b' · 2019-03-18 · detail 'b' scale: 3" = 1'-0" factory torsion...

9
INTERIOR INSTALLATION DETAIL 'A' SCALE: 3" = 1'-0" DETAIL 'B' SCALE: 3" = 1'-0" 48" MAX O.C. CROSS TEE SPACING MAIN TEE O.C. SPACING VARIES, 24" MIN - 96" MAX SPACING 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS. SEE DETAIL A1.2 CROSS TEE 48" O.C., TYP., CENTERED MID PANEL MAIN TEE TORSION SPRING TORSION SPRING PANEL 12 GA HANGER WIRE, 48" O.C. ALONG MAIN TEE, NOT BY HUNTER DOUGLAS MAIN TEE 2" SIDE LEG 1" FRONT LEG TORSION SPRING TORSION SPRING PANEL 48" MAX MAIN TEE SPAN 'A' 'A' 'B' 'B' 12" MIN - 24" MAX PANEL WIDTH TEE GRID SPECIFICATIONS SEE DETAIL A1.3 SUSPENSION REQUIREMENTS SEE DETAIL A1.2 12" MAX MAIN TEE OVERHANG FIXTURE SPECIFICATIONS SEE DETAIL A1.6 AND A1.7 TYPICAL SYSTEM SECTION SEE DETAIL 'A' AND 'B' PANEL SPECIFICATIONS SEE DETAIL A1.1 TRIMLESS ACCESSIBILITY SEE DETAIL A1.5 WALL TRIM CONDITIONS SEE DETAIL A1.4 24" MIN - 96" MAX PANEL LENGTH 5015 Oakbrook Parkway, Suite 100 Norcross, GA 30093 O 800.366.4327 F 770.806.0214 CTSpecialtyCeilings.com All rights reserved. This drawing is the property of CertainTeed Ceilings Corporation. It may not be copied or multiplied, neither wholly nor partly. It may not be submitted for perusal to third parties. SPECIFICATIONS (unless noted otherwise) MATERIAL: .032" | .040" | .050" | .063" ALUMINUM FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LUXACOTE PERFORATION: SEE DETAIL A1.1, TABLE 1 OVERALL ISOMETRIC VIEW PROJECT: TORSION SPRING PRODUCT SPECIFICATIONS DRAWING NUMBER: TS-A1.0 SCALE: AS SHOWN DRAWN BY: HD ENGINEERING DATE: 2/15/2019

Upload: others

Post on 31-May-2020

6 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: B' · 2019-03-18 · detail 'b' scale: 3" = 1'-0" factory torsion spring panel end factory torsion spring panel end 12 ga hanger wire, 48" o.c. along main tee, not by hunter douglas

INTERIOR INSTALLATION

DETAIL 'A'SCALE: 3" = 1'-0"

DETAIL 'B'SCALE: 3" = 1'-0"

48" MAX O.C. CROSS TEE SPACING

MAIN TEE O.C. SPACING VARIES,

24" MIN - 96" MAX SPACING

12 GA HANGER WIRE, BYOTHERS, NOT BY HUNTERDOUGLAS. SEE DETAIL A1.2

CROSS TEE 48" O.C., TYP.,CENTERED MID PANEL

MAIN TEE

TORSIONSPRING

TORSIONSPRINGPANEL

12 GA HANGER WIRE, 48" O.C. ALONGMAIN TEE, NOT BY HUNTER DOUGLAS

MAIN TEE

2" S

IDE

LEG

1" F

RON

TLE

GTORSION SPRING

TORSION SPRING PANEL

48" MAX MAIN TEE SPAN

'A'

'A'

'B'

'B'

12" MIN - 24" MAX

PANEL WIDTH

TEE GRID SPECIFICATIONSSEE DETAIL A1.3

SUSPENSION REQUIREMENTSSEE DETAIL A1.2

12" MAX

MAIN TEE OVERHANG

FIXTURE SPECIFICATIONSSEE DETAIL A1.6 AND A1.7

TYPICAL SYSTEM SECTIONSEE DETAIL 'A' AND 'B'

