Page 1: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International

Negative Pressure Unit

User Manual & Operating Instructions

Standard Equipment Range

NPU500/800 NPU1200

NPU1600

NPU2000 NPU5000

Page 2: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Negative Pressure Unit

User Manual & Operating Instructions

Manual Contents

1. Introduction and company history.

1.1 Company contact details

2 General Health and Safety advise

2.1 HSE website and contact details

3 Calculating Airflow Required for adequate air changes in enclosure

4 Transportation

4.1 Manual Handling

4.2 Storage

5 NPU Operation and Controls

5.1 On site safety and pre use checks

5.2 Attaching NPU to enclosures

5.3 Connecting to a suitable power supply

5.4 Fan operation and variable speed control

5.5 Manometer Gauge

5.6 Changing Pre Filters

5.7 Airflow loss (Ducting & Roving Heads)

6 NPU Service and Maintenance

6.1 Daily Checks

6.2 Routine Maintenance and Inspection

6.3 Service and Testing

6.4 Ordering Spares and Accessories for your NPU

6.5 Part List

Page 3: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

7. NPU Technical Information

7.1 Dimensions, Weights & Performance

7.2 Fan Performance (Fan Curves)

7.3 NPU Sounds Levels

7.4 Wiring Diagrams

8. Declaration of Conformity

9. Warranty

Page 4: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

Negative Pressure Unit

User manual & Operating Instructions

1. Introduction and company history.

Thank you for purchasing a Beacon Negative Pressure Unit.

We are sure our NPU will work hard for you and give you many years of

good service with an excellent return on your investment.

Beacon International Ltd have been manufacturing asbestos removal

equipment since the early 1990’s.

Since the company’s early beginnings, it has grown substantially and

now has large manufacturing plant covering 35,000 sq ft.

Beacon now specialise in manufacturing market leading equipment for

the asbestos removal markets around the world.

Please see our website for more details on our wide range of products.

www.beaconinternational.co.uk

This equipment has been manufactured by:

Beacon International Ltd

Elgee Works

Victoria Street

Desborough

Northants

NN14 2LX

Tel. 0044 1536 762 939

Email. [email protected]

Page 1

Page 5: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

Negative Pressure Unit

User manual & Operating Instructions

2. General Health and safety advise

Asbestos is a class 1 carcinogenic and must be handled

with care.

Being exposed to asbestos can cause asbestosis,

mesothelioma and lung cancer.

It is imperative that the correct training has been give

prior to any individual working with asbestos.

Approved breathing apparatus must be used at all times

whilst you are working with asbestos.

2.1 Health and Safety Executive.

For health and safety guidance relating to asbestos, please use the HSE

website http://www.hse.gov.uk/asbestos/

Page 2

Page 6: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

Negative Pressure Unit

User manual & Operating Instructions

3. Calculating Airflow Required for Adequate Air Changes in Enclosure

Prior to removing any asbestos, a secure enclosure must be constructed and

smoke tested to ensure there are no leaks in the structure.

Whilst asbestos removal is taking place, the polythene enclosure has to be

under negative pressure to ensure no contamination can escape into the

external atmosphere.

In order to maintain a constant negative pressure within the enclosure,

sufficient airflow must be maintained to keep the enclosure pressure at -8Pa.

To calculate the enclosure volume, multiply the width x length x height.

If the enclosure is an awkward shape, it may be easier to break it down to

smaller areas and add the total together.

Once you have the volume of the enclosure you must multiply this by the

number of required air changes to give you the airflow required.

Example: Enclosure size Width 9mtr x Length 8mtr x Height 3mtr = 216m3

Volume 216 x (Number of air changes) 8 = 1,728m3/h required.

For reference and information regarding airflow and enclosure calculations,

please follow the link below.

http://www.hse.gov.uk/research/rrpdf/rr988.pdf

Page 3

Page 7: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

Negative Pressure Unit

User manual & Operating Instructions

4. Transportation

Negative pressure units are designed to be portable and as light as possible.

The NPU is a machine containing electrical and mechanical moving

components, care must be taken during transportation to ensure no damage

is incurred.

When the NPU is being transported in a vehicle, it is essential that the

machine is secured properly and does not move around the vehicle

uncontrollably potentially causing internal damage to the machine.

