beyond led technology...surge-protective device provided or not; “c” can be “r” or blank for...

22
Report No.: BLC1907022E-A Laboratory: Belling Test Laboratory Co., LTD A2LA Certificate# 4810.01 Unit 401, No. 309 Xinxin Seven Road, Zengcheng District, Guangzhou, Peoples Republic of China. Website: http://www.bltst.com Report Format Number BL-FM-SA-012 1 / 22 LM-79-08 Test Report For Beyond LED Technology Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model name(s): AST-SWP01-55BA2-abcdf Remark: “a” can be any two letters to represent lamp colors; “b” can be “S” or blank for Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided or not; “f” can be any two digits to represent CCT. Representative (Tested) Model: AST-SWP01-55BA2-abcd40 AST-SWP01-55BA2-abcd57 Model Different: All construction and rating are the same, except CCT Test & Report By: Review By: S h e r r y Y a n g Jason Luo Engineer: Sherry Yang Manager: Jason Luo Date: July 18, 2019

Upload: others

Post on 22-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LA Certificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

1 / 22

LM-79-08 Test ReportFor

Beyond LED Technology

Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted

Area Luminaires

Model name(s): AST-SWP01-55BA2-abcdfRemark: “a” can be any two letters to represent lamp colors; “b” can be “S” or blank for

Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided ornot; “d” can be “P” or blank for Photocontrol provided or not; “f” can be any two digits to

represent CCT.

Representative (Tested) Model: AST-SWP01-55BA2-abcd40AST-SWP01-55BA2-abcd57

Model Different: All construction and rating are the same, except CCT

Test & Report By: Review By:

Sherry Yang Jason LuoEngineer: Sherry Yang Manager: Jason LuoDate: July 18, 2019

Page 2: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

2 / 22

1.1 Product Information:Organization Name ASMART LIGHT CO., LTDBrand Name ASMARTModel Number AST-SWP01-55BA2-abcdfSKU (if available) N/AType of Luminaire(for integral lamps, list base type and lamp type)

Outdoor Non-Cutoff and Semi-CutoffWall-Mounted Area Luminaires

Rated Voltage / Frequency 100-277Vac, 50/60 HzNominal Power 55WRated Initial Lamp Lumen --Declared CCT 4000K,4500K,5000K,5700KLED Manufacturer Lumileds Holding B.V.LED Model L128-4080RA35000P1Sample Number BLC1907022E-A1(4000K),A2(5700K)Luminaire Aperture (for downlights) -- in.Luminaire Length -- mmLuminaires Width -- mmNumber of Units (modular products) N/A s

Photo

Page 3: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

3 / 22

1.2 Test Specifications:Date of Receipt July 15, 2019Date of Test July 16, 2019

Test item

1. Total Luminous Flux2. Luminous Distribution Intensity3. Luminous Efficacy4. Correlated Color Temperature5. Color Rendering Index6. Chromaticity Coordinate7. Electrical Parameters

Reference Standard

1. IES LM-79-2008 Electrical and Photometric Measurements ofSolid-State Lighting Products

2. ANSI C78.377-2015 Specifications for the Chromaticity of SolidState Lighting Products

3. CIE 13.3-1995 Method of Measuring and Specifying ColourRendering Properties of Light Sources

4. CIE 15-2004 Technical Report Colorimetry5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source6. IESNATM-16-05 Technical Memorandum on Light Emitting

Diode (LED) Sources and SystemsReference Work Instruction BL-QP-033

1.3 Test Methods1) Photometric and Light Distribution Measurement – Goniophotometer Method:Photometric parameters were measured using the goniophotometer and software. The ambienttemperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from thesample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz.It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen werecalculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.2) Chromaticity Measurement – Sphere-Spectroradiometer Method:Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software.The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The samplemeasurements were made using a spectroradiometer connected by a fiber optic cable and detectorthrough the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC,60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated colortemperature and color rendering index were calculated from the spectral power distribution taken at 5nm intervals over the range of 380 to 780 nm.3) Electrical Measurements:Electrical parameters were measured using power meters incorporated in goniophotometer orsphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at25º C ± 1º C. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized beforemeasurement was made. Voltage, frequency, current, power, power factor and total harmonic distortionwere measured by and read from the power meter.