PANEL SPECIFICATIONSSEE DETAIL A1.1

TRIMLESS ACCESSIBILITYSEE DETAIL A1.5

WALL TRIM CONDITIONSSEE DETAIL A1.4

24" MIN - 96" MAX PANEL LENGTH

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" | .050" | .063" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LUXACOTE

PERFORATION: SEE DETAIL A1.1, TABLE 1

OVERALL ISOMETRIC VIEW

PROJECT: TORSION SPRING PRODUCT SPECIFICATIONS

DRAWING NUMBER: TS-A1.0

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 2/15/2019

Page 2: B' · 2019-03-18 · detail 'b' scale: 3" = 1'-0" factory torsion spring panel end factory torsion spring panel end 12 ga hanger wire, 48" o.c. along main tee, not by hunter douglas

PERF #102 (14.0% OPEN)

MAX WIDTH

TABLE 1 - PERFORATION OPTIONS

MAX LENGTHPERFORATION MAX WIDTH MAX LENGTHPERFORATION

PERF #103 (20.0% OPEN)

PERF #106 (16.0% OPEN)

PERF #107 (28.0% OPEN)

PERF #109 (36.0% OPEN)

PERF #110 (36.0% OPEN)

PERF #185 (3.1% OPEN)

PERF #201 (19.6% OPEN)

PERF #202 (5.43% OPEN)

PERF #301 (11.0% OPEN)

PERF #312 (33.0% OPEN)

PERF #314 (25.0% OPEN)

PERF #315 (6.25% OPEN)

PERF #350 (70.0% OPEN)

PERF #355 (18.0% OPEN)

PERF #375 (25.0% OPEN)

PERF #625 (19.5% OPEN)

PERF #750 (19.2% OPEN)

30" 60"

30"

30"

30"

30"

24"

60"

60"

60"

60"

60"

24" 24"

24" 96"

24" 96"

24" 96"

23.5" 96"

23.5" 96"

24" 96"

24" 24"

23.5" 96"

24" 96"

23.5" 96"

23.5" 96"

MATERIAL THICKNESS· TORSION SPRING PLANKS: .032", .040", .050", OR .063" ALUMINUM

PANEL FINISHES· PAINTED & POWDER COATED - INTERIOR & EXTERIOR· LUXACOTE - INTERIOR & EXTERIOR· DECORATED WOOD FINISH (POWDER COATED) - INTERIOR & EXTERIOR· SEE TABLE 2 FOR PERFORATION OPTIONS

PERF #111 (4.0% OPEN)

PERF #112 (7.0% OPEN)

PERF #114 (5.0% OPEN)

PERF #119 (8.0% OPEN)

PERF #122 (5.5% OPEN)

PERF #132 (20.0% OPEN)

30"

30"

30"

30"

24"

60"

60"

60"

60"

96"

30" 60"

PERF #150 (4.0% OPEN) 30" 60"

MAX WIDTH MAX LENGTHPERFORATION MAX WIDTH MAX LENGTHPERFORATION

INTERIOR INSTALLATION

12" MIN - 24" MAX PANEL WIDTH1"

FRO

NT

LEG

12 GA HANGER WIRE, 48" O.C. MAX ALONG LENGTHOF MAIN TEE, TYP., NOT BY HUNTER DOUGLAS

CROSS TEE 48"O.C., TYP.,CENTERED MIDPANEL, BEYOND

TORSION SPRING PANEL DETAIL

MAIN TEE

TORSION SPRING

12 GA HANGER WIRE, 48" O.C. ALONGMAIN TEE, NOT BY HUNTER DOUGLAS

CROSS TEE 48" O.C., TYP.,CENTERED MID PANEL

24" MIN - 96" MAX PANEL LENGTH

2" S

IDE

LEG

TORSION SPRING PANEL DETAIL

MAIN TEE

TORSION SPRING

215 32" S

YSTE

MDE

PTH

221 32" S

YSTE

MDE

PTH

PANEL CONFIGURATIONS:· 12" AND 24" WIDTHS· 24", 48", 60", 72", AND 96" LENGTHS· OTHER SIZES AVAILABLE, CONTACT HUNTER DOUGLAS

