b. david company 4000 nanotechnology certified filtration
TRANSCRIPT
Howtoinstall,operateandmaintainyourMicrobiologicalDrinkingWaterPurifier
ManufacturedbyB.DavidCompany9333SheridanAvenueSouth*Bloomington,MN55431
(952) 884-8417*[email protected]
Installatio
nandOperatio
nManual
SystemtestedandcertifiedtomeettherequirementsofNSFProtocolP231and
NSF/ANSIStandards42&53.Seeperformancedatasheetfordetails.
4000NanotechnologyCertifiedUnderCounter
FiltrationSystem
Rev:04/28/2016
TABLEOFCONTENTSPage
WhattheMicrobiologicalDrinkingWaterPurifierWillDo...................................................3BeforeYouStart.....................................................................................3Precautions.........................................................................................3Specifications&Dimensions...........................................................................3PartsoftheSystem...................................................................................4Materials&ToolsNeeded.............................................................................4InstallationInstructions.............................................................................4-6 Step1–InstallingtheSaddleValve.............................................................4 Step2–SelectingtheFaucetLocation...........................................................5 Step3–MountingtheFaucet.................................................................5 Step4–MountingtheSystem.................................................................5 Step5–ConnectingtheFaucet................................................................5Step6–AttachingTube......................................................................6 Step7-ConnectingtheSaddleValve...........................................................6 Step8–ConnectingtheInletLinetoSystem....................................................6 Step9–SettingtheEffectiveLifeIndicator.....................................................6 Step10–PuttingtheSystemintoOperation....................................................6FilterCartridges.....................................................................................7FilterCartridgeLife..................................................................................7 FilterCartridgeReplacement..................................................................7TroubleshootingtheSystem..........................................................................8PartsList...........................................................................................8ExplodedView&PartsList...........................................................................9
WARRANTYONEYEARLIMITEDWARRANTYONMICROBIOLOGICALDRINKINGWATERPURIFIER
Warrantor:B.DavidCompany,9333SheridanAve.S.,Bloomington,MN55431B.DavidCompanywarrantstotheoriginalowner(undernormaluse):allproductsandpartstobefreefromdefectsinmaterialandworkmanshipforaperiodofone(1)yearfromthedateofpurchase.Anyreplacementproductsfurnishedwillbefreefromdefectsinmaterialand/orworkmanshipfortheremainderoftheoriginalwarrantyperiodor30days,whicheverislonger.Thiswarrantydoesnotcover:(1)defectsnotreportedwithintheabovetimeperiod,(2)problemsarisingfromfailuretocomplywithB.DavidCompanyinstructions,(3)problemsand/ordamagearisingfromactsofnature,abuse,misuse,negligenceoraccidentbyanypartyotherthanB.DavidCompany,(4)problemsand/ordamageresultinginwholeorinpartfromalteration,modification,repairorattemptedalteration,modificationorrepairbyanypartyotherthanB.DavidCompany,(5)noncompliancewithapplicablecodes/ordinances.Ifadefectinworkmanshipand/ormaterialinaproductorpartcoveredbythewarrantyshouldarise,B.DavidCompany,atitssolediscretion,willrepairorreplacethedefectiveproductorpart(B.DavidCompanywillconsiderthecustomer’spreferenceingoodfaith).Allclaimeddefectiveproductmust:(1)beauthorizedforreturnbyB.DavidCompanywithanRGAnumber(2)includeproofofthepurchasedateoftheproductorpart(3)returnedtoB.DavidCompanypriortotheexpirationofthewarrantydateatthecustomer’sexpense,shipmentpre-paid(4)beaccompaniedbyaletterdetailingtheModelNumber,SerialNumber(ifany),andabriefdescriptionoftheproblem.TOTHEMAXIMUMEXTENTPERMITTEDBYAPPLICABLELAW,B.DAVIDCOMPANYDISCLAIMSALLOTHERWARRANTIES,WHETHEREXPRESSORIMPLIED,INCLUDING,BUTNOTLIMITEDTOTHEIMPLIEDWARRANTYOFMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE,WITHREGARDTOTHEPRODUCTS,PARTSANDANYACCOMPANYINGWRITTENMATERIALS.Tothemaximumextentpermittedbyapplicablelaw,B.DavidCompanyshallnotbeliableforanydamageswhatsoever(including,butnotlimitedto,lossoftime,inconvenience,expenses,laborormaterialchargesincurredinconnectionwiththeremovalorreplacementoftheproductsorparts,special,incidental,consequential,orindirectdamagesforpersonalinjury,lossofbusinessprofits,businessinterruption,lossofbusinessinformation,oranyotherpecuniaryloss)arisingoutoftheuseoforinabilitytousethedefectiveproductsorpartsevenifB.DavidCompanyhasbeenadvisedofthepossibilityofsuchdamages.TheB.DavidCompanymaximumliabilityunderanyprovisionofthisLimitedWarrantyshallbelimitedtotheamountactuallypaidfortheproductsorparts.ThiswarrantyiseffectiveiftheMicrobiologicalDrinkingWaterPurifierisoperatedatwaterpressuredbetween30-100psigandawatertemperaturebetween40-100°F.Furthermore,thepurifiermustnotbesubjecttomistreatment,systemmodification,disregard,freezing,carelessness,ordamageasaresultofanyunusualforceofnature(i.e.hurricane,flood,earthquake,ortornado).Warrantorisexcusediffailuretoperformitswarrantyobligationsistheresultofmaterialshortages,governmentregulation,strikes,oranyothercircumstancesbeyonditscontrol.