Page 4: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

4 / 22

2.1 Electrical, Photometric and Chromaticity Measurements(Refer to Work Instruction BL-QP-033)

Test date 2019-07-16 Test Ambient: 25.2 º C

Test Orientation As intended Stabilization Time (min) 90

Model Number AST-SWP01-55BA2-abcd40

Electrical Measurement:Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD%

BLC1907022E-A1

120.0 60 0.4591 54.38 0.987 14.37

277.0 60 0.2194 55.19 0.908 12.94

DLC Pass Criteria >= 0.9(-3%) <= 20(+5)

Chromaticity Measurement - Sphere-Spectroradiometer Method:Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 82 R9 9

Frequency (Hz) 60 R2 91 R10 78

CCT (K) 4058 R3 96 R11 80

Duv 0.00103 R4 81 R12 62

Chromaticity (x, y) x=0.3786 y=0.3778 R5 82 R13 84

Chromaticity (u’, v’) u(u')=0.2235 v'=0.5018 R6 87 R14 98Color Rendering Index (CRI) 83.5 R7 85 R15 76

R9 9 R8 64 -- --

Photometric Measurement – Goniophotometer Method:Parameter Result DLC V4.4 Pass Criteria

Test Voltage (V) 120.0 277.0--

Frequency (Hz) 60 60

Total Luminous (lm) 7033.9 7065.35000-10000 (-10%)

0-90° Luminous (lm) 6567.5 6597.5

Luminous Efficacy (lm/W) 129.35 128.02

Premium: >= 115(-3%)0-90° Luminous Efficacy (lm/W) 120.77 119.54

Most worst Luminous/Highest 127.45

Zonal lumens in the 80-90° zone (%)80-90°/0-90°

6.67--

<=10(+3)

BeamAngle (°) 104.5 -- --

Center Beam Candle Power (cd) 2082 -- --

Page 5: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

5 / 22

Spectral Power Distribution & Chromaticity Diagram

Page 6: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

6 / 22

TM30

Page 7: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

7 / 22

Page 8: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

8 / 22

Zonal Lumen Tabulation

Zonal Lumen Summary

Zone Lumens % Lamp % Luminaire

0-30 1,571.9 22.3% 22.3%

0-40 2,550.3 36.3% 36.3%

0-60 4,591.6 65.3% 65.3%

60-90 1,975.9 28.1% 28.1%

70-100 1,348.4 19.2% 19.2%

90-120 415.5 5.9% 5.9%

0-90 6,567.5 93.4% 93.4%

90-180 466.1 6.6% 6.6%

0-180 7,033.6 100% 100%

Lumens Per Zone

Zone Lumens % Total Zone Lumens % Total

0-10 194.9 2.8% 90-100 242.4 3.4%

10-20 555.2 7.9% 100-110 114.9 1.6%

20-30 821.7 11.7% 110-120 58.3 0.8%

30-40 978.5 13.9% 120-130 29.3 0.4%

40-50 1,040.9 14.8% 130-140 12.4 0.2%

50-60 1,000.3 14.2% 140-150 4.2 0.1%

60-70 869.9 12.4% 150-160 2.5 0%

70-80 667.9 9.5% 160-170 1.7 0%

80-90 438.1 6.2% 170-180 0.6 0%

Page 9: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

9 / 22

Photometric Data

Page 10: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

10 / 22

Candela Table - Type C

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 2082 2082 2082 2082 2082 2082 2082 2082 2082 2082 2082 2082 2082 2082 2082 2082 2082

1 2116 2114 2124 2113 2087 2040 2044 2055 2044 2040 2016 2026 2079 2131 2153 2145 2116

2 2078 2079 2072 2078 2082 2023 2041 2042 2053 2025 2022 1998 2065 2133 2096 2085 2078

3 2045 2059 2056 2055 2094 2038 2063 2135 2064 2111 2040 2023 2062 2103 2095 2076 2045

4 2083 2085 2032 2054 2101 2040 2121 2021 2039 2005 2086 2017 2058 2094 2082 2076 2083

5 2113 2112 2067 2041 2090 2023 2008 2015 1905 1987 1996 2008 2041 2077 2071 2124 2113

