Lesson HC 1/07/1.1
Aim of Learning:
To enable installer to set up a link form a blank or poorly setup link from a given loadfile
Reason for learning:
The Ericsson HC Link is a complicated OSPF router and requires extensiveconfiguration of the routing and the monitor provisioning systems to function asrequired within a network.
Subject of this lesson:
This lesson details how to upload a configuration file to the Ericsson HC radio. The
upload will erase all the settings currently in the MMU/ TRU and will cause a trafficoutage. The upload of the text configuration file is the first method and preferredmethod of setting up the Ericsson HC radio.
There are site specific files available for each end of the link. The end NEAREST therouter (NMS hub) is always considered to be the NEAR END, the other end is the FAREND, ALWAYS
File types:
There are two types of file you will have access to.
Site specific. This will contain all the settings required for the site with the exception ofthe RF setup (Power, Capacity, Protection and Frequency). The NMS IP addresses will
be present as will the router specific configurations. This is the preferred upload. Thefile is obtainable form the NMS Design Website (http://203.14.20.80/3gnms - user &password = 3gnms)
Base configuration file. This is a file specific only to the NE or FE. It does not containsite specific information or RF setup information. This file is to be used in conjunctionwith the NMS instruction (as per above). The Installer must configure all site specificand router specific options.
Upon completion the files should be downloaded from the newly installed link andadded to the library system for fault recovery by emailing the files to the sitecoordinator
http://203.14.20.80/3gnmshttp://203.14.20.80/3gnmshttp://203.14.20.80/3gnms -
7/29/2019 Base Cfg
2/8
Connect to Ericsson HC links R7A
Connect via the purpose written conduit. GML
Ericsson HC Serial Cable. If you use the default
Windows Connect via Serial Cable the results will
be unpredictable.
-
7/29/2019 Base Cfg
3/8
Using Internet Explorer
(If you must use Microsoft Explorer )
The correct version of MS Java
-
7/29/2019 Base Cfg
4/8
Using Mozilla Browsers (Firefox etc)
Using Mozilla simply works. There is no need to modifythe Java client. All errors are well handled and all the interface
views are visible. Missing interface views are a sign in MS IE that
there is a problem with the installation of Java.
-
7/29/2019 Base Cfg
5/8
UPLOADING!
The uploaded configuration files must be in
C:\Program Files\MINI-LINK Ptp HighCapacity\output
The same location for uploading software packages
-
7/29/2019 Base Cfg
6/8
To Upload a configuration
Ericsson Minilink PTP Manager must be installed.
The required software packages need to be copiedto the output directory.
Connect to the HC Radio using the Serial portdialup PPP session.
Connect to the default address 192.168.0.1 usingyour web browser.
A prompt will request credentials.
User = administrator
Password = administrator
Connect as administrator service ONLY
-
7/29/2019 Base Cfg
7/8
Connecting ready to upload
software package
-
7/29/2019 Base Cfg
8/8
Enter file name for upload be
sure to check that you have
selected Download