Barcode-Scanner Barcode Scanner Barcode Scanner Barcode Scanner Barcode Scanner Operation Manual This equipment has been tested and found comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interface when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interface to radio communications. Operation of this equipment in a residential area is likely to cause harmful interface in which case the user will be required to correct the interface at his own expense. This device complies with part 15 of the FCC Rules. Operation is subject to the following two condition: (1) This device may not cause harmful interface, and (2) This device must accept any interface received, including Interface that may cause undesired operation.

Upload: duongdieu

Post on 11-May-2018

232 views

Category:

Documents


1 download

TRANSCRIPT

Barcode-Scanner

Barcode ScannerBarcode ScannerBarcode ScannerBarcode Scanner

Operation Manual

This equipment has been tested and found comply with

the limits for a Class A digital device, pursuant to part 15

of the FCC Rules. These limits are designed to provide

reasonable protection against harmful interface when

the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio

frequency energy and, if not installed and used in

accordance with the instruction manual, may cause

harmful interface to radio communications. Operation of

this equipment in a residential area is likely to cause

harmful interface in which case the user will be required

to correct the interface at his own expense.

This device complies with part 15 of the FCC

Rules. Operation is subject to the following two

condition: (1) This device may not cause harmful

interface, and (2) This device must accept any

interface received, including Interface that may

cause undesired operation.

1 Index

Installation............................................ 2

Comment .............................................. 3

Frequency Question............................ 7

Interface................................................ 9

Keyboard .............................................. 10

RS-232C................................................ 12

Wand Emulation................................... 14

OCIA...................................................... 15

System Control .................................... 16

UPC-A ................................................... 19

UPC-E.................................................... 20

EAN-13.................................................. 21

EAN-8.................................................... 22

Code-39 ................................................ 23

Interleaved 2 of 5 ................................. 24

Industrial 2 of 5 .................................... 25

Matrix 2 of 5.......................................... 26

Codabar/NW7 ....................................... 27

Code-128 .............................................. 29

Code-93 ................................................ 30

Code-11................................................. 31

MSI/Plessey.......................................... 32

UK/Plessey ........................................... 33

Preamble/Postamble ........................... 34

ASCII Code Table................................. 35

Hexdecimal/Decimal Table.................. 36

Installation 2

Installation 1) First of all, you must make sure that the power is

disconnected form your equipment before connecting

the scanner. Beside, you also have to check the

cable connector of the scanner match your

equipment interface correctly.

2) Boot up your computer after connecting the scanner

with your equipment, the scanner will make a long

music and light the LED, above scanner to indicate a

successful power on. Trigger the button, the scan

line in front of scanner will active. Now you can start

to set programming optimal usage.

Recommened Steps When the required settings have been configured,

all settings are stored in non volatile memory of scanner

after reading EXIT label. There are recommended steps

as follows.

1) Set right interface of scanner for your host at �9.

First time, you may ignore it unless you want to

change the scanner into other interface usage.

2) Set interface protocol to optimize of scanner with

your host.

3) Set system control of scanner, such as specific

adjustments, indicator, scanning mode, code ID and

code name transmission which you prefer usage in

system Control at �16.

4) Set code option of scanner for your usage. You must

make sure to enable the symbology first, then

Min./Max. code length, code ID, checksum and

truncate digits are also convered.

5) Set string format of the scanner, such as preamble,

postamble, prefix, suffix, for your application at

�33.

3 Comment

Numeric Key Position

This function is only available for IBM PC/AT, PS/2,IBM

5576 series personal computers and compatible

machines. The case of Keypad selected enables

numeric output as keypad output (Num Lock On).

Function Key Emulation

This function is only available for IBM computer

compatible machines. When the function is enabled, the

ASCII code values that are between 1 to 1BH will be

changed all characters (which can be used for the

RS-232 communication protocol) to the Function Keys

in the transmitted data. The conversion process

includes Preamble/Postamble, Prefix/Suffix codes

programmed.