6 2144 2155 2098 2026 2088 2041 2064 1888 2038 1900 2064 2040 2016 2064 2111 2152 2144

7 2029 2066 2117 1989 2080 2065 1954 2162 2175 2169 1890 2017 1999 2038 2121 2121 2029

8 2019 2019 2115 1980 2083 2012 1885 2159 2014 2137 1963 1943 1999 2007 2135 2041 2019

9 2058 2038 2013 2011 2098 1955 2083 1936 1845 1902 2111 1954 1996 1989 2115 2042 2058

10 2127 2093 2013 2049 2086 1954 2119 1872 1945 1889 2084 1993 1993 1991 2047 2074 2127

11 2107 2138 1981 2036 2083 1984 2057 1957 1976 1950 1963 1943 1982 2007 2034 2137 2107

12 2060 2075 2017 2005 2068 1969 1897 1991 1986 2000 1830 1830 1982 2017 2011 2112 2060

13 2092 2058 2053 2002 2040 1879 1833 2008 1934 1962 1856 1845 1972 2004 2035 2058 2092

14 2064 2077 2025 2031 2009 1807 1866 1950 1883 1920 1889 1941 1959 1982 2031 2074 2064

15 2074 2053 1980 2034 1987 1847 1891 1886 1824 1854 1902 1990 1940 1991 2006 2070 2074

16 2165 2106 1976 1984 1974 1933 1910 1815 1721 1801 1915 1974 1905 2007 1992 2108 2165

17 2251 2147 2006 1938 1961 1958 1907 1752 1765 1720 1871 1913 1876 2018 1993 2120 2251

18 2319 2207 2052 1885 1942 1952 1860 1698 1654 1737 1821 1865 1857 2009 2033 2143 2319

19 2303 2290 2069 1834 1932 1911 1817 1704 1654 1677 1754 1809 1842 1994 2064 2221 2303

20 2156 2297 2004 1796 1909 1873 1752 1641 1689 1620 1685 1765 1820 1920 2036 2292 2156

21 2259 2171 1985 1771 1877 1829 1684 1652 1560 1641 1663 1731 1789 1831 1996 2250 2259

22 2465 2215 1981 1755 1843 1761 1659 1640 1475 1576 1611 1717 1778 1764 1980 2177 2465

23 2369 2345 2003 1749 1811 1717 1591 1536 1505 1462 1572 1698 1785 1723 1945 2253 2369

24 2195 2333 2058 1744 1769 1690 1558 1456 1500 1476 1529 1693 1772 1712 1928 2282 2195

25 2253 2246 2117 1750 1733 1670 1519 1459 1360 1456 1501 1693 1726 1707 1957 2268 2253

26 2308 2215 2143 1750 1694 1658 1482 1432 1245 1421 1479 1665 1688 1706 2028 2243 2308

27 2504 2250 2065 1723 1687 1632 1468 1391 1441 1265 1438 1610 1645 1701 2106 2239 2504

28 2548 2329 1981 1701 1672 1626 1434 1202 1140 1214 1372 1577 1609 1691 2087 2260 2548

Page 11: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

11 / 22

29 2476 2470 1934 1691 1643 1626 1385 1255 1236 1324 1303 1518 1575 1655 2009 2318 2476

30 2451 2514 1927 1694 1631 1612 1304 1245 1115 1084 1291 1461 1536 1598 1941 2440 2451

31 2529 2394 1970 1705 1602 1571 1253 1071 1130 1175 1255 1424 1502 1563 1889 2455 2529

32 2452 2310 2047 1684 1605 1526 1235 1163 1026 1041 1208 1398 1496 1539 1872 2356 2452

33 2421 2346 2095 1688 1590 1481 1201 1022 974 1049 1161 1370 1513 1522 1924 2289 2421

34 2426 2356 2127 1672 1587 1404 1175 1027 923 962 1083 1343 1505 1539 1981 2291 2426

35 2395 2398 2100 1665 1573 1354 1125 943 875 917 1102 1324 1489 1570 2038 2327 2395

36 2452 2370 2028 1648 1572 1310 1036 893 792 852 1037 1308 1454 1588 2021 2355 2452

