BENEfit ®-System. Handbuch
www.psm.ms – premium implants
Prof. Dr. Benedict WilmesDüsseldorf
![Page 2: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/2.jpg)
![Page 3: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/3.jpg)
BENEfi t® Mini Implantat:
Abutments:
Verbindung mit der Apparatur
Schraubendreher:
oder
oder
oder
oder
oder
BENEfit®-System 3
![Page 4: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/4.jpg)
Die BENEfi t®-Abutments
Wilmes B., Drescher D.Benefi t – A mini-implantat system with interchangeale abutments.J Clin Orthod 2008; 42:574-580
Wilmes B., Drescher D., Nienkemper M.Beneplate – A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501
Die BENEplate-Miniplatten
VERÖFFENTLICHUNGEN:
BENEfit®-System4
![Page 5: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/5.jpg)
Der BENEslider
Eine der klassischen Indikationen für eine skelettale Verankerung und insbesondere für Mini-Implantate mit Abutments stellt die Molarendistalisierung/-mesialisierung im Oberkiefer dar. Mittels des so genannten „BENEslider“ können die Molaren körperlich distalisiert werden. Mit Hilfe des Mesialsliders werden Zähne körperlich mesialisiert. So kann in vielen Fällen die Extraktion von bleibenden Zähnen und/oder dentale Implantate vermieden werden.
Zur Verbindung zweier BENEfi t® Mini-Implan tate wird eine BENEplate mit Draht auf die Im plantate geschraubt und die BENEslider Teile (Mobilisator, Federn, BENEtube) auf den Draht aufgesteckt. Die ausführende Kraft wird über eine Feder (240 g oder 500 g) mittels Mobilisator aktiviert.
Anbiegen
intraoral
am Modell
BENEfit®-System 5
![Page 6: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/6.jpg)
33-54704
10-63025
Kabello-ser Akku Schrauben-dreher
Einfaches und sicheres Implantieren durch den Kieferorthopäden
Manueller PSM Drehansatz
Anästhesie, zwei paramediane Depots
Normales Winkelhandstück (blau) mit DIN Anschluss
Vorbohrung, ca. 3 mm tief (nur bei Erwachsenen erforderlich)
Implantatinsertion
+
Der manuelle Dreh an satz wird einfach auf ein handelsübliches Winkelhandstück (blau 1:1) aufgesetzt, welches damit als Winkel schraubendreher verwendet werden kann.
Manueller Drehansatz für Winkelhand stücke
Manueller Drehansatz mod. nach Pauls, mit ein-stellbarem Drehmoment von 0 – 40 Ncm
BENEfit®-System6 Skelettale Verankerung
![Page 7: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/7.jpg)
2.3 x 11 mm2,3 x 11 mm
Dimension bei Verwendung von nur einem Mini-Implantat
BENEfit®-System 7Skelettale Verankerung
![Page 8: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/8.jpg)
Mukosa posterior ca. 1 mm
Mukosa anterior ca. 3 mm
Bevorzugtes Insertionsgebiet Mediane Insertion
Abstand der Mini-Implantate: 7 – 14 mm
Paramediane Insertion
2,0 x 7 mm 2,0 x 9 mm
Ludwig B, Glasl T, Bowman J, Wilmes B, Kinzinger G, Lisson G. Anatomical Guidelines for Miniscrew Insertion: Palatal Sites. J Clin Orthod. 2011:45(8):433-441
VERÖFFENTLICHUNGEN:
Dimension bei Verwendung von zwei Mini-Implantaten
BENEfit®-System8 Skelettale Verankerung
![Page 9: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/9.jpg)
(33-54410)
Abdruckkappe
(33-54425)
Laborimplantat (Analog)
BENEfit®-System 9Herstellung im Labor
![Page 10: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/10.jpg)
Molaren Distalisierung
Molaren Mesialisierung
BENEslider
Mesialslider
Hybrid Hyrax (GNE)
Temporärer Zahnersatz
Pendulum B
T-Bogen
Einordnung retinierter Zähne
Molarenaufrichtung
BENEfit®-System10
Anwendungsbeispiele
![Page 11: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/11.jpg)
(33-54535) (33-54536)
(33-54409)
BENEplate mit 1,1 mm Draht
(33-54540)
Mobilisator
BENEtube
(33-54524) Jugendliche: 240 gr. NiTi Federn
(33-54525) Erwachsene: 500 gr. NiTi Federn
BENEfit®-System 11BENEslider