Keyboard Simulation

All of the PCs will be check each devices (include

keyboard interface) by themselves while the host

computers power ON. If the feature is enabled, it can

pass the keyboard installation checking by host

computer while power ON. It is recommended to

program the function to enable without keyboard

installation.

Caps Lock

The Print-Case is related with "Caps Lock" status.

When Upper case is select and "Caps Lock On" or

Lower case is select and "Caps Lock Off" the output

style accord with on the character case.

Case Conversion

This function of selected can force to output all

characters converter to the same case (upper or lower).

Inter-Char. Delay (Set value)

It is a time delay between data characters output. An

Inter-Character Delay Timer ranges from 0 - 99 ms can

be used to match various host computer or terminal

response time. Adjust this timer and try out the shortest

delay time that until works properly.

Transmit Delay (Set value)

It is a time delay between barcode data output. The

feature will be used for shorter barcode data output or

multi-field scanning.

Comment 4

Response Delay (Set value)

The time out is a pre-defined delay time for serial

communication of scanner to wait for handshaking,

acknowledgment or non-acknowledgment from the host

computer. When the time out occurs, the scanner will

issue 5 warning beeps. The feature is particularly useful

for some applications in which the host computer takes

a longer time to respond with a matchable signal.

Code-39 Emulation

The feature is able to translate all barcode symbols (as

the scanner can support as standard Code-39 Wand

emulation output for your decoder device.

Power-on Auto Trigger

The feature can auto trigger the bottom of scanner to

activate the light source after the successful start beep.

Field Control

The scanner can read-out many sets of barcode data

on the same scanning line in the same time if

Multi-Field of Field Control were selected. The direction

of read-out code is from left to right even different type

symbol code.

Double Confirm

The feature should be depended on the symbol and

quality of barcodes reading. If the enabled to be

selected, the scanner will require many times

successful decoding to valid-data the barcode data. The

value of confirms time can be set by Double Confirm

Times function, and the more confirm times the more

inhibitive miss-reading code. Therefore you select a

higher value then read-out speed reducing.

Code Name Transmission

The feature is useful to show unknown barcode symbol,

which include the readable barcode symbol of scanner.

When the enable is selected, the symbol code name

will be shown before the code data.

Code ID Position

The code ID can be transmitted before or after the code

data by this selected when Code ID Transmit enabled.

Normally, the position is before the code data.

Comment 5

Code Length Transmission

The length of data characters can be transmitted before

the code data when the enable is selected. The total

length is a number of barcode data except Truncate

Leading/Ending Digits. The Code Length has two digits.

Double Confirm Times (Set value)

This feature should be selected according to the symbol

and the quality of barcodes being read. The value of

time is successful decoding to validate the barcode data

times. When the more value is set, the more slowly

reading speed and the more higher data security.

Min./Max. Code Length (Set value)

A Min. and Max. length ranging form 1 to 48 can be set to

qualify data entry. (Return to default value if it is set to be "0".)

The length is defined to be the actual barcode data length sent.

Label with length exceeds these limits will be rejected. Make

sure that the Minimum length setting is no greater than the Max.

length setting, or all the labels of the symbol will not be read. In

particular, you can set the same value for both Min. and Max.

reading length to force the fixed length barcode decoded. The

values of setting can not effect in some fixed length labels of

symbol (i.e. UPC/EAN/JAN call WPC).

Add-on Lock with WPC

The ADD-ON barcode is the supplemental code and often

present the 2 or 5 supplement digits with WPC. The feature will

force output the ADD-ON code together in reading WPC with

ADD-ON symbol barcode if ADD-ON Lock is enabled. Therefore

it can not read the WPC barcode without ADD-ON. It is

recommended to program the ADD-ON to be enabled while the

ADD-ON code must be read out.

Expansion

The expansion of function is used only for UPC-E and

EAN-8 code reading, It can extend to 13-digit with

leading "0" numeric system when the feature is

enabled.