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" | .050" | .063" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LUXACOTE

PERFORATION: SEE ABOVE, TABLE 1

PANEL SPECIFICATIONS

PROJECT: TORSION SPRING PRODUCT SPECIFICATIONS

DRAWING NUMBER: TS-A1.1

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 2/15/2019

Page 3: B' · 2019-03-18 · detail 'b' scale: 3" = 1'-0" factory torsion spring panel end factory torsion spring panel end 12 ga hanger wire, 48" o.c. along main tee, not by hunter douglas

INTERIOR INSTALLATION

SUSPENSION SPECIFICATIONSSCALE: NTS

MAIN TEE 15/16" OR 1-1/2" DRY WALL GRIDPUNCHED 6" O.C.

CROSS TEE 48" O.C., TYP.,CENTERED MID PANEL

PANEL "B"FULLYENGAGED

PANEL "A"FULLY RELEASED

2

1

1

2

1

1

3

3

TORSIONSPRING

96" MAX PANEL LENGTH

24" MAX PANEL WIDTH12 GA HANGER WIRE 48" O.C.

MAX ALONG MAIN TEE

12 GA HANGER WIRE, NOTBY HUNTER DOUGLAS

MAIN TEE

TORSION SPRING

CROSS TEE 48" O.C.,TYP., CENTEREDMID PANEL

TORSION SPRING PANEL

PANEL INSTALLATION ISOMETRICSCALE: NTS

12 GA HANGER WIRE, 48" O.C. MAX ALONGLENGTH OF MAIN TEE, TYP., NOT BYHUNTER DOUGLAS

2" S

IDE

LEG

TORSIONSPRINGPANEL

MAIN TEE DIRECTION

PANEL INSTALLATION:

1. COMPRESS TORSION SPRINGS.

2. PUSH PANEL AND TORSION SPRINGSTHROUGH PUNCHED MAIN TEE HOLES.

3. RELEASE SPRINGS TO HOLD PANEL IN PLACE.

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" | .050" | .063" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LUXACOTE

PERFORATION: SEE DETAIL A1.1, TABLE 1

SUSPENSION SPECIFICATIONS

PROJECT: TORSION SPRING PRODUCT SPECIFICATIONS

DRAWING NUMBER: TS-A1.2

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 2/15/2019

Page 4: B' · 2019-03-18 · detail 'b' scale: 3" = 1'-0" factory torsion spring panel end factory torsion spring panel end 12 ga hanger wire, 48" o.c. along main tee, not by hunter douglas

12 GA HANGER WIRE, 48" O.C. ALONGMAIN TEE, NOT BY HUNTER DOUGLAS

CROSS TEE48" O.C., TYP.,CENTEREDMID PANEL

MAIN TEETORSION SPRING

'B'

'B'

'A'

'A'

SECTION 'B'SCALE: 3" = 1'-0"

SECTION 'A'SCALE: 3" = 1'-0"

MAIN TEEINTEGRALSPLICE CLIP

1-1/2"

9/16"

1-11/16"

CROSS TEE HOLE

HANGER WIREHOLE

PUNCHED TORSION SPRING HOLE

BOTTOMVIEW

SECTIONVIEW

1/4" 5/16"

7/32"

SIDEVIEW

8"

6"

INTERIOR INSTALLATION

1-1/2" DRYWALL MAIN TEESCALE: 6" = 1'-0"

15/16" MAIN TEESCALE: 6" = 1'-0"

1/4"

6" TYP.

6" TYP.