WhattheDrinkingWaterPurifierWillDo
The4000NanotechnologyCertifiedUnderCounterFiltrationSystemisawaterpurificationtreatmentsystem.Thissystemusesatriplefilterdesigntoreduceunwantedelementsinyourdrinkingwater.Possibleelementsmayincludechlorine,lead,virus,bacteria,cysts,particulatesandnumerousorganiccompounds.
The4000NanotechnologyCertifiedUnderCounterFiltrationSystemutilizesthepatentedNanoandothertechnologiesinasystematicapproachtoensurethewatersupplyconformstoEPAGuideStandardfortheremovalof99.9999%Bacteria,99.99%Viruses,and99.95%Cysts.The4000NanotechnologyCertifiedUnderCounterFiltrationSystemisdesignedtodiscontinuewaterflowwhenitscapabilitytofilterunwantedelementshasbeenexhausted.Thiswillhelpsafeguardtheconsumeragainstcontaminatedwater.Replaceallfiltersevery12monthsor1000gallons.
NOTE:Aperformancedatasheetisincludedandlistswhatelementswillbereducedfromthewatersupply.(Pleasenotethatnotallelementsmaybepresent.)Thisdatasheetliststheindividualcontaminantsandmicrobialreductionperformance.
Thedrinkingwaterpurifiersystemisdesignedtofitunderthekitchenorbathroomsinkoranyotherareathatissuitable.ACOLDwatersupplypipeisrequiredwithinafewfeet.Ifwatersupplypipeisfartherthanwhatthetubewillreach,youcanpurchaselongerlengthsoftubingfromyourlocalhomeimprovementcenter.
NOTE:Makesurethetubingisacceptableforuseonpotablewatersupplies.
BeforeYouStart
v Inordertoreceiveallofthebenefitsofyourmicrobiologicaldrinkingwaterpurifier,besuretoreadallstepsinthisguidecarefullyandfollowstepsexactly.
v Thissystemisintendedforusewithmunicipaland/orwell-suppliedwateronly.Itisnotintendedforusewithsurfacewatersuchasfromalakeorrunoff.
v Donotuseforthetreatmentofwaterthatisvisuallycontaminated(cloudy)orhasanobviouscontaminationsource,suchascontaminationbyrawsewage.
v Systemscertifiedforcystreductionmaybeusedondisinfectedwatersthatmaycontainfilterablecysts.v Systemisnotintendedtoconvertwastewaterorrawsewageintodrinkingwater.v Installationandplumbingshouldcomplywithalllocallawsandregulations.Consultwithyourlicensedplumber.
NOTE:InMassachusetts,plumbingcode248CMR3.00and10.00shallbeadheredto.v Themicrobiologicaldrinkingwaterpurifierworksonwaterpressureof30psig(minimum)to100psig(maximum).Ifyourhouse
waterpressureisoverthemaximum,installapressurereducingvalveinthewatersupplypipetothefiltersystem.v Donotinstallthemicrobiologicaldrinkingwaterpurifieroutside,orinextremehotorcoldtemperatures.Temperatureofthe
watersupplytotheunder-sinkdrinkingwaterfiltersystemmustbebetween40◦Fand100◦F.Donotinstallonhotwater.v Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutdisinfectionbeforeorafterthesystem.v Systemscertifiedforcystreductionmaybeusedondisinfectedwatersthatmaycontainfilterablecysts.