Truncate Leading Zeroes

The leading "0" digits of barcode data characters can be

truncated when the function is enabled. The feature is

used only for WPC code reading.

Comment 6

ISBN/ISSN Translation

The ISBN (International Standard Book Number) and

ISSN (International Standard Serial Number) are two

kinds of barcode bookend label. The ISBN is a 10 digits

with leading "978" and the ISSN is a 8 digits with

leading "977" of the "EAN-13" symbol code.

Truncate Leading/Ending Digits (Set value)

The leading or ending digits of barcode data characters

can be truncated when the values of settings are not

zero. It will be read nothing else only beep when the

Truncate value is more than barcode data digits or the

value of Truncate Leading is overlap with the Ending.

The maximum value of Truncate digits is 15.

Code ID (Set value)

A Code ID is a character that used to represent the

symbol begins decoded upon succeeding reading. The

code ID is prefixed to the data begins or tail transmitted

if the feature is selected. There are some labels of

symbol (i.e. UPCE and EAN-8) include 2 Code IDs.

Code-32 (Italian Pharmac.) Format

The Code -32 symbol is an another version of Code-32

that is a barcode data from digit 0 to 9. The leading A is

an optional character that can be allowed to transmit or

not.

Preamble/Postamble Transmission (Set value)

There are two characters (Data0 and Data1) could be

programmed for both Preamble and Postamble data

(include the Function Key Emulation). They can be

automatically appended to the data transmitted when

each barcode is decoded.

Prefix/Suffix Transmission (Set value)

Up to 15 characters could be programmed for both

Prefix and Suffix data. The Prefix data programmed will

be placed after Preamble data and before the barcode

data, and the Suffix data programmed will be placed

after the barcode data and before the postamble data.

7 Frequent Question

Q: Why scanner block the keyboard operation?

A: Check the cable connection with your equipment, or

re-plug in calbe with your reader. Then turn power on

again.

Q: If scanner has a good read beep but nothing

transferring after read a label.

A: Using the Setting List at �9 to show what current

setting of scanner is, or reset to Default, (or select

right Interface default if scanner has been changed

into another interface used), then re-program

scanner again.

Q: If scanner needs to read single digit code.

A: Refer to Min. code length of code option and set it to

be "01" for single code readable.

Q: If scanner isn't able to discriminate an unknown

label, but read manual very well.

A: Refer to Code Name Transmission at �17 to set

Enable, read a barcode label, then you will know

what symbology is read. Beside, it maybe need to

verify checksum. Refer to verify checksum of code

option and set Enable.

Q: If scanner transfers character very slow or loses

some characters on screen in keyboard interface

after reading a label.

A: You may set caps lock to be Alt+Keypad at �10 to

transmit scan code. Otherwise, it maybe mis-match

of transmission rate. Therefore, you can adjust an

appropriate Inter-char. Delay to match your

equipment. See �11.

���� Please contact with your dealer if scanner dose not

work properly.

Frequent Question 8

Q: If scanner dosen't need an Enter character

addition after each barcode label transmission.

A: Refer to postamble transmission at �33, then set

Disable.

Q: If scanner want to read a label as function key

for your apprication.

A: Refer to function key simulation at �11 and set

Enable, then scanner can transmit a code as

function key. It is used for keyboard interface only.

Beside, you must make sure that a label is encoded

as function key, and its ASCII code is from 0016 to

1F16. Please refer to ASCII code table at �35.

Q: How to update Firmware

A: Please refer to page�11, scan ”Program”

AND ”ISP” barcode to enter update firmware mode,

and execute ”CMISP1.EXE” software to update the

firmware. For ”CMISP1.EXE” software, please

contact technical support for further details.

Q: How to set Specific Adjustments functions?

A: For example1: Set code 39 Min. code length at �35

to be "01" for signal code readable.

Min. code length (00-48) range form 0 up to 48 digits.

PROGRAM�Min. Code Length�0�1�SET�EXIT

For example2: Set keyboard Inter-char. Delay at

�11 to be "10" for match your equipment.