![Page 12: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/12.jpg)
BENEplate mit 1,1 mm Draht aus nichtrostendem Stahl
Wilmes B, Nienkemper M, Ludwig B, Kau CH, Pauls A, Drescher D. Esthetic Class II Treatment with the Beneslider and Aligners.JCO 2012.46:390-8 Wilmes B, Drescher D., Application and effectiveness of the Beneslider. A device to move molars distally. World J Orthod 2010;11:331–340
5,5 Monate später
VERÖFFENTLICHUNGEN
BENEfit®-System12 BENEslider
![Page 13: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/13.jpg)
Wilmes B, Neuschulz J, Safar M, Braumann B, Drescher D. Protocols for combining the Beneslider with lingual appliances in Class II treatment. J Clin Orthod. 2014;48:744-52
VERÖFFENTLICHUNGEN
BENEfit®-System 13BENEslider
![Page 14: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/14.jpg)
BENEplate mit 0,8mm Stahldraht (33-54428)
oder TMA-Draht (33-54420)
Wilmes B, Katyal V, Drescher D. Mini-implant-borne Pendulum B appliance for maxillary molar distalisation: designand clinical procedure. Aust Orthod J. 2014;30:230-9
VERÖFFENTLICHUNGEN
BENEfit®-System14 Pendulum B
![Page 15: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/15.jpg)
4 Monate später
Behandlungsbeginn
BENEplate mit 0,8mm Stahldraht (33-54428)
oder TMA-Draht (33-54420)
> Gesamte Behandlungszeit: 12 Monate- 6 Monate Pendulum- 6 Monate MB
BENEfit®-System 15Pendulum B
![Page 16: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/16.jpg)
BENEfit®-System16 Front-Verankerung, T-Bogen
![Page 17: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/17.jpg)
Mesialslider mit schiefer Ebene zur simultanen Molarenintrusion
Wilmes B, Katyal K, Willmann J, Stocker B, Drescher D. Mini-implant-anchored Mesialslider for simultaneous mesialisation and intrusion of upper molars in an anterior open bite case: a three-year follow-up. Aust Orthod J 2015;31:87-97
VERÖFFENTLICHUNGEN
BENEfit®-System 17Mesialslider
![Page 18: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/18.jpg)
BENEplate für die Mesialisierung
Wilmes B, Nienkemper M., Drescher D. A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher D. Palatally anchored maxillary molar mesialization using the Mesialslider. J Clin Orthod 2013.47:172-79
VERÖFFENTLICHUNGEN
(33-54541)
Mobilisator mit Haken(33-54539)
Mesialtube
NiTi Federn
BENEfit®-System18 Mesialslider
![Page 19: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/19.jpg)
Wilmes B, Nanda R, Nienkemper M, Ludwig B, Drescher D. Correction of upper-arch asymmetries using the Mesial-Distalslider. J Clin Orthod. 2013 ;47:648-55
VERÖFFENTLICHUNGEN:
BENEfit®-System 19Mesial-Distal-Slider
![Page 20: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/20.jpg)
33-54450 33-54452
Nienkemper M,·Wilmes B,·Pauls A, Drescher D. Preprosthetic molar uprighting using skeletal anchorage. J Clin Orthod 2013, 47:433-7
VERÖFFENTLICHUNGEN:
BENEfit®-System20 Molarenaufrichtung
![Page 21: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/21.jpg)
(33-54430)
Standard Abutment
(33-54466)
Peek Abutment
oder
Wilmes B, Nienkemper M, Renger S, Drescher D. Mini-implant-supported temporary pontics. J Clin Orthod. 2014;48:422-9
VERÖFFENTLICHUNGEN:
BENEfit®-System 21Temporärer Zahnersatz
![Page 22: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/22.jpg)
(33-54466)
BENEfi t Peek Abutment, inkl. 1 Fixationsschraube
BENEfit®-System22 Fallbeispiel
![Page 23: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/23.jpg)
Brückentechnik
BENEfit®-System 23Behandlung großer Lücken
![Page 24: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/24.jpg)
Nienkemper M, Wilmes B, Ludwig B, Lübberink G, Drescher D. Extrusion of impacted teeth using mini-implant-borne mechanics. J Clin Orthod.2012;46: 150-155
VERÖFFENTLICHUNG:
Abutment mit Brackets TMA-Draht 16/22”