Precautions
• Thissystemisfor“coldwater”useonly.• Protectfiltersagainstfreezing,whichcancausecrackingofthefilterandwaterleakage.• TherubberO-ringprovidesthewater-tightsealbetweenthecapandthebottomofthehousing.Itisimportantthatthe
O-ringbeproperlyseatedinthegroovebelowthethreadsofthehousingorawaterleakcouldoccur.• Topreventcostlyrepairsorpossiblewaterdamage,thesumpofplastichousingsmustbereplacedeverytenyears.Ifsumpis
olderthanrecommended,replaceimmediately.Datesumpforreferenceandindicatereplacementdate.
Specifications&Dimensions
SupplyWaterPressure..........30–100psigMin-Max(2.1-6.7bar)
SupplyWaterTemperature........40-100◦FMin.–Max.(4.4–37.8◦C) ServiceFlowRate@60psig...............([email protected])RatedServiceLife.....1000gallons(3,785L) Dimensions..........15.5”Hx5.25”Dx14”L (394mmx133mmx356mm)Weight........(filledwithwater)19lbs(8.6kg)
PartsoftheSystem
●Filtersystemwithfiltercartridges●Installationhardware(mountingscrews,saddlevalve,flowrestrictor,fittings)●1/4-inch(6.35mm)tubing●Lead-freefaucet
MaterialsandToolsNeeded
Note:Gathertherequiredtoolsbeforestartinginstallation.Readandfollowtheinstructionsprovidedwithanytoolslistedhere.• Safetyglasses• Handorelectricdrill(cordlessrecommended)• Fileorsandpaper• PhillipsHeadscrewdriver• 2adjustablewrenches• Tubecuttersorutilityknife**Ifsinkdoesnothaveholeforseparatefaucet:• Centerpunch• 3/4-inch(19mm)drillbit• MaskingtapeIMPORTANT:Toavoiddamagingthesink,consultaqualifiedplumberorinstallerfordrillingproceduresinporcelain,granite,orstainlesssteel.
InstallationInstructionsNOTE:Asqueakingsoundwhentighteningacompressionnutisnormal.NOTE:Iffittingsareremoved,Teflon®tapemustbeusedforpipethreadedconnections.NOTE:Besuretowearsafetyglasseswhenusingadrill.
• Systemisdesignedforstandardunder-sinkinstallationon3/8”-inch(10mm)coldwaterline.• Numbereddiagramscorrespondwithnumberedsteps.
Step1–InstallingtheSaddleValve
Useofacordlessdrillisrecommended.Toprotectyourselffromseriousinjuryorfatalshockwhenusinganelectricdrill,besurethedrillandtheoutletitispluggedintoareproperlygrounded.Whenusingadrill,followthemanufacturer’sguidelinesandprocedures.NOTE:Saddlevalvemustbeinstalledona2-inch(51mm)long,straight-walledsectionof
3/8-inchto7/8-inch(10-22mm)steel,brass,copper,orPVCpipea) Turnoffcoldwatersupplyandturnonnearestfaucetbeforestartinginstallation.
Placeatrayortowelsunderthecoldwaterlinetocatchexcesswater.b) Drilla1/8-inch(3mm)holeinthecoldwaterline.Removeanyburrswithsandpaper
orfile.c) Turnhandleonthesaddlevalvetoexposelancenomorethan3/16-inch(5mm)
aboveblackrubbergasket.d) Placevalvebodyoverholeincoldwaterlinesolancefitsintohole.e) Attachbackplateofclampandtightenboltsevenlyandfirmlysobracketsareparallel.f) Turnvalvehandleclockwisetoclosedpositionandleavecloseduntilinstallationiscompete.
NOTE:Allnutsmustberetightenedwhenthesystemreachesprojectedoperatingtemperature.
