belt weigher calibration

2
CALIBRATING WEIGH SCALES USING DROP TEST Checks or calibrations with check weights cannot reproduce the actual circumstances to perfection. Highly accurate weighing results can be achieved only by various measurements with material and subsequent correction. 1. Note down the Feed rate (I tph) say its MA, 2. Collect material over 1 meter of Belt ( say X kg), 3. Note down time taken for 1 meter of Belt (say T sec), 4. Note down Old value of Parameter D 02 (Old) 5. Calculate Actual federate as MW = (X * 3.6)/ T. Example: Suppose in INTECONT it’s reading as MA = 5 tph and MW = 4.9 tph is calculated feed rate by means of drop test. Also suppose D02 ( Old)= 1. Then Enter computed value into Parameter D 02. STEPS TO ACCESS PARAMETER DO2 Call Function Distributor Scroll Programming function into lower display field and acknowledge Select ENTER PAR. Function Enter password 07734

Upload: singhrakes

Post on 15-Sep-2015

214 views

Category:

Documents


0 download

DESCRIPTION

bkjn

TRANSCRIPT

  • CALIBRATING WEIGH SCALES USING DROP TEST

    Checks or calibrations with check weights cannot reproduce the actual circumstances to perfection.

    Highly accurate weighing results can be achieved only by various measurements with material and

    subsequent correction.

    1. Note down the Feed rate (I tph) say its MA,

    2. Collect material over 1 meter of Belt ( say X kg),

    3. Note down time taken for 1 meter of Belt (say T sec),

    4. Note down Old value of Parameter D 02 (Old)

    5. Calculate Actual federate as MW = (X * 3.6)/ T.

    Example:

    Suppose in INTECONT its reading as MA = 5 tph and MW = 4.9 tph is calculated feed rate by means of drop test.

    Also suppose D02 ( Old)= 1. Then

    Enter computed value into Parameter D 02.

    STEPS TO ACCESS PARAMETER DO2

    Call Function Distributor

    Scroll Programming function into lower display field and acknowledge

    Select ENTER PAR. Function

    Enter password 07734

  • Display shows title of first parameter block

    Move through blocks A,B, up and down. Block letter flashes.

    Select block. Parameter selected last is displayed.

    Move through parameter numbers within a block.

    Prepare input

    Selection parameters: Value flashes. Scroll desired value into lower display field.

    For left-right

    Numeric values

    Acknowledge input.