bel valve - cladding & extra tungsten carbide deposit...

18
Presented by R.Baskar, AMIE (Mech) ASNT NDT Level III RT,UT,PT & MT CSWIP 3.2 AWS SCWI BEL Valve - Cladding & Extra Tungsten Carbide Deposit issue Case Study

Upload: others

Post on 04-Jan-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

Presented byR.Baskar, AMIE (Mech)

ASNT NDT Level III RT,UT,PT & MT

CSWIP 3.2

AWS – SCWI

BEL Valve - Cladding & Extra Tungsten Carbide Deposit issue – Case Study

Page 2: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

2GE Confidential and Proprietary Information

GE2007 All Rights Reserved

• Bond integrity and volumetric

examination of Weld overlay (cladding)

• Extra material Deposit (Tungsten Carbide)

BEL Valve - Cladding & Extra Tungsten Carbide Deposit issue –Case Study

Page 3: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

3GE Confidential and Proprietary Information

GE2007 All Rights Reserved

BEL Valve - Cladding & Extra Tungsten Carbide Deposit issue – Case Study

Technical Justification

follows

Page 4: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

4GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Bond integrity and volumetric examination of

Weld overlay (clading)

BEL Valve – Cladding issue – Case Study

Page 5: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

5GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Bond integrity and volumetric examination of

Weld overlay (clading)

BEL Valve – Cladding issue – Case Study

Lack of bonding at

weld fusion face

Page 6: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

6GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Ultrasonic Indication from overlay fusion face

BEL Valve – Cladding issue

Page 7: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

7GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Ultrasonic equipment REFERENCE LEVEL

(RL) set through reference block

BEL Valve – Cladding issue

RL Set at 90% FSH

Page 8: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

8GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Ultrasonic Testing - Reference block

BEL Valve – Cladding issue

Flat bottom Drilled Hole Reference Reflector

Weld Interface

Page 9: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

9GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Bond integrity and volumetric examination of weld overlay (cladding) in accordance with API 6A

Page 10: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

10GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Ultrasonic Testing - Acceptance Criteria

BEL Valve – Cladding issue

Reference : API 6A, Para. 7.4.2.3.15 - b - 2

Page 11: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

11GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Ultrasonic Testing - Acceptance Criteria

BEL Valve – Cladding issue

• RL Set at 90% FSH• Rejection level for

single indication

Rejection level for multiple indication 45% FSH

Page 12: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

12GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Ultrasonic Testing - Acceptance Level

BEL Valve – Cladding issue

Rejection level for Multiple indication

Rejection level for Multiple indication

Multiple indication from 11” ball (S.No. 48122)

Multiple indication from 9” ball (S.No. 48140)

No indication

Page 13: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

13GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Ultrasonic Testing - Acceptance Criteria

based on area

BEL Valve – Cladding issue

Reference : ASME / ASTM SA 265 Para. 13.3.3 and 13.3.4

Based on area it is only 0.13 – 0.14%, hence it can be ignored

Page 14: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

14GE Confidential and Proprietary Information

GE2007 All Rights Reserved

• Extra material Deposit (Tungsten Carbide)

Video Display – Tungsten Carbide deposit

BEL Valve – Extra material Deposit (Tungsten Carbide) issue – Case Study

Page 15: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

15GE Confidential and Proprietary Information

GE2007 All Rights Reserved

• Extra material Deposit (Tungsten Carbide)

During Tungsten carbide coating at outer surface, by process error ROBO equipment

deposit some portion with Tungsten Carbide into inner surface area of bore. Deposit uptomax. 3mm.

BEL Valve – Extra material Deposit (Tungsten Carbide) issue – Case Study

Extra material Deposit

(Tungsten Carbide)

Page 16: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

16GE Confidential and Proprietary Information

GE2007 All Rights Reserved

This Extra material deposit confirmed following checking:

• Visual inspection, by surface color difference between Tungsten Carbide coating and cladding material deposit area

• During dye penetrant testing noticed red color contrast at Tungsten Carbide area. Which is probably due to porous material observed penetrant and resulting red color contrast at that location.

• Checked with PMI and noticed 80 – 84 % of Tungsten, other location 55 – 60 % Nickel

• Checked hardness test and noticed 50 – 55 HRC, other cladded area 32 – 35 HRC

• Checked with coating thickness gauge, it noticed 1 to 3 mm coating thickness

• Inner diameter measured and noticed reduced dimension, than the nominal bore dimension.

• General information, this extra material deposit is very smooth transition and stress raise free.

Based on the above check, it is clearly shows Tungsten Carbide deposit

BEL Valve – Extra material Deposit (Tungsten Carbide) issue – Case Study

Page 17: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

17GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Table shows Tungsten Carbide Details

BEL Valve – Extra material Deposit (Tungsten Carbide) issue – Case Study

Page 18: BEL Valve - Cladding & Extra Tungsten Carbide Deposit ...2.imimg.com/data2/KX/KO/MY-/bevalve-casestudy-towards-cladding-and... · Presented by R.Baskar, AMIE (Mech) ASNT NDT Level

18GE Confidential and Proprietary Information

GE2007 All Rights Reserved

Suggested Conclusion for Cladding

Based on the review of Ultrasonic indication evaluations, the

indication in the cladding are well within acceptable limit and it will

not affect the integrity of the valves. The valves are fit for purpose.

Leave indication in the cladding as is.