bundle "L"-

SW: Four microswitches that are used to select the operating mode of the appliance.

SW4 SW3 SW2 SW1

OFF OFF OFF ON Timer A

ON ON OFF OFF Timer B

OFF OFF ON OFF

OFF ON OFF OFF

ON OFF OFF OFF

OPERATING MODE

Starter

Photocopier control A

Photocopier control B

2.2.2. Connection

In order for the selector to work correctly the operating mode selection microswitches must be in the proper position and the connector that communicates it with the control card + power supply must be correctly connected:

JP3

Reference: ZT43206390-0

Selector bundle "L”

Microswitches

The operating mode must always be changed with the Tempus III switched off.

- 10 - PAYMENT MEANSOYK ENZA

Page 10: Azkoyen Tempus III Timer Manual

2.2.3. Mechanical specifications

Diameter: Thickness:

Minimum 17.5mm 1.2mm

Maximum 32mm 3.3mm

TEMPUS III - 11 -

As described above the selector admits all coins of legal tender and has the capacity to validate up to 15 different types. It can be used for coins of any country after this has been factory-programmed. The dimensions of the possible coins admitted by the selector must be between the margins specified in the following table:

2.2.4. Operating conditions

To achieve optimum operation of the apparatus a series of basic requirements must be satisfied with respect to where the Tempus III is installed and how it is fitted. These are the following:

Inclination margin: 3º in all the axes.

Temperature margin: Operation: +5 to + 55ºC.Storage: -25 to +70ºC

Humidity margin: Maximum 95% (Relative humidity without condensation).

OYK ENZA

Page 11: Azkoyen Tempus III Timer Manual

2.2.5. Component operation and description

The selector operates by measuring a series of typical parameters of each coin, which will determine whether it is admitted or rejected. The diameter of the coin is measured by means of two photodiodes and two phototransistors and the electrical conductivity and magnetic field permeability are determined using two coils with ferrite cores (which are very sensitive to magnetic variations).

Ferrite core Photocells

Once all the parameters have been obtained, these are compared with the ones that have been programmed earlier in the selector microprocessor memory during one of the manufacturing phases. This programming is carried out using a set of coins of legal tender that include all the existing models in circulation. Thus the selector will determine the validity or nullity of the coin inserted and will direct it towards the coin bin or towards the return box.

The main elements that comprise the NN6 selector and which are essential for its operation are described below:

- 12 - PAYMENT MEANSOYK ENZA

Page 12: Azkoyen Tempus III Timer Manual

2.2.5.1. Terminal strip and rockers

2.2.5.2. Photocells of the housing and the hinge

The aim of the terminal strip and the input rocker is to dampen the free fall of the coin, slowing down its entry, thus preventing it from entering the selector in an irregular fashion, bouncing, and achieving a suitable uniform and rotation movement on the plastic bar situated next to the terminal strip.

The lower rocker is fitted to stabilise the coin speed coming out of the selector, slowing it down and getting it to come out in the most adequate fashion.

TEMPUS III - 13 -

Input rocker

Outlet rocker

Terminal strip

Plastic bar

Photocells

Two photodiodes are located in the hinge, which are perfectly aligned with the two phototransistors placed in the housing. The photodiodes emit an infrared light beam, which the phototransistors receive. When the coin enters the selector it crosses and cuts the infrared light beam. Depending on how long it takes for the coin to cut both light beams, the selector is able to determine the diameter of the coin in question.

OYK ENZA

Page 13: Azkoyen Tempus III Timer Manual

2.2.5.3. Ferrite cores

2.2.5.4. Anti-return system

2.2.5.5. Obturator unit

The selector has two face-to-face coils with ferrite core. One is installed in the hinge and the other in the housing. These ferrite cores create a magnetic field, which, when crossed by a coin, causes variations in the frequency, permitting the selector to measure the electrical conductivity and magnetic field permeability.

The function of the anti-return system is to prevent the coin from re-entering the selector once it has been admitted. This system prevents frauds produced by attaching a thread to the coin.

This element is used to direct the coins to the right outlet. It is comprised of a coil, which is activated when the coins are admitted, freeing the outlet towards the coin bin and which remains inactive when it rejects them so that they come out towards the recovery box.

2.2.5.6. Outlet photocell

.

The valid coins that have come out correctly, cut the infrared light beam established between the photodiode and the phototransistor located on the lower part of the selector, in the outlet area for admitted coins. This is exactly when the selector determines the authenticity of the coin.

Ferrite cores

Anti-return system

Coil

Coin outlet Photocell

- 14 - PAYMENT MEANSOYK ENZA

Page 14: Azkoyen Tempus III Timer Manual

2.2.6. Placing the selector NN6 in Tempus III

The NN6 selector is secured to the Tempus III through its side pivots. Two of these pivots fit perfectly into the holes of the metal housing, and in order to totally secure the selector, a third pivot is anchored in the retainer (flexible to facilitate later removal).

Flexible retainer

Flexible retainer

Reference: ZT11008840-1

Anchorage of the selector

TEMPUS III - 15 -OYK ENZA

Page 15: Azkoyen Tempus III Timer Manual

2.2.7. Cleaning and maintenance of the NN6 selector

The only maintenance that the NN6 selector requires depends on how soiled the coins are, as this can obstruct its optical elements.

If the coins have to be inserted several times before being accepted this is an unmistakable sign that the selector has accumulated dirt on its photodiodes or phototransistors and has to be cleaned.

The cleaning must be done with 96º ethyl alcohol. Products containing benzene hydrocarbons must not be used, as they would produce a rapid degradation of the plastic, which in turn would cause irreparable damage to the selector.

Before cleaning, the two parts of the selector, housing and hinge, must be separated it. Then, using a brush (fine vegetable fibre bristles, never metal ones) impregnated in alcohol, clean the areas where the photodiodes and phototransistors are located, in order to completely clean the holes where these are located.

After the cleaning process, in order for the selector to operate correctly, it must be left to dry at room temperature for twelve hours (a household dryer can also be used for 10 minutes).

- 16 - PAYMENT MEANSOYK ENZA

Page 16: Azkoyen Tempus III Timer Manual

2.3. Control card + power supplyThe control card + power supply is responsible for receiving and transmitting data

from the external device to the selector and vice-versa. It includes the power supply (transformer, rectifier, stabiliser and filter), which is used to supply the selector, the display card and clock card (an accessory used for applications where a clock in real time is required). It has several connectors for its relative connection. The control relays of the outlet device and the accounting and programming control pushbuttons are installed in it, as well as the fuses necessary to protect all the elements of the Tempus III.

TEMPUS III - 17 -

Transformer

Led diode

Potentiometer

Fuses

TEST

JP5 JP2 JP3

JP4

JP1

CONT

K1

K2

To achieve absolute control of the electric charge this card has been provided with an adjustable consumption sensor, which enables the time discount to be stopped if the outside electrical charge has been stopped or disconnected.

OYK ENZA

Page 17: Azkoyen Tempus III Timer Manual

- 18 - PAYMENT MEANS

The card is secured to the cabinet with four plastic supports, type RICHCO LCBS-8N, which keep it perfectly secure.

For greater security the control card + power supply includes the protection housing.

Richco support

Reference: ZT09700770-0

Protection housing

Reference: ZT11013831-0

OYK ENZA

Page 18: Azkoyen Tempus III Timer Manual

2.3.1. Cont. and Test Pushbuttons

2.3.2. Output relays

The Cont. and Test pushbuttons are used to view the accounting on the display and to access the apparatus programming. They can be used to select the functions within the programming menu and to enter them to modify them or validate them.

The K1 relay is used to control the charge as with its contacts it connects and disconnects the supply voltage to the connector pins (to the charge) and it is able to control up to 6A. A consumption sensor has been installed on this relay, which enables a pause to be made in the time discount when it detects that there is no consumption in the outlet. It has a 6A protection fuse.