When the machine is being loaded and unloaded onto vehicles, it is critical

that the machine is not dropped.

If any damage is incurred during use or handling, Beacon recommends that

you return the machine to your distributor for re-testing.

4.1 Manual Handling

When you are loading NPU’s on and off of vehicles, please ensure you lift

using the correct technique, keep your back straight and bend your legs.

Please the diagram below for recommended lifting values at various heights.

Page 4

Page 8: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

4.2 Storage

When storing your negative pressure units, the following instructions must be

adhered to:

a. Always store NPU’s in a dry storage area, wet or damp environments

will have a detrimental effect on the HEPA filter and internal electrical

components.

b. Never leave NPU’s outside in the rain, if ever the equipment does get

wet, you must dry off any water immediately.

c. Always store NPU’s upright on their feet or wheels, storing them on

their sides will potentially cause damage to the HEPA filters and under

certain circumstances could lead to HEPA filters failing or even

bursting.

d. Make sure that all NPU’s placed into storage are sealed and that no

unauthorised persons can accidentally gain access to this equipment

and subsequently contaminate themselves.

Page 5

Page 9: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

Negative Pressure Unit

User manual & Operating Instructions

5. NPU Operation and Controls

Beacon International have been manufacturing NPU’s for almost 25 years,

the company philosophy has always been to produce high quality easy to

operate equipment consistently.

5.1 On Site safety and pre use checks.

Prior to using any NPU on a work site, always check that the machine has no

obvious signs of external damage, if you are unsure or suspect the machine

may not be fit for purpose, contact your supervisor as soon as possible.

5.2 Attaching Negative Pressure Unit to an Enclosure

NPU’s are designed to create and maintain a negative pressure within an

asbestos removal enclosure. These machines are not designed to be used

inside an enclosure as this may cause internal electrical components to

become contaminated. This will in turn create a risk of transferring

contamination to maintenance work areas where unprotected personnel will

be at risk of asbestos exposure.

NPU’s should be attached to an enclosure with the main body of the machine

outside the work area, see photograph for example.

Page 10: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

5.3 Connecting to a Suitable Power Supply

For the NPU to function at its optimum output, it is vital that it is connected to

the correct power supply.

For the UK a 110 volt power supply is needed and for Europe a 230 volt

supply is required.

When using extension leads, check that the cable diameter is capable of

delivering the required voltage to the machine, excessive extension cables

will ultimately lead to a voltage drop.

If you are unsure if you have the correct voltage available, consult with a

qualified on site technician who will be able to test the power supply for you.

Please see the specification information in section 7 of this document for

more detailed information, amperage and watts etc.

5.4 Fan Switch Operation and Variable Speed Control

The NPU fan is operated by an On/Off Switch and the speed of the fan can be

controlled with the variable speed control which is fitted as standard to all

Beacon Negative Pressure Units.

The switches will illuminate when activated to confirm power is present.

Variable speed controller is operated by turn the control knob in a clockwise

direction for greater fan speed or in an anti-clockwise direction to lower fan

speed. See photograph below.

5.5 Manometer Gauge

Page 11: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

A manometer gauge is fitted to all Beacon NPU’s.

This device measures pressure inside the machine in comparison to external

atmospheric pressure outside, the gauge reading is used to determine the

condition of and will indicate to users when the filters are blocked.

5.6 Changing Pre Filters

The chart on manometer readings in the previous section (5.5) can be used to

determine when to replace pre-filters in the NPU.

Always use G4 pre filters to ensure that adequate protection is given to the

HEPA filter, using poor quality pre filters will dramatically reduce the life of

the HEPA filter.

When replacing a pre filter in an NPU, always make sure that the filter pleats

run vertically and not horizontally, see photograph.

5.7 Airflow Loss (Ducting & Roving Heads)

NPU MODEL GAUGE READING – CHANGE FILTERS NPU500 650PA

NPU800 650-700PA

NPU1200 950-1000PA

NPU2000 750-800PA

NPU5000 700-750PA

Page 12: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

Airflow capacity of NPU’s is classified in M3/h (cubic metres per hour).

When using NPU’s on an enclosure, there are factors that may reduce airflow

and must be taken into consideration.

Using exhaust ducting and or roving heads and inlet ducting will have a

significant influence on airflow.

