basic pump operations based on the ifsta driver/operator pumper 2 nd edition
TRANSCRIPT
![Page 1: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/1.jpg)
BASIC PUMP OPERATIONS
BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2ND EDITION
![Page 2: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/2.jpg)
Chapter 1What is water?
![Page 3: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/3.jpg)
OBJECTIVES Upon completion of Chapter 1 the
student shall be able to:• List characteristics of water and why it is
used as an extinguishing agent.• Explain the ways in which water smothers
fire.• List advantages and disadvantages of water
as an extinguishing agent.• Match definitions to terms associated with
pressure.
![Page 4: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/4.jpg)
Objectives Continued• List causes of friction loss in fire hose.• List the principles of friction loss.• List ways to reduce friction loss• Describe what a water hammer is and how
to prevent a water hammer from occurring.
![Page 5: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/5.jpg)
CHARARACTISITICS OF WATER Water is a compound of hydrogen and
oxygen formed when two hydrogen atoms (H2) combine with one oxygen atom (O).
Between 32ºF and 212ºF (0ºC and 100ºC), water exists in a liquid state.
It is a stable liquid, which is normally readily available at fire scenes.
![Page 6: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/6.jpg)
CHARARACTISITICS OF WATER Below 32º F (0ºC) (the freezing point of
water), water converts to a solid state called ice.
Above 212ºF (100ºC) (the boiling point of water), water converts into a gas called water vapor or steam; it cannot be seen.
Water is capable of absorbing large amounts of heat.
![Page 7: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/7.jpg)
Characteristics of Water
![Page 8: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/8.jpg)
CHARARACTISITICS OF WATER Water is considered to be incompressible,
and its weight varies at different temperatures.
Water is heaviest close to its freezing point.
Water is lightest close to its boiling point.
For fire protection purposes, ordinary fresh water is generally considered to weigh 8.33 lb/gal
![Page 9: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/9.jpg)
Ways in WhichWater Extinguishes Fire
Cooling• By absorbing heat from the fire
Smothering• Water can be used to smother fires in
combustible liquids whose specific gravity is higher than 1.
• Smothering also occurs to some extent when water converts to steam in a confined space.
![Page 10: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/10.jpg)
Advantages of Water asan Extinguishing Agent
Water has a greater heat-absorbing capacity than other common extinguishing agents.
A relatively large amount of heat is required to change water to steam. This means that more heat is absorbed from the fire.
![Page 11: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/11.jpg)
Advantages of Water asan Extinguishing Agent
The greater the surface area of water exposed, the more rapidly heat is absorbed. The exposed surface are of water can be expanded by using fog streams or deflecting solid streams off objects.
Water converted into steam occupies 1,700 times its original volume.
Water is plentiful, relatively inexpensive, and readily available in most jurisdictions.
![Page 12: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/12.jpg)
Disadvantages of Water asan Extinguishing Agent
Water has a high surface tension and does not readily soak into dense materials. However, when wetting agents are mixed with water, the water’s surface tension is reduced and its penetrating ability is increased.
Water may be reactive with certain fuels such as combustible metals.
![Page 13: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/13.jpg)
Disadvantages of Water asan Extinguishing Agent
Water has low levels of opacity and reflectivity that allow radiant heat to easily pass through it.
Water readily conducts electricity, which can be hazardous to firefighters working around energized electrical equipment.
![Page 14: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/14.jpg)
Disadvantages of Water asan Extinguishing Agent
Water freezes at 32ºF (0ºC), which is a problem in jurisdictions that frequently experience freezing conditions. Water freezing poses a hazard to firefighters by coating equipment, roofs, ladders, and other surfaces. In addition, ice forming in and on equipment may cause it to malfunction.
![Page 15: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/15.jpg)
Determining Force
![Page 16: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/16.jpg)
Determining Force A 1-square-inch column of water 1
foot high exerts a pressure at its base of 0.434 psi.
The height required for a 1-square-inch column of water to produce 1 psi at its base equals 1 foot divided by 0.434 psi/ft.
Therefore, 2.304 feet of water column exerts a pressure of 1 psi at its base.
![Page 17: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/17.jpg)
Terms Associated with Pressure
Atmospheric pressure — Pressure exerted by the atmosphere at sea level (14.7 psi)
psig — Pounds per square inch gauge; actual atmospheric pressure = gauge reading
Vacuum — Any pressure less than atmospheric pressure
![Page 18: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/18.jpg)
Terms Associated with Pressure
Negative pressure — Gauge readings of less than 0 psi
Head — The height of a water supply above the discharge orifice
Head pressure — The result of dividing the number of feet that the water supply is above the discharge orifice by 2.304
Static — At rest or without motion
![Page 19: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/19.jpg)
Terms Associated with Pressure
Static pressure — Stored potential energy available to force water through pipe, fittings, fire hose, and adapters
Residual — A remainder or that which is left
Residual pressure — That part of the total available pressure not used to overcome friction loss or gravity while forcing water through pipe, fittings, fire hose, and adapters
![Page 20: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/20.jpg)
![Page 21: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/21.jpg)
Terms Associated with Pressure
Elevation — The center line of the pump or the bottom of a static water supply source above or below ground level
Pressure loss — When a nozzle is above the pump
Pressure gain — When the nozzle is below the pump
Elevation pressure — Another term for both pressure loss and pressure gain
![Page 22: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/22.jpg)
Terms Associated with Pressure
Friction loss — That part of the total pressure lost while forcing water through pipe, fittings, fire hose, and adapters
![Page 23: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/23.jpg)
Causes of Friction Loss in Fire Hose
Movement of water molecules against each other
Linings in fire hose Couplings Sharp bends Change in hose size or orifice by
adapters Improper gasket size
![Page 24: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/24.jpg)
Principles of Friction Loss First Principle — If all other conditions
are the same, friction loss varies directly with the length of the hose or pipe.
![Page 25: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/25.jpg)
Principles of Friction Loss Second
Principle — When hoses are the same size, friction loss varies approximately with the square of the increase in the velocity of the flow.
![Page 26: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/26.jpg)
Principles of Friction Loss Third Principle – For the same
discharge, friction loss varies inversely to the diameter of the hose. The larger the hose the less friction loss.
Fourth Principle – For a given flow velocity, friction loss is approximately the same, regardless of the pressure on the water. So no matter the size of the hose, friction loss will be the same if the water is moving at the same velocity.
![Page 27: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/27.jpg)
Ways to Reduce Friction Loss
Minimize sharp bends or kinks in the hose by using proper hose handling techniques.
Reduce the length of the hose or increase its diameter.
![Page 28: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/28.jpg)
Water Hammer Suddenly stopping water moving
through a hose or pipe results in an energy surge being transmitted in the opposite direction, often at many times the original pressure. This surge is referred to as water hammer.
Water hammer can damage the pump, appliances, hose, or the municipal water system itself.
![Page 29: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/29.jpg)
Water Hammer
![Page 30: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/30.jpg)
Water Hammer Always open and close nozzle
controls, hydrants, valves, and hose clamps slowly to prevent water hammer.
Apparatus inlets and remote outlets should be equipped with pressure relief devices to prevent damage to equipment.
High-volume systems should be protected with dump valves.
![Page 31: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/31.jpg)
Summary All pumping apparatus
driver/operators should • Understand the properties of water as a
fire extinguishing agent• Know the factors that influence its
delivery during a pumping operation• Be thoroughly familiar with the operation
of the apparatus to which they are assigned
![Page 32: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/32.jpg)
Discussion Questions How does water have the ability to
extinguish fire? What are the advantages of water as
an extinguishing agent? What are the disadvantages of water
as an extinguishing agent? What are some of the causes of
friction loss in fire hose?