TEST CONT

The K2 re lay i s a l so a cont ro l re lay wi th the contacts towards the outside, able to control up to 6A and protected with a fuse. B u t , u n l i k e t h e K 1 t h e r e i s n o potent ia l in i ts termina ls . The connection or disconnection of its t e r m i n a l s w i l l d e p e n d o n t h e operating mode programmed in the selector microswitches and on the application for which it is going to be used.

K2

K1

TEMPUS III - 19 -OYK ENZA

Page 19: Azkoyen Tempus III Timer Manual

2.3.3. Consumption sensor

2.3.4. JP1 Connector

The consumption sensor is used to stop the time discount when the system detects that the charge is not in operation. It operates with the charge connected to the K1 relay and it can be adjusted by means of a potentiometer.

In order for the consumption sensor to operate it must be enabled by programming.

If, once the consumption sensor has been enabled, the charge apparatus does not work correctly; it will have to be adjusted. To do this, it must be taken into account that the luminous indicator (Led diode) of the control card + power supply must stay off when the charge is not activated and must light up when this is connected. If it does not do so, the consumption sensor must be adjusted with potent iometer R16 (us ing a f i ne f l a t screwdriver) until the luminous indicator behaves as described.

Led

JP1 is a 14-way connector used to connect the control card + power supply and the coin selector.

JP1 CONNECTOR

Connection to the selector

Potentiometer

- 20 - PAYMENT MEANSOYK ENZA

Page 20: Azkoyen Tempus III Timer Manual

2.3.5. JP2 Connector

2.3.6. JP3 Connector

The display card is connected to the 4-way connector JP2 with the timer display bundle. If the apparatus requires the clock card in order to operate, the latter must be coupled to JP2 so the timer display bundle of the display card must be connected to the clock card (to the only connector that this card has). See accessory section.

Jp2 CONNECTOR

Connection to the display

JP3 CONNECTOR

Pin Comment

1 Outside input

2 GND (ground)

JP3 is used in special applications where an outside input of the device controlled (charge) must be used. It is also used to access different programming menus.

TEMPUS III - 21 -OYK ENZA

Page 21: Azkoyen Tempus III Timer Manual

2.3.7. JP4 ConnectorThe main input (pins 7 and 8) and the charge output (pins 5 and 6) must be

connected to connector, JP4. The outlet for a possible input from the charge apparatus and the contacts of relay K2 (for special uses) is also located.

When K1 relay is activated pin 5 connects to pin 7 so the power outlet for the outside apparatus (charge) must be taken from pins 5 and 6 of connector JP4.

There is no potential in pins 1 and 2 and when K2 relay is activated, it short-circuits these pins.

The circuit of each relay contains a 6A protection fuse in series.

JP4 CONNECTOR

Pin Comment

1 Contact of K2 relay normally open

2 Contact of K2 relay normally open

3 Outside input

4 GND (ground)

5 Contact of K1 relay normally open

6 Mains supply input (of pin 8)

7 Mains supply input

8 Mains supply input

Fuses

1 2 3 4

JP4

5 6 7 8

Control card + power supply

- 22 - PAYMENT MEANS

To make the JP4 connection the 8-way Molex connector is supplied with its relative Molex terminals

Molex connector

Reference: ZT03803280-0

Reference: ZT03900590-0

Molex terminal

OYK ENZA

Page 22: Azkoyen Tempus III Timer Manual

2.3.8. JP5 Connector

Three-way connector used for possible outside inputs. The maximum admissible input intensity through pin 1 is 50 mA

JP5 CONNECTOR

Pin Comment

1 NPN transistor open collector output

2 GND (ground)

3 Outside input

Control card + power supply

Two models of control card + power supply can be installed. The only difference is that one model has special protection against water and humidity, which we called tropicalised, and the other being non- tropicalised depending on the model or application of the apparatus.

The references are as follows

Reference: ZT43304710-0

Reference: ZT43304711-0

Tropicalised

Non Tropicalised

TEMPUS III - 23 -OYK ENZA

Page 23: Azkoyen Tempus III Timer Manual

Electrical wiring diagram of the control card + power supply

- 24 - PAYMENT MEANSOYK ENZA

Page 24: Azkoyen Tempus III Timer Manual

2.4. Display cardThe d isp lay ca rd has f ou r 7 -

segment BCD displays, which are the four digits. 00.00 is displayed on them when the outside charge is not in operation. When coins are inserted in the Tempus III the time, number of services or remaining credit for the end of the service are shown.

Display card

Display glass

Timer display bundle

Reference: ZT43302960-0

Reference: ZT43302961-0

Reference: ZT11000071-0

Reference: ZT43204860-0

The display card has a connector used to join it to the control card + power supply by means of the t imer display bundle.

The display card is secured inside the metal housing of the Tempus III with two screws and to correctly view the displays, the display glass is fitted into the cabinet.

There are two models of display card, the only difference being that one has protection against water and humidity. So, there is a tropicalised one and a non-tropicalised one depending on the model and application.

TEMPUS III - 25 -

Tropicalised

Non-tropicalised

OYK ENZA

Page 25: Azkoyen Tempus III Timer Manual

2.5. CabinetThere are three different cabinet models; these are the long cabinet subunit, the

short cabinet subunit and the short cabinet subunit with side anchorage boreholes:

Long cabinet subunit Short cabinet subunit Short cabinet subunit

Front plate

Front plate

Reference: ZT42000771-4 Reference: ZT42001091-2

Reference: ZT11008831-0

To secure the metal housing to the cabinet the so-called front plate has been designed, which acting as a trim, and with the Azkoyen symbol engraved on it, is coupled from the outside with four screws, fastening the support or metal housing to it.

Reference: ZT42000971-3

- 26 - PAYMENT MEANSOYK ENZA

Page 26: Azkoyen Tempus III Timer Manual

2.6. Coin bin

2.7. Locking system

The Tempus III has two different types of coin bins, the long coin bin subunit used for models with long cabinet and which has the capacity to house up to 600 100-peseta coins, and the coin bin subunit used for models with short cabinet and which can store 200 100-peseta coins at the most.

Long coin bin Short coin bin

Reference: ZT42910341-0 Reference: ZT42911630-0

The locking system is based on a STS 625.008 lock, which, when turned, moves a washer that is fixed to two rods, one of which moves upwards and the other downwards fitting into their relative places. Thus the door is perfectly anchored to the cabinet making the Tempus III extremely secure against possible attempts of theft.

TEMPUS III - 27 -

Lock

OYK ENZA

Page 27: Azkoyen Tempus III Timer Manual

Lock STS 625.008

Reference: ZT08500380-0

Reference: ZT39005261-0

Reference: ZT39006231-0

Reference: ZT39005271-0

Reference: ZT31039581-0

Upper rod Long lower rod Lower rod

Rod washer

- 28 - PAYMENT MEANSOYK ENZA

Page 28: Azkoyen Tempus III Timer Manual

52,1 mm.

66 mm.5

2,1

mm

.5

1,4

mm

.

66

,5 m

m.

10

6 m

m.

52,2 mm.

2.8. Coin entry and recovery system The coin entry system is comprised of the upper

frame and the recovery pushbutton (called entry coin-guide), which are visible from the outside. The Tempus III has another coin-guide on the inside, which connects the recovery pushbutton with the selector coin entry.

The recovery system is based on a mechanical movement. When the recovery pushbutton (entry coin-guide) is activated it applies a rocker, which in turn moves the selector recovery lever and causes the hinge to open. Thus the coin comes out and falls into the recovery box.