Experiments were carried out in the UK by the HSE, see table below for data.

Page 13: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

Negative Pressure Unit

User manual & Operating Instructions

6. NPU Service and Maintenance

Negative pressure units need to be tested at intervals laid out in current

legislation by either the manufacturer or a company qualified to carry out

testing correctly.

6.1 Daily Checks

NPU’s in operation on site must be visually inspected on a daily basis to

ensure they are running without any problems, mechanical issues etc.

Any problem or failures must be reported immediately to the site supervisor

or foreman.

6.2 Weekly Inspections

Decontamination units, vacuum cleaners and negative pressure units must

be inspection on a weekly basis, these inspections need to be recorded into a

maintenance log record. The information collected on these forms is to be

noted, any problems are to be resolved by trained personnel.

For any major faults found, equipment will have to be returned to the

manufacturer or a suitably qualified company to carry out the necessary

repairs.

All data collected, including faults found, repairs carried out must be entered

into the service log which will be used as evidence that any issues have been

dealt with correctly for inspection or audit purposes.

Please see example maintenance log on the following page.

Page 6

Page 14: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

Maintenance Log Example

Page7

Equipment History Sheet – Weekly Inspections

Hygiene Unit Vacuum Cleaner Negative Pressure Unit

Model:

Unit Serial No.

Date of last test / / Date next test due / /

Date Approx Hours run

Inspected by Print & sign

Satisfactory YES/NO

Defects and / or remarks

Page 15: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

6.3 Service and Testing

Service and DOP (dispersed oil particulate) testing must be carried by a

qualified company, it is a legal requirement that companies carrying out

servicing and testing of asbestos removal equipment hold a HSE Ancillary

Licence.

Testing intervals can vary from one country to another.

UK – 6 Months

France – 12 Months

Nederland – 12 Months

Italy – 12 Months

Greece – 12 Months

Turkey 12 Months

Australia – 6 Months

New Zealand – 6 Months

When NPU’s have been DOP and electrically tested, a test certificate must be

supplied by the testing company, this certificate must be kept on record by

both the owner of the NPU and by the company carrying the testing.

Testing must be carried out by trained personnel using only calibrated test

equipment.

As the manufacturer, Beacon International automatically issue service

reminders in the UK when your NPU is due for service and testing.

If you have purchased your machine through a distributor, they will notify you

when your equipment is due for its periodic test.

6.4 Spares and Accessories for your NPU

Beacon International manufacture a range of negative pressure units as well

as a wide range of other asbestos removal equipment.

Spare parts and accessories are available for our whole range of equipment.

See parts list on the following page which includes part reference number

and description for each part that makes up each NPU.

Page 8

Page 16: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

NPU500/800 Parts List

Part No. Description

A023a NPU500/800 Transit Plate

C002 Manometer 0-1250Pa

C003 Manometer Tube

C004 Manometer Fitting

C005 Fitting Locknut

C040 NPU500/800 Handle Body

C041 NPU500/800 Handle Top

C046 NPU500/800 Cable Sheath

C068 NPU Transit Plate Clip

C069 NPU Transit Plate Strike

C085 Red BS8520-2:2009 Warning Label

C085 Yellow BS8520-2:2009 Warning Label

C094 NPU500/800 Cable Clamp

C109 Gasket 15mmx3mm

C001 Name Plate

E001 110v 16A Plug Top

E009 European Plug Top

E011 1.5mm 3 Core Arctic Blue Cable

E017 15 Amp Terminal Block

E019 2 Pole Switch

E020 Switch Cover

E026 Hourcounter

E030 Linear Speed Control

E031 Power Controller

E060 M6 Earth Bolt

E061 M6 Earth Nut

F003 12x12x2 Pre Filter

F019 12x12x6 HEPA Filter

M005 NPU500 110v Fan Assembly

M006 NPU500 230v Fan Assembly

M028 NPU800 230v Fan Assembly

M029 NPU800 110v Fan Assembly

P001 NPU500 CASE

Page 9

Page 17: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

NPU1200 Parts List

Part No. Description

C001 Name Plate

C002 Manometer

C003 Manometer Tube (Per Metre)