InstallationInstructions
Step2–SelectingtheFaucetLocation
NOTE:Thedrinkingwaterfaucetshouldbepositionedwithfunction,convenience,andappearanceinmind.Anadequateflatareaisrequiredtoallowfaucetbasetorestsecurely.Thefaucetfitsthrougha3/4-inch(19mm)hole.Mostsinkshavepre-drilled1-inch(35or38mm)diameterholesthatmaybeusedforfaucet.
a) Linebottomofsinkwithnewspapertopreventmetalshavings,parts,ortoolsfromfallingdowndrain.
b) Placemaskingtapeovertheareatobedrilledtopreventscratchesifdrillbitslips.IMPORTANT:Toavoiddamagingthesink,consultaqualifiedplumberorinstallerfordrillingproceduresinporcelain,granite,orstainlesssteel.
c) Markholewithcenterpunch.Usea1/4-inch(6mm)drillbitforapilothole,then,usinga3/4-inch(13mm)drillbitorholesaw,drillaholecompletelythroughthesink.Smoothroughedgeswithafile.
Step3–MountingtheFauceta) Removewingnut(C)andmetalwasher(B)fromthethreadedshaftofthefaucet.Leave
theblackrubberwasher(A)onthethreadedshaft.b) Slidethethreadedshaftofthefaucetintodrilledhole.c) Fromunderthesink,slidethemetalwasheronandthreadonthewingnut.
Tightenwingnutbyhanduntiltight.Itmaybenecessarytohaveasecondpersonholdthefaucetwhiletighteningthewingnut.
d) Installthefaucetspoutintothebasebypushingfirmlyintoholeinbasethenscrewfittingcoverhandtight.
Caution:Donotover-tightenthewingnut.Handtightenonly.Donotusepliersorwrenchtotighten.Step4–Mountingthesystem
a) Centersystembetweenwatersupplyadapteranddrinkingwaterfaucet.NOTE:Allow1.5inches(38mm)clearancebelowsystemtoenablefiltercartridgechanges.
NOTE:Inthefollowingstep,leaveenoughspace(approximately1/2-inch(13mm))betweentheheadofthescrewandthewalltoeasilyslipsystemintoplace.
b) Installmountingscrewsatleast15-inches(380mm)fromcabinetfloorand91/4-inches(235mm)apart.Placesystemoverscrewsonwallandslidesideways.Tightenscrews.
Caution:Makecertainsystemisfirmlyattachedtowalltopreventpossibledamagefromfalling.
Step5–ConnectingTubingtotheFaucetCaution:Donotover-tightencompressionnut.Usecautionnottobendorcrimptubeswhensecuring.
a) Locatecompressionnutininstallationkitandfaucetpackage.b) Attachcompressionnutpieces(3)tooneendoftubing.
Caution:Tubemustbefullyinsertedinthecompressionfittingbasetothetubestoponthefaucetstem.
c) Attachtubewithcompressionnutassemblytofaucetstembyinsertingtubeintothefaucetstemopening.Gentlypushthetubinguntilitcomestoastop.
NOTE:Allnutsmustberetightenedwhenthesystemreachesprojectedoperatingtemperature.
InstallationInstructions
Step6–AttachingTubetoEffectiveLifeIndicator(ELI)a) DeterminethelengthoftubingneededfromthefaucettotheELI.Aslightsaginthe
linewillallowforsomeeaseininstallation.Cutthetubingtorequiredlength.b) Insertotherendoftubingfirmlyintotheoutletport(JohnGuest®fitting)oftheELI
untilfullyengaged.c) Pulltubegentlytoensurethetubingisfullyseated.
Caution:TubemustbefullyinsertedinthecompressionfittingbaseontheoutletstemoftheELI.
Step7–ConnectingtheSaddleValvea) Determinethelengthofplastictubingneededtoconnecttheinlet(left)sideofthefilter
withthesaddlevalve.Besuretoallowenoughtubingtopreventkinkingandcutthetubingsquarely.Slidebrasscompressionnutontotubing,followedbyplasticferrule.Thelongtaperedendoftheferruleshouldfacetowardstheendofthetubing.Placeinsertintotubing.
b) Inserttubingintosaddlevalveandhand-tightencompressionnut.Usingawrench,tightennut1to1½turns.
NOTE:Allnutsmustberetightenedwhenthesystemreachesprojectedoperatingtemperature.
Step8–ConnectingInletLinetoSystema) Insertotherendoftubingfirmlyintoinletport(JohnGuest®fitting)untilfullyengaged.b) Pulltubegentlytoensurethetubingisfullyseated.
