bench top autoclaves vacuum autoclaves autoclave tapes...

14
Order by phone 01342 826836 Order on-line www.ecomcat.co.uk Order by fax 01342 826771 Website www.jencons.co.uk Prestige Medical Autoclaves 6 Take a look at our latest products on www.ecomcat.co.uk Series 2100 Classic Benchtop Autoclave The Series 2100 clinical autoclaves from Prestige Medical are suitable in nearly all areas of infection control. The Series 2100 classic have been designed to international standards for safety and performance and are fully CE marked to the latest Medical Devices Directive 93142/ EEC (MDD). All Series 2100 autoclaves include the following contents: certificate of compliance, performance test certificate, warranty registration card, multi-lingual instruction manual, electrical cord set and spare 10 amp fuses (x2). Specifications Standard Extended Extended Plus Extended Plus Model 210001 210002 210004 210024 Chamber capacity, litres 9 12 12 12 Maximum width x height, mm 340x335 340x420 340x420 340x420 Chamber h x diameter, mm 236x210 328x210 328x210 328x210 Maximum instrument length, mm 228 290 290 290 Maximum load weight, kg 3 4 4 4 Sterilising temperature, ºC 126 126 126 121 Cycle time-nominal, mins 22 22 22 N/A Operating pressure, bar 1.4 1.4 1.4 1.0 Water charge*, litres 0.75 0.75 0.75 0.75 * Distilled/ de-ionised water Cat. No. Description Price 119-003 210001 Standard Autoclave -126ºC/11 minute cycle complete with standard POA small contents plus instrument basket, instrument tray, lifting device and ‘V’ support 119-008 210002 Extended Autoclave -126ºC/11 minute cycle standard contents plus POA large instrument basket and ‘V’ support 119-009 210004 Extended ‘Plus’ Autoclave -126ºC/11 minute cycle complete with POA standard contents plus large instrument basket and ‘V’ support. Supplied with temperature and pressure gauges and thermocouple entry port 119-006 210024 Extended ‘Plus’ Media Autoclave -121ºC/22 minute cycle complete POA with standard contents plus large instrument basket and ‘V’ support. Supplied with thermal jacket, temperature and pressure gauges and thermocouple entry port Accessories 119-001 TST indicator strip 121°C/15 min POA 119-002 Dual TST indicator strip 121°C/15 min and 134°C/3 min POA Omega 2 and Omega Media Autoclave The Omega range from Prestige Medical are stylish, compact and fully portable electronic autoclaves benefiting from a comprehensive range of features. The Omega 2 has been designed to meet the requirements of the British Standard BS3970: Part 4:1990 and is in full compliance with this standard. It has a sterilising cycle of 134ºC for 3 minutes. The Omega Media is designed for sterilising culture and operates at 121ºC ±2ºC for a 22 minute sterilising period. It has an electronic mechanical interlock set to unlock the lid at a temperature of 80ºC. Both Omega autoclaves include the following standard contents; certificate of compliance - vessel (BS3970: Part4: 1990), performance test certificate, warranty registration card, instruction manual and electrical cord set. Cat. No. Description Price 119-000 Omega Media Autoclave, 121ºC/22 minute cycle POA 119-010 Omega 2 Autoclave, 134ºC/3 minute cycle POA Accessories 119-001 TST Indicator Strip 121°C/15 min (box of 50) POA 119-002 Dual TST Indicator Strip 121°C/15 min and 134°C/3 min (box of 50) POA For sterilizing media or petri dishes, ampoules or instruments Automatic operating cycle Integral pressure and temperature gauges Lifetime heating element guarantee 10 year pressure vessel guarantee CE marked to the MDD Large instrument basket and V support included 10 litre capacity 2 chamber capacities Choice of sterilising cycle; 126°C for 11 mins or 121°C for 16 mins Two stage ‘overpressure’ protection Optional temperature and pressure gauges CE marked to the MDD 119-010 119-003 119-008

Upload: phungnhi

Post on 15-Dec-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukPrestige Medical

Autoclaves

6 Take a look at our latest products on www.ecomcat.co.uk

Series 2100 Classic Benchtop AutoclaveThe Series 2100 clinical autoclaves from Prestige Medical are suitable in nearly all areas of infectioncontrol. The Series 2100 classic have been designed to international standards for safety andperformance and are fully CE marked to the latest Medical Devices Directive 93142/ EEC (MDD).

All Series 2100 autoclaves include the following contents: certificate of compliance, performance testcertificate, warranty registration card, multi-lingual instruction manual, electrical cord set and spare 10amp fuses (x2).

SpecificationsStandard Extended Extended Plus Extended Plus

Model 210001 210002 210004 210024Chamber capacity, litres 9 12 12 12Maximum width x height, mm 340x335 340x420 340x420 340x420Chamber h x diameter, mm 236x210 328x210 328x210 328x210Maximum instrument length, mm 228 290 290 290Maximum load weight, kg 3 4 4 4Sterilising temperature, ºC 126 126 126 121Cycle time-nominal, mins 22 22 22 N/AOperating pressure, bar 1.4 1.4 1.4 1.0Water charge*, litres 0.75 0.75 0.75 0.75

* Distilled/ de-ionised water

Cat. No. Description Price

119-003 210001 Standard Autoclave -126ºC/11 minute cycle complete with standard POAsmall contents plus instrument basket, instrument tray, lifting device and ‘V’ support

119-008 210002 Extended Autoclave -126ºC/11 minute cycle standard contents plus POAlarge instrument basket and ‘V’ support

119-009 210004 Extended ‘Plus’ Autoclave -126ºC/11 minute cycle complete with POAstandard contents plus large instrument basket and ‘V’ support. Supplied with temperature and pressure gauges and thermocouple entry port

119-006 210024 Extended ‘Plus’ Media Autoclave -121ºC/22 minute cycle complete POAwith standard contents plus large instrument basket and ‘V’ support. Supplied with thermal jacket, temperature and pressure gauges and thermocouple entry port

Accessories

119-001 TST indicator strip 121°C/15 min POA

119-002 Dual TST indicator strip 121°C/15 min and 134°C/3 min POA

Omega 2 and Omega Media AutoclaveThe Omega range from Prestige Medical are stylish, compact and fully portable electronic autoclavesbenefiting from a comprehensive range of features.

The Omega 2 has been designed to meet the requirements of the British Standard BS3970: Part 4:1990and is in full compliance with this standard. It has a sterilising cycle of 134ºC for 3 minutes.

The Omega Media is designed for sterilising culture and operates at 121ºC ±2ºC for a 22 minutesterilising period. It has an electronic mechanical interlock set to unlock the lid at a temperature of 80ºC.

Both Omega autoclaves include the following standard contents; certificate of compliance - vessel(BS3970: Part4: 1990), performance test certificate, warranty registration card, instruction manual andelectrical cord set.