![Page 33: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/33.jpg)
Discussion Questions Name ways to reduce friction loss. What is a water hammer?
![Page 34: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/34.jpg)
Student Questions
![Page 35: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/35.jpg)
Chapter 2Fire Hose Nozzles and Flow Rates
![Page 36: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/36.jpg)
Objectives Define fire stream. List factors that influence a fire
stream. Explain why driver/operator must be
knowledgeable about fire streams. List nozzle operating pressures for:
• Smooth bore handline• Fog handline• Smooth bore master stream• Fog master stream
![Page 37: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/37.jpg)
Fire Stream A fire stream is a stream of water or
other extinguishing agent after it leaves a nozzle until it reaches the desired point. To be effective, must deliver a sufficient quantity of water.
![Page 38: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/38.jpg)
Fire Steams Fire streams are influenced by:
• Velocity• Gravity• Wind• Friction with the air• Operating pressures• Nozzle design • Nozzle adjustment• Condition of the nozzle orifice
![Page 39: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/39.jpg)
Fire Steams
The type of fire stream applied to a fire depends on the nozzle being used.
Each nozzle has its own optimum flow rate and discharge pressure, which affects the calculations performed by the driver/operator.
Driver/Operators must understand the capabilities of each nozzle to provide the appropriate pressure and volume of water.
![Page 40: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/40.jpg)
Solid Stream Nozzles Produce a
stream as compact as possible with little shower or spray
Reach areas that other streams might not
![Page 41: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/41.jpg)
Solid Steam Nozzles May be used on handlines, portable
or apparatus-mounted master streams, or elevated master streams
Are designed so that the shape of the water in the nozzle is gradually reduced until it reaches a point a short distance from the outlet; at this point, the nozzle becomes a cylindrical bore whose length is from one to one and one-half times its diameter
![Page 42: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/42.jpg)
Solid Stream Nozzles Have a smooth-finish waterway that
contributes to both the shape and reach of the stream
Note: Alteration or damage to the nozzle can significantly alter stream shape and performance.
![Page 43: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/43.jpg)
Solid Stream Nozzles Nozzle pressure and the size of the
discharge opening determine the flow and stream reach.
Should be operated at 50 psi on handlines
Should be operated at 80 psi on master stream devices
![Page 44: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/44.jpg)
Flow Rates for Smooth Bore Nozzles
GPM SOLID BORE NOZZLE50 psi
(handline)80 psi
(master stream)7/8” = 150 gpm 1 3/8” = 400 gpm
1” = 200 gpm 1½” = 600 gpm
1 1/8” = 250 gpm 1¾” = 800 gpm
1¼” = 300 gpm 2” = 1000 gpm
![Page 45: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/45.jpg)
Fog Nozzles A nozzle that breaks the water that
flows through it into tiny droplets of water. The theory is that small droplets of water create more surface area than a solid stream created by a smooth bore nozzle. The water absorbs the heat, turns into steam, and displaces the oxygen, smothering the fire.
![Page 46: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/46.jpg)
Reach of a fog Stream Is directly
dependent on• Width of the
stream• Size of water
droplets• Wind• Amount of
water flowing
![Page 47: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/47.jpg)
Constant Flow Nozzles Are designed to flow a specific
amount of water at a specific nozzle discharge pressure on all stream patterns
Discharge the same volume of water regardless of the pattern setting
Are intended to be operated at a nozzle pressure of 100 psi
![Page 48: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/48.jpg)
Constant Flow Nozzle
![Page 49: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/49.jpg)
Constant Flow Nozzles Fixed gallonage nozzle has one hole
size Single Flow Combination (Fog) Nozzle One correct nozzle pressure
• To achieve rated flow• To achieve optimum performance
Pump pressure must be changed each time nozzle or tip is changed
![Page 50: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/50.jpg)
Manually Adjustable Nozzle Have a number of constant flow
settings, enabling a flow rate that best suits the existing conditions
Supply the selected flow at the rated nozzle discharge pressure; actual flow will differ if proper pressure cannot be supplied
Are designed to supply the gallonage marked on each setting at a nozzle pressure of 100 psi
![Page 51: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/51.jpg)
Manually Adjustable Nozzles
Selectable gallonage nozzle has a few different hole sizes
Manually changed One correct nozzle pressure
• To achieve rated flow• To achieve optimum performance
Pump pressure must be changed each time setting is changed
![Page 52: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/52.jpg)
Manually Adjustable NozzleSelectable Gallonage Ring
![Page 53: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/53.jpg)
Automatic Nozzles Are the most common variable flow
nozzles in use Are also referred to as constant
pressure nozzles or multipurpose nozzles
Are variable flow nozzles with pattern-change capabilities and the ability to maintain the same nozzle pressure
![Page 54: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/54.jpg)
Automatic Nozzle Maintain approximately same nozzle
pressure and pattern if gallonage supplied to nozzle changes
Can have a stream that appears adequate, but may not be supplying sufficient water for extinguishment or protection; the goal of the driver/operator is to provide an acceptable flow of water at the discharge pressure for which the nozzle is designed
![Page 55: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/55.jpg)
Automatic Nozzle Most are designed for a 100 psi
discharge pressure
Serve as a pressure regulator for the pumper as lines are added or shut down, ensuring that available water may be used continuously
![Page 56: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/56.jpg)
Automatic Nozzle
NOTE: Baffle opening.
NOTE: Change in baffle opening as gpm increases.
NOTE: Change in baffle opening as gpm increases.
300 GPM @ 100 PSI
200 GPM @ 100 PSI
100 GPM @ 100 PSI
![Page 57: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/57.jpg)
Automatic Nozzles CAUTION! Make sure that adequate
pump discharge pressures are used to supply hoselines equipped with automatic nozzles. Nozzles receiving inadequate pressures may not provide the volume of water needed to sufficiently cool a burning fuel even though the stream appears adequate.
![Page 58: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/58.jpg)
Handline Nozzles Are designed to be placed on attack
lines that can be easily maneuvered by firefighters
May be of the solid, fog, impinging, or broken stream type
Range in size from small booster line nozzles for ¾-inch booster line to large fog or solid stream nozzles for 3-inch hoseline
![Page 59: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/59.jpg)
Handline Nozzles Can flow a maximum of 350 gpm
safely; flows greater than 350 gpm produce nozzle reactions that make the hoselines difficult and dangerous for firefighters to handle
![Page 60: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/60.jpg)
Master Stream Nozzles Include any fire stream that is too
large to be controlled without mechanical aid
Are powerful and generate a considerable amount of nozzle reaction force; it is extremely important that firefighters take proper safety precautions
![Page 61: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/61.jpg)
Master Stream Nozzles May be either solid or fog streams;
both utilize a nozzle of sufficient size to deliver the higher flows
Are usually operated at 80 psi (smoothbore) and 100 psi (fog)
Flow 350 gpm or greater
![Page 62: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/62.jpg)
Master Stream Nozzles Friction loss varies from device to
device – each department must determine the friction loss in the devices it has available, either by flow test or manufacturer’s documentation
Add 25 psi for master stream device.
![Page 63: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/63.jpg)
Summary Pumping apparatus driver/operators
must be familiar with the different types of nozzles carried on their apparatus.
Each type of nozzle has its own optimum flow rate and discharge pressure.
![Page 64: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/64.jpg)
Summary The particular type of nozzle being
used affects the hydraulic calculations that driver/operators must perform.
Even though driver/operators are usually not responsible for selecting an appropriate nozzle to perform a particular evolution, they must understand the capabilities of each nozzle in order to properly support it.
![Page 65: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/65.jpg)
Discussion Questions What is a fire stream?
What factors influence a fire stream?
When are master stream nozzles used?
What is the operating pressures for each type of nozzle discussed?