Inter-char. Delay (00-99*1ms) range from 0 to 99 ms.

PROGRAM�Inter-char. Delay�1�0�SET�EXIT

For example3: Set Code ID of UPC-A at �19 to be

"A" for ASCII code.

PROGRAM�Code ID�4�1�SET�EXIT

9 Interface

*/$%PRG* PROGRAM

*/$%C00*

Keyboard

*/$%C01* RS-232C

*/$%C02* Wand Emulation (Option)

*/$%C03* OCIA (Option)

*/$%DEF*

Default

*/$%ISP* ISP(Firmware Update)

*/$%VER* Version Date

*/$%LST* Setting List (Option)

*/$%ESC* Abort

���� All of factory default settings are indicated by '�'.

Keyboard Wedge 10

EXIT */$%EXT*

Keyboard Type *DFA* *DFB*

� IBM AT,PS/2 DFA

DFB IBM XT *DFC*

*DFD* Macintosh ADB. DFC

DFD IBM PS/2 25,30 *DFE* *DFF*

NEC 9801 DFE

DFF IBM PS/2 55 *DFG* *DFH*

IBM 5550 DFG

DFH KT-106 *DFI* *DFJ*

IBM 5576 DFI

DFJ Spare0 *DFK* *DFL*

Spare1 DFK

DFL Spare2

Keyboard Speed *CZA* *CZB*

Low CZA

CZB Medium *CZC*

*CZD* � High CZC

CZD Turbo

Caps Lock *DDA* *DDB*

� Uppercase DDA

DDB Lowercase *DDD*

Alt+Keypad DDD

11 Keyboard Wedge

*/$%PRG* PROGRAM

Numeric Key Position *DAA* *DAB*

� Alphabetic-key DAA

DAB Keypad

Function Key Simulation *DBA* *DBB*

� Disable DBA

DBB Enable

Keyboard Layout *DGA* *DGB*

� USA (US) DGA

DGB Belgium (BE) *DGC*

*DGD* Danish(DK) DGC

DGD France (FR) *DGE* *DGF*

Germany(GR) DGE

DGF Italian (IT) *DGG* *DGH*

Portuguese (PO) DGG

DGH Spanish (SP) *DGI* *DGJ*

Swedish (SV) DGI

DGJ Switzerland (SF) *DGK* *DGL*

UK (UK) DGK

DGL Spare

Specific Adjustments *BAL* *BAM*

Inter-char. Delay (00-99*1ms) BAL

BAM Transmit Delay (00-99*10ms)

RS-232C 12

EXIT */$%EXT*

Handshaking Protocol *DLA* *DLB*

� None DLA

DLB RTS/CTS *DLC*

*DLD* CTS/RTS DLC

DLD Scanner Ready *DLE*

*DLF* Data Ready DLE

DLF X-on/X-off *DLG*

*DLH* STX/ETX DLG

DLH CTS Trigger

Baud Rate *DHG* *DHH*

115200 DHG

DHH 57600 *DHA*

*DHB* 38400 DHA

DHB 19200 *DHC*

*DHD* �9600 DHC

DHD 4800 *DHE*

*DHF* 2400 DHE

DHF 1200

13 RS-232C

*/$%PRG* PROGRAM

Data Parity *DKA* *DKC*

� None DKA

DKC Even *DKD*

*DKE* Odd DKD

DKE Space *DKF*

MarkDKF

Data Length *DJA* *DJB*

7 Bits DJA

DJB 8 Bits �

Stop Length *DIA*

*DIB* � One Bit DIA

DIB Two Bits

Specific Adjustments *BAL* *BAM*

Inter-char. Delay (00-99*1ms) BAL

BAM Transmit Delay (00-99*10ms) *BAN*

Response Delay (00-99*100ms) BAN

Wand Emulation 14

EXIT */$%EXT*

Active Level *DMA* *DMB*

� Bar High DMA

DMB Space High

Normal Level *DNA*

*DNB* � Low DNA

DNB High

Output Speed *DOA* *DOB*

Low DOA

DOB Medium � *DOC*

*DOD* High DOC

DOD Turbo

Narrow/Wide Ratio *DQA* *DQB*

� 1:2 DQA

DQB 1:2.5 *DQC* *DQD*

1:3 DQC

DQD 1:3.5

Code-39 Simulation *DRA* *DRB*

� Disable DRA

DRB Enable

Specific Adjustments *BAL* *BAM*

Margin Delay (00-99*10ms) BAL

BAM Transmit Delay (00-99*10ms)