Cat. No. Description Price

119-000 Omega Media Autoclave, 121ºC/22 minute cycle POA

119-010 Omega 2 Autoclave, 134ºC/3 minute cycle POA

Accessories

119-001 TST Indicator Strip 121°C/15 min (box of 50) POA

119-002 Dual TST Indicator Strip 121°C/15 min and 134°C/3 min (box of 50) POA

■ For sterilizing media or petri dishes,ampoules or instruments

■ Automatic operating cycle■ Integral pressure and temperature gauges■ Lifetime heating element guarantee

■ 10 year pressure vessel guarantee■ CE marked to the MDD■ Large instrument basket and V support

included■ 10 litre capacity

■ 2 chamber capacities■ Choice of sterilising cycle;

126°C for 11 mins or 121°C for 16 mins

■ Two stage ‘overpressure’ protection■ Optional temperature and pressure gauges■ CE marked to the MDD

119-010

119-003

119-008

Page 2: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

AutoclavesDixons

Take a look at our latest products on www.ecomcat.co.uk 7

118-052

118-056

118-058

Control panel

Portable Electric AutoclavesThe Dixons range of portable autoclaves are designed for safety and reliability, yet remain easy to useand maintain. They are fitted with an automatic cut-out to prevent them boiling dry. The lid is removablefor full width access, items can either be placed in the inner liner provided or in accessory dressing drumsor basket. The ST19T is constructed of die cast aluminium and the ST2228 and ST3028 are constructed ofstainless steel. All models are heated with a single internal element. Temperature is controlled by anelectronic temperature controller and a thermocouple. Supplied complete with inner liner with handles.

SpecificationsModel ST19T ST2228 ST3028Chamber capacity, L 14 22 30Internal dimensions(diameter/usable height), mm 280/230 280/360 280/490

Heat source Internal electric element, 2.0kW (all models)Hydraulic test pressure 30 psi (2 bar) (all models)Safe working pressure 1.3 bar (all models)Standard/max working temperature, °C 121/121 (all models)Overall dimensions (wxdxh), mm 420x400x520 370x390x570 370x390x700Net weight, kg 15 21 23

Cat. No. Description Price

118-052 ST19T Aluminium autoclave, thermostatically controlled POA

118-054 ST2228 Stainless steel autoclave, thermostatically controlled POA

118-056 ST3028 Stainless steel autoclave, thermostatically controlled POA

Accessories for ST19T, ST2228, ST3028 and Nexus 3028

Cat. No. Description Dimensions (diaxdepth), mm Price

118-059 Small dressing drum, stainless steel 240x120 POA

118-060 Large dressing drum, stainless steel 240x240 POA

118-061 Bottle rack, stainless steel, for 4x1L media bottles — POA

118-062 Wire mesh basket with lifting handle, stainless steel 240x220 POA

118-063 Wire mesh basket with lifting handle, stainless steel 240x440 POA

Dixons models with automatic cycle control are available please enquire for details on 01342 826836.

Nexus 3028 Portable AutoclavesThe Nexus models are fully thermally insulated and portable. They are mounted on locking castors to alloweasy movement from site to site. The wipe clean keyboard and screen are situated on top of the lid. Thescreen has a resolution of 4 lines x 40 columns. The control system is user friendly with three keys to alterall the parameters of each cycle. Both models have a 30 litre chamber which can hold 8 x 1L media bottles.The Nexus 3028 is available with integrated 24 column printer to record time, temperature and pressurethroughout the cycle, serial number, date and cycle number. Heated with an internal 2kW electric element.

SpecificationsChamber capacity, L 30 Cycle temperature range, °C 100 to 138Internal dimensions Variable time 1min–99hrs(diameter/usable), mm 280/490 Dimensions (wxdxh), mm 450x710x1010

Chamber material Stainless steel, 316 Net weight, kg 80Safe working pressure 2.6 bar

Cat. No. Description Price

118-057 Nexus 3028 stainless steel autoclave POA

118-058 Nexus 3028 stainless steel autoclave with printer POA

For accessories – see above.

■ 12 preset and 12 custom cycles■ Load temperature cycle control■ Quick lid release mechanism■ Pressure and temperature interlock■ Fan assisted cooling■ Media stay warm facility■ RS232 data output

■ No plumbing required■ Cycle counter■ Complies with H&SE PM73■ Designed and constructed in accordance

with BS2646: Part 1: 1993 and PD5500: 2000: Cat 3

■ CE marked

■ No plumbing required■ Lid locking safety to H&SE PM73■ Electrically tested in compliance with BS3456

Part 101 1987

■ Suitable for culture media■ CE marked

Page 3: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

The New Touchclave-Lab is one of the most

significant and exciting autoclaves to be launched onto the

market in recent years. The features included are all designed

to maximize value and throughput, making it one of the

most complete systems available.

Available in sizes from 150 to 300 litres, Touchclave®

laboratory autoclaves have a unique combination of

features to assist the operator and improve efficiency:

• Touch-screen controls

• Multi-program system

• Automatic internal data archiving

• Innovative interlocked, vertical easy-glide sliding door

• Fully portable slim-line product

– ideal for the space conscious lab

• Rectangular chamber

LTE Scientific Ltd.

Greenbridge Lane, Greenfield,

Oldham, OL3 7EN, United Kingdom.

making

Quality more

AffordableTouchclave-Lab

Tel: +44 (0)1457 876221 • Fax: +44 (0)1457 870131

[email protected] • www.lte-scientific.com

Other options available on this product include combined vacuum and air ballast

systems and effluent-retention (cat.3).

For more details contact LTE Scientific.

For more details on this and other LTE Scientific products please contact Jencons-PLS Technical Office.

Tel: 01342 826836 Fax: 01342 826771 Email: [email protected]

Page 4: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

AutoclavesLTE

Take a look at our latest products on www.ecomcat.co.uk 9

115-060

115-061 shown with printer 115-180

New

Falcon 30 - Rectangular-Section Bench Top Autoclaves The Falcon 30 is available with a choice of uni-program or microprocessor control systems. The Uni-program system is ideal where the same cycle is repeated regularly. The operator simply keys in theparameters once. These parameters are then stored in the memory until altered. As an alternative, abrand new versatile multi-program control system has been introduced on the Falcon 30. See below formore details on the new Falcon Touchclave-R.■ Accommodates up to eight 1-litre bottles■ Protection against low water level is provided by a cut-out device

Touchclave-R Touchscreen Multi-Program System Falcon and Osprey Touchclave-R autoclaves are equipped with a control system that incorporates apowerful PLC combined with an easy to use touchscreen, through which all commands, cycle data,program data and alarms are inputted and displayed.

This versatile system gives users a choice of selecting load-specific cycles from a menu or developingtheir own cycle profile. Eight cycles can be stored into the memory as standard and optional memoryexpansion is available to increase the number of available cycles to twenty.

Load Specific Cycles - are selected by pressing the appropriate ‘on-screen’ cycle title icon and thenfollowing the on-screen instructions. The cycles are pre-programmed to optimise air removal and coolingprofiles for each load type. Various parameters can be adjusted to suit the necessary application require-ments. There is also the option to change the cycle title.