![Page 66: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/66.jpg)
Chapter 3Theoretical and Field Hydraulic
Calculations.
![Page 67: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/67.jpg)
RESA
Lesson Objective To calculate pressure loss in a variety
of hose lays and fireground situations. Candidates will also be able to use the figures derived from pressure loss calculations to determine the pump discharge pressure required to adequately supply fire streams
![Page 68: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/68.jpg)
RESA
Objectives List variables that must be taken into
consideration when calculating total pressure loss.
Calculate friction loss. Calculate elevation pressure. Calculate total pressure loss in single
hoseline layouts.
![Page 69: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/69.jpg)
Objectives
Calculate pump discharge pressure. Select facts about flowmeters. Interpret a pump chart. Use the hand method for 2 ½” and 1
¾” hoselines.
![Page 70: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/70.jpg)
Driver Operator Responsibilities
To supply fire suppression crews with the water flow and pressure needed to achieve fire control and/or extinguishment.
Rarely uses theoretical calculations on fireground.
Theoretical calculations give D/O a better understanding of the basis for fireground methods of calculation.
![Page 71: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/71.jpg)
Driver Operator Responsibilities
Theoretical calculations allow the D/O to predetermine accurate pump discharge pressures for preconnected hoselines and common hose lays.
Serves as a tool for pre-incident planning at properties that require hose deployment that is out of the ordinary for the fire department.
![Page 72: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/72.jpg)
RESA
![Page 73: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/73.jpg)
![Page 74: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/74.jpg)
VARIABLES TO TAKE INTO ACCOUNT WHEN CALCULATING TOTAL PRESSURE LOSS (TPL)
Volume of water flowing per minute Length and diameter of the hoseline Any major appliances attached to
hoseline Pressure loss or gain created by
elevation differences
![Page 75: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/75.jpg)
Determining Friction Loss
Actual Tests - Best method is to perform test with pressure gauges to measure pressure loss in hoses and appliances
Calculations - Give a general sense of the friction loss, but will differ from the actual test
![Page 76: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/76.jpg)
Determining Friction Loss FL = CQ2L
• FL = Friction loss in psi• C = Friction loss constant for particular
hose• Q = Flow rate in hundreds of gpm
(flow/100)• L = Hose length in hundreds of feet
(length/100) This is the formula used by IFSTA &
NFPA
![Page 77: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/77.jpg)
![Page 78: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/78.jpg)
Steps to Determine Friction Loss
Obtain from table the friction loss coefficient for the hose being used
Determine the number of hundreds of gallons of water per minute flowing (Q) through the hose Q = gpm/100
Determine the number of hundred of feet of hose (L) with L = feet/100
Plug number obtained into equation
![Page 79: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/79.jpg)
Example 1
If 300 gpm is flowing from a nozzle, what is the total pressure loss due to friction for 400 feet of 2½” hose?
C = 2Q = gpm/100 = 300/100 = 3L = feet/100 = 400/100 = 4FL = CQ2L = (2) (3)2 (4) = (2) (9) (4) FL = 72 psi
![Page 80: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/80.jpg)
Example 2What is the total pressure loss due to
friction in 600 feet of 4” hose flowing 750 gpm?
C = 0.2Q = gpm/100 = 750/100 = 7.5L = feet/100 = 600/100 = 6FL=CQ2L = (0.2) (7.5)2 (6) = (0.2)
(56.25) (6)FL = 67.5 psi total friction loss
![Page 81: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/81.jpg)
Example 3What is the total pressure loss due to
friction in 250 feet of 1¾” hose when 150 gpm flowing?
C = 15.5Q = gpm/100 = 150/100 = 1.5L = hose length/100 = 250/100 = 2.5FL=CQ2L=(15.5)(1.5)2(2.5)=(15.5)
(2.25)(2.5)FL = 87.2 psi total friction loss
![Page 82: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/82.jpg)
Student Activity 3-1
![Page 83: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/83.jpg)
Appliance Pressure Loss 0 psi pressure loss for flows less than
350 gpm 10 psi pressure loss for flows 350 or
greater 25 psi friction loss in all master
stream appliances 25 psi friction loss for standpipe
systems
![Page 84: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/84.jpg)
Elevation Pressure Elevation pressure, which is created by
elevation differences between the nozzle and the pump must be considered when determining total pump pressure
Water exerts 0.434 psi per foot of elevation Higher elevation demands an increase in
pressure to compensate Lower elevation demands a decrease in
pressure to compensate
![Page 85: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/85.jpg)
![Page 86: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/86.jpg)
Elevation Pressure
EP = 0.5 HEP = Elevation pressure in psi0.5 = A constantH = Height in feet
For Multistory BuildingsEP = 5 psi x (number of stories - 1)
![Page 87: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/87.jpg)
Example 4
Calculate the total pressure loss due to elevation pressure for a hoseline operating at the top of a 100 foot hill.
EP = 0.5 HEP = (0.5) (100)EP = 50 psi
![Page 88: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/88.jpg)
Example 5
A hoseline operating on a ninth-floor structure fire is connected to the building’s standpipe system. What is the total pressure loss due to elevation at the base of the standpipe system?
EP = 5 psi (number of stories - 1)EP = 5 psi x (9-1) = (5) (8)EP = 40 psi
![Page 89: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/89.jpg)
Student Activity 3-2
![Page 90: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/90.jpg)
Calculate Total Pressure Loss in a Single Hoseline Layout
Most commonly used layout Attack lines and supply lines Simplest friction loss calculations
![Page 91: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/91.jpg)
Calculate Total Pressure Loss in Single Hoseline Layouts
Total Pressure Loss (TPL)• TPL = FL ± EP• EP = Elevation pressure in psi• FL = Friction Loss
EP = 0.5 H FL = CQ2L
![Page 92: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/92.jpg)
Example 6
A pumper is supplying a hoseline with 250 gpm flowing. The hoseline is 200 feet of 2½” hose. What is the pressure loss due to friction in the hose assembly?
![Page 93: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/93.jpg)
Example 6
2½” HoseC = 2Q = gpm/100 = 250/100 = 2.50L = Feet/100 = 200/100 = 2FL = CQ2L = (2)(2.5)2(2) = (2) (6.25)
(2)FL = 25 psi
![Page 94: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/94.jpg)
Example 7
A pumper is supply 100 feet of 1¾” hose flowing 150 gpm to the second story of a house. What is the pressure loss due to friction and elevation in the hose assembly?
![Page 95: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/95.jpg)
Example 7
FL = C Q2 LFL = (15.5) (1.50)2 (1)FL = 35 psi EP = 5 psi (number of stories - 1)EP = 5 psi (2-1) = 5 psiTPL = 35 psi + 5 psi = 40 psi
![Page 96: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/96.jpg)
Student Activity 3-3
![Page 97: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/97.jpg)
Pump Discharge Pressure PDP=NP + TPL PDP= Pump discharge pressure in psi NP= Nozzle pressure in psi TPL=Total pressure loss in psi
• Appliance, friction and elevation gain or loss
![Page 98: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/98.jpg)
Example 8 A pumper is supplying 200 feet of
2½” hose flowing 200 gpm through a fog nozzle. What is the pump discharge pressure required to supply the hoseline?
![Page 99: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/99.jpg)
Example 8 PDP = NP + TPL NP = 100 (Fog nozzle) TPL = FL + SA ± EP FL = CQ2L FL = (2) (2)2(2) FL = 16 PDP = 100 + 16= 116 psi
![Page 100: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/100.jpg)
Example 9 A pumper is supplying a 1¾” hoseline
200 feet long equipped with a 200 gpm smooth bore nozzle. What is the pump discharge pressure required to supply this hoseline?