Reference: ZC11002271-0

Reference: ZC11001761-0

Coin-guide

Reference: ZC11004101-0

Upper frame Entry coin-guide

Recovery system activated Opening of the selector hinge

Pushbutton

Recovery system on stand-bySelector

RockerRocker

TEMPUS III - 29 -

Reference: ZC11002271-0

Unit "U”

OYK ENZA

Page 29: Azkoyen Tempus III Timer Manual

2.9. Connection diagram

- 30 - PAYMENT MEANSOYK ENZA

Page 30: Azkoyen Tempus III Timer Manual

2.10. Range of models and physical measurements

TEMPUS III - 31 -

8 m

m.

18

5 m

m.

77 mm.120 mm.110 mm.

38

8 m

m.

TEMPUS 90716

Reference Name

90716 Tempus III Long 90763 Tempus III Short 90727 Tempus III Fitted 90793 Tempus III Short for outdoors (with tropicalised cards) 90839 Tempus III Short with side boreholes

OYK ENZA

Page 31: Azkoyen Tempus III Timer Manual

8 m

m.

18

5 m

m.

77 mm.

28

8 m

m.

110 mm. 120 mm.

TEMPUS 90763, TEMPUS 90793, TEMPUS 90839

FITTED TEMPUS 90727

59 mm.

85 mm.

101 mm.

27

4 m

m.

- 32 - PAYMENT MEANSOYK ENZA

Page 32: Azkoyen Tempus III Timer Manual

3. Programming: Accounting and operating modes

The different operating modes of the Tempus III are studied in detail in this chapter, as well as the programming and practical applications depending on the operating mode configured. The way to access the accounting of the apparatus is explained.

3.1. AccountingThe accounting of the Tempus III is viewed quickly and simply by activating the

CONT pushbutton, located on the control card + power supply. Once depressed, the display will show the amount taken divided by one hundred:

Accounting on display = Takings 100

So, in order to know how much has been taken, the figure shown on the display must be multiplied by 100. The amount obtained will be the total accounting of the apparatus. For example:

Message on the display = 1873Amount taken = 187.300 pesetas (with a margin of error of +95 ptas. - 0 ptas.)-

CONT

TEMPUS III - 33 -OYK ENZA

Page 33: Azkoyen Tempus III Timer Manual

OPERATING MODE APPLICATIONS

Television control.

Computer control in cybercafes.

Control of pressurised hoses for carwashes. Timer A

Vacuum-cleaner control.

Sports areas lighting control.

Control of camping site appliances such as: Washing-machines, dryers, showers, etc.

Timer B Control of children's amusement arcades.

Control of carwash tunnels. Starter

Control of UV sunbeds

Photocopier control A Control of photocopiers

Control of photocopiers Photocopier control B

Control of vending machines (coffee-machines, etc.)

3.2. Applications of the different operating modes

The following table gives some of the most common applications of the Tempus III linking them with the different operating modes so that, depending on your specific application, you can select the most suitable configuration and programming according to your needs:

- 34 - PAYMENT MEANSOYK ENZA

Page 34: Azkoyen Tempus III Timer Manual

3.3. Timer operating mode A

3.3.1. Description and general characteristics

The timer operating mode A comprises the sale of a time

period of between 1 minute and 100 hours (99 hours and 59 minutes).

This operating mode of the Tempus III is used for applications where the services require times of several minutes or even hours. Therefore, the Tempus III must be programmed with the value of the price/hour of the service and it will be responsible for supplying the time corresponding to the credit inserted, providing this is the same as or greater than the minimum coin insertion (which is a programmable amount).

When the credit reaches the minimum coin insertion value programmed, the timer activates relays K1 and K2 simultaneously and they stay activated until the time granted has been totally discounted.

The main characteristics, which indicate the functionality of this working mode, are:

Unitary inhibition of all the coins, programmable by the user.

Direct viewing of the accounting.

Programming the luminous intensity of the display.

Possibility of programming two different price tariffs, which can be changed depending on the time or through an outside input. Display of the time remaining, making the discount every minute with the last minute blinking on and off.

Possibility of erasing the accumulated time.

Programming time for tests without this affecting the accounting.

Possibility of detaining the time discount if the outside apparatus is not operating (except in 24 and 48 hour modes).

Programming the minimum credit insertion required for the first time period granted.

TEMPUS III - 35 -OYK ENZA

Page 35: Azkoyen Tempus III Timer Manual

3.3.2. Operation characteristics

3.3.2.1. Configuration of the mode selection microswitches:

SW4 SW3 SW2 SW1

OFF OFF OFF ON

The operating mode must always be changed with the Tempus III switched off

3.3.2.2. Configuration of connector JP4 of the control card + power supply:

JP4 CONNECTOR

Pins Comment

1-2 Contacts without voltage of relay K2, if Tempus III has time, will be closed.

3-4 They have to be short-circuited to discount time, if not, the countdown will stop.

5-6 Power output from the charge apparatus (220 VAc. with 6 A protection fuse).

7-8 Supply voltage of Tempus III (220 Vac.).

1

2

3

4

JP4

5

6

7

8MAINS input (220VAc.))

K2 output

Short-circuited in order to discount

Charge supply (220VAc.)

In order for the Tempus III to work in this operating mode it has to be configured. This is done with the four microswitches of selector NN6, which must be in the following positions for timer mode A

- 36 - PAYMENT MEANSOYK ENZA

Page 36: Azkoyen Tempus III Timer Manual

3.3.2.3.Operation confirmation of the charge:

The Tempus III also has two activation confirmation possibilities for the outside apparatus:

3.3.2.4. Direct activation of the relays:

For those applications where it may be useful, the Tempus III has a direct relay activation input through connector JP3, which will become effective when the two terminals of JP3 are short-c i rcui ted and there is no accumulated time. If this input is activated (short-circuited) when the Tempus III is offering a service (it has accumulated time), the time discount will stop.

3.3.2.5. Tariff changes and use of tariff 2:

Tariff 2 can have many uses depending on the application of the Tempus III. The most normal use is to change the tariff depending on the time (carrying out two different timetables or creating the usual "happy hour"). To do this there is an accessory called clock card, which provides the Tempus III with the real time and permits the user to program a time interval each day, which can be used either to offer a free daily service or to use the second tariff (for further information about the clock card see accessories section).

The tariff change can also be carried out by using an outside input, which will short-circuit pins 2 and 3 of connector JP5 of the control card + power supply

When tariff 1 is changed to tariff 2, or the other way round, and the apparatus is carrying out a service, this service will be affected by more or less time depending on the sales prices of tariffs 1 and 2.

P o t e n t i o m e t e r - a d j u s t a b l e consumption sensor

Outside input through pins 3 and 4 of connector JP4 (if the outside apparatus is activated, pins 3 and 4 of JP4 must be short-circuited).

3

3

2

4

Potentiometer

JP5

JP4

JP3

TEMPUS III - 37 -OYK ENZA

Page 37: Azkoyen Tempus III Timer Manual

00.00

99.59

3.3.2.6. Operation in 24 and 48 hour mode:

The Tempus III has two special operating modes, which consist of 24 or 48 hour sale.

The 24 or 48 hour operating mode can be programmed by the user, so that when the credit inserted it is sufficient to activate either of the two modes, the Tempus III will grant 24 or 48 hours' operation (depending on the credit) with uninterrupted time discount regardless of whether the outside apparatus is operating or not. With only two exceptions:

If the JP3 input is activated. (Stoppage of outside discount).

If it is on free clock period. (Stoppage due to free service).

The margin of time between when the coin is inserted and when the time discount starts is 15 seconds. Thus the credit necessary to grant 24 or 48 hours can be reached, without the time discount starting during the coin insertion interval.

If the 24 or 48 hours are granted and more credit is inserted, the time granted under normal tariff will be discounted after the period of 24 or 48 hours.