37 2566 2329 1947 1601 1584 1278 1052 826 769 819 944 1291 1428 1635 2019 2341 2566

38 2453 2308 1902 1548 1587 1249 1023 791 714 758 958 1215 1412 1686 2000 2299 2453

39 2384 2347 1930 1511 1559 1240 929 747 649 706 909 1195 1403 1688 1926 2260 2384

40 2378 2338 1970 1490 1556 1194 911 683 595 677 872 1148 1394 1628 1852 2267 2378

41 2373 2384 1988 1497 1503 1185 885 653 554 618 841 1109 1386 1549 1859 2258 2373

42 2469 2360 1952 1516 1472 1167 837 604 545 574 792 1059 1375 1509 1853 2354 2469

43 2624 2363 1942 1551 1438 1145 814 562 523 532 759 1040 1368 1468 1798 2350 2624

44 2539 2386 1950 1673 1405 1098 771 530 489 496 723 1010 1334 1424 1786 2339 2539

45 2493 2389 1906 1805 1400 1064 737 492 454 474 694 995 1300 1419 1793 2325 2493

46 2446 2361 1886 1744 1378 1023 701 465 425 455 659 958 1256 1446 1849 2295 2446

47 2393 2400 1880 1581 1349 979 674 443 407 434 611 922 1225 1476 1910 2273 2393

48 2387 2380 1859 1484 1333 952 643 425 389 409 571 881 1220 1489 1941 2294 2387

49 2350 2291 1814 1424 1293 929 607 405 372 380 539 844 1192 1539 1891 2274 2350

50 2385 2238 1843 1380 1267 886 571 381 350 361 501 816 1177 1632 1783 2254 2385

51 2333 2262 1883 1383 1232 863 528 358 327 334 479 786 1154 1570 1734 2198 2333

52 2189 2216 1930 1407 1237 830 499 339 308 320 446 745 1153 1420 1710 2207 2189

53 2137 2178 1903 1477 1195 786 463 317 289 310 436 706 1111 1344 1749 2142 2137

54 2162 2062 1788 1547 1177 749 435 302 276 295 406 676 1097 1329 1809 2078 2162

55 2226 2029 1677 1576 1169 733 408 289 264 277 369 645 1077 1326 1856 1986 2226

56 2298 2060 1648 1448 1113 701 385 274 248 260 347 610 1062 1318 1625 1978 2298

57 2239 2137 1641 1350 1118 656 363 258 231 244 326 570 1042 1326 1549 2030 2239

58 2183 2118 1666 1325 1070 621 340 242 219 229 299 527 1015 1344 1513 2069 2183

59 2107 2057 1820 1323 1058 606 316 228 210 218 278 502 990 1355 1513 2020 2107

60 2075 1991 1695 1307 1036 555 294 215 201 207 265 465 967 1295 1566 1954 2075

Page 12: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

12 / 22

61 2083 1943 1585 1343 1010 532 270 204 194 194 249 438 939 1235 1718 1886 2083

62 2028 1924 1553 1339 972 495 254 193 187 185 236 409 903 1221 1520 1864 2028

63 1949 1899 1510 1251 950 460 239 183 176 175 223 377 878 1176 1448 1848 1949

64 1954 1839 1465 1199 934 426 226 174 168 165 210 352 844 1151 1395 1815 1954

65 1948 1808 1407 1195 899 394 215 162 158 156 199 325 817 1141 1354 1775 1948

66 1962 1800 1376 1212 872 366 205 154 146 147 189 304 760 1130 1331 1739 1962

67 1879 1802 1349 1203 854 337 195 146 134 139 179 282 726 1102 1293 1729 1879

68 1766 1739 1331 1133 808 316 185 137 123 130 170 263 692 1060 1260 1700 1766