![Page 101: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/101.jpg)
Example 9 PDP = NP + TPL NP = 50 (Smooth bore handline) TPL = FL + SA ± EP FL = CQ2L FL = (15.5) (2)2(2) FL = 124 PDP = 50 + 124=174
![Page 102: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/102.jpg)
Student Activity 3-4
![Page 103: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/103.jpg)
Fireground Hydraulic Calculations
![Page 104: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/104.jpg)
Methods for Determining Pressure Loss and Required Pump Discharge
Pressure
Flowmeters Hydraulic calculators Pump charts Hand method Condensed “Q” formula GPM flowing method
![Page 105: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/105.jpg)
Flowmeters
Provide water flow in gpm; displayed number requires no further calculation
Are particularly advantageous when supplying hoselines or master stream devices equipped with automatic nozzles
![Page 106: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/106.jpg)
Flowmeters Can make it possible for
driver/operators to pump the correct volume of water to nozzles without knowing the length of hoseline, the amount of friction loss, or whether the nozzles are above or below the pump
Are allowed to be used instead of pressure gauges on all discharges 1½ to 3 inches in diameter
![Page 107: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/107.jpg)
Flowmeters Can be used on discharges that are
3½ inches or larger, but must also have an accompanying pressure gauge
Must provide a readout in increments no larger than 10 gpm
![Page 108: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/108.jpg)
Flowmeters Should be accurate to a tolerance of
+/- 3 percent, when properly calibrated and in good working condition
Have a discharge readout display mounted within 6 inches of the valve control for each discharge equipped
![Page 109: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/109.jpg)
Central Flowmeter Device Provides
• Flow through any particular discharge at that time
• Total amount of water being flowed through the pump at that time
• Total amount of water that has been flowed through the pump for the duration of that incident
• Amount of foam being flowed
![Page 110: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/110.jpg)
Diagnosing Waterflow Problems
If the flow does not increase when the driver/operator increases pressure, several problems are likely – kinks, a closed valve, etc.
If water volume at the nozzle has suddenly diminished but there is no reduction in the flowmeter reading, it can be assumed that a hose has burst.
![Page 111: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/111.jpg)
Hydraulic Calculators
Enable the driver/operator to determine the pump discharge pressure required to supply a hose layout without having to perform tedious mental hydraulic calculations
![Page 112: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/112.jpg)
Hydraulic Calculators Manual or mechanical — Operate
by moving a slide or dial in which the water flow, size of hose, and length of the hose lay are indicated
![Page 113: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/113.jpg)
Hydraulic Calculators Electronic
• Allow the driver/operator to input the known information: water flow, size of hose, length of hose lay, elevation changes
• Computes required pump discharge pressure using preprogrammed formulas
• Portable or mounted near the pump panel• Inexpensive programmable calculators can
be preprogrammed and carried on apparatus.
![Page 114: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/114.jpg)
Akron Brass Fire Calculator
The Akron FireCalc is the only calculator on the market to offer solutions for engine pressure, friction loss, application flow rate, flow rate, reaction force etc. A training tool every firefighter can use when determining fire ground hydraulics.
![Page 115: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/115.jpg)
Pump Charts Are used by some fire departments to
reduce the need for calculations on the emergency scene
Contain the required pump discharge pressures for various hose lays and assemblies used within that jurisdiction
![Page 116: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/116.jpg)
Pump Charts May be placed on laminated sheets
carried on the apparatus or on plates that are affixed to the pump panel
May be developed by fire departments or supplied by fire hose or nozzle manufacturers
![Page 117: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/117.jpg)
Pump Chart Columns Nozzle column — Includes nozzles
and devices used by the department developing the chart; includes applications such as sprinkler system support or relay pumping operations
GPM column — Indicates the flow being provided to that nozzle or layout
![Page 118: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/118.jpg)
Pump Chart Columns
NP column — Indicates the nozzle pressure being produced
100, 200, etc. columns — Indicate the number of feet of hose being used to supply a given nozzle or layout
![Page 119: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/119.jpg)
How to Use Pump Charts
1. Locate a nozzle column and the nozzle or layout being used.
2. Follow that line across to the vertical column headed by the number of feet of hose in that layout.
3. The figure in the block where the two columns intersect is the required pump discharge pressure.
![Page 120: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/120.jpg)
Developing a Pump Chart Identify all nozzles, devices, and
layouts used by the department and enter them in the nozzle column.
Enter gpm flowing and the nozzle pressure desired for each item in the appropriate columns.
Calculate the required pump discharge pressures for each of the listed layouts.
![Page 121: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/121.jpg)
Calculating Pressures for Pump Charts
Be certain to include friction loss in master stream appliances flowing in excess of 350 gpm.
For wyed hoselines, the length of layout numbers indicate the number of feet of hose between the pumper and the wye.
![Page 122: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/122.jpg)
Calculating Pressures for Pump Charts
When a master stream nozzle may be supplied by a different number or size of hoselines, indicate these on the chart.
Round pump discharge pressure to the nearest 5 psi.
Do not list pump discharge pressures that exceed the test pressure used for the size of hose concerned or the pump test pressure.
![Page 123: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/123.jpg)
Calculating Pressures for Pump Charts
When calculating pump discharge pressures for relay operations, provide established departmental residual pressures at the intake of the pumper being supplied. This residual pressure may be indicated on the chart as a nozzle pressure.
![Page 124: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/124.jpg)
Sample Pump Chart
![Page 125: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/125.jpg)
Hand Method for 2½-inch Hose
1. Starting with the thumb of the left hand, each finger is numbered at the base in terms of hundreds of gpm.
2. Returning to the thumb, and again moving from left to right, the tip of each finger is given a successive even number, beginning with two.
![Page 126: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/126.jpg)
Hand Method for 2½-inch Hose
3. Because nozzle capacities vary in gpm, the nearest half-hundred can be used with slight variations. The numbers 3, 5, 7, and 9 can be used for flows of 150, 250, 350, and 450 gpm, respectively. These half-hundred figures can be assigned to the spaces between the fingers.
![Page 127: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/127.jpg)
Hand Method for 2½-inch Hose
4. The friction loss for 100 feet of 2½-inch hose at a desired flow is determined by selecting the finger to which the desired flow has been assigned, and multiplying the number at the tip of the finger by the first digit at the base of the finger.
![Page 128: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/128.jpg)
Hand Method for 2½-inch Hose
5. The answers provided by this method give a reasonable estimate of the friction loss that can be expected in that hoseline. If more accurate figures are required, one of the other methods previously discussed in this curriculum needs to be employed.
![Page 129: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/129.jpg)
Hand Method for 2½-inch Hose
![Page 130: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/130.jpg)
Sample Problems Using the hand method calculate the
friction loss for 100 feet of 2½” hose flowing 300 GPM.• 3 x 6 = 18 psi
Using the hand method calculate the friction loss for 100 feet of 2½” hose flowing 250 GPM.• 2.5 x 5 = 12.5 psi
Using the hand method calculate the friction loss for 300 feet of 2½” hose flowing 200 GPM.• 2 x 4 = 8 psi per 100 feet x 300 feet = 21
psi
![Page 131: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/131.jpg)
Hand Method for 1¾-inch Hose
Calculate the friction loss in 100 feet of 1¾-inch hose by going to the finger that corresponds to the flow you are using and multiplying the number at the tip of the finger by the number at the base of the same finger.
![Page 132: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/132.jpg)
Sample Problems Using the hand method calculate the
friction loss for 100 feet of 1 ¾” hose flowing 150 GPM.• 3 x 12 = 36 psi
Using the hand method calculate the friction loss for 100 feet of 1 ¾” hose flowing 100 GPM.• 1 x 12 = 12 psi
Using the hand method calculate the friction loss for 200 feet of 1 ¾” hose flowing 200 GPM.• 5 x 12 = 60 psi per 100 feet x 200 feet =
120 psi
![Page 133: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/133.jpg)
9–133
Summary Fireground situations are often loud
and chaotic scenes that make performing complex mental calculations difficult for driver/operators.