3.3.2.7. Maximum time that can be supplied:

When the apparatus shows the maximum time: 99.59 hours, on the display, it will not take any more coins, and these will be rejected by the selector and sent to the recovery box.

3.3.2.8. Minimum coin insertion:

A minimum credit insertion can be programmed on the Tempus III for the first period

of time granted, so that until that credit is reached, the display will show 00.00 and will not activate the output relays.

- 38 - PAYMENT MEANSOYK ENZA

Page 38: Azkoyen Tempus III Timer Manual

3.3.3. Programming

The general programming menu in timer mode A is comprised of 17 functions, three of which have direct access through the TEST button, these being the ones that configure the so-called personal menu.

The operation mode within the programming is very simple as can be seen from the following indications:

Advance from one functionto another by depressing the TEST button

Press the CONT buttonto access the desiredfunction and modify it

All the functions that comprise the general programming menu are described below. The first three functions, with direct access, are the ones that make up the personal menu. The rest are hidden functions of the general menu. The way to access and go from one menu to another is also explained:

Personal menu:

Used by the collectors, it is comprised only of the three functions from the general menu, which can be accessed directly. These functions are the basic ones to be able to carry out operating tests and do not affect important parameters such as times and prices of the services.

Access by depressing TEST until the message appears on the display with maximum luminous intensity. When this pushbutton is released the first function of the personal menu will blink on and off:

Time erasure

This function enables the time that the Tempus III contains to be erased at any time and is mainly used to erase the time used for tests. By depressing the CONT button the display changes to / and this option can be rejected by depressing CONT again. By depressing TEST, the order indicated on the display at that time is executed.

Function 1

TEMPUS III - 39 -OYK ENZA

Page 39: Azkoyen Tempus III Timer Manual

A free time service can be programmed with this function without it affecting the accounting. The number of minutes desired for the free period must be programmed In

xxxx. Once validated, the display will show it in hours.minutes format. The free service will start the discount as soon as the programming menu is exited.

To program the free service depress CONT and the display will show: / which indicates that it is ready to program the hundreds and thousands

that increase by successively depressing the CONT button or by keeping it depressed for fast forward. When TEST is depressed the display changes to / and the units and tens are programmed in the same way as above.

The maximum time that can be programmed in this function will be:

The equivalent, in tariff 1, of the maximum coin insertion without 24 hour grant (price of 24 hours minus 5 pts.).

Charge of a free service

Time charge in 24 hour mode

Function 2

Function 3

XxxX

Xxxx

With this function a longer period of time than that programmed in function can be programmed, if the 24-hour function has been prepared. The time charged

in the timer will not affect the accounting and on being time in 24-hour Mode it will continue discounting although the outside apparatus is disconnected. The programming range is between 0 and 9999 minutes and the programming method, similar to the previous function, is as follows:

When CONT is depressed, the display will show: / w h i c h indicates that it is ready to program the hundreds and thousands that are increased by successively depressing the CONT button, or by keeping it depressed if fast forward is desired. When TEST is depressed the display changes to / and starts to program the units and tens in the same way as the above. If TEST is depressed again, the amount programmed is validated and the function is exited.

The hidden functions of the general programming menu can be accessed and displayed by short-circuiting the two pins of connector JP3 and then depressing TEST. If TEST is depressed without short-circuiting these pins, the programming is exited going onto the work status.

00.00

00.00

XX00.

Xx00.

- 40 - PAYMENT MEANSOYK ENZA

Page 40: Azkoyen Tempus III Timer Manual

The programming functions that comprise the hidden part of the general menu are

described below. They must be handled by experienced users:

24-hour mode operation

24-hour price

48-hour price

Function 4

Function 5

Function 6

Xxxx

Xxxx

This sets up the 24-hour mode. If / is validated by depressing TEST it will go automatically onto function 7: Tariff 1. If, on the contrary, CONT is depressed the display will show / and when validated, it will be possible to program functions 5 and 6 of the 24 and 48 hour prices.

The price for a 24-hour service is programmed in this function. The display will s h o w t h e p r i c e c u r r e n t l y p r o g r a m m e d . To c h a n g e i t d e p r e s s C O N T a n d

/ appears on the screen, which indicates that it is ready to program the high part of the price (hundreds and thousands). These can be increased by successively depressing the CONT button and by keeping it depressed for fast forward. Once the high part o f t h e p r i c e h a s b e e n s e l e c t e d , d e p r e s s T E S T t o v a l i d a t e i t a n d g o t o

/ where the units and tens are programmed in the same way as above.

This is used to program the price for a 48 hour service. It is programmed in exactly the same way as the 24-hour price, the only consideration to be taken into account being that the 48-hour price can never be less than the 24-hour price. If a lower price is programmed for the 48-hour service than for the 24-hour one, the menu will return to function 5 and will program the 24-hour price again.

Xx.xx

Xxxx.

TEMPUS III - 41 -

Short-circuiting of the two pins

OYK ENZA

Page 41: Azkoyen Tempus III Timer Manual

Tariff 1 (price/hour)

Tariff 2 (price/hour)

Coin inhibition

Minimum insertion

Function 7

Function 8

Function 9

Function 10

Xxxx

Xxxx

Xxxx

The price/hour value must be programmed with this function. To program the price proceed in a similar way to that described in function 5.

If this function is programmed to zero the apparatus does not work and presents the error message (deprogrammed).

The price/hour value for tariff 2 is programmed. The programming mode is the same as the previous function (tariff 1).

The tariff can be changed depending on the time or as response to an external input as has been described above in the operation characteristics section.

If tariff 2 is programmed to zero the apparatus will only work with tariff 1.

This function can be used to inhibit the types of coins desired. The NN6 selector will reject them.

By depressing CONT the value of the coin programmed in the selector and its status blink on and off on the display: 5 or . ON means that the coin will be admitted and OFF means that it is inhibited and, therefore, will be rejected. To change the status of the coin and admit it or inhibit it depress CONT. To advance and validate depress TEST.

.

The minimum amount of credit necessary for the first period of time granted is programmed (for the Tempus III to activate the relays). The minimum insertion is programmed in a similar fashion to the programming of any of the prices described above.

- 42 - PAYMENT MEANSOYK ENZA

Page 42: Azkoyen Tempus III Timer Manual

Consumption sensor

Luminous intensity of the display

Activation of the clock cardj

Function 11

Function 12

Function 13

This selects the element that the Tempus III will use to confirm the activation of the outside apparatus. This option is very useful to stop the time discount in the event that it detects that the charge is not operating.

If / is programmed, an outside input (pins 3 and 4 of connector JP4) is used, and if, by depressing CONT / is programmed, the timer will use the adjustable consumption sensor of the control card + power supply.

The luminous intensity or brightness of the display is adjusted so that it is appropriate for the work surroundings. There are five different levels of luminous intensity and they can be changed by depressing CONT. The programmed intensity will only be active in working status as both during accounting reading and programming the maximum luminous intensity is used.

The functions described below will only appear on the general menu when the clock card is connected. If this card is not connected when validating function 12 Tempus III will exit the programming menu.

This is used to enable the clock card, if / is validated, the Tempus III will not heed the clock card data and if TEST is depressed it will exit the programming menu. If, on the contrary CONT is depressed and / i s programmed, when this option is validated depressing TEST the TEMPUS III will take into account the real time and the functions related to the clock card may be accessed. These functions are described below.

TEMPUS III - 43 -OYK ENZA

Page 43: Azkoyen Tempus III Timer Manual

Allocation of clock period

Clock setting

Period start time

Period end time

Function 14

Function 15

Function 16

Function 17

Xxxx

Xxxx

Xxxx

With this function the tariff can be changed during a daily period of time or that period can be granted as a free service.

