barua marcelo ism instrumentation · title: microsoft powerpoint - barua marcelo ism...

20
Precision Monitoring Inc. ISM Micropile Test Instrumentation

Upload: others

Post on 15-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

ISM Micropile Test

Instrumentation

Page 2: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

ISM Micropile – Our Scope1. Design two engineered fills – with 10 kPa and

20 kPa shear. (Thanks - Wing)

2. Set-up instrumentation to monitor – load, displacement and bending in real-time (Thanks to Ivan and Gabriel, Measurand).

3. Set-Up video and data feed between the two locations (Thanks to Lewko).

Page 3: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.1. Engineered Fills• Literature search and discussions plastic slurry wall and cement-

bentonite specialists.

• Feedback and previous experience gave us a starting point plus warnings about predictability and repeatability.

• Starting point - grouts consisting of 6.5% bentonite slurries mixed with percentages by weight of cement, ranging from 2% to 12%.

Page 4: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

• Shear testing -ASTM standard test method for laboratory miniature vane shear test (ASTM D 4648-05).

• Initial results lowerthan expected.

1. Engineered Fills

Page 5: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

• Additional mixes of 14%, 16%, 18% and 20% cementmixes were batched to extend the data set to greater shear strengths.

• Two distinct curves from each data set?

• A smaller mixer and half batches for the first set of tests and larger mixer and full batches for the second set of tests.

1. Engineered Fills

Page 6: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

Grout Shear Strength

0

10

20

30

40

50

60

70

80

90

0% 2% 4% 6% 8% 10% 12% 14% 16% 18% 20% 2

Cement %

Shea

r Str

engt

h (k

Pa)

7 Day Tests 2%-12%

15 Day Tests 2%-12%

7 Day Averages

15 Day Averages

7 Day Tests 14%-20%

Extrapolated from first set of tests 14 day shear strengths.

Extrapolated from second set of tests 7 day shear strengths.

Page 7: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

2. Real-Time Instrumentation:

• Cap displacement in relation to the applied load

• Displacement vs. load in plotted on screen in real-time

• Bending or buckling of the bar.

• Movement of the reaction piles.

• Archive data

Page 8: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

The Set up

Micropile

Reaction Beam

Jack

Tiedown

1) Monitor the displacement of

the cap

2) Measure the pressure applied by

the jack

3) Observe any bending or buckling

of the micropile

4) As a safety precaution, see

the pullout motion on reaction piles

Page 9: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

LVDT’s• Linear Variable differential Transformer

-- Instruments similar in function to electronic dial gauges.– Accurate and precise as dial gauges and infinity resolution.– More suitable for rugged site conditions, and unlike dial gauges,

interface easily with computers.

=

Page 10: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

Pressure Transducer

– This sensor transforms pressure into an analogue electrical signal.

– Easily connected to a datalogger or a computer.

Page 11: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

Measurand ShapeAccelArray• Measurand ShapeAccelArray

– A series of sensor (accelerometers) linked together (MEMS Technology).

– It produces a 3D representation of the borehole, bar, etc.

– Better resolution that a series of in-place inclinometers.

Page 12: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

Page 13: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

Page 14: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

The method used:• To see the vertical movement of the cap, four

LVDT’s were placed on the cap.• The pressure transducer was attached to the

hydraulic jack.• Each tie-down also had a LVDT for any possible

pull-out during the test.• A ShapeAccelArray was inserted inside the

micropile to see any bending during the compression.

Page 15: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

• All LVDT’s and the pressure transducer were connected to a datalogger that collected readings every second.

• A graph showing the Displacement vs. Load was produced in real time.

• Using Measurand SAArecorder software, the bending of the bar was monitored as the bar was loaded.

Page 16: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

Page 17: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

Page 18: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

ShapeAccelArray Screen shot

Hewlett Packard Displacement vs. Load

graph

Page 19: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

?

Lessons Learned• SAA – installation details

1. annulus webbing or no webbing

2. supported on bottom / hung from top

2 to 4 mm

Page 20: BARUA Marcelo ISM Instrumentation · Title: Microsoft PowerPoint - BARUA Marcelo ISM Instrumentation.ppt Author: Mary Ellen Bruce Created Date: 1/8/2008 3:56:50 PM

Precision Monitoring Inc.

Conclusions• Engineered fill shear values lower than design targets:

15 kPa and 2 to 3 kPa

• The LVDT’s, pressure transducers, datalogger and related software worked as expected.

• ShapeAccelArray and Measurand’s software worked well. We gained experience regarding installation details and using the instrument as a real-time monitoring instrument.

• All the instrumentation performed as it was designed to: providing accurate measurements and allowing further analysis after the test.

• Video and Data Feed – See it later today.