Once the programs are stored in the memory, starting the cycle could not be easier. A cycle menu isbrought up on screen, allowing the required cycle to be selected. For those who need their cycles to betraceable, there is a facility to input operator ID and Batch information at this stage. There is also a facilityto program a delayed cycle start, which is particularly useful for maximising the use of the autoclave.During the cycle, information is constantly displayed on the touchscreen. Every stage of the cycle carriesa different information screen. A fully integrated thermal paper printer, tractor printer or chart recorderis available as an option, if a hard copy printout is required. It is possible to add internal data archiving asan option to all Touchclave-R Falcon and Osprey models.

On completing a successful cycle, the screen will show the ‘Passed’ display. If a fault occurs during thecycle, ‘Failed’ will be displayed on the screen, with details of the fault conditions highlighted on aseparate screen. This can be accessed by the operator but only acknowledged by those with a supervisoraccess code. All fault conditions will also be printed where applicable.

Specification

Cat. No. Description Price

115-060 Falcon 30 autoclave, uni-program model POA

115-061 Falcon 30 autoclave, Touchclave-R model POA

Options and AccessoriesEffluent Retention This option should be specified where Cat.3 material is being processed. Exhaust filtration is achievedthrough a 0.2 micron microbiological filter and effluent is sterilised before discharge.

Cat. No. Description Price

115-063 Morrison discard container - Size 1 (hxwxd), mm 230x430x230 POA

115-062 Basket, perforated stainless - Size 1 (hxwxd), mm 230x430x230 POA

115-180 Thermal data printer (Touchclave-R models only)* POA

115-004 Keep warm facility (Touchclave-R models only) POA

115-005 Internal data archiving (Touchclave-R models only) POA

115-175 Effluent retention system* POA

* These items are factory fitted and must be specified at the time of ordering the autoclave.

Other options include:NHS Upgrade Package - A number of additional features can be incorporated into the autoclave to bringit in line with the specific requirements of HTM2010. This can be discussed on an individual basis.

Please contact our Technical Office on 01342 826836 for details.

Chamber capacity, litres 30Chamber dims. (hxwxd), mm 265x225x450External dims. (hxwxd), mm 735x483x585Weight, kg 110

Power, kW 2.6Electrical supply 13A, 220/240VNo. of shelves/positions 1/1No. of containers/baskets (optional) 1x size 1

Page 5: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukLTE

Autoclaves

10 Take a look at our latest products on www.ecomcat.co.uk

115-068 shown with printer115-180

Osprey - Cylindrical Section Autoclaves Osprey autoclaves have cylindrical chambers and have been designed to the highest standards yet witheconomy in mind. These comprehensive and highly versatile ranges incorporate a wide variety of featuresto suit most requirements. Steam is generated by heating water in a reservoir within the chamber. Achoice of push button or fully automatic water-fill system can be fitted to most models, allowing thechamber to be topped up after each cycle either with or without operator intervention.

■ Available in seven chamber sizes - 40, 70, 150, 380L (front-loading) and 50, 100, 130L (top-loading)■ Protection against low water level is provided by a cut-out device■ The Osprey 40 is a bench top model

Osprey autoclaves are available with a choice of microprocessor control systems. The Uni-Program system isideal where the same cycle is repeated regularly. The operator simply keys in the parameters once. Theseparameters are then stored in the memory until altered. As an alternative, a brand new versatile multi-program control system, the Touchclave-R, has been introduced to the Osprey. See page 9 for more details.

Specifications Model Osprey 40 Osprey 70 Osprey 150 Osprey 380 Osprey 50 Osprey 100 Osprey 130Loading position Front Front Front Front Top Top TopCapacity, litres 40 70 150 380 50 100 150Chamber dimensions (dia.xd), mm 343x430 350x640 500x750 700x1000 350x520 457x610 457x800Overall dimensions (hxwxd), mm 822x485x700 1385x530x1145 1430x720x1080 1715x950x1540 1147x520x876 1100x560x840 1290x560x840Weight, kg 75 125 305 625 105 170 185Power, kW 2.5 5.0 7.5 13.5 5.0 5.5 5.5Electrical supply, V 240 240 240 400–440 240 240 240No. of shelves/pos. 1/1 1/1 2/2 2/2 1/1 1/1 1/1No. of containers/baskets (optional) 1x size 8 2x size 7 1x size 7 ———— 2x size 5 2x size 6 ————

with 1x size 4

Uni-program/ Cat No. 115-271 115-069 115-067 115-000 115-071 115-065 115-002

Price POA POA POA POA POA POA POA

Touchclave-R/ Cat No. 115-272 115-070 115-068 115-001 115-072 115-066 115-003

Price POA POA POA POA POA POA POA

Options and AccessoriesVacuum System/Air Ballast Two ultra-efficient combined vacuum and air ballast systems for use on all Osprey models (except Osprey 40). By utilising a liquid ring vacuum pump, Osprey modelsfitted with this option can achieve vacuum levels of 200mbarA. A vacuum program is incorporated into the Touchclave-R control system, which provides a Pre-ster-ilisation pulsed vacuum stage for excellent air removal. In addition a post-sterilisation pulsed post-vacuum stage at the end of the cycle will assist with drying.

The optional enhanced vacuum system has been designed to offer improved levels of load dryness at the end of the cycle. The air ballast system is ideal whenprocessing sealed liquids, as it reduces the risk of container rupture and helps reduce overall cycle times.

Effluent Retention This option should be specified where cat.3 material is being processed. Exhaust filtration is achieved through a 0.2 micron microbiological filter and effluentis sterilised before discharge

Cat. No. Description Price

115-180 Thermal data printer (Touchclave-R models only)* POA

115-075 Condensate unit (top-loading models)* POA

115-073 Condensate unit (front-loading models, POAexcept Osprey 40)*

115-006 Effluent retention system* POA

115-007 Vacuum system (Touchclave-R models, except Osprey 40) POA

115-008 Vacuum system with enhanced drying facility POA(Touchclave-R models, except Osprey 40)

115-004 Keep warm facility (Touchclave-R models only) POA

115-005 Internal data archiving (Touchclave-R models only) POA

115-009 Fully automatic water fill system (Osprey 70, 150 & POA380 Touchclave-R models only)*

115-149 Push-button water fill system (Osprey 70, 150 & 380)* POA

Cat. No. Description Price

Morrison discard containers

115-112 Size 4 (hxwxd), mm 288x395x290 POA

115-146 Size 5 (diaxh), mm 326x220 POA

115-147 Size 6 (diaxh), mm 433x260 POA

115-148 Size 7 (hxwxd), mm 250x215x300 POA

115-010 Size 8 (hxwxd), mm 220x236x360 POA

Baskets, perforated stainless

115-153 Size 4 (hxwxd), mm 288x395x290 POA

115-080 Size 5 (diaxh), mm 326x220 POA

115-154 Size 6 (diaxh), mm 433x260 POA

115-155 Size 7 (hxwxd), mm 250x215x300 POA

115-011 Size 8 (hxwxd), mm 220x236x360 POA

* These items are factory fitted and must be specified at the time of ordering the autoclave.