Many departments train driver/operators to use flowmeters, hydraulic calculators, pump charts, and simplified methods of determining pressure loss and required pump discharge pressure during fire incidents.
![Page 134: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/134.jpg)
Discussion Questions
1. What is the IFSTA and NFPA formula for determining friction loss in fire hose?
2. What factors must be considered when determining the pump discharge pressure?
3. How many columns are there on a pump chart? Name each column.
![Page 135: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/135.jpg)
Discussion Questions
4. Describe the hand method for determining friction loss.
![Page 136: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/136.jpg)
Student Questions
![Page 137: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/137.jpg)
Chapter 4Fire Pump Design and Operation
![Page 138: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/138.jpg)
Objectives Complete statements about the
operation of positive displacement fire pumps.
Answer questions about centrifugal pumps.
Complete statements about the operation of centrifugal pumps.
Answer questions about changeover. Identify characteristics of various
automatic pressure control devices.
![Page 139: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/139.jpg)
Objectives Continued Match pump primers to their
descriptions and operating techniques.
Match pump panel controls and instruments to their descriptions.
State the primary function of an auxiliary cooler.
![Page 140: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/140.jpg)
Positive Displacement Pumps
Have been largely replaced by the centrifugal pump for use as the main fire pump on modern fire apparatus
Are still a necessary part of the overall pumping system on modern fire apparatus because they pump air
![Page 141: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/141.jpg)
Positive Displacement Pumps
Are used as priming devices to get water into centrifugal pumps during drafting operations
By removing the air trapped in the centrifugal pump, water is forced into the pump casing by atmospheric pressure
Types• Piston• Rotary
![Page 142: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/142.jpg)
Rotary Pumps Are the simplest of all pumps in
design
Were used extensively as the major pump on older fire apparatus
Are now used as small capacity booster-type pumps, low-volume high pressure pumps, and priming pumps
![Page 143: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/143.jpg)
Operation of Rotary Gear Pumps
Two gears rotate in a tightly meshed pattern inside a watertight case. The gears contact each other and are in close proximity to the case.
![Page 144: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/144.jpg)
Operation of Rotary Gear Pumps
With this arrangement, the gears within the case form watertight and airtight pockets as they turn from the intake to the outlet.
As each gear tooth reaches the discharge chamber, the air or water in that pocket is forced out of the pump.
![Page 145: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/145.jpg)
Operation of Rotary Gear Pumps
As the tooth returns to the intake side of the pump, the gears are meshed tightly enough to prevent the water or air that has been discharged from returning to the intake.
![Page 146: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/146.jpg)
Rotary Gear Pump Characteristics
Produce amount water dependent upon the size of the pockets in the gears and the speed of rotation
Are very susceptible to damage from normal wear, sand, and other debris; can be prevented with bronze or soft metal gears
![Page 147: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/147.jpg)
Rotary Vane Pump Characteristics
Are constructed with movable elements that compensate for wear and maintain a tighter fit with close clearances as the pump is used
![Page 148: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/148.jpg)
Rotary Vane Pump Characteristics
Are one of the most common types of pumps used to prime centrifugal pumps
Are more efficient at pumping air than a rotary gear pump because the pump is self-adjusting
![Page 149: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/149.jpg)
Operation of Rotary Vane Pumps
The rotor is mounted off-center inside the housing. The distance between the rotor and the housing is much greater at the intake than it is at the discharge. The vanes are free to move within the slot where they are mounted.
As the rotor turns, the vanes are forced against the housing by centrifugal force.
![Page 150: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/150.jpg)
Operation of Rotary Vane Pumps
When the surface of the vane that is in contact with the casing becomes worn, centrifugal force causes it to extend further, thus automatically maintaining a tight fit.
As the rotor turns, air is trapped between the rotor and the casing in the pockets forced by adjacent vanes.
![Page 151: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/151.jpg)
Operation of Rotary Vane Pumps
As the vanes turn, this pocket becomes smaller, which compresses the air and causes pressure to build up. This pocket becomes even smaller as the vanes progress toward the discharge opening.
![Page 152: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/152.jpg)
Operation of Rotary Vane Pumps
At this point, the pressure reaches its maximum level, forcing the trapped air out of the pump. The air or water is prevented from returning to the intake by the close spacing of the rotor at that point.
![Page 153: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/153.jpg)
Operation of Rotary Vane Pumps
The air being evacuated from the intake side causes a reduced pressure (similar to a vacuum), and water is forced into the pump by atmospheric pressure until the pump fills with water.
At this point, the pump is primed and forces water out of the discharge in the same manner as air was forced out.
![Page 154: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/154.jpg)
Motor
Rotary Vane Pump
![Page 155: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/155.jpg)
Centrifugal Pumps Are utilized by nearly all modern fire
apparatus
Are classified as nonpositive displacement pumps because they do not pump a definite amount of water with each revolution. Rather, they impart velocity to the water and convert it to pressure within the pump itself.
![Page 156: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/156.jpg)
Centrifugal Pumps
Have virtually eliminated the positive displacement pump as a major fire pump in the fire apparatus
![Page 157: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/157.jpg)
Centrifugal Pumps Consists of:
• Impeller — Transmits energy in the form of velocity to the water
• Casing — Collects the water and confines it in order to convert the velocity to pressure
• Volute — Is a water passage that gradually increases in cross-sectional area as it nears the pump discharge outlet
![Page 158: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/158.jpg)
Centrifugal Pumps
![Page 159: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/159.jpg)
![Page 160: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/160.jpg)
Centrifugal Pumps The impeller in a centrifugal pump
rotates very rapidly within the casing, generally from 2,000 to 4,000 rpm.
The volume capacity of the pump is dependent on the size of the eye of the impeller. The greater the eye, the greater the flow capacity.
![Page 161: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/161.jpg)
Centrifugal Pumps Main factors that influence discharge
pressure:• Amount of water being discharged• Speed at which the impeller is turning• Pressure of water when it enters the
pump from a pressurized source (hydrant, relay, etc.)
![Page 162: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/162.jpg)
Operation and Construction of Centrifugal Pumps
The operation of a centrifugal pump is based on the principle that a rapidly revolving disk tends to throw water introduced at its center toward the outer edge of the disk. The faster the disk is turned, the farther the water is thrown, or the more velocity the water has.
![Page 163: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/163.jpg)
Operation and Construction of Centrifugal Pumps
![Page 164: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/164.jpg)
Operation and Construction of Centrifugal Pumps
If the water is contained at the edge of the disk, the water at the center of the container begins to move outward. The velocity created by the spinning disk is converted to pressure by confining the water within the container.
The water is limited by the walls of the container and moves upward in the path of least resistance.
![Page 165: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/165.jpg)
Operation and Construction of Centrifugal Pumps
This shows that pressure has been created on the water. The height to which it raises, or to extend to which it overcomes the force of gravity, depends upon the speed of rotation.
![Page 166: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/166.jpg)
Operation and Construction of Centrifugal Pumps
The centrifugal pump consists of two parts: an impeller and a casing. The impeller transmits energy in the form of velocity to the water. The casing collects the water and confines it in order to convert the velocity to pressure. Then the casing directs the water to the discharge of the pump.