69 1796 1660 1315 1084 765 293 176 128 115 122 160 246 634 1035 1245 1632 1796

70 1819 1663 1268 1057 719 270 168 120 107 113 150 235 590 1012 1227 1607 1819

71 1747 1645 1222 1059 667 251 156 113 98 103 142 224 541 962 1192 1610 1747

72 1786 1598 1184 998 621 236 147 105 90 94 131 213 494 947 1148 1571 1786

73 1910 1609 1179 958 560 225 136 96 85 86 122 203 438 917 1112 1550 1910

74 1788 1636 1151 930 514 214 127 87 79 78 115 191 390 879 1104 1563 1788

75 1487 1528 1130 890 460 204 118 79 73 73 106 182 348 821 1085 1524 1487

76 1391 1386 1120 859 410 195 110 72 68 66 98 172 300 786 1059 1374 1391

77 1472 1308 1081 831 357 184 101 65 62 60 90 164 267 764 1038 1274 1472

78 1475 1294 1007 783 315 173 94 58 58 53 83 154 234 717 970 1253 1475

79 1471 1288 968 749 278 164 86 52 52 48 77 144 212 687 917 1251 1471

80 1507 1289 948 725 248 155 80 46 47 43 71 135 190 642 888 1228 1507

81 1419 1268 929 668 217 145 73 40 42 37 64 127 173 604 878 1219 1419

82 1326 1202 906 632 194 136 68 35 37 32 58 119 159 554 853 1172 1326

83 1265 1141 882 608 174 128 62 30 32 27 52 112 146 512 836 1099 1265

84 1235 1083 845 574 156 120 56 25 27 22 46 103 135 480 804 1046 1235

85 1187 1035 812 535 142 112 51 20 22 17 40 96 126 444 759 1006 1187

86 1119 998 763 505 126 105 45 14 17 13 34 89 120 408 717 969 1119

87 1071 943 721 466 115 98 39 9 11 8 29 85 114 374 686 921 1071

88 998 896 689 427 106 91 34 3 4 3 24 79 108 337 649 866 998

89 973 846 665 398 99 85 31 3 4 4 23 73 103 309 618 830 973

90 936 809 643 361 95 79 28 3 3 3 20 69 100 283 588 775 936

91 906 753 609 334 93 75 27 4 3 3 19 64 97 258 552 736 906

92 859 721 582 305 90 71 25 4 4 3 18 60 95 235 521 698 859

Page 13: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

13 / 22

93 808 690 543 280 88 67 23 3 4 3 17 57 92 214 491 665 808

94 738 650 503 254 85 62 21 4 4 4 16 54 90 196 455 632 738

95 680 614 475 237 83 60 19 4 3 4 14 51 86 179 425 594 680

96 625 567 443 215 80 57 18 4 4 4 13 49 83 165 395 554 625

97 576 522 416 197 78 53 17 4 4 4 13 46 80 154 373 516 576

98 533 475 382 180 76 50 16 4 4 4 11 44 76 143 339 474 533

99 494 439 351 166 74 47 15 4 4 4 10 42 74 132 309 435 494

100 456 411 320 155 71 45 14 4 4 4 10 39 72 122 286 402 456

101 425 385 292 145 69 42 13 4 4 4 9 38 68 115 260 374 425

102 396 358 268 136 67 40 12 4 4 4 9 36 65 109 237 349 396

103 367 334 247 127 65 38 11 4 5 4 8 34 63 104 217 325 367

104 341 310 228 119 63 36 11 4 5 4 8 31 60 97 197 304 341

105 312 289 210 111 61 34 10 4 5 4 6 29 58 91 184 283 312

106 287 270 191 102 58 32 9 4 5 5 6 27 56 85 171 263 287

107 267 252 176 95 56 30 8 4 5 5 6 26 53 79 159 246 267