CROSS TEEHOLE

1/4"

9/16"

15/16"

5/32"

1/4"

1-21/32"

3/32"

SECTIONVIEW

SIDEVIEW

BOTTOMVIEW

PUNCHED TORSION SPRING HOLEHANGER WIREHOLE

MAIN TEE

12 GA HANGER WIRE,48" O.C. MAX ALONGMAIN TEE, BY OTHERS

MAIN TEE INTEGRALSPLICE CLIP

CROSS TEE 48" O.C. MAX,TYP., CENTERED MID PANEL

CROSS TEE

48" MAX CROSS TEE

SPACING, TYP .

48" MAX 12 GA

HANGER WIRE SPACING, TYP.

CROSS TEE

6" O.C. TORSION SPRING

PUNCHES, TYP.

PUNCHED TORSIONSPRING HOLE

HANGERWIRE HOLE

CROSS TEEHOLE

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" | .050" | .063" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LUXACOTE

PERFORATION: SEE DETAIL A1.1, TABLE 1

TEE GRID SPECIFICATIONS

PROJECT: TORSION SPRING PRODUCT SPECIFICATIONS

DRAWING NUMBER: TS-A1.3

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 2/15/2019

Page 5: B' · 2019-03-18 · detail 'b' scale: 3" = 1'-0" factory torsion spring panel end factory torsion spring panel end 12 ga hanger wire, 48" o.c. along main tee, not by hunter douglas

INTERIOR INSTALLATION

DETAIL 'B'SCALE: 3" = 1'-0"

DETAIL 'A'SCALE: 3" = 1'-0"

10'-0" WALL ANGLE TRIM PART LENGTH

BOX MOLD TRIM

0.025" ALUMINUM

MATERIAL & FINISH

TO MATCH, TYP.

1-3/

4"

1"

1" BOX MOLD,NO HOLD DOWNCLIP REQUIRED

FACTORY TORSIONSPRING PANEL END

'A'

'A'

'B'

'B'

FACTORY TORSIONSPRING PANEL END

1" BOX MOLD,NO HOLD DOWN

CLIP REQUIRED

12 GA HANGER WIRE, 48" O.C. ALONGMAIN TEE, NOT BY HUNTER DOUGLAS

MAIN TEE INBOARDOF PANEL END

TRIM SPRINGAS REQUIREDTO FIT

12 GA HANGER WIRE,48" O.C. ALONG MAIN TEE,NOT BY HUNTER DOUGLAS

12" MAX MAIN TEEOVERHANG, TYP.

NOTE:PANELS ARE INACCESSIBLEFROM BELOW AT PERIMETERTRIMS. PLEASE REFER TODETAIL A1.5 FOR TRIMLESSACCESSIBILITY.

48" MAX CROSS TEE SPACING,

CENTERED MID PANEL, TYP.

MAIN TEE

MAIN TEE

12 GA HANGER WIRE,BY OTHERS

CROSS TEE

FIELD MITER TRIMAT CORNER

CROSS TEE

TORSIONSPRING

24" X 48" TORSIONSPRING PANEL

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" | .050" | .063" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LUXACOTE

PERFORATION: SEE DETAIL A1.1, TABLE 1

WALL TRIM SPECIFICATIONS

PROJECT: TORSION SPRING PRODUCT SPECIFICATIONS

DRAWING NUMBER: TS-A1.4

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 2/15/2019

Page 6: B' · 2019-03-18 · detail 'b' scale: 3" = 1'-0" factory torsion spring panel end factory torsion spring panel end 12 ga hanger wire, 48" o.c. along main tee, not by hunter douglas

DETAIL 'B'SCALE: 3" = 1'-0"

FACTORY TORSIONSPRING PANEL END

FACTORY TORSIONSPRING PANEL END

12 GA HANGER WIRE, 48" O.C. ALONGMAIN TEE, NOT BY HUNTER DOUGLAS

MAIN TEE INBOARDOF PANEL END

TRIM SPRINGAS REQUIREDTO FIT

12 GA HANGER WIRE,48" O.C. ALONG MAIN TEE,NOT BY HUNTER DOUGLAS

12" MAX MAIN TEEOVERHANG, TYP.