If / is programmed the clock period will be used to offer a free daily service during that time. However, if this is changed to /by depressing CONT and it is validated by depressing TEST, tariff 2 will be applied during the programmed clock period.

This is used to set the clock with real time. The display must indicate the current time, if not it must be programmed as follows: The time of the clock card and the message

will blink on and off on the display. To change this depress CONT, then/ will appear on the display, indicating that it is ready to program the right

time. This can be increased by successively depressing the CONT button and by keeping it depressed for fast forward. Once the right time has been selected, depress TEST to validate it and change to / enabling the minutes to be programmed in the same way as the hours.

The display indicates the time when the clock period will start in which, depending on what has been programmed in function 14, a free service will be granted or tariff 2 will be applied. It is programmed in a similar way to function

The display indicates the time when the clock period will end. To programme proceed as in function and depress TEST to exit the programming menu.

Xxxx.

Xx.xx

- 44 - PAYMENT MEANSOYK ENZA

Page 44: Azkoyen Tempus III Timer Manual

3.3.4. Error messages

The error messages that the Tempus III can show on the display are described in this section, as well as the possible causes and solutions:

ERROR MESSAGES CAUSES SOLUTION

The position of the selector Configure the microswitches microswitches is not correct. for the mode selected.

The price of tariff 2 has not Program the price in the relative been programmed function.

The EEPROM of the selector The EEPROM must be has reached the safety level changed or the selector sent

toof the writing cycles. factory for repair.

TEMPUS III - 45 -OYK ENZA

Page 45: Azkoyen Tempus III Timer Manual

3.4. Timer operating mode B

3.4.1. Description and general characteristics

The timer operating mode B comprises the sale of a time

period of between 1 second and 9999 seconds.

This operating mode of the Tempus III is used for applications which require greater precision and where the services are measured in seconds. Therefore, the Tempus III must be programmed with the values and time of the service and it will be responsible for supplying the time corresponding to the credit inserted, providing this is the same as or greater than the price of a service. When the credit reaches this value, the timer activates relay K1 and it will stay activated until the time granted has been exhausted.

The main characteristics, which indicate the functionality of this working mode, are:

Unitary inhibition of all the coins, programmable by the user.

Direct viewing of the accounting.

Programming the luminous intensity of the display.

Possibility of programming two different price tariffs, which can be changed depending on the time or through an outside input. Showing the time remaining on the display, making the discount every second.

Possibility of erasing the accumulated time.

Programming time for tests without this affecting the accounting.

The time discount is stopped if the outside apparatus is not operating.

- 46 - PAYMENT MEANSOYK ENZA

Page 46: Azkoyen Tempus III Timer Manual

1

2

3

4

JP4

5

6

7

8Supply input

K2 contacts

Short-circuited in order to discount

Charge apparatus supply

3.4.2. Operation characteristics

3.4.2.1. Configuration of the microswitches:

SW4 SW3 SW2 SW1

ON ON OFF OFF

The operating mode must always be changed with the Tempus III switched off

3.4.2.2. Configuration of connector JP4 of the control card + power supply:

JP4 CONNECTOR

Pins Comment

1-2 Contacts without voltage of relay K2.

3-4 They must be short-circuited to discount time, if not, the countdown will stop.

5-6 Power output from the charge apparatus (220 VAc. with 6 A protection fuse).

7-8 Supply voltage of Tempus III (220 Vac.).

In order for the Tempus III to work in this operating mode it has to be configured. This is done with the four microswitches of selector NN6, which must be in the following positions for this case.

TEMPUS III - 47 -OYK ENZA

Page 47: Azkoyen Tempus III Timer Manual

9999

3.4.2.3 Operation confirmation of the charge:

The Tempus III also has the possibility to confirm activation of the outside apparatus, which is done through an outside input by pins 3 and 4 of connector JP4 (if the outside apparatus is activated, pins 3 and 4 of JP4 must be short-circuited).

3.4.2.4 Direct activation of relay K1:

For those applications where it may be useful, the Tempus III has a direct activation input for relay K1 through connector JP3, which will become effective when the two terminals of JP3 are short-circuited and there is no accumulated time. If this input is activated (short-circuited) when the Tempus II is offering a service (it has accumulated time), the time discount will stop.

3.4.2.5 Tariff changes and use of tariff 2:

Tariff 2 can have many uses depending on the application of the Tempus III. The most normal use is to change the tariff depending on the time (carrying out two different timetables or creating the usual "happy hour"). To do this there is an accessory called clock card, which provides the Tempus III with the real time and permits the user to program a time interval each day, which can be used either to offer a free daily service or to use the second tariff (for further information about the clock card see accessories section).

The tariff change can also be carried out by using an outside input, which will short-circuit pins 2 and 3 of connector JP5 of the control card + power supply

When tariff 1 is changed to tariff 2, or the other way round, and the apparatus carrying out a service, this service will be affected by more or less time depending on the sales prices of tariffs 1 and 2.

3.4.2.6 Maximum time that can be supplied:

When the apparatus shows the maximum

time: 9999 seconds, on the display, it will not take any more coins, and these will be rejected by the selector and sent to the recovery box.

- 48 - PAYMENT MEANSOYK ENZA

Page 48: Azkoyen Tempus III Timer Manual

3.4.3. Programming

The general programming menu in timer mode A is comprised of 13 functions, three of which have direct access through the TEST button, these being the ones that configure the so-called personal menu.

The operation mode within the programming is very simple as can be seen from the following indications:

Advance from one functionto another by depressing the TEST button

Press the CONT buttonto access the desiredfunction and modify it

All the functions that comprise the general programming menu are described below. The first two functions, with direct access, are the ones that make up the personal menu. The rest are hidden functions of the general menu. The way to access and go from one menu to another is also explained:

Personal menu:

Used by the collectors, it is comprised only of the three basic functions to be able to carry out operating tests and they do not affect important parameters such as times and prices of the services.

Access by depressing TEST until the message appears on the display with maximum luminous intensity. When this pushbutton is released the first function of the personal menu will blink on and off:

Time erasure

This erases the time that the Tempus III contains at any time. It is mainly used to erase the time used for tests. By depressing the CONT button the display changes to / and this option can be rejected by depressing CONT again. By depressing TEST, the order indicated on the display at that time is executed

Function 1

TEMPUS III - 49 -OYK ENZA

Page 49: Azkoyen Tempus III Timer Manual

Short-circuiting the two pins

A free time service can be programmed with this function without it affecting the accounting. The number of minutes desired for the free period must be programmed In

xxxx. Once validated, the display will show it in hours.minutes format. The free service will start the discount as soon as the programming menu is exited.

To program the free service depress CONT and the display will show:/ which indicates that it is ready to program the hundreds and thousands

that increase by successively depressing the CONT button by keeping it depressed for fast forward. When TEST is depressed the display changes to / and the units and tens are programmed in the same way as above.

Charge of a free service

Function 2

XxxX

00.00

Xx00.

To continue with the programming menu and view the functions of the main menu depress TEST whilst the two pins of connector JP3 are short-circuited. If TEST is depressed without short-circuiting these pins the programming is exited going onto the work status.

The maximum time that can be programmed in this function will be:

The equivalent, in tariff 1, of the maximum coin insertion without 24 hour grant (price of 24 hours minus 5 pts.).

Tariff 1 (price/service)

Function 3

Xxxx

The price/service value must be programmed with this function. To program the price proceed in a similar way to that described in function 2.

If this function is programmed to zero the apparatus does not work and presents the error message (deprogrammed).

- 50 - PAYMENT MEANS

The programming functions that comprise the hidden part of the general menu are described below. They must be handled by experienced users:

OYK ENZA

Page 50: Azkoyen Tempus III Timer Manual

Coin inhibition

Function 5

This function can be used to inhibit the types of coins desired. The NN6 selector will reject them.