Other options include: NHS Upgrade Package - A number of additional features can be incorporatedinto the autoclave to bring it in line with the specific requirements of

HTM2010. This can be discussed on an individual basis.

Please contact our Technical Office on 01342 826836 for details.

New

Page 6: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

AutoclavesLTE

Take a look at our latest products on www.ecomcat.co.uk 11

115-165Touchclave-Lab “F” Series AutoclavesThe Touchclave-Lab range is provided with a host of features specifically designed to improve throughputand usability. LTE autoclaves are built to BS2646:1993, BS3970 and HTM2010 (optional). All pressurevessels comply with the European PED 97/23/EC and are independently tested to PD5500:2000 Cat 3along with other international standards.

LTE also supplies autoclaves to meet the requirements of many other standards and guidelines, includingHTM2031, EN285, cGMP and EN12347. Contact our Technical Office on 01342 826836 to discuss yourrequirements.

The Touchclave-Lab “F” models have been designed to offer a good level of standard features at a moreaffordable price. In this range, steam is generated within the chamber, therefore water inside thechamber needs to be topped up periodically, either manually or automatically. Low-level water sensorswill prevent the cycle from starting should there be insufficient water. All models are fitted with castorsand will fit through standard doors.

Key features include:

■ Vertical sliding door ■ Air cooling (fans allow operation in areas where water and drainage are not available) ■ Touch-screen multi-program control system ■ Internal data archiving (up to 5000 cycles on an internal flash card) ■ 6-bar built-in silent air compressor ■ Chamber made from 316L grade stainless steel. Complete with 10 year/15,000 cycle warranty■ In-chamber water heating system to generate steam ■ Load-activated sterilising control by means of an Armour-flex Type-T thermocouple ■ Controlled by pressure ensuring excellent accuracy (typically +/-0.5°C) and almost undetectable

overshoot ■ Fitted with pneumatic solenoids and valves for performance and reliability

All “F” models fitted with a vacuum system must be connected to a suitable water supply and drain.

All models incorporate a fully interlocked vertical “easy-glide” sliding door. The door is prevented fromopening unless the safe load temperature has been reached and the pressure has dropped to atmospheric.

Touchclave Touch-screen systemsTouchclave-Lab autoclaves are equipped with a control system which incorpo-rates a powerful PLC combined with an easy to use touch-screen through whichall commands, cycle data, program data and alarms are inputted and displayed.

This versatile system gives users a choice of selecting from a menu of load-specific cycles or developing their own cycle profile. 8 cycles can be storedinto the memory as standard and optional memory expansion is available toincrease the number of available cycles to 20.

Load Specific Cycles - Load-specific cycles are selected by pressing theappropriate cycle title icon and then following the on-screen instructions. Thecycles are pre-programmed to optimise air removal and cooling profiles foreach load type. The only parameters which then require operator input are:sterilising temperature, hold time, safe load temperature, start/stop print andprint intervals. There is also the option to change the cycle title.

Developing Customised Cycles - Instead of a pre-programmed load-specificcycle users can develop a customised cycle profile by touching the “createown cycle” icon which will lead them through a series of easy to followscreens allowing the chosen parameters to be programmed before storingthem in any one of the available cycle number locations.

Once the programs are stored in the memory, starting the cycle could not beeasier. A cycle menu is brought up on screen, allowing the required cycle to beselected. For those who need their cycles to be traceable, there is a facility toinput operator ID and Batch information at this stage. There is also a facility toprogram a delayed cycle start which is particularly useful for maximising theuse of the autoclave. During the cycle, information is constantly displayed onthe touch-screen. Every stage of the cycle carries a different information screen.

A fully integrated thermal paper printer, tractor printer or chart recorder isavailable as an option should a hard copy of the cycle be required.

On completing a successful cycle, the screen will show the “Passed” display.If a fault occurs during the cycle, “Failed” will be displayed on the screen, withdetails of the fault conditions highlighted on a separate screen which can beaccessed by the operator but only acknowledged by those with a supervisoraccess code. All fault conditions will also be printed where applicable.

Touchclave Touch-screen systems incorporate a self-diagnostic system whichwill highlight any abnormality in the cycle. As an option, a modem can befitted to the control system which will allow LTE’s technical team to view real-time cycle data from a remote location, enabling them in many cases to advisequickly on operational issues, thus minimising possible down-time.

Data ArchivingAll models are equipped with electronic data archiving.

Main features of Touchclave data archiving:

■ Cycle data and status are stored within the PLC controller. Dependenton the configuration, up to 5000 cycles may be recorded here. Theinternal storage medium is easily replaced either periodically or whenfull.

■ The recorded cycle data and status include “checksum” data to facilitate data validation.

■ A new cycle cannot be started until the data from the previous cyclehas been recorded.

As an option, cycle data may be downloaded to a remote personal computer,translated and formatted into HTML files and either printed or permanentlyarchived. During each transfer, the integral Touchclave checksum is verified,ensuring that the original data has not been corrupted or modified.

New

Page 7: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukLTE

Autoclaves

12 Take a look at our latest products on www.ecomcat.co.uk

Touchclave-Lab “F” Series Autoclaves (continued)Specifications Model F150 F200 F300Configuration front loading front loading front loadingCapacity, litres 150 200 300Chamber dimensions (hxwxd), mm 600x500x500 600x500x660 600x500x1000Overall dimensions (hxwxd), mm 1815x720x1100 1815x720x1200 1815x720x1350Weight, kg 370 450 720Power, kw 10.5 15 22.5Shelves/Positions 2/4 2/4 2/4*

Cat. No. 115-163 115-164 115-165

Price POA POA POA

* Shelves on these models can be pulled out up to half way and include all necessary safety stops.

Options and AccessoriesAutomatic Water-Fill (“F” models) With high and low level sensors, this system tops up the water level beforeeach cycle and provides additional low level monitoring.

Water Jacket Upgrade (“F” models) Water jackets assist in the cooling process and are ideally suited to liquid cycles.This option replaces the standard cooling fan. Water supply and drain required.

Vacuum/Air BallastThe pre-vacuum stage offers negative/positive pulsing, whilst the post vacuumstage provides a choice of deep drawn or pulsed vacuum plus an optionaldrying cycle.

Air ballast is supplied as part of the package. This feature allows sealed fluidsto be cooled quickly without risk of boiling over or breakage.

Effluent Retention This system returns all liquids back to the chamber for sterilisation before beingexhausted. All non-condensable gases pass through a 0.2 micron microbiologi-cal filter before being discharged. This option can only be ordered in conjunctionwith a vacuum/air ballast system. It is also strongly recommended that anautomatic leak rate cycle be included where Cat. 3 material is being processed.

Automatic Leak-Rate Cycle (Vacuum models) This cycle tests the air tightness of the chamber.

