barricade udl specs · 2018-07-06 · barricade® udl is laid out horizontally (parallel) to the...

4
2 5 Y E A R L I M I T E D W A RR A N T Y B A R R I C A D E ® U D L P L U S 25 2 0 Y E A R L I M I T E D W A RR A N T Y B A R R I C A D E ® U D L 20 3 0 Y E A R L I M I T E D W A RR A N T Y B A R R I C A D E ® U D L S E L E C T 30 Roofing Underlayments BARRICADE BUILDING PRODUCTS

Upload: others

Post on 25-May-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Barricade UDL Specs · 2018-07-06 · Barricade® UDL is laid out horizontally (parallel) to the eave with the printed side up, and with 4 inch (101mm) horizontal laps and 6 inch

• 25

YEAR LIMITED WARRANT

Y •

BARRICADE® UDL PLUS

25 •

20 Y

EAR LIMITED WARRANT

Y •

BARRICA DE® UDL

20

• 30

YEAR LIMITED WARRAN

TY

BARRICAD E® UDL SELEC

T30

Roofing UnderlaymentsBARRICADE BUILDING PRODUCTS

Page 2: Barricade UDL Specs · 2018-07-06 · Barricade® UDL is laid out horizontally (parallel) to the eave with the printed side up, and with 4 inch (101mm) horizontal laps and 6 inch
Page 3: Barricade UDL Specs · 2018-07-06 · Barricade® UDL is laid out horizontally (parallel) to the eave with the printed side up, and with 4 inch (101mm) horizontal laps and 6 inch

Barricade® UDL Features/Benefits and Specifications

FEATURES/BENEFITSSuitable for all roof coveringsCool gray surface – 30° cooler than black UDL’s48" widthUV protection – 60 days5 and 10 square rolls14% more coverage per lap – 48" width compared to 42" synthetics33% more coverage per lap – 48" width compared to 36" feltSuperior non-skid coatingSuperior tear resistanceEase of installation – lays flat, doesn’t wrinkle and is water resistantFaster install time vs felt and other narrower synthetics saving time/moneySuperior strength compared to feltMeets and ExceedsASTM D226 I & II, ASTM 4869 II & IV

TEST DATA

Test Procedure Typical Value

Water Transmission ASTM D4869 PASS

Water Vapor Transmission Rate

ASTM E96 1 US Perms

Temperature Range DOSITM-064 -70° to 212°F

Dimensional Stability ASTM F1087 PASS

SPECIFICATIONSRoll Width: 48"Roll Length: 125' and 250'5 square rolls weigh 9.5 lbs per rolland 1,216 lbs per pallet10 square rolls weigh 19 lbs per rolland 1,216 lbs per pallet

Barricade® Plus Features/Benefits and Specifications

FEATURES/BENEFITSSuitable for all roof coveringsCool gray surface – 30° cooler than black UDL’s48" widthExceptional UV protection – 180 days5 and 10 square rolls14% more coverage per lap – 48" width compared to 42" synthetics33% more coverage per lap – 48" width compared to 36" feltSuperior non-skid coating on both sidesSuperior tear resistanceEase of installation – lays flat, doesn’t wrinkle and is water resistantFaster install time vs felt and other narrower synthetics saving time/moneySuperior strength compared to feltMeets and ExceedsASTM D226 I & II, ASTM 4869 II & IV

TEST DATA

Test Procedure Typical Value

Water Transmission ASTM D4869 PASS

Water Vapor Transmission Rate

ASTM E96 1 US Perms

Temperature Range DOSITM-064 -70° to 212°F

Dimensional Stability ASTM F1087 PASS

SPECIFICATIONSRoll Width: 48"Roll Length: 125' and 250'5 square rolls weigh 13 lbs per rolland 1,274 lbs per pallet10 square rolls weigh 26 lbs per rolland 1,274 lbs per pallet

Barricade® Select Features/Benefits and Specifications

FEATURES/BENEFITSSuitable for all roof coveringsCool gray surface – 30° cooler than black UDL’s48" widthExceptional UV protection – 180 days5 and 10 square rolls14% more coverage per lap – 48" width compared to 42" synthetics33% more coverage per lap – 48" width compared to 36" feltSuperior non-skid coating on both sidesSuperior tear resistanceEase of installation – lays flat, doesn’t wrinkle and is water resistantFaster install time vs felt and other narrower synthetics saving time/moneySuperior strength compared to feltMeets and ExceedsASTM D226 I & II, ASTM 4869 II & IV

TEST DATA

Test Procedure Typical Value

Water Transmission ASTM D4869 PASS

Water Vapor Transmission Rate

ASTM E96 1 US Perms

Temperature Range DOSITM-064 -70° to 212°F

Dimensional Stability ASTM F1087 PASS

SPECIFICATIONSRoll Width: 48"Roll Length: 125' and 250'5 square rolls weigh 15.5 lbs per rolland 1,116 lbs per pallet10 square rolls weigh 31 lbs per rolland 1,116 lbs per pallet

877-832-0333barricadebp.com • [email protected]

Page 4: Barricade UDL Specs · 2018-07-06 · Barricade® UDL is laid out horizontally (parallel) to the eave with the printed side up, and with 4 inch (101mm) horizontal laps and 6 inch

877-832-0333barricadebp.com • [email protected] Verdon Road • Doswell, VA 23047

Manufacturing quality building envelope materials for over 25 years.

Barricade® UDL Installation InstructionsROLL SIZE

48" x 250' (1,000 ft²) and 48" x 125' (500 ft²)

COVERAGE

Approximately 916 sq. ft. per roll or less depending upon overlap and roof design.

PREPARATION

The deck surface must be dry and free of dust, dirt, loose nails, debris and other protrusions. Damaged sheathing must be replaced. Ensure that the space beneath the roof sheathing is properly ventilated before installing to avoid condensation problems.

INSTALLATION

Barricade® UDL is laid out horizontally (parallel) to the eave with the printed side up, and with 4 inch (101mm) horizontal laps and 6 inch (152mm) vertical laps. Follow the codes for the low slopes as defined as 2:12 to 4:12 and steep slopes greater than 4:12 applications. UDL is designed to withstand 60 days of exposure prior to being covered with the final roofing material. Barricade® recommends covering UDL with the final roofing material as soon as possible.

FASTENERS

Barricade® recommends attaching UDL to the structural roof deck material using plastic cap ring shanked roofing nails having a minimum 1" (25mm) diameter plastic cap. Anchoring to be installed at a minimum as per surface markings, spaced 6" (15cm) on center in the vertical and horizontal laps, and at 12" (30cm) on center along the center of the roll in the field as marked. If the application of UDL and the final roofing material occur on the same day, then the option to use every other printed anchoring placement is acceptable. For same day coverage, corrosion resistant 3⁄8" head and 1" leg roofing nails are acceptable as well as 1" plastic cap staples. High slope roofs, > 7/12 pitch must use plastic cap nails. All anchoring devices must be flush, 90 degrees to the roof deck, tight with the underlayment surface and the structural roof deck.

CAUTION – GOOD SAFETY PRACTICES

As with any roofing product, always follow safe roofing codes & practices (OSHA) and always use and wear fall protection devices when working on roofs. Examples: toe boards, rope harness, rubber or synthetic soft sole footwear. Use caution when walking or standing on Barricade® UDL as wet and/or dusty conditions may reduce traction. Failure to use proper safety gear and footwear can result in serious injury.