By depressing CONT the value of the coin programmed in the selector and its status blink on and off on the display:5 / or . ON means that the coin will be admitted and OFF means that it is inhibited and, therefore, will be rejected. To change the status of the coin and admit it or inhibit it depress CONT. To advance and validate depress TEST.

Service time

Service end warning time

Function 6

Function 7

Xxxx

Xxxx

The duration of the service, which will be between 1 and 9999 seconds, will be p rogrammed. The p rogramming mode i s as fo l l ows : by depress ing CONT

/ will appear on the display. This means that it is ready to program the high part of the time (hundreds and thousands). This can be increased by successively depressing the CONT button and by keeping it depressed for fast forward. Once the correct h i g h p a r t h a s b e e n s e l e c t e d , d e p r e s s T E S T t o v a l i d a t e i t a n d c h a n g e t o

/ , which will enable the low part (units and tens) to be programmed like the above.

The warning relay (K2) activation time is programmed after the service or activation time of K1 ends. This is used in special applications to warn the user that the service time has concluded.

The way to program the time of this function is exactly the same as described for the previous function

Xxxx.

Xx.xx

TEMPUS III - 51 -

Tariff 2 (price/service)

Function 4

Xxxx

The price/service value for tariff 2 is programmed. The programming mode is the same as the previous function (tariff 1).

The tariff can be changed depending on the time or as response to an external input as has been described above in the operation characteristics section.

If tariff 2 is programmed to zero the apparatus will only work with tariff 1.

OYK ENZA

Page 51: Azkoyen Tempus III Timer Manual

Luminous intensity of the display

Function 8

The luminous intensity or brightness of the display is adjusted so that it is appropriate for the work surroundings. There are five different levels of luminous intensity and they can be changed by depressing CONT. The programmed intensity will only be active in working status as both during accounting reading and programming the maximum luminous intensity is used.

The functions described below will only appear on the general menu when the clock card is connected. If this card is not connected when validating function 12 Tempus III will exit the programming menu.

Activation of the clock card

Function 9

This is used to enable the clock card, if / is validated, the Tempus III will not heed the clock card data and if TEST is depressed it will exit the programming menu. If, on the contrary CONT is depressed and / i s programmed, when this option is validated depressing TEST the TEMPUS III will take into account the real time and the functions related to the clock card may be accessed. These functions are described below.

Allocation of clock period

Function 10

With this function the tariff can be changed during a daily period of time or that period can be granted as a free service.

If / is programmed the clock period will be used to offer a free daily service during that time. However, if this is changed to / by depressing CONT and it is validated by depressing TEST, tariff 2 will be applied during the programmed clock period.

- 52 - PAYMENT MEANSOYK ENZA

Page 52: Azkoyen Tempus III Timer Manual

Clock setting

Period start time

Period end time

Function 11

Function 12

Function 13

Xxxx

Xxxx

Xxxx

This is used to set the clock with real time. The display must indicate the current time, if not it must be programmed as follows: The time of the clock card and the message

will blink on and off on the display. To change this depress CONT, then / will appear on the display, indicating that it is ready to program the right

time. This can be increased by successively depressing the CONT button and by keeping it depressed for fast forward. Once the right time has been selected, depress TEST to validate it and change to / enabling the minutes to be programmed in the same way as the hours.

The display indicates the time when the clock period will start in which, depending on what has been programmed in function 14, a free service will be granted or tariff 2 will be applied. It is programmed in a similar way to function

The display indicates the time when the clock period will end. To programme proceed as in function and depress TEST to exit the programming menu.

Xxxx.

Xx.xx

TEMPUS III - 53 -OYK ENZA

Page 53: Azkoyen Tempus III Timer Manual

3.4.4. Error messages

The error messages that the Tempus III can show on the display are described in this section, as well as the possible causes and solutions:

ERROR MESSAGES CAUSES SOLUTION

The position of the selector Configure the microswitches microswitches is not correct. for the mode selected.

The price of tariff 2 has not Program the price in the relative been programmed function.

The EEPROM of the selector The EEPROM must be has reached the safety level changed or the selector sent to of the writing cycles. factory for repair.

- 54 - PAYMENT MEANSOYK ENZA

Page 54: Azkoyen Tempus III Timer Manual

3.5. Starter mode operation

Starter mode operation consists in the sale of a power supply time, which is used to activate the automatism of the charge apparatus.

3.5.1. Description and general characteristics

This operating mode of the Tempus III is used for applications where the services only require a supply impulse (220 Vac.) used to start up the automatism of the machine it controls. Therefore, the value of the price/service must be programmed and this will be responsible for supplying the power during the necessary time (programmable between 1 and 9999 seconds) to activate the charge apparatus.

When the credit reaches the programmed service price value, relays K1 and K2 are activated simultaneously and remain in this status until the time granted has been exhausted.

The main characteristics, which indicate the functionality of this working mode, are:

Viewing on the display of the service price.

Indication, whilst the coins are being inserted, of the remaining credit for the service to be granted.

Unitary inhibition of all the coins, programmable by the user.

Direct viewing of the accounting. Showing the time remaining on the display, making the discount every second.

Possibility of inhibition of all the coins by an outside input.

TEMPUS III - 55 -OYK ENZA

Page 55: Azkoyen Tempus III Timer Manual

1

2

3

4

JP4

5

6

7

8MAINS input (220VAc.)

K2 contacts

Coin inhibition

Output (220VAc.)

3.5.2. Operation characteristics

3.5.2.1. Configuration of the mode selection microswitches:

SW4 SW3 SW2 SW1

OFF OFF ON OFF

The operating mode must always be changed with the Tempus III switched off.

3.5.2.2. Configuration of connector JP4 of the control card + power supply:

JP4 CONNECTOR

Pins Comment

1-2 Contacts without voltage of relay K2, if Tempus III has time, will be closed.

3-4 Total coin inhibition control. If they are short-circuited no coin is admitted.

5-6 Power output from the charge apparatus (220 VAc. with 6 A protection fuse).

7-8 Supply voltage of Tempus III (220 Vac.).

In order for the Tempus III to work in this operating mode it has to be configured. This is done with the four microswitches of selector NN6, which must be in the following positions for the starter mode:

- 56 - PAYMENT MEANSOYK ENZA

Page 56: Azkoyen Tempus III Timer Manual

3.5.2.3 Total coin inhibition input:

The Tempus III has an outside input for total coin inhibition, which, when activated, sends the coins directly to the recovery box.

To inhibit all the coins, pins 3 and 4 of connector JP4 must be connected or short-circuited. If these pins are not connected those coins, which have been programmed, will be admitted.

3.5.3. Programming

The general programming menu for the starter mode is comprised of three functions, which are directly accessed through the TEST button.

The procedure to work within programming is very simple as can be seen from the following indications:

All the functions that comprise the general programming menu are described below. To access them activate TEST pushbutton unti l the display shows the message with maximum luminous intensity. When this pushbutton is released the first function of the menu will blink on and off.

Advance from one function to another by depressing the TEST button

Press the CONT buttonto access the desiredfunction and modify it

TEMPUS III - 57 -OYK ENZA

Page 57: Azkoyen Tempus III Timer Manual

Tariff 1 (price/service)

Service Time

Function 1

Function 2

Xxxx

Xxxx

The service price value is programmed.

To program the service value depress CONT, then the display will show:/ which means that it is ready to program the hundreds and thousands,

which can be increased by successively depressing the CONT button or by keeping it depressed for fast forward. When TEST is depressed the display changes to

/ and goes on to program the units and tens in the same way as above.

If this function is programmed to zero the apparatus does not work and shows the error message (deprogrammed).

Xx00.

Xxxx.