Printer Options Electronic data archiving is standard. However, for those who also want a hardcopy printout after each cycle the following options are available: Thermal Printout - This printer uses thermal paper which has a 15 year shelf life. Tractor Printer - The advantage of this printer is that it can be placed remoteto the autoclave. Chart Recorders - Various types of chart recorders, includingthe latest paperless models can be fitted.

Modem Adding this option provides the facility to connect your autoclave directly intoLTE’s Technical Office, which allows them to interrogate the system and viewreal time cycle data, enabling them to advise on operational issues withoutvisiting site and to minimise on possible down-time.

Volt-Free Contacts This option allows alarm and condition signals from the autoclave to betransmitted to remote monitoring stations, auto-diallers or buildingmanagement systems.

Morrison discard containers SpecificationsModel K150/F150 K200/F200 K300/F300Morrison discard containers/basket size 4 x Size 1 4 x Size 2 6 x Size 2 or 8 x Size 1 or a mixture

Accessories for LTE “F” Series Autoclaves

Cat. No. Description Price

115-172 TC/VAB/F1 Vacuum/Air Ballast System for F150-litre model. Includes automatic water-fill option* POA

115-173 TC/VAB/F2 Vacuum/Air Ballast System for F200-litre model. Includes automatic water-fill option* POA

115-174 TC/VAB/F3 Vacuum/Air Ballast System for F300-litre model. Includes automatic water-fill option* POA

115-178 TC/CON/01 Condensate unit for all Touchclave-Lab “F” models (not required if vacuum option is ordered)* POA

115-179 TC/AWF/01 Automatic water-fill option for all Touchclave-Lab “F” models (not required if vacuum option is ordered)* POA

115-177 TC/JKT/01 Water jacket upgrade for all Touchclave-Lab “F” models* POA

Accessories for LTE “F” and “K” Series Autoclaves

* These items are factory fitted and must be specified at the time of ordering the autoclave.

Cat. No. Description Price

115-176 Automatic leak-rate cycle (vacuum models only)* POA

115-180 Data-printer, thermal paper POA

115-181 Tractor-feed printer (including 10m cable) POA

115-185 Remote data archiving (PC not supplied)* POA

115-186 Modem link* POA

115-187 Volt-free contacts* POA

115-182 Independent 2-pen chart recorder POA

115-183 Independent 3-pen chart recorder POA

115-184 Independent paperless chart recorder POA

115-188 Stainless steel panels - 150-litre models* POA

115-189 Stainless steel panels - 200-litre models* POA

Cat. No. Description Price

115-190 Stainless steel panels - 300-litre models* POA

115-175 Cat 3. effluent retention upgrade* POA

115-194 Basket - Size 1 (hxwxd), mm 230x430x230 POA

115-195 Basket - Size 2 (hxwxd), mm 230x430x315 POA

115-196 Morrison discard container - POASize 1 (hxwxd), mm 230x430x230

115-197 Morrison discard container - POASize 2 (hxwxd), mm 230x430x315

115-191 Loading/carriage trolley - 150-litre models POA

115-192 Loading/carriage trolley - 200-litre models POA

115-193 Loading/carriage trolley - 300-litre models POA

Page 8: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

AutoclavesLTE

Take a look at our latest products on www.ecomcat.co.uk 13

115-170Touchclave-Lab “K” Series AutoclavesThe Touchclave-Lab “K” models are LTE’s top-line range and are designed to operate using either anintegral steam generator situated beneath the chamber or the customer’s own direct steam supply. Allmodels are fitted with castors and will fit through a standard door.

■ Vertical sliding door■ Water jacket cooling system speeds up the cooling stage of the cycle■ Touchscreen multi-program control system (for details, see page 11)■ Internal data archiving (up to 5000 cycles on an internal flash card) ■ Built-in exhaust condensate unit■ Water conservation system■ 6- bar built-in silent air compressor■ Chamber made from 316L grade stainless steel. Fully compliant with the European pressure

equipment directive 97/23/EC. Independently certified to PD5500:2000 Cat. 3. Complete with 10year/15,000 cycle warranty.

■ Load-activated sterilising control by means of an Armour-flex Type-T thermocouple ■ Controlled by pressure ensuring excellent accuracy (typically ±0.5°C) and almost undetectable

overshoot ■ Fitted with pneumatic solenoids and valves for performance and reliability.

All models incorporate a fully interlocked vertical “easy-glide” sliding door. The door is prevented fromopening unless the safe load temperature has been reached and the pressure has dropped to atmospheric.

All “K” models incorporate a water tank, which re-circulates the cooling water until it reaches a pre-settemperature when it is then drained and replaced. This feature significantly reduces water usage duringthe cycle. A re-circulating exhaust condensate unit is fitted on all “K” models, enabling discharge watertemperatures to be kept below 70°C to avoid damage to plastic pipes and the environment. On vacuummodels this feature also serves to protect the vacuum pump from live steam.

Specifications Model K150 K200 K300Configuration front loading front loading front loadingCapacity, litres 150 200 300Chamber dimensions (hxwxd), mm 600x500x500 600x500x660 600x500x1000Overall dimensions (hxwxd), mm 1815x720x1100 1815x720x1200 1815x720x1350Weight, Integral gen./Direct steam, kg 400/360 480/440 750/710Power, Integral gen./Direct steam, kw 15/1.5 15/1.5 30/1.5Shelves/Positions 2/4 2/4 2/4*

Integral generator/Cat. No. 115-166 115-168 115-170

Price POA POA POA

Direct steam/Cat. No. 115-167 115-169 115-171

Price POA POA POA

* Shelves on these models can be pulled out up to half way and include all necessary safety stops.

Options and AccessoriesVacuum/air ballast, effluent retention, automatic leak-rate cycle (vacuum models), printer options,modem, volt-free contacts see page 12 for details.

Steam Jacket Upgrade (“K” models) All “K” models which are fitted with a vacuum/air ballast system can have the jackets upgraded towater/steam jackets.

Constant Standby Steam Generator (“K” models) Non-vacuum models can be fitted with this option which will shorten cycle times. Please enquire for details.

Accessories for LTE “K” Series Autoclaves

Cat. No. Description Price

115-198 TC/VAB/K1 Vacuum/Air Ballast System for K150-litre model* POA

115-199 TC/VAB/K2 Vacuum/Air Ballast System for K200-litre model* POA

115-206 TC/VAB/K3 Vacuum/Air Ballast System for K300-litre model* POA

115-207 Steam jacket upgrade* (K models fitted with vacuum/air ballast option) POA

The remaining accessories are listed on page 12.

* These items are factory fitted and must be specified at the time of ordering the autoclave.

New

Page 9: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukPriorclave

Autoclaves

14 Take a look at our latest products on www.ecomcat.co.uk

AutoclavesPriorclaves are built and tested to exacting standards from the finest quality materials. They have all necessarysafety features such as thermal cooling locks with key override for safe door release temperatures.

Biocote anti-bacterial agent, effective against MRSA, is uniquely added to all epoxy coated surfaces ofall Priorclaves.