C004 Manometer Fitting

C005 Fitting Locknut

C024 Lifting Handle

C025 Alloy Knob

C030 76mm Vac Castor

C031 76mm Vac Castor c/w Brake

C068 NPU Transit Plate Clip

C069 NPU Transit Plate Strike

C085 Red Warning Label

C086 Yellow Warning Label

C093 Handle Back Plate

C109 Gasket (15x3mm) Per Metre

C110 NPU1200 Transit Plate

C111 Non Return flap

E001 110v 16A Plug Top

E009 European Plug Top

E012 2.5mm 3 Core Arctic Yellow Cable

E015 Conclamp Locknut

E017 15 Amp Terminal Block

E021 2 Pole Sealed Switch (Red)

E026 Hourcounter

E030 Linear Speed Control

E031 Power Controller

E044 Extended Cable Gland

E045 1.5mm Arctic Blue Supply Cable

E060 Earth Bolt

E061 Earth Nut

F003 12x12x2 Pre Filter G4

F011 12x12x4 Intermediate Filter F6

F022 12x12x12 HEPA Filter H13

M003 110v Nicotra Fan

M004 230v Nicotra Fan

P002 NPU1200 Case

Page 10

Page 18: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

NPU2000 Parts List

Part No. Description

A025a NPU2000 Transit Plate

C001 Name Plate

C002 Manometer

C003 Manometer Tube (Per Metre)

C004 Manometer Fitting

C005 Fitting Locknut

C024 Lifting Handle

C025 Alloy Knob

C030 76mm Vac Castor

C031 76mm Vac Castor c/w Brake

C068 NPU Transit Plate Clip

C069 NPU Transit Plate Strike

C093 Handle Back Plate

C109 Gasket (15x3mm) Per Metre

C230 NPU “B” Instrument Plate

E001 110v 16A Plug Top

E009 European Plug Top

E012 2.5mm 3 Core Arctic Yellow Supply Cable

E015 Conclamp Locknut

E017 15 Amp Terminal Block

E021 2 Pole Sealed Switch (Red)

E026 Hourmeter

E030 Linear Speed Control

E031 Power Controller

E044 Extended Cable Gland

E045 1.5mm 3 Core Arctic Blue Supply Cable

E060 Earth Bolt

E061 Earth Nut

F082a 15x15x4 Pre FilterG4

F023 380x380x292mm HEPA Filter H13

M003 110v Nicotra Fan

M004 230v Nicotra Fan

P017b NPU2000/2/B Case

Page 11

Page 19: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

NPU5000 Parts List

Part No. Description

A027a NPU5000 Transit Plate

C091 Name Plate (Small)

C002 Manometer

C003 Manometer Tube (Per Metre)

C004 Manometer Fitting

C005 Fitting Locknut

C024 Lifting Handle

C025 Alloy Knob

C032 100mm Vac Castor

C033 100mm Vac Castor c/w Brake

C068 NPU Transit Plate Clip

C069 NPU Transit Plate Strike

C109 Gasket (15x3mm) Per Metre

C230 NPU5000/B Control Plate

E001 110v 16A Plug Top

E009 European Plug Top

E013 4.0mm Arctic Yellow Supply Cable

E015 Conclamp Locknut

E017 15 Amp Terminal Block

E018 40A Terminal Block

E021 2 Pole Sealed Switch (Red)

E026 Hourmeter

E030 Linear Speed Control

E031 Power Controller

E044 Extended Cable Gland

E046 2.5mm 3 Core Blue Supply Cable (Per Metre)

E060 Earth Bolt

E061 Earth Nut

F074a 24x24x4 Pre Filter G4

F026 24x24x12 HEPA Filter H13

M003 110v Nicotra Fan

M004 230v Nicotra Motor

Page 12

Page 20: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Beacon International Ltd NPU User Manual and Operating Instructions

Negative Pressure Unit

User manual & Operating Instructions

7. NPU Technical Information

7.1 Dimensions Weights and Performance

Model NPU500 NPU800 NPU1200 NPU1600 NPU2000 NPU5000

Length mm 403 414 1010 545 915 988

Width mm 447 447 435 555 498 712

Height mm 449 449 532 550 560 848

Weight (Kg) 18 18 37 25 42 82

Motors 1 1 1 1 1 2

Motor Power Watts 240 320 1000 650 1200 2700

Voltage Available 110 / 230 110 / 230 110 / 230 110 / 230 110 / 230 110 / 230

Amperage 110v/230v 1.6 / 0.75 2.2 / 1.1 9.0 / 4.5 11.0/ 5.5 25.0/12.0

Airflow m3/h 550 800 1250 1600 2300 5500

Pre Filter G4 300x300x48 300x300x48 300x300x48 375x375x48 375x375x98 600x600x98

HEPA Filter 99.997%

305x305x150 305x305x150 305x305x292 380x380x200 380x380x292 610x610x292

Page 13

Page 21: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Negative Pressure Unit