BENEfit®-System24 Retinierte Zähne
![Page 25: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/25.jpg)
Wilmes B, Nienkemper M, Ludwig B, Nanda R, Drescher D. Upper-Molar Intrusion Using Anterior Palatal Anchorageand the Mousetrap Appliance. J Clin Orthod 2013.47:314-20
VERÖFFENTLICHUNG:
TPA
Intrusive force
(95-13012)
Mausefalle
Intrusionskraft
TPA
BENEfit®-System 25Molaren-Intrusion
![Page 26: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/26.jpg)
Wilmes B., Drescher D., Vertical Periodontal Ligament Distraction – a New Method for Aligning Ankylosed and displaced Canines. J Orofac Orthop. 2009; 70:213-223
VERÖFFENTLICHUNG:
BENEfit®-System26 Parodontale Distraktion ankylosierter Zähne
![Page 27: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/27.jpg)
Wilmes B, Fields of Application of Mini-Implants. In: Ludwig, Baumgaertel, Bowman: Mini-Implants in orthodontics. Innovative anchorage concepts. London, Berlin etc. Quintessence. 2008: 91- 122Wilmes B, Nienkemper M, Drescher D. Application and effectiveness of a new miniimplant and tooth-borne rapid palatal expansion device. World J Orthod. 2010Nienkemper M, Wilmes B, Franchi L, Drescher D. Effectiveness of maxillary protraction using a hybrid hyrax-facemask combination: A controlled clinical study. Angle Orthod. 2014
2x
2x
VERÖFFENTLICHUNG:
(33-54430)
BENEfi t 2.0 Schraube9 mm
2x
(33-54462)
oder
BENEfit®-System 27Hybrid-Hyrax
![Page 28: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/28.jpg)
Craniale Kraftapplikation
Ziel 1: Weniger Kippung der Zähne
Ludwig B, Baumgaertel S, Kinzinger G, Zorkun B, Glasl B, Wilmes B. Application of a new visco-elastic FEM-Model and analysis of miniscrew supported Hybrid-Hyrax treatment. Am J Orthod Dentofacial Orthop 2013
VERÖFFENTLICHUNG:
BENEfit®-System28 Hybrid-Hyrax
![Page 29: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/29.jpg)
Ludwig B, Glasl B, Bowman J, Drescher D, Wilmes B. Miniscrew supported Class III Treatment with the Hybrid RPE Advancer. J Clin Orthod 2010; 44:533-539Nienkemper M, Wilmes B, Pauls A, Drescher D. Maxillary protraction using a hybrid hyrax - face-mask combination. Prog Orthod 2013;14:5
VERÖFFENTLICHUNGEN:
Wilmes B, Kau CH, Ludwig B, Drescher D. Early Class III Treatment with a Hybrid Hyrax-Mentoplate Combination J Clin Orthod, 45:1-7
Intraorale Alternative
VERÖFFENTLICHUNGEN:
Ziel 2: Vermeidung mesialer Zahnaufwanderungen, die durch die Gesichtsmaske verursacht werden können.
BENEfit®-System 29Hybrid Hyrax
![Page 30: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/30.jpg)
BENEfit®-System30 Hybrid-Hyrax
![Page 31: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/31.jpg)
BENEfit®-System 31Hybrid-Hyrax / Gesichtsmaske
![Page 32: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/32.jpg)
Wilmes B, Nienkemper M, Drescher D. Application and effectiveness of a new mini-implant and tooth-borne rapid palatal expansion device. World J Orthod. 2010
Weniger Kippung
Keine Molarenaufwanderung
VERÖFFENTLICHUNGEN:
BENEfit®-System32 Hybrid-Hyrax / Gesichtsmaske
![Page 33: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/33.jpg)
Abmessung (d x Länge)
2.0
33-820-04 2,0 x 4 mm33-820-05 2,0 x 5 mm33-820-07 2,0 x 7 mm
TX Bone Schraube 2,0 mm
d
Länge
7 mm
9 mm
11 mm
30 m
m
(33-850-11) (33-850-10)
(33-850-16)
(33-850-50)
(33-850-18)
(33-850-30)
(33-850-41) (33-850-20)(33-850-40)
BENEfit®-System 33MentoPlate
![Page 34: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/34.jpg)
Gesichtsmaske nicht mehr notwendig
Vorteile:– die Mentoplate kann bereits vor Durchbruch der Eckzähne ab einem Alter von 8 Jahren eingesetzt werden– Öffnung der Gaumennaht (RPE Effekt)– Geringes Risiko einer Wurzelverletzung
Wilmes B, Nienkemper M, Ludwig B, Kau CH, Drescher D. Early Class III Treatment with a Hybrid Hyrax-Mentoplate Combination. J Clin Orthod 2011; 45:1-7