Heating and cooling rates are carefully balanced to optimise load heating and productivity. Temperatureand process times are easily set as the TACTROL™2 is a dedicated microprocessor system which allows theoperator greater flexibility in selecting their parameters. A 5 or 10 programme memory option is availablefor the busy laboratory that requires selectable programs to suit a variety of applications at the touch ofa button, but with three levels of security via a separate key-switch.

All Priorclave models are CE marked and independently certified to the European Pressure EquipmentRegulations, EMC and Low Voltage directives. All models are manufactured under an accreditedISO9000: 2000 quality system, are built to the relevant sections of BS2646 and PD5500: 2000 Cat3 andare compliant with BS EN 6 1010-2-041.

A full range of optional accessories is available, and most of these can be retro-fitted should you need toupgrade in the future. Models with vacuum are also available. Please contact our Technical Office on01342 826836 for details. These can assist in the sterilisation of porous materials e.g. gowns, drapesetc., and difficult waste product loads where entrapment of air is a particular problem.

Priorclave strongly recommend full commissioning of autoclaves fitted with vacuum options to achieveoptimum results for customer’s particular load types.

Compact AutoclavesThe Compact 40 bench top and Compact 60 floor standing autoclaves offer the following key features:

SpecificationsModel Compact 40 (Bench top) Compact 60 (Transportable)Loading format Front TopWorking volume, L 39.5 60Internal diameter, mm 350 350Usable depth, mm 420 625External dimensions (wxdxh), mm 520x610x640 472x585x910Weight, kg (approx) 85 95Maximum temperature, °C 138 138Electrical supply 230V, 50Hz, 13A, 3kW 230V, 50Hz, 13A, 3kW

Cat. No. 115-084 115-085

Price POA POA

Models with vacuum are available and have the option of post-cycle vacuum drying. Please contact our TechnicalOffice on 01342 826836 for details.

Options and Accessories

Cat. No. Description Price

115-092 5 Programme memory 1 POA

115-093 Cycle record printer 1 POA

115-095 Load sensed process timing 1 POA

115-103 Stainless steel discard container for Compact 40 POA

115-104 Stainless steel discard container for Compact 60 POA

1. These items should be ordered with the autoclave. Although they can be retro-fitted, a Priorclave engineer will berequired at an extra charge.

Other options and accessories are available. Please contact our Technical Office on 01342 826836, for more details.

■ Unique TACTROL™ 2 microprocessor controlsystem as standard

■ Quickseal Series II door closure as standard ■ Operates from a standard 13 Amp socket■ Fan assisted two-stage cooling as standard■ Automatic timed freesteaming as standard■ Media warming and delayed start facilities

as standard

■ 11x1L Duran bottle or 7x1L conical flaskcapacity (Compact 40)

■ Supplied complete with 2 durable stainlesssteel shelves (Compact 40)

■ Mounted on lockable castors (Compact 60)■ Supplied complete with 2 stainless steel

durable baskets (Compact 60)

115-084

115-085

Control Panel

Page 10: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

AutoclavesPriorclave

Take a look at our latest products on www.ecomcat.co.uk 15

Medium Capacity AutoclavesWith a size and loading format to suit all needs these autoclaves provide an excellent high loadingcapacity to low floor space ratio. Ideal for processing media and waste loads as well as equipment andglassware. Built and tested to exacting standards under an accredited ISO9000:2000 quality system,these autoclaves have all of the necessary safety features such as thermal cooling locks with key overridefor safe door release temperatures. Heating and cooling rates are carefully balanced to optimise loadheating and productivity. A range of optional accessories is available and, due to the modular natureof the autoclave construction, most of these can be retro-fitted should you need to upgrade in thefuture. These models are also available for use with in-house steam supplies.

The medium capacity Priorclave autoclaves offer the following key features:

■ Very low loading heights (top-loading models)■ Tactrol™ 2 microprocessor controller■ Quickseal Series II door closure system fitted as standard■ Automatic timed freesteaming fitted as standard■ Fan assisted two-stage cooling fitted as standard■ Media warming and delayed start facilities as standard■ Grade 316L stainless steel pressure vessel and door guaranteed for 10 years■ High power heating for speed of operation■ Castor mounted for improved mobility

Priorclave strongly recommend full commissioning of autoclaves fitted with vacuum options to achieveoptimum results for the customer’s particular load types. Please call our Technical Office on 01342826836 for details.

SpecificationsModel V100 V150 H100 H150Loading format Top Top Front FrontWorking volume, L 100 150 100 150Internal diameter, mm 500 500 500 500Usable depth, mm 500 740 540 770External dimensions (wxdxh), mm 660x800x850 660x800x1035 735x930x1600 735x1050x1600Loading height, mm 725 935 ———— ————Weight, kg 147 165 190 208Maximum temperature,°C 138 138 138 138Electrical supply Single phase 230V, 30A or 3 phase 400V, 15A per phase (Neutral line required)Baskets/Shelves 2/0 3/0 0/2 0/2

Cat. No. 115-086 115-087 115-088 115-089

Price POA POA POA POA

Models with vacuum are available and have the option of post-cycle vacuum drying. Please contact our TechnicalOffice on 01342 826836 for details.

Options and AccessoriesCat. No. Description Price

115-092 5 Programme memory 1 POA

115-093 Cycle record printer 1 POA

115-095 Load sensed process timing POA

115-276 Automatic water fill system POA

115-098 Stainless steel discard container (Top-loading 100/150) POA

115-099 Stainless steel discard container (Front-loading 100/150) POA

1. These items should be ordered with autoclave. Although they can be retro-fitted, a Priorclave engineer will berequired at an extra charge.

Top-Loading V100 and V150 Priorclaves■ Space saving ■ Supplied complete with 2 (V100) or 3 (V150)

stainless steel baskets ■ Counter balanced lid opening as standard

Front-Loading H100 and H150 Priorclaves■ Easy loading of heavy items■ Supplied complete with 2 non-tipping

stainless steel shelves

115-086

115-089

Page 11: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukPriorclave

Autoclaves

16 Take a look at our latest products on www.ecomcat.co.uk

Rectangular Front Loading Autoclaves Perfect for high volume throughput as well as large bulky items these autoclaves combine a hugeinternal capacity with a small footprint. Models are available for use with in-house steam supplies. Pre-cycle evacuation and fast-cycle drying are also available as options.

The models are equipped with all the features of the other autoclaves in the Priorclave range, plus thefollowing:

Automatic Timed Freesteaming Extends the standard ‘air-purging’ time to ensure thorough removal of air and thus improve temperaturedistribution within the load. Recommended for mixed volume media loads. A drain is required.

Rapid Cooling SystemIncreases the capacity of the autoclave by reducing the cooling time by up to 50%. The effectiveness ofa powerful axial fan is boosted by the unique Priorclave ‘one-pass’ airflow system. With two levels ofselectable operation, cooling is activated automatically either at the end of the process time or as theload temperature reaches 100°C (to reduce media volume loss).