User Manual & Operating Instructions

Centrifugal fan Specification

Voltage 230v AC

Frequency 50Hz

Phase Single

Poles 2

Capacitor start Yes

Variable speed Yes

Nominal power 1000watts

Horse power 1.35

Power consumption 1804 watts

Current consumption 7.6 amps

Speed 0-2700rpm

Fan Curve

Page 14

Page 22: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Negative Pressure Unit

User Manual & Operating Instructions

7.3 Sound Levels

NPU500/800

Distance Airflow 300m3/h 500m3/h 800m3/h

1.0 Mtr 71.5dB 74.8dB 75.7dB

5.0 Mtr 66.7dB 67.0dB 67.7dB

10.0 Mtr 63.2dB 64.3dB 64.8dB

NPU1200

Distance Airflow 600m3/h 900m3/h 1200m3/h

1.0 Mtr 76.6dB 80.8dB 82.5dB

5.0 Mtr 72.7dB 73.9dB 75.3dB

10.0 Mtr 69.8dB 70.1dB 72.6dB

NPU1600

Distance Airflow 750m3/h 1000m3/h 1600m3/h

1.0 Mtr 76.8dB 79.2dB 81.6dB

5.0 Mtr 71.4dB 73.9dB 74.8dB

10.0 Mtr 68.1dB 71.3dB 72.0dB

NPU2000

Distance Airflow 1000m3/h 1500m3/h 2000m3/h

1.0 Mtr 76.4dB 79.8dB 81.4dB

5.0 Mtr 72.3dB 73.5dB 74.4dB

10.0 Mtr 69.2dB 69.8dB 72.2dB

NPU5000

Distance Airflow 1250m3/h 3000m3/h 5000m3/h

1.0 Mtr 75.1dB 81.5dB 84.8dB

5.0 Mtr 70.3dB 74.7dB 78.9dB

10.0 Mtr 68.5dB 73.0dB 76.3dB

Airflow readings taken with an ambient sound level of 42.8dB

Page 15

Page 23: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Negative Pressure Unit

User Manual & Operating Instructions

Wiring Diagram

Single Motor NPU’s

NPU500 NPU800 NPU1200 NPU1600 NPU2000

Negative Pressure Unit Electrical Diagram (Single Fan Motor )

With Speed Regulation

Hours Run Meter

Fan No1

Switch

Triac Speed

Regulator

250K

Pot

230vac

Fan Motor

No.1

Page 16

Page 24: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Negative Pressure Unit

User Manual & Operating Instructions

Wiring Diagram

Twin Motor NPU’s

NPU5000

Negative Pressure Unit Electrical Diagram (Twin Fan Motor )

With Speed Regulation

Hours Run Meter Fan Motor

No.2

Fan No1

Switch

Fan No.2

Switch

Triac Speed

Regulator

250K

Pot

230vac

Fan Motor

No.1

Page 17

Page 25: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s
Page 26: Beacon International Negative Pressure Unit User Manual ... · Beacon International Ltd have been manufacturing asbestos removal equipment since the early 1990’s. Since the company’s

Negative Pressure Unit

User Manual & Operating Instructions

8 Warranty

Beacon International Ltd offer warrant to the original purchaser of equipment.

Warranty will cover defects in both materials and workmanship for the period of one year from date of purchase.

The warranty excludes any consumable parts such as motor brushes,

blocked filters or general wear and tear.

The warranty also excludes any accidental or intentional damage to equipment.

If the equipment is supplied through a distributor, the warranty must be claimed for through that distributor.

No claim will be granted without evidence of the validity of the claim, ie. Proof of purchase.

Beacon International Ltd reserve the right to charge in full or part for any repairs that are a result of misuse, neglect or wear and tear.

Page 19