below ground waterproofing diagrams
TRANSCRIPT
![Page 1: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/1.jpg)
Diagrams to assist with
BELOW GROUNDWATERPROOFING
![Page 2: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/2.jpg)
![Page 3: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/3.jpg)
![Page 4: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/4.jpg)
![Page 5: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/5.jpg)
![Page 6: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/6.jpg)
![Page 7: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/7.jpg)
![Page 8: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/8.jpg)
![Page 9: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/9.jpg)
Foundation wall with drainage system
![Page 10: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/10.jpg)
Foundation wall with slab below ground (1)
![Page 11: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/11.jpg)
Foundation wall with slab below ground (2)
![Page 12: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/12.jpg)
Pile cap waterproofing
![Page 13: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/13.jpg)
Field grade beam waterproofing
![Page 14: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/14.jpg)
N.B: All penetrations should be 300mm fromwalls, curbs, up stands, and be placed aminimum of 300mm apart.
Vertical penetration for below grade membrane
![Page 15: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/15.jpg)
N.B: All penetrations should be 300mm fromwalls, curbs, up stands, and be placed aminimum of 300mm apart.
Foundation wall with poured in place pipe penetration
![Page 16: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/16.jpg)
N.B: All penetrations should be 300mm fromwalls, curbs, up stands, and be placed aminimum of 300mm apart.
Pipe sleeve penetration detail
![Page 17: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/17.jpg)
N.B: All penetrations should be 300mm fromwalls, curbs, up stands, and be placed aminimum of 300mm apart.
Foundation wall – brick ledge termination
![Page 18: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/18.jpg)
Waterproofing termination at ground
APPROPRIATE SEALANTCOMPATIBLE WITHWATERPROOFINGMEMBRANE
TERMINATION BAR FASTENEDWITH APPROPRIATE FASTENERSAT APPROX 12O O.C.
APPROPRIATE SEALANT
SHEET METALCOUNTERFLASHINGAPPROPRIATE FOR MASONARYCONSTRUCTION TYPE
GRADE
BACKFILL
WATERPROOFINGMEMBRANE
PROTECTION / DRAINAGE/ INSULATION COURSE
WATERPROOFINGTERMINATION10cm MIN ABOVEGRADE
SURFACE MOUNTEDSHEET METALCOUNTERFLASHING
INSTALL APPROPRIATESEALANT AND TOOL TOFACILITATE RUN OFF
![Page 19: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/19.jpg)
Foundation wall – exterior cladding tie-in
WATERPROOFINGTERMINATION10cm MIN ABOVEGRADE
METAL OR ULTRAVIOLETRESISTANT MATERIAL
![Page 20: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/20.jpg)
Blind side waterproofing at ground beam
![Page 21: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/21.jpg)
Blind side waterproofing at slab
![Page 22: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/22.jpg)
Perimeter edge detail at ground compatible materials
![Page 23: Below Ground Waterproofing Diagrams](https://reader033.vdocument.in/reader033/viewer/2022061101/629bd6cc85159e54b26ea789/html5/thumbnails/23.jpg)
Perimeter edge detail at ground – dissimilar materials