00.00

In this function, the duration of the service, which must be between 1 and 9999 seconds, will be programmed. The programming mode is as follows: by depressing

/ will appear on the display. This means that it is ready to program the high part of the time (hundreds and thousands). This can be increased by successively depressing the CONT button and by keeping it depressing for fast forward. Once the correct h i g h p a r t h a s b e e n s e l e c t e d , d e p r e s s T E S T t o v a l i d a t e i t a n d g o o n t o

/ .which will enable the low part (units and tens) to be programmed like the above

Coin inhibition

Function 3

This function can be used to inhibit the types of coins desired. The NN6 selector will reject them.

By depressing CONT the value of the coin programmed in the selector and its status blink on and off on the display: 5 / or ON means that that coin will be admitted and OFF means that it will be rejected. To change the status of the coin and admit it or inhibit it depress CONT. To advance and validate depress TEST.

When programming the acceptance or rejection of the 500-peseta coin and this is validated by depressing TEST, the Tempus III will exit the programming to go on to working status.

Xx.xx

- 58 - PAYMENT MEANSOYK ENZA

Page 58: Azkoyen Tempus III Timer Manual

3.5.4. Error messages

The error messages that the Tempus III can show on the display are described in this section, as well as the possible causes and solutions:

ERROR MESSAGES CAUSES SOLUTION

The position of the selector Configure the microswitches microswitches is not correct. for the mode selected.

The price of tariff 1 has not Program the price in the relative been programmed function.

The EEPROM of the selector The EEPROM must be has reached the safety level changed or the selector sent to of the writing cycles. factory for repair.

TEMPUS III - 59 -OYK ENZA

Page 59: Azkoyen Tempus III Timer Manual

3.6. Photocopier control operating mode A

3.6.1. Description and general characteristics

The operation in photocopier control mode A consists in the sale of impulses, which activate the setting up of the charge. The impulse will end when confirmation is obtained of the end of the last service by means of outside input.

This operating mode of the Tempus III is used for applications where on/off impulses of an indefinite time are required until the conclusion of a specific service. Therefore the Tempus III requires information about the conclusion of the service, so that it can discount it from the accumulated value that appears on the display and, if it is the last, stop the setting up of the charge. The service price value will have to be programmed in the Tempus III and will be responsible for supplying the impulses depending on the credit inserted, ending when confirmation is obtained of the execution of the last service.

When the credit reaches the programmed service price value, the Tempus III activates relays K1 and K2 simultaneously and remains so until the number of services granted have been totally discounted.

The main characteristics, which indicate the functionality of this working mode are:

Viewing on the screen of the number of services available.

Unitary inhibition of all the coins, programmable by the user.

Direct viewing of the accounting.

Possibility of using two different price tariffs, which are changed by means of outside input.

Different service discount inputs depending on the tariff used.

- 60 - PAYMENT MEANSOYK ENZA

Page 60: Azkoyen Tempus III Timer Manual

1

2

3

4

JP4

5

6

7

8Supply input (220VAc.)

Charge enabling

End of service sensor

Output 220VAc. (Not used)

3.6.2. Operation characteristics

3.6.2.1. Configuration of the mode selection microswitches:

SW4 SW3 SW2 SW1

OFF ON OFF OFF

The operating mode must always be changed with the Tempus III switched off

3.6.2.2. Configuration of connector JP4 of the control card + power supply

JP4 CONNECTOR

Pins Comment

1-2 Output relay K2. Contacts without voltage, which on standby will beopen. It must be connected when the charge apparatus is enabled.

3-4 Service end sensor input. The charge apparatus must informof the end of each service by short-circuiting these pins.On stand-by they will remain open

5-6 Not used (Output of relay K1 of 220 Vac with 6 A protection fuse when the Tempus III has services).

7-8 Supply voltage of the Tempus III (220 Vac.).

In order for the Tempus III to work in this operating mode it has to be configured. This is done with the four microswitches of selector NN6, which must be in the following positions for photocopier control mode A:

TEMPUS III - 61 -OYK ENZA

Page 61: Azkoyen Tempus III Timer Manual

3.6.2.3 Tariff change and discount input

The Tempus III has an outside input used to change the tariff through pins 2 and 3 of connector Jp5:

As two different tariffs are used, there are also end of service inputs depending on the tariff used:

PINS 2 AND 3 OF JP5 APPLICABLE TARIFF

OPEN TARIFF 1

CLOSED TARIFF 2

APPLICABLE TARIFF DISCOUNT INPUT

TARIFF 1 PINS 3 and 4 of CONNECTOR JP4

TARIFF 2 PINS 1 and 2 of CONNECTOR JP3

If the tariff is changed before the accumulated services have ended the Tempus III will grant the equivalent to the operative tariff.

The conditions, which the end of service output signal of the apparatus, connected to the Tempus III, must satisfy are the following:

The output signal must be stable and last for at least 30 milliseconds.

There must be at least 100 milliseconds' separation between the output signals.

1

3

3

2

2

4

DISCOUNT INPUT TARIFF 2

DISCOUNTINPUT TARIFF 1

OPEN TARIFF 1

CLOSED TARIFF 2 JP3

JP4

JP5

- 62 - PAYMENT MEANSOYK ENZA

Page 62: Azkoyen Tempus III Timer Manual

3.6.3. Programming

The general programming menu for photocopier control mode A is comprised of four functions, which are directly accessed through the TEST button.

The procedure to work within programming is very simple as can be seen from the following indications:

All the functions that comprise the general programming menu are described below. To access them activate TEST pushbutton unti l the display shows the message with maximum luminous intensity. When this pushbutton is released the first function of the menu will blink on and off:

Service erasure

This function enables the number of services that the Tempus III contains to be erased at any time and is mainly used to erase the services used for tests. By depressing the CONT button the display changes to / and this option can be rejected by depressing CONT again. By depressing TEST, the order indicated on the display at that time is executed

Function 1

vance from one function to another by depressing the TEST button

Press the CONT buttonto access the desiredfunction and modify it

TEMPUS III - 63 -OYK ENZA

Page 63: Azkoyen Tempus III Timer Manual

Tariff 1 (price/service)

Function 2

Xxxx

The service price value is programmed.

To program the service value depress CONT, then the display will show:/ which indicates that it is ready to program the hundreds and thousands,

which can be increased by successively depressing the CONT button or by keeping it depressed for fast forward. By depressing TEST the display changes to

/ and goes on to program the units and tens in the same way as the above.

If this function is programmed to zero the apparatus does not work and shows the error message (deprogrammed).

Xx00.

00.00

Tariff 2 (price/service)

Function 3

Xxxx

This function is used to be able to program the value of a second service price. To program it proceed in a similar fashion to that indicated in the previous function for tariff 1.

Coin inhibition

Function 4

This function is used to be able to inhibit the types of coins desired. Selector NN-6 will reject them.

By depressing CONT the value of the coin programmed in the selector and its status will blink on and off the display:5 / or ON means that the coin will be admitted and OFF means that it is inhibited and, therefore, will be rejected. To change the status of the coin and admit it or inhibit it depress CONT. To advance and validate depress TEST.

When programming the acceptance or rejection of the 500-peseta coin and it is validated by depressing TEST, the TEMPUS III will exit the programming to go on to the working status.

- 64 - PAYMENT MEANSOYK ENZA

Page 64: Azkoyen Tempus III Timer Manual

3.6.4. Error messages

The error messages that the Tempus III can show on the display are described in this section, as well as the possible causes and solutions:

ERROR MESSAGES CAUSES SOLUTION

The position of the selector Configure the microswitches microswitches is not correct. for the mode selected.

The price of tariff 1 has not Program the price in the relative been programmed function.

The EEPROM of the selector The EEPROM must be has reached the safety level changed or the selector sent to of the writing cycles. factory for repair.