���� Wand is not available for U.V. light model scanner.

15 OCIA

*/$%PRG* PROGRAM

Protocol Type *DSA* *DSB*

NCR DSA

DSB DTS � *DSC*

*DSD* ASCII DSC

DSD NCR+ASCII *DSE*

DTS+ASCII DSE

Data Parity *DTA* *DTB*

Even DTA

DTB Odd � *DTC* *DTD*

Space DTC

DTD Mark

Specific Adjustments *BAM* Transmit Delay (00-99*10ms) BAM

System Control 16

EXIT */$%EXT*

Power-on Music *CBA* *CBB*

Disable CBA

CBB Enable �

Power-on Auto Trigger *CCA* *CCB*

� Disable CCA

CCB Enable

Good-read LED *CDA* *CDB*

Disable CDA

CDB Enable �

Good-read Beep *CEA* *CEB*

Disable CEA

CEB Enable �

Double Confirm *CSA* *CSB*

� Disable CSA

CSB Enable

Field Control *CRA* *CRB*

� Disable CRA

CRB Enable

Inter-char. Gap *CGA* *CGB*

� Disable CGA

CGB Enable

Case Conversion *CTA* *CTC*

� Disable CTA

CTC Uppercase *CTD*

Lowercase CTD

17 System Control

*/$%PRG* PROGRAM

Scanning Mode *CAB* *CAC*

� Good-read Off CAB

CAC Momentary *CAD*

*CAE* Alternate CAD

CAE Timeout Off *CAF*

*CAG* Timeout Flash CAF

CAG Continue *CAA*

*CAI* Test Only CAA

CAI Spare

Code ID Transmission *IBA* *IBB*

� Disable IBA

IBB Enable

Code ID Position *ICA* *ICB*

� Before Code data ICA

ICB After Code Data

Length Transmission *IKA* *IKB*

� Disable IKA

IKB Enable

Code Name Transmission *IJA* *IJB*

� Disable IJA

IJB Enable

System Control 18

EXIT */$%EXT*

Money Testing *IOA* *IOB*

� None IOA

IOB Right Bottom *IOC*

Left Bottom IOC

Specific Adjustments *BAC* *BAE*

Beep Loudness (01-10) BAC

BAE Beep Duration(01-99*10ms) *BAF*

*BAG* Stand-by Time (01-99*1s) BAF

BAG Active Time (10-99*10ms) *BAH*

*BAI* Sleep Time (10-99*10ms) BAH

BAI Good-read Delay (10-99*10ms) *BAK*

*BAJ* Add-on Waiting Time (01-99*10ms) BAK

BAJ Double Confirm Times (01-99)

���� Money testing is only for UV light model scanner.