Media Warming Fitted as standard on all autoclaves, this maintains the media overnight at a ‘ready to pour’ temperature- no more early morning starts to melt media.

SpecificationsModel EH230 EH350 EH450 EH700Loading format Front Front Front FrontWorking volume, L 232 348 450 700Internal dimensions (wxdxh), mm 580x600x600 580x900x600 675x900x755 675x1360x755Usable depth, mm 600 900 900 1360External dimensions (wxdxh), mm 760x1020x1635 760x1320x1635 855x1320x1790 855x1780x1790Weight, kg (approx.) 560 640 770 950Maximum temperature, °C 138 138 138 138Electrical supply 400V, 50Hz, 400V, 50Hz, 400V, 50Hz, 400V, 50Hz,

21kW, 30A 21kW, 30A 32.5kW, 45A 42kW, 60A

Cat. No. 115-090 115-091 115-264 115-265

Price POA POA POA POA

Heater power is standard but may be de-rated if supply is limited. All models are available for direct steam supplies.Please contact our Technical Office on 01342 826836 for more details.

Options and Accessories

Cat. No. Description Price

115-092 5 Programme memory 1 POA

115-093 Cycle record printer 1 POA

115-095 Load sensed process timing POA

115-299 Automatic water fill system POA

115-123 Combined pre-cycle vacuum and vacuum cooling (EH230/350) 2 POA

115-266 Combined pre-cycle vacuum and vacuum cooling (EH450/700) 2 POA

115-268 Post-cycle vacuum drying (EH230/350) - includes automatic water-fill and POAair intake filtration 2

115-267 Post-cycle vacuum drying (EH450/700) - includes automatic water-fill and POAair intake filtration 2

115-101 Stainless steel wire mesh basket (EH230/350) POA

115-292 Stainless steel wire mesh basket (EH450/700) POA

115-100 Stainless steel discard container for top loading (EH230/350) POA

115-297 Stainless steel discard container for front loading (EH450/700) POA

1. These items should be ordered with autoclave. Although they can be retro-fitted, a Priorclave engineer will berequired at an extra charge.

2. These options should be ordered at time of manufacture. Vacuum models include the 5 program memory andpulsed freesteaming options and require mains water for vacuum pump operation.

■ Simple two or three bolt door closure■ Tactrol™ 2 microprocessor controller as stan-

dard■ 21kW heating system for shortened cycle times■ Rapid cooling system fitted as standard

■ Media warming and delayed start facilities asstandard

■ 3 stainless steel, non-tipping shelves■ Automatic timed freesteaming as standard

115-265 shown with optional printer

Page 12: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

AutoclavesPriorclaveOptions & Accessories

Take a look at our latest products on www.ecomcat.co.uk 17

TACTROL™ 2 ControllerBecause the Priorclave Tactrol™ 2 microprocessor controller has beenspecially developed for laboratory autoclaves this unique control systemallows unrivalled flexibility, from simple cycles to fully-featured, multi-programme operation with printed records. The digital control panelcontinuously provides information on status and is easy to use. Just setthe temperature and time required, select any options needed andpress ‘start’.

The autoclave process is fully automated, with self-monitoring systemsand pre-set actions for such events as power failure or low water levels,so you can continue with other tasks, secure in the knowledge thatautoclaving is being carried out safely and efficiently.

Control Options5 or 10 Programme MemoryStores up to 5 or 10 pre-programmed cycles, with 3 levels of security

by means of a ‘key-switch’. Thisoption is retro-fittable.

TACTROL™ 2 Process PrinterProduces a comprehensive recordon plain paper for each cycle withthe serial number, programmenumber, date, time, sterilising‘start/ finish’ times and tempera-tures reached. The printer recordsthe chamber temperature unless

Load Temperature Indication or Load Sensed Process Timing is fitted,in which case it prints out the load temperature alongside that of thechamber. Particularly useful for accreditation purposes. This option isretro-fittable.

Automatic Pulsed FreesteamingA solenoid valve periodically opens and closes, causing the chamber torepeatedly pressurise and depressurise, prior to the start of the cycle. Theresulting air-turbulence assists with air removal, improving temperaturedistribution and enhancing steam penetration. Recommended for discardloads. A drain is required. This option is retro-fittable.

Load Sensed Process TimingFor more efficient and precise sterilisation, an armour-coated wanderingprobe inside the Priorclave can be placed in the coolest part of the load.Only when that part of the load has reached the required pre-settemperature, will the process (sterilisation) time begin. Ideal for medialoads, where all bottles are of a similar size. This option is retro-fittable.

Pre-cycle Vacuum and Vacuum CoolingA vacuum pump ensures complete air removal from the load, giving bettertemperature distribution and improved steam penetration. Excellent fordiscard loads when used in conjunction with Pulsed Freesteaming.Vacuum cooling decreases cycle time. The 5 programme memory andpulsed freesteaming options are included as part of this system.

Post-cycle Vacuum Drying Recommended for porous loads such as dressings and labcoats and forsterilising glassware as it enables items to be removed ‘dry’ at the endof the cycle. Post-cycle vacuum drying must be used in conjunction withpre-cycle vacuum and vacuum cooling.

Exhaust FiltrationA high-efficiency microbiological filter removes contaminants from allair and steam leaving the autoclave.

Healthcare AutoclavesAutoclaves within hospital departments may be subject to specialrequirements to comply with the UK Health Service HTM2010 andother local regulations. Priorclave offer a basic HTM2010 compliancepackage including; mechanical cycle counter, setting lock keyswitch,self-monitoring by Tactrol™ 2 system, independent thermal lock andpressure gauge test port. Please contact our Technical Office on 01342826836 for more detailed technical advice.

Extended 2-Year Warranty PackageThe extended warranty package includes installation and a furtherthree preventative maintenance visits at six month intervals over thefollowing 24 months. During this period replacement parts and anyemergency call-outs (with the exception of consumable parts such asinternal wandering thermocouples and work resulting from incorrectuse of the autoclave) will be completely free of charge. Please contactour Technical Office on 01342 826836 for full details.

ServicesDrainageBS2646 Part 2 states that autoclaves used for processing laboratorywaste should always be connected to a drain to prevent contaminatedsteam and condensate from fouling the laboratory. The drain pipeshould be connected to a sealed drain cover and a high level vent pipeshould be fitted discharging outside the laboratory. However, in thecase of loads other than waste, if no suitable drainage point is availablethen an open tundish or other container placed behind the autoclaveunder the outlet pipe should be sufficient. It should be noted that if anyform of freesteaming is required the unit should be connected to adrain to prevent steam being emitted into the laboratory.

Please contact our Technical Office on 01342 826836, for advice on the bestoptions and accessories for your particular requirements. In addition, if you areconcerned about siting, drainage or other services please contact us for freesite surveys and advice.