Step9–SettingtheEffectiveLifeIndicatorNOTE:Theeffectivelifeindicatoristhewhitediallocatedonthecenterofthe
mountingbracket. Eachblackmarkonthedialrepresents100gallons(378.5L).a) Movethedialclockwisesothattheblackindicatorarrowlinesupwiththe1100gallon
(4,164L)mark.Important:Setflowmeterto1100gallonsaftereachnewfilterreplacement.NOTE:Topreventindicatormalfunctions,onlymovethedialwhenthesystemisdepressurized.
Step10–PuttingtheSystemintoOperationa) Slowlyturnoncoldwatersupply.b) Rotatehandleonbaseofdrinkingwaterfaucetcounter-clockwiseto“ON”position.
Allowwatertorunfor10minutestoflushairandcarbonfinesfromfiltercartridges.Checksystemforleaksbeforecompletinginstallation.
c) Makesurethatallnutsaretightened.NOTE:Adrinkingwatercartridgemaycontaincarbonfines(veryfineblackpowder).Itisrecommendedthatyourunthetapatleast20secondspriortousingwaterfordrinkingorcookingpurposes.NOTE:Initially,filteredwatermayappearcloudy.Ifyousetaglassofwateronalevelsurface,youshouldbeabletowatchthecloudinessdisappearfromthebottomoftheglassupwards.Thisharmlesscloudinessresultsfromthereleaseoftrappedairwiththecartridgeandwilldisappearwithinafewweeksafterinstallation.
INSTALLATIONISNOWCOMPLETE.
NOTE: Based on the settings sensitivity of the Effective Life Indicator (ELI), user should set the ELI to 1,100 gallons to assure a 1,000 gallon cycle.
FilterCartridges
FilterCartridgeLife
Itisrecommendedtoreplace filter cartridges every 12 months or 1,000 gallons ofuse.However,yourwaterqualitycanleadtocircumstancessuchasdiminishedwaterflow,visiblesediment,orunwantedtasteand/orodorinyourwater,requiringthecartridgesbereplacedsooner.
NOTE: Based on the settings sensitivity of the Effective Life Indicator (ELI), user should set the ELI to 1,100 gallons to assure a 1,000 gallon cycle.
Thereareseveralvariablesthatdeterminehowlongacartridgewilllast.Theseinclude:
1. Howmuchwateryouuse,and2. Howmuchsediment,chlorine,orotherunwantedsubstancesisinthewater.
FilterCartridgeReplacement
NOTE:Contactyoursystemsupplierforreplacementfilterparts.
1. Turnoffcoldwatersupplytosystemandturnonfaucettoreleasepressure.NOTE:Due to water leakage, place pan or towel under sump.
2. Unscrewandremovebottomoffilterhousing.LocateandremovelargeO-ring,wipecleanoflubricant,andsetaside. Repeatforsecondandthirdhousings.
3. Discardusedfiltercartridges.
Caution: Read "WARNING" information on the bleach container before using.
4. Usinganon-abrasivespongeorcloth,scrubthebottomofeachhousing,O-ringgrooves,andcapswithdishsoapand warmwater.Rinsethoroughly.Thenfillbottomofeachhousing1/3fullwithwater.Add1TBSP(14.7ML)of householdbleachandscrubtodisinfect.
5. LubricateO-ringswithcleansiliconegrease.InserteachO-ringingrooveandpressintoplace.NOTE:Thisstepisimportanttoensureaproperhousingseal.MakecertaineachO-ringisseatedlevelinitsgrooveor aleakmayoccur.
6. Screwbottomofhousing(s)withbleachwaterontocap(s)withoutfiltercartridge(s)andhand-tighten.DO NOT OVER-TIGHTEN.
7. Turnonwatersupply.Letfaucetrunforabout10seconds,thenturnofffaucetandletstandfor20-30minutes.8. Turnonfaucetandallowbleachwatertorunout(about3-5minutes)9. Turnoffwatersupplytosystem.Removebottomofhousingsandemptyoutwater.10. Inserteachfiltercartridgeinbottomofappropriatefilterhousing.
IMPORTANT:Be sure to remove any protective covering from the filters before inserting.11. Screwbottomofhousing(s)ontocap(s)andhand-tighten.DO NOT OVER-TIGHTEN.Makecertaincapstandpipeslips
intocartridge(s).
12. Reseteffectivelifeindicatorto1,100gallons(seeinstructionunder“SettingEffectiveLifeIndicator”onPage6.)13. Turnonwatertosystem.Letfaucetrunfor10minutestoremovetrappedairandcarbonfines.Checksystemfor
leaks.