VERÖFFENTLICHUNGEN:
BENEfit®-System34 Hybrid-Hyrax und MentoPlate
![Page 35: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/35.jpg)
ybridhyraxHybrid-Hyrax
MentoPlate
Wilmes B, Nienkemper M, Ludwig B, Kau CH, Drescher D. Early Class III Treatment with a Hybrid Hyrax-Mentoplate Combination. J Clin Orthod 2011; 45:1-7
VERÖFFENTLICHUNGEN:
BENEfit®-System 35Hybrid-Hyrax und MentoPlate
![Page 36: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/36.jpg)
5 Monate später
BENEfit®-System36 Hybrid-Hyrax und MentoPlate
![Page 37: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/37.jpg)
BENEfit®-System 37Hybrid-Hyrax und MentoPlate
![Page 38: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/38.jpg)
Vorher
Nachher
Wilmes B, Ludwig B, Katyal V, Nienkemper M, Rein A, Drescher D. The Hybrid Hyrax Distalizer, a new all-in-one appliance for rapid palatal expansion, early class III treatment and upper molar distalization. J Orthod. 2014;41:47-53
VERÖFFENTLICHUNGEN:
BENEfit®-System38 Hybrid Hyrax Distalizer
![Page 39: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/39.jpg)
Benefi t-System„A Breakthrough in Miniscrew Stability“
Robert G. Keim, Editor JCOThe Editor‘s Corner J Clin Orthod 2009.43;485-386
Keim: The Editor‘s CornerA Breakthrough in Miniscrew Stability
As with all other practical innovations in orthodontics, temporary anchorage devices (TADs) have involved a signifi cant learning curve. Although Creekmore and Eklund‘s se-minal paper on skeletal anchorage appeared in JCO more than 25 years ago,1 it remained on the fringes of the profession until around the turn of the century, when the concept took off like a rocket. Since then, paper after paper has illustrated successful treatment of most categories of malocclusion... [more]Access to the Editor‘s Corner ar free. For more free articles click here
August 2009 corner: This month‘s cover features a 30 volume rendering of a CT scan using software from Anatomage, Icc, as described in The Cutting Edge.
www.uniklinik-duesseldorf.de/kieferorthopaedie
-> Weniger Probleme
-> Sichere Mechanik
BENEfit®-System 39
![Page 40: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/40.jpg)
33-54524 240 g33-54525 500 g
BENEslider NiTi Federn, 2 Stk.
33-54536
BENEtube, lang, 2. Stk.
6,5
mm
33-54535
BENEtube, Standard für Lingualtechnik, 2. Stk.
4,5
mm
33-54535 33-54535
33-54524 33-54524
33-54540 33-54540
33-54409
33-54430
BENEfi t® Abutment Standard
33-54460 1.1 rostfreies Stahl
Abutment Standard mit 1,1 mm Draht (12 cm)
33-54425
BENEfi t® Labor/Manipulierimplantat
33-54450 Abutment mit Bracket33-54452 Abutment mit Bracket
BENEfi t® Abutment mit Brackets
33-54410
BENEfi t® Abdruckkappen
33-54543
Micro Mobilisator für 0,5 – 1,2 mm DrahtDas komplette BENEfi t-Sortiment fi nden Sie
in unserem Produktfl yer BENEfi t KAT-002.
33-54599 BENEslider Komplettset 240 gr. bestehend aus:
33-54409
33-5454033-5452433-54535
BENEplate kurz, mit 1,1 mm Draht, inkl. FixierschraubenMobilisator für 0,5 – 1,2 mm DrahtBENEslider Federn, 240 gr.BENEtube, für die Lingualtechnik
33-54597 wie 33-54599 aber mit 500 gr. Federn
steril
2.3
33-54307 2,3 x 7 mm33-54309 2,3 x 9 mm33-54311 2,3 x 11 mm33-54313 2,3 x 13 mm33-54315 2,3 x 15 mm
BENEfi t® KFO-Schraube 2,3 mm, Material Titan
steril
2.0
33-54207 2,0 x 7 mm33-54209 2,0 x 9 mm33-54211 2,0 x 11 mm33-54213 2,0 x 13 mm33-54215 2,0 x 15 mm
BENEfi t® KFO-Schraube 2,0 mm, Material Titan
BEN
Eslid
er
33-54541
Mobilisator mit Haken
33-54544
BENEtube nach Dr. Banach, mit Draht 1,1 mm, 40 mm, 2. Stk.
33-54540
Mobilisator für 0,5 – 1,2 mm Draht
33-54539
Mesialtube, mit Haken
6,5
mm
33-54463
BENEfi t® Hyrax Abutment
NEW !
33-54445
Abutment mit Öse nach Dr. S. Renger, St. Louis, Frankreich
NEW !
NEW !