Control Panel

Page 13: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukCominox

Autoclaves

18 Take a look at our latest products on www.ecomcat.co.uk

115-350

115-350

Sterilclave Benchtop Laboratory AutoclavesThe Sterilclave 24 B and 24 BHD autoclaves are designed and manufactured in compliance with EN13060 and offer superior performance. They feature fractioned pulsed vacuum, suitable for the sterili-sation of solid, hollow (type A and B) and porous loads (fabrics), packed and unpacked. One of the mainfeatures of these units is their ability to sterilise loads at 134°C, thus making them suitable for use inveterinary laboratories and anywhere BSE-infected materials are being manipulated.

Two different types of access key allow programming via the user-friendly control panel. Using the blackkey, it is possible to select the standard sterilisation cycles, while using the white key, the ‘Special’ cyclecan also be selected and the user can program any parameter. The 24 B also features:

■ Double head membrane vacuum pump■ Single handle opening and locking■ Integrated printer (option)■ Very fast cycles due to vacuum■ ‘Special’ cycle programmed by the user, accessible only by using an access key■ Fully compliant with EN 13060■ Two levels of access by key■ Stainless steel chamber (AISI 304) with ten year warranty■ Can be connected to an external PC (option)■ Two year warranty (ten years on pressure chamber)

The 24 BHD, in addition to the features included with the 24 B, also has:

■ Automatic water loading and discharge

The 24 B and 24 BHD have several pre-programmed cycles:

■ 121° C Unwrapped load cycle - 121°C cycle for delicate loads, mainly unwrapped■ 121°C Porous/hollow load cycle - 121°C cycle for solid, porous and delicate hollow loads,

wrapped and unwrapped■ 134°C Prions porous/hollow load cycle - 134°C cycle for solid, porous and hollow loads which

have been in contact with BSE infective agents, wrapped and unwrapped■ 134°C Unwrapped cycle - 134°C cycle for solid loads, mainly unwrapped■ 134°C Porous/hollow cycle - 134°C cycle for solid, porous and hollow loads, wrapped or unwrapped■ 134°C Wrapped cycle - 134°C cycle for solid loads, wrapped or unwrapped■ Bowie & Dick test - steam penetration test■ Vacuum test - hydraulic circuit tightness test

SpecificationsModel 24 B 24 BHDCapacityChamber, litres 23.15 23.15Clean water tank, litres 3.1 3.1Water recovery tank, litres 3.1 3.1

Water consumption per cycle, min/max, ml 420/1040 420/1190Operating pressure, max. kPa 330 330Maximum loadingsUnwrapped solid loads, kg 7.5 7.5Wrapped solid loads, kg 4 4Wrapped and unwrapped hollow loads, kg 3.7 3.7Porous loads, kg 2.2 2.2

DimensionsInternal (chamber) (diaxd), mm 226x425 226x425External (hxwxd), mm 540x445x560 540x445x560Trays (wxd), mm 185x420 185x420Height between trays, mm 50 50

Weight, kg 63 68Electrics 230V, 50Hz 230V, 50Hz

Cat. No. Description Price

115-350 Sterilclave 24 B bench top autoclave POA

115-351 Sterilclave 24 BHD bench top autoclave with automatic water loading and discharge POA

115-352 Printer for Sterilclave 24 B and 24 BHD autoclaves* POA

* This must be specified at time of ordering the autoclave.

Autoclaves are also available in white. For details on other models, options and accessories please contact ourTechnical Office on 01342 826836.

New

New

Page 14: Bench top autoclaves vacuum autoclaves autoclave tapes ...uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/autoclaves.pdf · The New Touchclave-Lab is one of the most significant

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

AutoclavesAccessories

Take a look at our latest products on www.ecomcat.co.uk 19

Decon, Autoclave Deodoriser CapsulesEffectively counteracts the pungent odours from autoclaving equipment soiled with organic matter.

Cat. No. Description Pack Price

208-076 Decon autoclave deodoriser capsules 100 Capsules POA

208-077 Decon autoclave deodoriser capsules 500 Capsules POA

3M, Autoclave and Sterilisation Exposure Tapes3M, Comply Steam Indicator Tape Tape with white diagonal interrupted lines that change to brown/black following exposure to correctsterilisation conditions. Each roll is individually wrapped. Conforms to EN867.

3M, Comply Ethylene Oxide Indicator Tape (formerly Indox) Tape with yellow diagonal interrupted lines that change to red/brown following exposure.

3M, Comply Dry Heat Indicator Tape (formerly Indair) Pale green tape with chevron symbols that change to brown on exposure to dry heat (155°C for 30 mins).

Cat. No. Description Tape width, mm Pack Price

661-047 Comply steam indicator tape 19 55m roll POA

661-048 Comply steam indicator tape 25 55m roll POA

661-049 Comply ethylene oxide gas indicator tape 19 55m roll POA

661-050 Comply dry heat indicator tape 19 55m roll POA

Tape DispensersDesigned for heavy duty service and mounted on non-slip rubber pads.

Cat. No. Description Max. tape width, mm Pack Price

661-008 1 Position tape dispenser 25 1 POA

661-052 2 Position tape dispenser 50 1 POA

661-051 3 Position tape dispenser 75 1 POA

Sterilising BasketsWashing/dipping baskets manufactured in nylon coated wire. Suitable for steam sterilisation up to 120°C.

Cat. No. Description Dimensions, mm Pack Price

190-003 Sterilising/dipping basket 130x130x130 1 POA

190-005 Sterilising/dipping basket 200x200x200 1 POA

Azlon, Sterilising Basket, Polypropylene A sterilising basket with a tapered, stackable design. It has excellent temperature resistance and can beautoclaved to 130°C. Ideal for sterilising laboratory equipment such as test tubes.

Cat. No. Description Dims. (lxwxh), mm Pack Price

190-091 Polypropylene sterilising basket 143x120x109 1 POA

Azlon, Cleaning/Drying Basket, PolypropyleneA strong lightweight, polypropylene basket suitable for use as a draining or autoclave basket as well asfor general use. Units stack when not in use. They have excellent chemical resistance and are auto-clavable to 135°C. Nominal capacity of 10 litres.

Cat. No. Description Dims. (lxwxh), mm Pack Price

190-004 Cleaning/drying basket 400x300x100 1 POA

Nalgene, Autoclaving Basket, PolypropyleneThese baskets with hinged lids are designed for holding labware during autoclaving and washing.Manufactured from polypropylene with a smooth surface that will not scratch plastic or glass.

Cat. No. Description Dims. (lxwxh), mm Pack Price

190-210 Autoclaving basket 154x123x105 1 POA

190-211 Autoclaving basket 178x168x156 1 POA

190-212 Autoclaving basket 239x230x233 1 POA

‘Sterile’ Printed Safety TapeVinyl, adhesive backed safety tape, printed with red ‘Sterile’ on a white background.

Cat. No. Description Tape width, mm Pack Price

661-002 Safety tape with ‘Sterile’ printed in red 12 66m roll POA

208-076

208-077

190-091

661-002

661-050 661-048

661-047 661-049

661-008 661-052

190-005

190-003

STERILE STERILE

190-004 New