19 UPC-A

*/$%PRG* PROGRAM

Code Read *DVA* *DVB*

Disable DVA

DVB Enable �

Add-on Read *DWA* *DWB*

� Disable DWA

DWB Add-on 2 Only *DWC*

*DWD* Add-on 5 Only DWC

DWD Add-on 2+5

Truncate Leading Zero *DZA* *DZB*

� Disable DZA

DZB Enable

Check Digit Transmission *EAA* *EAB*

� Disable EAA

EAB Enable �

Specific Adjustments *BAO* *BAP*

Truncate Leading (00-15) BAO

BAP Truncate Ending (00-15) *AAA*

Code ID (ASCII) AAA

UPC-E 20

EXIT */$%EXT*

Code Read *ECA* *ECB*

Disable ECA

ECB Enable �

Add-on Read *EDA* *EDB*

� Disable EDA

EDB Add-on 2 Only *EDC*

*EDD* Add-on 5 Only EDC

EDD Add-on 2+ 5

Truncate Leading Zero *EHA* *EHB*

� Disable EHA

EHB Enable

Expansion *EFA* *EFB*

� Disable EFA

EFB Enable

Check Digit Transmission *EIA* *EIB*

Disable EIA

EIB Enable �

Specific Adjustments *BAQ* *BAR*

Truncate Leading (00-15) BAQ

BAR Truncate Ending (00-15) *AAB*

*AAC* Code ID0 (ASCII) AAB

AAC Code ID1 (ASCII)

21 EAN-13

*/$%PRG* PROGRAM

Code Read *EKA* *EKB*

Disable EKA

EKB Enable �

Add-on Read *ELA* *ELB*

� Disable ELA

ELB Add-on 2 Only *ELC*

*ELD* Add-on 5 Only ELC

ELD Add-on 2+5

Truncate Leading Zero *EPA* *EPB*

� Disable EPA

EPB Enable

ISBN/ISSN Conversion *ENA* *ENB*

� Disable ENA

ENB Enable

Check Digit Transmission *EQA* *EQB*

Disable EQA

EQB Enable �

Specific Adjustments *BAS* *BAT*

Truncate Leading (00-15) BAS

BAT Truncate Ending (00-15) *AAD*

Code ID0 (ASCII) AAD

EAN-8 22

EXIT */$%EXT*

Code Read *ESA* *ESB*

Disable ESA

ESB Enable �

Add-on Read *ETA* *ETB*

� Disable ETA

ETB Add-on 2 Only *ETC*

*ETD* Add-on 5 Only ETC

ETD Add-on 2+5

Truncate Leading Zero *EXA* *EXB*

� Disable EXA

EXB Enable

Expansion *EVA* *EVB*

� Disable EVA

EVB Enable

Check Digit Transmission *EYA* *EYB*

Disable EYA

EYB Enable �

Specific Adjustments *BAU* *BAV*

Truncate Leading (00-15) BAU

BAV Truncate Ending (00-15) *AAE*

*AAF* Code ID0 (ASCII) AAE

AAF Code ID1 (ASCII)