73-31960 QBquattro® / BENEfi t® Sterilisierbehälter für Implantate und Instrumente, leer
33-54100 QBquattro® / BENEfi t® Instrumenten Set
NEW !
NEW !
BENEfit®-System Produktübersicht40
![Page 41: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/41.jpg)
33-54400 rostfreies Stahl
BENEplate, lang, inkl. Fixierschrauben
33-54402 rostfreies Stahl
BENEplate, kurz, inkl. Fixierschrauben
1:1
33-54409 1,1 rostfreies Stahl
BENEplate, kurz, mit 1,1 mm Draht (12 cm), inkl. Fixierschrauben
1:1
33-54408 0,8 rostfreies Stahl
BENEplate, kurz, mit 0,8 mm Stahldraht (12 cm), inkl. Fixierschrauben
1:1
33-54420 0,8 TMA
BENEplate, kurz, mit 0,8 mm TMA-Draht (12 cm), inkl. Fixierschrauben
1:1
1:1
33-54428 0,8 rostfreies Stahl
BENEplate, lang, mit 0,8 mm Draht (12 cm), inkl. Fixierschrauben
1:1
33-54429 1,1 rostfreies Stahl
BENEplate, lang, mit 1,1 mm Draht (12 cm), inkl. Fixierschrauben
1:1
120 mm
1:1
33-54407
BENEplate lang, mit Bracket inkl. Fixierschrauben
1:1
33-54403
Ersatz Fixierschrauben, 2 Stk.
12,5 mm17,5 mm
10-67513 QB DENTAL
Bohrer, 1,4 x 33 mm AT 15 mm, rot für 2,0 mm Schrauben
für 2,0 mm Schrauben
11-18452 QB DENTAL
Bohrer, 1,8 x 33 mm AT 15 mm, grau für 2,3 mm Schrauben
für 2,3 mm Schrauben
33-54704 QBManueller Drehansatz mod. nach Pauls, mit einstellbarem Drehmoment von 0 – 40 Ncm
10-63025 QBManueller Drehansatz für Winkelhand stücke
33-55000
BENEfi t® Starter Instrument Kit Set
73-31990
BENEfi t® Starter Behälter, leer
33-54462
Hyrax Ring, inkl. Fixa-tionsschrauben, 2 Stk.
33-54466
BENEfi t Peek Abutment, inkl. 1 Fixationsschraube
33-54533
FlexiTube, 2 Stk.
NEW !
NEW !
33-18266 QBHandgriff für Instrumente mit Dental-ansatz mit begrenztem Drehmoment (10 Ncm)
NEW !
BENEfit®-System 41Produktübersicht
![Page 42: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/42.jpg)
95-13001
Modell BENEslider, mesial., distal.
95-13003
Modell Pendulum B
95-13005
Modell Molarenaufrichtung
95-13007
Modell Frontverankerung
95-13009
Modell „Temporäres Implantat“
95-13002
Modell Molarenverankerung
95-13006
Modell Hybridhyrax
95-13008
Modell Zahnretention
95-13011
Gipsmodell mit Laborimplantaten
NEW !NEW !
95-13014
Modell T-Mesial/Distalslider
95-13012
Modell Mausefalle
95-13013
Modell Hybridhyrax Distalizer
95-13015
Modell Hybridhyrax Distalizer 2
V-90-994-02
BENEfi t® Modellkoffer für 18 Modelle, leer
V-90-994-00
BENEfi t® Modellkoffer für 9 Modelle, leer
BENEfit®-System Produktübersicht42
![Page 43: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/43.jpg)
BENEfit®-System 43ProduktübersichtNotes
![Page 44: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher](https://reader033.vdocument.in/reader033/viewer/2022060606/605b279c18e0df68ce35304e/html5/thumbnails/44.jpg)
BENEfit ®-System. Handbuch
Mehr Informationen unter: www.psm.ms
Hersteller:
psm MEDICAL SOLUTIONS
Moltkestraße 4178532 Tuttlingen
Telefon +49 ( 74 61) 9 66 37-0Fax +49 ( 74 61) 9 66 37-29
E-Mail [email protected] www.psm.ms
Vertrieb in der USA:
psm North America
P.O. Box 14249950 Jefferson Street
Suite 130, Indio, CA 92201
Toll-free: 800-733-1622
E-Mail [email protected] www.psm-na.us
www.psm.ms – premium implants
Verkauf in D, A, CH:
DENTALLINE GmbH & Co. KG
Goethestraße 4775217 Birkenfeld
Telefon +49 7231 97810
E-Mail [email protected] www.dentalline.de
KAT
-012
| 0
9.15
| Re
v. 1
F
RIC
ON
.de