![Page 167: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/167.jpg)
Single-Stage Centrifugal Fire Pumps
Are constructed with a single impeller Are used on front-mount pumps,
PTOs, separate engine-driven and midship transfer pumps
May provide capacities up to 2,000 gpm
May have a double suction impeller to minimize the lateral thrust of large quantities of water entering the eye of the impeller
![Page 168: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/168.jpg)
Single-Stage Centrifugal Fire Pumps
![Page 169: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/169.jpg)
Multi-Stage Centrifugal Fire Pumps
Have an impeller for each stage mounted within a single housing
Have impellers that are usually mounted on a single shaft driven by a single drivetrain
Have identical impellers of the same capacity
Have the capability of connecting the stages in series for maximum pressure or in parallel for maximum volume by use of a transfer valve
![Page 170: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/170.jpg)
Multi-Stage Centrifugal Fire Pumps
Courtesy: Hale Fire Pump Company
![Page 171: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/171.jpg)
Multi-Stage Pumps in theParallel (Volume) Position
Have impellers that take water from a source and deliver it to the discharge
Causes impellers to be capable of delivering its rated pressure while flowing 50 percent of the rated capacity; therefore, the total amount of water the pump can deliver is equal to the sum of each stage
![Page 172: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/172.jpg)
Multi-Stage Pumps in theParallel (Volume) Position
![Page 173: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/173.jpg)
Multi-Stage Pumps in theSeries (Pressure) Position
All water from the manifold is directed into the eye of the first impeller, increasing the pressure and discharging 50 to 70 percent of the volume capacity through the transfer valve and into the eye of the second impeller.
The second impeller increases the pressure and delivers the water at the higher pressure into the pump discharge port.
![Page 174: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/174.jpg)
Multi-Stage Pumps in theSeries (Pressure) Position
Courtesy: Waterous Company
![Page 175: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/175.jpg)
Changeover The process of switching between the
pressure and volume position
SOPs in some departments specify that the transfer valve stay in the pressure position until it is necessary to supply more than one-half the rated volume capacity of the pump.
![Page 176: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/176.jpg)
Changeover
However, most pump manufacturers specify that the pump may remain in the pressure system until it is necessary to flow more than two-thirds of the rated volume capacity. At lower flow rates, operating in the series (pressure) position reduces the load and the required rpm of the engine.
![Page 177: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/177.jpg)
Changeover Consult the owner’s manual for:
• The specific pump being operated to obtain information on its recommended flow rate at which the transfer should occur.
• The maximum pressure at which the transfer valve should be operated. In most cases, the recommended maximum pressure will not exceed 50 psi.
![Page 178: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/178.jpg)
Changeover Because there may be a slight
interruption to fireground operations when changeover occurs, coordinate with attack crews so that lines are not shut down at critical times.
Attempt to anticipate the requirements that will be placed on the pumper as the fire fighting operation progresses and have the pump in the proper position.
![Page 179: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/179.jpg)
Changeover If there is any question as to the
proper operation of the transfer valve, it is better to be in parallel (volume) than in series (pressure). While the parallel (volume) position may make it difficult to attain the desired pressure, it can supply 100 percent of the rated capacity at 150 psi at draft.
![Page 180: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/180.jpg)
Changeover There is a built-in safeguard on many
older pumps that makes it physically impossible to accomplish manual transfer while the pump is operating at high pressures.
Newer pumps utilize a power-operated transfer valve that can be activated by electricity, air pressure, vacuum from the engine intake manifold, or water pressure itself.
![Page 181: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/181.jpg)
Changeover Use special care when operating
power-operated transfer valves. These valves operate at pressures as high as 200 psi.
Be familiar with the manual override device installed on some transfer valves. These overrides allow the transfer to be operated should the power equipment fail.
![Page 182: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/182.jpg)
Changeover The clapper (check) valves are
essential in a multi-stage pump. When the transfer valve is operated, the clapper valve allows water to escape back into the intake, and it churns through the pump instead of building up pressure. If the valves should stick open or closed or get debris caught, the pump will not operate properly in the series (pressure) position. Inspect the valve often to ensure that the pump can be properly flushed.
![Page 183: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/183.jpg)
Changeover
Some manufacturers have used as many as four impellers connected in series to develop pressures up to 1,000 psi for high-pressure fog fire fighting. Pumpers that are designed to supply high pressures must be equipped with fire hose that is rated and tested for these pressures.
![Page 184: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/184.jpg)
Automatic PressureControl Devices
When a pump is supplying multiple attack lines, any sudden flow change in one line can cause a pressure surge on the other.
Some type of automatic pressure regulation is essential to ensure the safety of personnel operating the hoselines.
![Page 185: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/185.jpg)
Automatic PressureControl Devices
NFPA 1901 requires some type of pressure control device to be part of any fire apparatus pumping system.
The device must operate within 3 to 10 seconds after the discharge pressure rises and must not allow the pressure to exceed 30 psi.
![Page 186: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/186.jpg)
Relief Valves
Those that relieve excess pressure on the discharge side of the pump
Those that relieve excess pressure on the intake side of the pump
![Page 187: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/187.jpg)
Discharge Pressure Relief Valves
Are an integral part of all fire pumps that are not equipped with a pressure governor
Are sensitive to pressure change and have the ability to relieve excess pressure within the pump discharge
![Page 188: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/188.jpg)
Discharge Pressure Relief Valves
Have adjustable spring-loaded pilot valve that actuates the relief valve to bypass water from discharge to intake chamber of the pump
Are quick to react to overpressure conditions, but are somewhat slower to reset back to “all-closed” positions
Take a short time for the pump to return to normal operation
![Page 189: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/189.jpg)
Discharge Pressure Relief Valves Types
• Spring-controlled pilot valve — A spring-loaded pilot valve actuates a relief valve to bypass water from pump discharge to pump intake
• Alternative spring-controlled pilot valve — A spring-loaded pilot valve compresses, allowing water to flow through an opening in its housing, through the bleed line, and into the pump intake, which forces the churn valve to open and allows water to flow from the discharge into the intake
![Page 190: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/190.jpg)
Intake Pressure Relief Valves
Are intended to reduce the possibility of damage to the pump and discharge hoselines caused by water hammer
Should be set to open when the intake pressure rises more than 10 psi above the desired operating pressure
![Page 191: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/191.jpg)
Intake Pressure Relief Valves
Types• Supplied by the pump manufacturer and
is an integral part of the pump intake manifold
• Add-on device that is screwed onto the pump intake connection
![Page 192: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/192.jpg)
Pump Panel Controls Required by NFPA 1901
Master pump intake pressure indicating device
Master pump discharge pressure indicating device
Weatherproof tachometer Pumping engine coolant temperature
indicator Pumping engine oil pressure indicator Pump overheat indicator
![Page 193: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/193.jpg)
Pump Panel Controls Required by NFPA 1901
Voltmeter Pump pressure controls (discharge
valves) Pumping engine throttle Primer control Water tank to pump valve Tank fill valve Water tank level indicator
![Page 194: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/194.jpg)
Master Intake Gauge (Vacuum or Compound Gauge)
Is used to determine the water pressure entering the pump
Must be connected to the intake side of the pump
Must be capable of measuring either positive pressure or a vacuum
![Page 195: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/195.jpg)
Master Intake Gauge (Vacuum or Compound Gauge)
Is usually calibrated from 0 to 600 psi positive pressure from 0 to 30 inches of mercury (vacuum) on the negative side
Provides an indication of the residual pressure when the pump is operating from a hydrant or is receiving water through a supply line from another pump
![Page 196: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/196.jpg)
Master Pump Discharge Pressure Gauge
Registers the pressure as it leaves the pump, but before it reaches the gauges for each individual discharge line
Must be calibrated to measure 600 psi unless the pumper is equipped to supply high-pressure fog streams, then the gauge may be calibrated up to 1,000 psi
Must have external connections to allow installation of calibrated gauges when service tests are performed
![Page 197: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/197.jpg)
Tachometer Records the engine speed in rpm