23 Code-39

*/$%PRG* PROGRAM

Code Read *FAA* *FAB*

Disable FAA

FAB Enable �

Format *FBA* *FBB*

� Standard FBA

FBB Full ASCII

Code-32 Translation *FCA* *FCC*

� Disable FCA

FCC Without Leading 'A' *FCD*

With Leading 'A' FCD

Start/End Transmission *FFA* *FFB*

� Disable FFA

FFB Enable

Checksum Verification *FGA* *FGB*

� Disable FGA

FGB Enable

Checksum Transmission *FHA* *FHB*

� Disable FHA

FHB Enable

Specific Adjustments *BAY* *BAZ*

Truncate Leading (00-15) BAY

BAZ Truncate Ending (00-15) *BAW*

*BAX* Min. Code Length (00-48) BAW

BAX Max. Code Length (00-48) *AAG*

Code ID (ASCII) AAG

Interleaved 2 of 5 24

EXIT */$%EXT*

Code Read *FKA* *FKB*

� Disable FKA

FKB Enable

Format *FLA* *FLB*

� Standard FLA

FLB Odd S-code

Checksum Verification *FNA* *FNB*

� Disable FNA

FNB Enable

Checksum Transmission *FOA* *FOB*

� Disable FOA

FOB Enable

Specific Adjustments *BBC* *BBD*

Truncate Leading (00-15) BBC

BBD Truncate Ending (00-15) *BBA*

*BBB* Min. Code Length (00-48) BBA

BBB Max. Code Length (00-48) *AAH*

Code ID (ASCII) AAH

25 Industrial 2 of 5

*/$%PRG* PROGRAM

Code Read *FQA* *FQB*

� Disable FQA

FQB Enable

Checksum Verification *FSA* *FSB*

� Disable FSA

FSB Enable

Checksum Transmission *FTA* *FTB*

� Disable FTA

FTB Enable

Specific Adjustments *BBG* *BBH*

Truncate Leading (00-15) BBG

BBH Truncate Ending (00-15) *BBE*

*BBF* Min. Code Length (00-48) BBE

BBF Max. Code Length (00-48) *AAI*

Code ID (ASCII) AAI

Matrix 2 of 5 26

EXIT */$%EXT*

Code Read *FVA* *FVB*

� Disable FVA

FVB Enable

Checksum Verification *FXA* *FXB*

� Disable FXA

FXB Enable

Checksum Transmission *FYA* *FYB*

� Disable FYA

FYB Enable

Specific Adjustments *BBK* *BBL*

Truncate Leading (00-15) BBK

BBL Truncate Ending (00-15) *BBI*

*BBJ* Min. Code Length (00-48) BBI

BBJ Max. Code Length (00-48) *AAJ*

Code ID (ASCII) AAJ

27 Codabar/NW7

*/$%PRG* PROGRAM

Code Read *GFA* *GFB*

Disable GFA

GFB Enable �

Start/End Symbol Type *GGA* *GGB*

� ABCD/ABCD GGA

GGB abcd/abcd *GGC*

*GGD* ABCD/TN*E GGC

GGD abcd/tn*e

Same Start/End Pair *GHA* *GHB*

� Disable GHA

GHB Enable

Start/End Transmission *GIA* *GIB*

� Disable GIA

GIB Enable

Checksum Verification *GJA* *GJB*

� Disable GJA

GJB Enable

Checksum Transmission *GKA* *GKB*

� Disable GKA

GKB Enable

Codabar/NW7 28

EXIT */$%EXT*

Specific Adjustments *BBS* *BBT*

Truncate Leading (00-15) BBS

BBT Truncate Ending (00-15) *BBQ*

*BBR* Min. Code Length (00-48) BBQ

BBR Max. Code Length (00-48) *AAL* Code ID (ASCII) AAL

29 Code-128

*/$%PRG* PROGRAM

Code Read *GMA* *GMB*

Disable GMA

GMB Enable �

Format *GNA* *GNB*

� Standard GNA

GNB UCC/EAN-128

Checksum Verification *GQA* *GQB*

Disable GQA

GQB Enable �

Checksum Transmission *GRA* *GRB*

� Disable GRA

GRB Enable

Specific Adjustments *BBW* *BBX*

Truncate Leading (00-15) BBW

BBX Truncate Ending (00-15) *BBU*

*BBV* Min. Code Length (00-48) BBU

BBV Max. Code Length (00-48) *AAM*

*ABK* Code ID (ASCII) AAM

ABK Concatenation Code (ASCII)