DETAIL 'A'SCALE: 3" = 1'-0"

'A'

'A'

'B'

'B'

4'-0" MAX CROSS TEE SPACING,

CENTERED MID PANEL, TYP.

DOWNWARDACCESSIBLEPANEL

MAIN TEE

MAIN TEE

12 GA HANGER WIRE,BY OTHERS

CROSS TEE

CROSS TEE

TORSIONSPRING

24" X 48" TORSIONSPRING PANEL

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" | .050" | .063" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LUXACOTE

PERFORATION: SEE DETAIL A1.1, TABLE 1

CORRIDOR PANEL SPECIFICATIONS

PROJECT: TORSION SPRING PRODUCT SPECIFICATIONS

DRAWING NUMBER: TS-A1.5

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 2/15/2019

Page 7: B' · 2019-03-18 · detail 'b' scale: 3" = 1'-0" factory torsion spring panel end factory torsion spring panel end 12 ga hanger wire, 48" o.c. along main tee, not by hunter douglas

TYPICAL ISOMETRICSCALE: NOT TO SCALE

NOTE:FIXTURE OR DIFFUSER MUST BEINDEPENDENTLY SUPPORTED INACCORDANCE WITH LOCAL BUILDING CODESAND MANUFACTURER'S INSTRUCTIONS

INTERIOR INSTALLATION

48" MAX CLEAR OPENING

'A'

'A'

'B'

'B'

24" MAX CLEAR OPENING,PANEL END TO PANEL END

48" MAX CLEAR OPENING,PANEL END TO PANEL END

24" MAX CLEAR OPENING

SECTION 'B'SCALE: 3" = 1'-0"

SECTION 'A'SCALE: 3" = 1'-0"

FIXTURE INDEPENDENTLYSUPPORTED. SEE NOTE

FIXTURE INDEPENDENTLYSUPPORTED. SEE NOTE

12 GA HANGER WIRE,48" O.C. ALONG MAIN TEE,NOT BY HUNTER DOUGLAS

TORSION SPRING

MAIN TEE

TORSION SPRING

MAIN TEE

FLANGED FIXTUREREQUIRED

FULL FACTORYLENGTH PANEL

FLANGED FIXTUREREQUIRED

FULL FACTORYLENGTH PANEL

MAIN TEE

TORSION SPRING

MAIN TEE

TORSION SPRING

CROSS TEECROSS TEEFULL FACTORYLENGTH PANEL BEYOND

TORSIONSPRING

MAIN TEE

CROSS TEE

24" X 48" TORSIONSPRING PANEL

12 GA HANGER WIRE,BY OTHERS

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" | .050" | .063" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LUXACOTE

PERFORATION: SEE DETAIL A1.1, TABLE 1

2'-0" X 4'-0" FIXTURE OPENING SPECIFICATIONS

PROJECT: TORSION SPRING PRODUCT SPECIFICATIONS

DRAWING NUMBER: TS-A1.6

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 2/15/2019

Page 8: B' · 2019-03-18 · detail 'b' scale: 3" = 1'-0" factory torsion spring panel end factory torsion spring panel end 12 ga hanger wire, 48" o.c. along main tee, not by hunter douglas

TYPICAL ISOMETRICSCALE: NOT TO SCALE

INTERIOR INSTALLATION

24" PANEL WIDTH

48" PANEL LENGTH

12" WIDE

36" LONG PANEL OPENING, TYP.