Is useful as a means of trouble analysis when difficulty with the pump is encountered – a gradual increase in the amount of rpm required to pump the rated capacity indicates wear in the pump and a need for repairs
![Page 198: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/198.jpg)
Pumping Engine Coolant Temperature Indicator
Shows the temperature of the coolant in the engine that powers the fire pump
May indicate temperature of the main vehicle engine or the pump engine
![Page 199: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/199.jpg)
Pumping Engine Oil Pressure Indicator
Shows that an adequate supply of oil is being delivered to the critical areas of the engine that is powering the fire pump
Indicates pending problems by showing any significant deviation from the normal oil pressure
![Page 200: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/200.jpg)
Pump Overheat Indicator
Warns the driver/operator when the pump overheats
![Page 201: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/201.jpg)
Voltmeter
Provides a relative indication of battery condition and alternator output
![Page 202: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/202.jpg)
Pump Pressure Indicators (Discharge Gauges)
Indicate actual pressure applied to hoselines
Must be connected to the outlet side of the discharge valve so that the pressure being reported is the pressure actually being applied to the hoselines after the valve
Allow pressure in each discharge to be adjusted down from the overall pump discharge pressure if necessary
![Page 203: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/203.jpg)
Pump Pressure Indicators (Discharge Gauges)
May be included on master stream devices or the lines that supply them; effective master streams are impossible to maintain without the proper pressure
May be substituted by flowmeter readouts, but master intake and pressure gauges are still required
![Page 204: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/204.jpg)
Pumping Engine Throttle Is used to increase or decrease the
speed of the engine that is powering the fire pump
Most common is a knob that is turned one way or another until the desired rpm/pressure is achieved
Is also available with automatic throttle controls
![Page 205: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/205.jpg)
Primer Control
Is used to operate the priming device when the pump is going to be used to draft from a static water supply
![Page 206: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/206.jpg)
Water Tank Level Indicator Indicates how much water is
remaining in the onboard water tank Allows the driver/operator to
anticipate how much longer attack hoselines may be supplied before an external water supply source is needed
Uses a series of lights on the pump operator’s panel that indicate the amount of water in the tank by one-quarter levels
![Page 207: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/207.jpg)
Auxiliary Coolers
Function• To control the temperature of coolant in
the apparatus engine during pumping operations
![Page 208: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/208.jpg)
![Page 209: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/209.jpg)
Summary
While some water systems supply sufficient pressure to operate nozzles and other fire fighting equipment without the pressure being increased, most fire situations require the fire department to increase the available water pressure.
![Page 210: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/210.jpg)
Summary In most cases, added pressure is
provided by a fire pump built into a piece of fire apparatus.
To do their jobs properly, driver/operators must know the operating theory as well as the operational capabilities and limitations of the pumping apparatus within their departments.
![Page 211: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/211.jpg)
Discussion Questions
1. Explain how a rotary pump operates.
2. Name the three parts of a centrifugal pump.
3. Explain how a centrifugal pump operates.
![Page 212: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/212.jpg)
Discussion Questions4. What is changeover?
5. What is the primary function of an auxiliary cooler?
![Page 213: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/213.jpg)
RESA
Student Questions
![Page 214: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/214.jpg)
Chapter 5Fire Pump Operation
![Page 215: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/215.jpg)
Objectives Answer questions about making the
pump operational. Engage and disengage a midship
pump. Complete statements about
operating from the water tank. Operate from the apparatus water
tank. Make the transition from the
apparatus water tank to an external water supply.
![Page 216: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/216.jpg)
Objectives Answer questions about operating
from a pressurized water supply source.
Operate from a pressurized water source.
List the preliminary checks that should be made after making hydrant connections but before opening the hydrant.
Answer questions about putting the pump in service.
![Page 217: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/217.jpg)
Objectives List methods for preventing pump
overheating. List the steps for shutting down the
hydrant operation. Answer questions about operating
from a static water supply source. List indications that a pump is
cavitating. Answer questions about priming the
pump and beginning operation.
![Page 218: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/218.jpg)
Objectives List common causes of inability to
prime the pump. List the categories of problems that
can occur while operating from draft. Operate from a static water source.
![Page 219: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/219.jpg)
![Page 220: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/220.jpg)
Making the Fire Pump Operational
Is also referred to as “putting the pump into gear”
Begins after the apparatus has been properly positioned and the parking brake has been set
![Page 221: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/221.jpg)
Making the Fire Pump Operational
After properly positioning the apparatus and setting the parking brake, on the majority of apparatus, the remainder of the procedure for making the fire pump operational takes place before the driver/operator exits the cab.
![Page 222: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/222.jpg)
Making the Fire Pump Operational
Once the driver/operator exits the cab, in all cases except when the apparatus is used for pump-and-roll operations, the next step should be to chock the apparatus wheels.
![Page 223: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/223.jpg)
Making the Fire Pump Operational It is
recommended that the apparatus wheels be chocked every time the apparatus is stopped with the engine running and the driver/operator exits the cab.
![Page 224: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/224.jpg)
Operating from the Water Tank
Most driver/operators operate solely from the onboard water tank at the vast majority of incidents.
In some circumstances, the fire attack begins with the water tank and may then make the transition to an external supply source.
![Page 225: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/225.jpg)
Operating from the Water Tank
The pump operator must be able to make the transition from the apparatus tank to an incoming water supply smoothly, with no disruption of the fireground operation.
![Page 226: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/226.jpg)
Operating from a Pressurized Water Supply Source
Two basic pressurized water supply sources used to supply a fire pump• Hydrant• A supply hose from another fire pump
![Page 227: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/227.jpg)
Negative Pump Pressure (Vacuum)
Water enters the pump under pressure.
As the discharge pressure or volume from the fire pump increases, the incoming pressure from the supply source may drop due to friction loss in the water system.
If the discharge pressure is increased too much, the intake pressure from the supply source may be reduced below 0 psi.
![Page 228: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/228.jpg)
Dangers of Operating at Negative Pressure from a Fire Hydrant
Increases the possibility of damage to the fire pump due to cavitation
Can cause damage to the pump and water system due to water hammer if the flow is stopped suddenly
May damage water heaters or other domestic appliances on a municipal water supply system
![Page 229: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/229.jpg)
Dangers of Operating at Negative Pressure from Another Pumper
Can cause supply hose to collapse, resulting in interruption of water supply
Can damage the pump through cavitation
![Page 230: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/230.jpg)
After Making Hydrant Connections but Before Opening the Hydrant
Check that:• The tank–to-pump valve must be closed
if the intake is not equipped with a shutoff valve
• A dry barrel hydrant must be opened all the way
![Page 231: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/231.jpg)
After Making Hydrant Connections but Before Opening the Hydrant
After the pump is full of water and the pressure in the system has stabilized with no water flowing, a reading of the pressure on the master intake gauge indicates the static pressure in the water supply system.
![Page 232: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/232.jpg)
After Making Hydrant Connections but Before Opening the Hydrant
It may be desirable for the pump operator to record or remember the static pressure before the operation begins.
Some departments use a grease pencil to mark the static pressure on the intake gauge.
![Page 233: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/233.jpg)
Putting the Pump in Service
Do not engage the pump drive system before leaving the cab if there will be an extended period of time where water is introduced into the pump.
On a two-stage pump, set the transfer valve to the proper position before increasing the throttle to build discharge pressure.
Open discharge valves slowly.
![Page 234: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/234.jpg)
Preventing Pump Overheating
Pull some of the booster line off the reel and securely tie off the nozzle to a solid object. Open the valve that supplies the booster reel, and discharge water in a direction that will not harm people or damage property.