REPLACEMENTFILTERS(40103-Pack)
4001FirstStageNanoFilter
4002SecondStageFIFilter
4003ThirdStageDEBlock
TroubleshootingtheSystemProblem: Leaksbetweencapandbottomoffilterhousing Correction: Turnoffwatersupplyandturnondrinkingwaterfaucettoreleasepressurein
system.Removebottomofhousing.CleanO-ringgroove(locateddirectlybeneaththreadsofhousing).LubricateO-ringwithsiliconegreaseandreplacesecurelyintogroove.Screwbottomofhousingontocapandhand-tighten.DONOTOVER-TIGHTEN.Turnonwatersupplyandcheckforleaks
Problem: Leaksonsysteminlet/outletconnections Correction: Turnoffwatersupplyandturnondrinkingwaterfaucettoreleasepressureinsystem.Removetubingfromfittingandmakesureendoftubingiscutsquarelyandfreeofburrs.Reinserttubingintofitting,makingsuretopushtubingtoahardstop.Hand-tightencompressionnutfirst,thentighten1to11/2turnsfornewcompressionnut.Tightenonly1/2to1turnwithwrenchforpreviouslytightenedcompressionnut.NOTE:Ifleakspersist,orifthereareotherleaksinsystem,turnoffwatersupply.
Problem: Leaksonfaucet/tubingconnection Correction: Turnoffwatersupplyandturnondrinkingwaterfaucettoreleasepressureinsystem.Loosenandremovecompressionnutfittingonfaucetstem.Makesuretubingisinsertedfirmlyintoendoffaucetstem,thenretightencompressionnutwithfingersuntilsecure.Turnonsaddlevalve,andthenturnofffaucettocheckforleaks.NOTE:Ifleakspersist,orifthereareotherleaksinsystem,turnoffwatersupply.
Problem: Nowaterordecreasedwaterflow. Correction: Checkflowatfaucet.The4000NanotechnologyCertifiedUnderCounterFiltrationSystemsystemshouldfillagallonjuginapproximately2minutes.Flowrateswillvarywithindividualhouseholdwaterpressure.
Correction: Checkfiltercartridgeinstallation.Makecertainallfiltercartridgesareproperlyorientedinfilterhousings.
Correction: Replacefiltercartridges.
PartsListITEM# QTY PART# DESCRIPTION ITEM# QTY PART# DESCRIPTION
11 4002991 MTGBRACKET,3HOUSINGWHITE 15 1 4003 THIRDSTAGEDEBLOCK
1 144169-02MTGBRACKET,3HOUSINGWHITE(ALTERNATIVE) 16 1 4002 SECONDSTAGEFIFILTER
2 2 SH244788 ELBOW,1/4"NPTX1/4"QCWHPP 17 1 4001 FIRSTSTAGENANOFILTER
3 2 SH244791 NIPPLE,MALEHEX1/4"NPTX1/4"NPT 20 2 161123 FILTERTIMERMONITOR,12MONTH
4 3 158125 1/4"#10SLWHITEWO/PR12/C 21 1 161125 INSTRUCTIONSHEET,TIMESTRIP
5 4 SH143263 SCREW#6X1/4"LGPHILPAN 220.0240RL SH144223 MACHINETAPE,TEFLON1/4"WIDE
6 1 42561 LUBRICANT,SILICONE,PACKET 25 1 1611161
MANUAL,B.DAVIDCOMPANY4000NANOTECHNOLOGYCERTIFIEDUNDERCOUNTERFILTRATIONSYSTEM
7 1 150539 WRENCHSW-1A 2610.000FT SH243244 TUBE,1/4"ODWHITEPE
8 12 PW-80-09 SCREW,#10-32X3/4"PANHEAD 27 2 161143 DMFITTING;1/4"X1/4"QC;NPT
9 1 4002987 VALVE,SADDLE1/4COMPRESSION 24 N/A
10 2 SH243249 SCREW#10-12X1.5TYPEA 320.1250FT SH243244 TUBE,1/4"ODWHITEPE
11 3 C143026 LOCAL"O-RING" 330.4583FT SH243244 TUBE,1/4"ODWHITEPE
13 2 244960 DEFENGFAUCET,STANDARD 34 1 244985 INLINEFLOWRESTRICTOR,0.5GPM
14 1 161127 METER,1800GALLON,1/4NPT