'B'

'B'

'A'

'A'

NOTE:FIXTURE OR DIFFUSER MUST BEINDEPENDENTLY SUPPORTED INACCORDANCE WITH LOCAL BUILDING CODESAND MANUFACTURER'S INSTRUCTIONS

SECTION 'B'SCALE: 3" = 1'-0"

SECTION 'A'SCALE: 3" = 1'-0"

TORSION SPRING

MAIN TEE

12" FIXTUREOPENING

MAIN TEE

TORSION SPRING

24" PANEL WIDTH

36" FIXTUREOPENING

48" PANEL LENGTH

FIXTURE INDEPENDENTLYSUPPORTED. SEE NOTE

FIELD CUT PANEL FOR FIXTURELENGTH, AS REQUIRED

FIELD CUT PANEL FOR FIXTURELENGTH, AS REQUIRED

6" MAX FROMPANEL EDGE

FLANGED FIXTUREREQUIRED

6" MAX FROMPANEL EDGE

12 GA HANGER WIRE, 48" O.C. ALONGMAIN TEE, NOT BY HUNTER DOUGLAS

MAIN TEE

TORSION SPRING

FIXTURE INDEPENDENTLYSUPPORTED. SEE NOTE

TORSION SPRING

MAIN TEE

FULL FACTORYLENGTH PANEL BEYOND

FLANGED FIXTUREREQUIRED

6" MAX

6" MAX

TORSIONSPRING

MAIN TEE

CROSS TEE

24" X 48" TORSIONSPRING PANEL

12 GA HANGER WIRE,BY OTHERS

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" | .050" | .063" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LUXACOTE

PERFORATION: SEE DETAIL A1.1, TABLE 1

FIELD CUT PANEL OPENING SPECIFICATIONS

PROJECT: TORSION SPRING PRODUCT SPECIFICATIONS

DRAWING NUMBER: TS-A1.7

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 2/15/2019

Page 9: B' · 2019-03-18 · detail 'b' scale: 3" = 1'-0" factory torsion spring panel end factory torsion spring panel end 12 ga hanger wire, 48" o.c. along main tee, not by hunter douglas

LATERAL BRACING: BRACE WITH HANGER WIRES AND STRUTS PER ASTM E-580 AND IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS.

(4) #12 GAUGE WIRES SPLAYED 90° FROM EACH OTHER AT ANGLE NOT EXCEEDING 45° FROMPLANE OF CEILING. A STRUT FASTENED TO MAIN RUNNER SHALL BE EXTENDED TO ANDFASTENED TO STRUCTURE ABOVE. SPLAYED WIRE AND STRUT BRACING TO BE PLACED NOTMORE THAN 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 6 FEETFROM EACH WALL.

INTERIOR INSTALLATION

45° COMPRESSION STRUT

45°

45°

45°

S

N

N

SW

E

SPLAYED 12 GA HANGERWIRE, BY OTHERS, TYP.

SECTION 'A'SCALE: 6" = 1'-0"

'A'

'A'

E

W

1/2" X 1-1/2"16 GA CR CHANNEL,BY OTHERS

#8 X 12 HEX HEADSELF DRILL SCREWS(4 PLACES),BY OTHERS

TORSION SPRING

BAC CLIP

MAIN TEEFACTORY LENGTHTORSION SPRING PANEL

BAC CLIP

TORSIONSPRING

CROSS TEE

MAIN TEE

CROSS TEE

5015 Oakbrook Parkway, Suite 100

Norcross, GA 30093

O 800.366.4327

F 770.806.0214

CTSpecialtyCeilings.com

All r ights reserved. This

drawing is the proper ty

of CertainTeed Ceilings

Corporation. It may not

be copied or mult ipl ied,

n e i t h e r w h o l l y n o r

par t l y . I t may not be

submitted f or perusal to

t h i r d p a r t i e s .

SPECIFICATIONS

(unless noted otherwise)

MATERIAL: .032" | .040" | .050" | .063" ALUMINUM

FINISH: PAINT | POWDER COAT | DECORATED WOOD FINISH | LUXACOTE

PERFORATION: SEE DETAIL A1.1, TABLE 1

SEISMIC SPECIFICATIONS

PROJECT: TORSION SPRING PRODUCT SPECIFICATIONS

DRAWING NUMBER: TS-A1.8

SCALE: AS SHOWN

DRAWN BY: HD ENGINEERING

DATE: 2/15/2019