![Page 235: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/235.jpg)
Preventing Pump Overheating
Open a discharge drain valve.• Designed to discharge water in a manner that
will not harm people or damage property• May have threaded outlets that allow hose to
be connected and routed to a safe discharge point
• If so, discharge water away from the apparatus so that it does not become stuck in the mud (or frozen in ice) that could be created by discharging water directly beneath it
![Page 236: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/236.jpg)
Preventing Pump Overheating
Partially open the tank fill valve or pump-to-tank line.
Use a bypass or circulator valve if the apparatus is so equipped.
![Page 237: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/237.jpg)
Shutting Down the Hydrant Operation
1. Gradually slow the engine rpm to idle to reduce the discharge pressure.2. Take the pressure control device out of service if in use.3. Slowly and smoothly close the discharge valves.4. Place the drive transmission in neutral, and disengage the pump control device.
![Page 238: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/238.jpg)
Operating from a Static Water Supply Source
In most cases, pumpers will be pumping water from a static water supply that will be located at a lower level than the fire pump.
Because one drop of water will not stick to another, it is not possible to pull water into the pump from a lower level.
![Page 239: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/239.jpg)
Operating from a Static Water Supply Source
To pump from a lower level, a pressure differential (partial vacuum) must be created by evacuating some of the air inside the fire pump.
To accomplish this, an airtight, noncollapsible waterway (hard intake hose) is needed between the pump and the body of water to be used.
![Page 240: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/240.jpg)
Operating from a Static Water Supply Source
The amount of friction loss in the hard intake hose is dependent upon the diameter and length of the hose.
The total pressure available to overcome all these pressure losses is limited to the atmospheric pressure at sea level – 14.7 psi.
![Page 241: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/241.jpg)
Operating from a Static Water Supply Source
Atmospheric pressure decreases 0.5 psi for each 1,000 feet of elevation gain.
Increasing the height of the lift decreases total pump capacity.
![Page 242: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/242.jpg)
Operating from a Static Water Supply Source
The maximum amount of vacuum that most pumps develop is around 22 inches or mercury. A reading anywhere near this is a warning that the pump is getting close to the limit of its ability.
![Page 243: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/243.jpg)
Cavitation Is the condition where water is being
discharged from the pump faster than it is coming in
Results if an attempt is made to increase the discharge from the pump beyond the point of maximum vacuum on the intake
Can damage the pump
![Page 244: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/244.jpg)
Indications of Cavitation Hose streams will pulsate, and the
pressure gauge on the pump will fluctuate
A popping or sputtering may be heard as the water leaves the nozzle
The pump will be noisy, sounding like gravel is passing through it
A lack of reaction on the pressure gauge to changes in the setting of the throttle
![Page 245: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/245.jpg)
Connecting to the Pump The apparatus may be able to park
directly at the drafting location, or may have to temporarily park short.
Once the hard intake hose and strainer are connected to the apparatus, they can be put into the desired position and the apparatus can then ease slowly into the final drafting spot.
![Page 246: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/246.jpg)
Connecting to the Pump
Before connecting sections of hard intake hose, check that the gaskets are in place and that couplings are free of dirt or gravel.
The strainer and hard intake hose must be coupled and made airtight.
![Page 247: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/247.jpg)
Connecting to the Pump It is usually easiest to connect the
hose to the intake fittings by first putting the strainer in the water and then pulling the apparatus into position.
Improper positioning of the hard intake hose can result in the formation of an air pocket that can prevent effective drafting.
![Page 248: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/248.jpg)
Connecting to the Pump
If a barrel strainer is used, the rope that was tied to it can be used to suspend the strainer above the bottom by tying it to the pumper or to a tree or other fixed object.
![Page 249: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/249.jpg)
Connecting to the Pump If the bottom slopes away steeply
from the edge, it may be possible to put a roof ladder in the water and rest the intake hose on it.
![Page 250: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/250.jpg)
Priming the Pump and Beginning Operation
Starts the draft operation
Transfer valve on two-stage pumps must be in the PARALLEL (VOLUME) position
All drains and valves must be closed
All unused openings must be capped to make the pump airtight before beginning
![Page 251: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/251.jpg)
Priming the Pump and Beginning Operation
On a positive displacement pump that is driven by the transfer case, the engine rpm should be set according to manufacturer’s instructions.
Most priming pumps are intended to work best between 1,000 and 1,200 rpm.
![Page 252: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/252.jpg)
Priming the Pump and Beginning Operation
When operating the primer control, the vacuum reading on the master intake gauge should read 1 inch for each 1 foot of lift.
Priming should not be stopped until all air has been removed and primer is discharging a steady stream of water.
![Page 253: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/253.jpg)
Priming the Pump and Beginning Operation
The entire action typically requires 10 to 15 seconds, but should not take more than 30 seconds.
If a prime has not been achieved in 30 seconds, stop priming and find out what the problem is.
![Page 254: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/254.jpg)
Priming the Pump and Beginning Operation
Causes of inability to prime:• An air leak that prevents the primer from
developing enough vacuum to successfully draft water
• Insufficient fluid in the priming reservoir• Engine speed (rpm) is too slow• Lift is too high• A high point in the hard intake hose is
creating an air pocket
![Page 255: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/255.jpg)
Priming the Pump and Beginning Operation
After successful priming, slowly increase throttle before opening any discharges. The pressure should be between 50 and 100 psi.
![Page 256: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/256.jpg)
Priming the Pump and Beginning Operation
Open discharge valves slowly while observing discharge pressure.• If pressure falls below 50 psi, pause to
allow it to stabilize. • If pressure continues to drop,
momentarily operate primer to eliminate air in the pump and restore pressure to original value.
![Page 257: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/257.jpg)
Priming the Pump and Beginning Operation
Constant movement of water through the pump prevents overheating and maintains a vacuum.
![Page 258: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/258.jpg)
Operating the Pump from Draft
Is the most demanding type of operation
Demands careful monitoring of gauges associated with the engine as well as those associated with the pump; any deviation from normal engine temperature is a signal that another pumper should be used
![Page 259: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/259.jpg)
Problems that Can Occur While Operating from Draft
Air leak on the intake side of the pump
Whirlpool allowing air to enter the pump
Air leakage due to defective packing in the pump
![Page 260: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/260.jpg)
Shutting Down the Operation
Slowly decrease the engine speed to idle
Take the pump out of gear
Allow the pump to drain
Operate the primer until primer oil or fluid comes out of the discharge from the priming pump
![Page 261: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/261.jpg)
Summary
Driver/Operators must:• Know how to operate fire pumps under a
variety of conditions• Be able to engage the pump, to make it
operational, and troubleshoot any problems that may develop.
![Page 262: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/262.jpg)
Summary Driver/Operators must:
• Choose the best available water source – onboard water tank, pressurized source, or static source – and provide this water to the pump
• Operate the pump to safely and effectively supply water to attack lines and support automatic sprinkler systems and standpipes in buildings so equipped
![Page 263: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/263.jpg)
Discussion Questions
1. What are the two basic pressurized water supply sources used to supply a fire pump?
2. What are some of the dangers of operating at a vacuum from a pressurized water source?
![Page 264: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/264.jpg)
Discussion Questions3. What checks should be made after making hydrant connections but before opening the hydrant?
4. Name methods for preventing the pump from overheating.
![Page 265: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/265.jpg)
Discussion Questions
5. Name the steps for shutting down a hydrant operation.6. Name some indications that the pump is cavitating.7. Name some common causes of an inability to prime the pump.
![Page 266: BASIC PUMP OPERATIONS BASED ON THE IFSTA DRIVER/OPERATOR PUMPER 2 ND EDITION](https://reader037.vdocument.in/reader037/viewer/2022102617/56649dbc5503460f94aadd90/html5/thumbnails/266.jpg)
RESA
Student Questions