Code-93 30

EXIT */$%EXT*

Code Read *GTA* *GTB*

� Disable GTA

GTB Enable

Checksum Verification *GWA* *GWC*

Disable GWA

GWC One Digit *GWD*

� Two DigitsGWD

Checksum Transmission *GXA* *GXB*

� Disable GXA

GXB Enable

Specific Adjustments *BCA* *BCB*

Truncate Leading (00-15) BCA

BCB Truncate Ending (00-15) *BBY*

*BBZ* Min. Code Length (00-48) BBY

BBZ Max. Code Length (00-48) *AAN* Code ID (ASCII) AAN

31 Code-11

*/$%PRG* PROGRAM

Code Read *GZA* *GZB*

� Disable GZA

GZB Enable

Checksum Verification *HBA* *HBC*

Disable HBA

HBC One Digit *HBD*

� Two Digits HBD

Checksum Transmission *HCA* *HCB*

� Disable HCA

HCB Enable

Specific Adjustments *BCE* *BCF*

Truncate Leading (00-15) BCE

BCF Truncate Ending (00-15) *BCC*

*BCD* Min. Code Length (00-48) BCC

BCD Max. Code Length (00-48) *AAO*

Code ID (ASCII) AAO

MSI/Plessey 32

EXIT */$%EXT*

Code Read *HEA* *HEB*

� Disable HEA

HEB Enable

Checksum Verification *HGA* *HGB*

Disable HGA

HGB Mod 10 � *HGC* *HGD*

Mod 10/10 HGC

HGD Mod 11/10

Checksum Transmission *HHA* *HHB*

� Disable HHA

HHB Enable

Specific Adjustments *BCI* *BCJ*

Truncate Leading (00-15) BCI

BCJ Truncate Ending (00-15) *BCG*

*BCH* Min. Code Length (00-48) BCG

BCH Max. Code Length (00-48) *AAP*

Code ID (ASCII) AAP

33 UK/Plessey

*/$%PRG* PROGRAM

Code Read *HQA* *HQB*

� Disable HQA

HQB Enable

Checksum Verification *HSA* *HSB*

Disable HSA

HSB Enable �

Checksum Transmission *HTA* *HTB*

� Disable HTA

HTB Enable

Specific Adjustments *BCQ* *BCR*

Truncate Leading (00-15) BCQ

BCR Truncate Ending (00-15) *BCO*

*BCP* Min. Code Length (00-48) BCO

BCP Max. Code Length (00-48) *AAR*

Code ID (ASCII) AAR

Preamble/Postamble 34

EXIT */$%EXT*

Preamble Transmission *IEA* *IEB*

� Disable IEA

IEB Enable

Preamble Data *AAZ* *ABA*

Data0 (ASCII) AAZ

ABA Data1 (ASCII)

Postamble Transmission *IFA* *IFB*

Disable IFA

IFB Enable�

Postamble Data *ABB* *ABC*

Data0 (ASCII) ABB

ABC Data1 (ASCII)

Prefix Transmission *IGA* *IGB*

� Disable IGA

IGB Enable *IMA*

Clear All Data IMA

Prefix Data *ABF* 15 Bytes Data (ASCII) ABF

Suffix Transmission *IHA* *IHB*

� Disable IHA

IHB Enable *INA*

Clear All Data INA

Suffix Data *ABG* 15 Bytes Data (ASCII) ABG

35 ASCII Code Table

*/$%PRG* PROGRAM

L H 0 1 0 1

0 Null NUL DLE

1 Up F1 SOH DC1

2 Down F2 STX DC2

3 Left F3 ETX DC3

4 Right F4 EOT DC4

5 PgUp F5 ENQ NAK

6 PgDn F6 ACK SYN

7 F7 BEL ETB

8 Bs F8 BS CAN

9 Tab F9 HT EM

A F10 LF SUM

B Esc VT ESC

C F11 FF FS

D Enter F12 CR GS

E Insert Ctrl+ SO RS

F Delete Alt+ SI US

**** For keyboard wedge only.

L H 2 3 4 5 6 7

0 SP 0 @ P ` p

1 ! 1 A Q a q

2 “ 2 B R b r

3 # 3 C S c s

4 $ 4 D T d t

5 % 5 E U e u

6 & 6 F V f v

7 ‘ 7 G W g w

8 ( 8 H X h x

9 ) 9 I Y i y

A * : J Z j z

B + ; K [ k {

C , < L \ l |

D - = M ] m }

E . > N ^ n ~

F / ? O _ o DEL

Hexdecimal/Decimal Table 36

EXIT */$%EXT*

*%00* *%01*

0 %00

%01 1 *%02*

*%03* 2 %02

%03 3 *%04*

*%05* 4 %04

%05 5 *%06*

*%07* 6 %06

%07 7 *%08*

*%09* 8 %08

%09 9 *%0A*

*%0B* A %0A

%0B B *%0C*

*%0D* C %0C

%0D D *%0E*

*%0F* E %0E

%0F F

*%OK* Set %0K