TEMPUS III - 65 -OYK ENZA

Page 65: Azkoyen Tempus III Timer Manual

3.7. Photocopier control operating mode B

3.7.1. Description and general characteristics

The operation in photocopier control mode B consists in the sale of impulses, which activate the setting up of the charge. The impulse will end when confirmation is obtained of the end of each service by means of outside input.

This operating mode of the Tempus III is used for applications where on/off impulses of an indefinite time are required until the conclusion of a specific service. Therefore the Tempus III requires information about the conclusion of the service, so that it can discount it from the accumulated value that appears on the display and stop the setting up of the charge whilst this signal lasts. The service price value will have to be programmed in the Tempus III and it will be responsible for supplying the impulses depending on the credit inserted, ending when confirmation is obtained of the execution of the last service.

When the credit reaches the programmed service price value, the Tempus III activates relays K1 and K2 simultaneously and remains so until it receives the end of service signal, which will deactivate them for 100 milliseconds, activating them again if it has credit remaining.

The main characteristics, which indicate the functionality of this working mode are:

Viewing on the screen of the credit available.

Unitary inhibition of all the coins, programmable by the user.

Direct viewing of the accounting.

Possibility of using two different price tariffs, which are changed by means of outside input.

Different service discount inputs depending on the tariff used.

- 66 - PAYMENT MEANSOYK ENZA

Page 66: Azkoyen Tempus III Timer Manual

1

2

3

4

JP4

5

6

7

8Supply of Tempus III (220VAc.)

Charge set-up

End of service sensor

K1 output (220VAc.)

3.7.2. Operation characteristics

3.7.2.1. Configuration of the mode selection microswitches:

SW4 SW3 SW2 SW1

ON OFF OFF OFF

The operating mode must always be changed with the Tempus III switched off.

3.7.2.2. Configuration of connector JP4 of the control card + power supply

JP4 CONNECTOR

Pins Comment

1-2 Output relay K2. Contacts without voltage, which on standby will beopen. It must be connected when the charge apparatus is enabled.

3-4 Service end sensor input. The charge apparatus must informof the end of each service by short-circuiting these pins.On stand-by they will remain open

5-6 Not used (Output of relay K1 of 220 Vac with 6 A protection fuse when the Tempus III has services).

7-8 Supply voltage of the Tempus III (220 VAc.).

In order for the Tempus III to work in this operating mode It has to be configured. This is done with the four microswitches of selector NN6, which must be in the following positions for photocopier control mode B:

TEMPUS III - 67 -OYK ENZA

Page 67: Azkoyen Tempus III Timer Manual

3.7.2.3 Tariff change and discount input

The Tempus III has an outside input used to change the tariff through pins 2 and 3 of connector Jp5:

As two different tariffs are used, there are also end of service inputs depending on the tariff used:

PINS 2 AND 3 OF JP5 APPLICABLE TARIFF

OPEN TARIFF 1

CLOSED TARIFF 2

APPLICABLE TARIFF DISCOUNT INPUT

TARIFF 1 PINS 3 and 4 of CONNECTOR JP4

TARIFF 2 PINS 1 and 2 of CONNECTOR JP3

If the tariff is changed before the accumulated services have ended the Tempus III will grant the equivalent to the operative tariff.

The conditions, which the end of service output signal of the apparatus, connected to the Tempus III, must satisfy are the following:

The output signal must be stable and last for at least 30 milliseconds.

There must be at least 100 milliseconds' separation between output signals.

1

3

3

2

2

4

DISCOUNT INPUT TARIFF 2

DISCOUNTINPUT TARIFF 1

OPENTARIFF 1

CLOSED TARIFF 2 JP3

JP4

JP5

- 68 - PAYMENT MEANSOYK ENZA

Page 68: Azkoyen Tempus III Timer Manual

3.7.3. Programming

:

The general programming menu for photocopier control mode A is comprised of four functions, which are directly accessed through the TEST button.

The procedure to work within programming is very simple as can be seen from the following indications:

All the functions that comprise the general programming menu are described below. To access them activate TEST pushbutton unti l the display shows the message with maximum luminous intensity. When this pushbutton is released the first function of the menu will blink on and off:

Service erasure

This function enables the number of services that the Tempus III contains to be erased at any time and is mainly used to erase the services used for tests. By depressing the CONT button the display changes to / and this option can be rejected by depressing CONT again. By depressing TEST, the order indicated on the display at that time is executed.

Function 1

Advance from one function to another by depressing the TEST button

Press the CONT buttonto access the desiredfunction and modify it

TEMPUS III - 69 -OYK ENZA

Page 69: Azkoyen Tempus III Timer Manual

Tariff 1 (price/service)

Function 2

Xxxx

The service price value is programmed.

To program the service value depress CONT, then the display will show:/ which indicates that it is ready to program the hundreds and thousands,

which can be increased by successively depressing the CONT button or by keeping it depressed for fast forward. By depressing TEST the display changes to

/ and goes on to program the units and tens in the same way as the above.

If this function is programmed to zero the apparatus does not work and shows the error message (deprogrammed).

Xx00.

00.00

Tariff 2 (price/service)

Function 3

Xxxx

This function is used to be able to program the value of a second service price. To program it proceed in a similar fashion to that indicated in the previous function for tariff 1.

Coin inhibition

Function 4

This function is used to be able to inhibit the types of coins desired. Selector NN-6 will reject them.

By depressing CONT the value of the coin programmed in the selector and its status will blink on and off the display: 5 / or . ON means that that coin will be admitted and OFF means that it is inhibited and, therefore, will be rejected. To change the status of the coin and admit it or inhibit it depress CONT. To advance and validate depress TEST.

When programming the acceptance or rejection of the 500-peseta coin and it is validated by depressing TEST, the TEMPUS III will exit the programming to go on to the working status.

- 70 - PAYMENT MEANSOYK ENZA

Page 70: Azkoyen Tempus III Timer Manual

3.7.4. Error messages

The error messages that the Tempus III can show on the display are described in this section, as well as the possible causes and solutions:

ERROR MESSAGES CAUSES SOLUTION<

The position of the selector Configure the microswitches microswitches is not correct. for the mode selected.

The price of tariff 1 has not Program the price in the relative been programmed function.

The EEPROM of the selector The EEPROM must be has reached the safety level changed or the selector sent to of the writing cycles. factory for repair.

TEMPUS III - 71 -OYK ENZA

Page 71: Azkoyen Tempus III Timer Manual

4. Accessories4.1. Clock card

Clock card

Reference: ZT43304640-0

This is an accessory that can be attached to the Tempus III and that is used for specific applications where a clock in real time is required, as for example in places where promotions are carried out depending on the time (happy-hour). It can also be used to give a free service per day or to apply the second tariff at a certain time.

Furthermore, the Tempus III uses the clock card to discount the time without interruption when working in 24 or 48-hour mode although the apparatus is disconnected during some periods of time.

To enable the clock card in a time period the Tempus III programming must be accessed, proceeding as described in the programming sections of the different operating modes.

The clock card must be connected with the Tempus III switched off.

The clock card must be connected to connector JP2 of the control card + power supply. To do this the display bundle must be disconnected installing the clock card in its place and connecting this bundle to it, as shown in the following diagram:

Display bundle

- 72 - PAYMENT MEANSOYK ENZA

Page 72: Azkoyen Tempus III Timer Manual

4.2. Tempus III omega unit

The Tempus III omega unit is a support used to secure the Tempus III to a wall or to any other element. To do this, the Tempus III omega unit will firstly be placed on the wall by means of the six 7.5 diameter boreholes, and then the Tempus III will be attached to the 4 metric screws of the support, fitting perfectly into them.

Omega unit

12

4 m

m.

107 mm.

7,5

mm

.

TEMPUS III - 73 -

Reference: 42909621-0