108 251 236 163 88 54 28 8 4 5 4 6 24 51 74 149 230 251

109 236 218 153 83 51 26 7 4 4 4 5 23 49 69 140 215 236

110 223 205 144 78 49 24 7 4 5 5 5 22 46 65 131 200 223

111 209 192 136 73 47 22 6 4 4 4 5 20 45 62 125 186 209

112 197 181 129 70 45 21 6 5 5 4 5 19 43 58 118 174 197

113 188 170 122 65 42 20 5 4 5 3 5 17 41 55 111 164 188

114 180 162 115 62 40 18 6 4 5 4 5 16 39 52 106 155 180

115 171 154 110 59 38 17 5 4 5 5 4 15 37 49 102 148 171

116 162 147 103 56 37 16 4 5 4 4 4 14 35 47 97 141 162

117 155 141 99 52 35 15 5 4 5 4 5 13 34 45 93 135 155

118 148 134 94 49 33 14 4 5 5 5 4 12 32 42 88 130 148

119 140 126 88 47 31 12 5 4 5 5 4 11 30 40 84 125 140

120 126 119 84 44 29 12 4 4 5 5 4 11 28 38 80 117 126

121 115 111 80 40 27 10 4 5 5 5 5 10 26 36 75 109 115

122 103 104 76 37 25 10 4 5 4 5 3 9 24 34 70 102 103

123 94 99 72 35 24 9 4 5 5 5 4 9 23 31 66 97 94

124 85 93 67 32 22 8 4 5 5 5 4 8 21 30 62 91 85

Page 14: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

14 / 22

125 78 87 63 30 20 8 4 4 5 4 5 8 20 28 57 86 78

126 74 82 58 28 19 8 4 5 5 5 5 7 18 26 53 81 74

127 69 77 55 26 18 7 4 5 5 5 4 7 17 24 48 77 69

128 66 72 50 24 16 6 4 5 5 5 5 6 16 23 44 72 66

129 62 67 47 22 15 6 4 5 5 5 5 6 15 22 40 67 62

130 58 62 43 21 14 6 4 5 5 5 5 6 14 20 37 63 58

131 55 57 39 19 13 6 5 5 5 5 5 5 13 18 33 59 55

132 52 54 34 18 13 6 4 5 5 5 5 5 12 17 29 54 52

133 49 49 30 16 12 5 5 5 4 5 4 5 11 16 25 49 49

134 47 45 26 15 10 5 5 5 6 5 5 5 10 15 22 45 47

135 44 41 22 14 10 5 5 6 6 5 5 5 10 14 19 41 44

136 40 36 19 13 10 5 5 6 6 6 5 5 9 13 16 35 40

137 37 32 15 12 9 4 5 6 6 6 5 5 9 12 12 31 37

138 33 28 13 11 9 5 5 6 6 5 5 5 8 11 10 27 33

139 29 24 10 10 9 5 5 5 6 6 5 5 8 10 9 23 29

140 26 21 8 9 8 5 4 6 6 6 5 5 7 9 9 19 26

141 22 18 7 9 7 5 5 6 6 6 6 5 7 9 8 16 22

142 18 14 7 8 7 5 5 6 6 6 5 5 6 8 7 13 18

143 15 12 6 6 7 4 5 6 6 6 6 5 6 7 7 10 15

144 12 10 6 7 6 5 5 6 6 6 6 6 6 7 6 8 12

145 10 7 5 6 6 5 5 6 6 6 6 5 6 6 6 6 10

146 8 6 5 6 6 5 6 6 6 6 6 5 6 6 5 4 8

147 6 3 5 6 6 5 5 6 7 6 6 5 5 6 6 4 6

148 4 3 5 6 6 5 6 6 7 6 7 6 6 5 5 4 4

149 4 4 4 5 6 5 6 6 6 6 6 6 5 5 4 4 4

150 3 4 4 5 6 5 6 6 6 6 6 6 6 5 5 5 3

151 4 4 4 5 5 5 6 6 6 6 6 6 6 5 5 4 4

152 4 4 4 4 6 5 6 6 6 6 7 6 5 5 5 5 4

153 4 4 5 4 6 6 6 7 6 6 7 6 6 5 5 4 4

154 5 4 5 5 6 5 6 6 6 6 7 6 6 4 5 4 5

155 5 3 5 5 5 5 6 6 6 6 6 5 6 5 5 5 5

156 4 4 4 5 6 5 6 7 6 6 6 6 6 5 5 5 4

Page 15: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

15 / 22

157 4 5 5 4 6 5 6 6 6 6 6 6 6 5 5 5 4

158 5 4 5 4 7 5 6 6 7 6 6 6 5 5 5 4 5

159 4 4 5 5 6 5 6 7 6 6 6 6 6 5 5 5 4

160 4 5 5 5 7 6 7 7 6 6 6 6 6 5 5 5 4

161 5 4 5 5 7 5 6 7 6 6 7 6 6 6 6 5 5

162 5 5 4 5 7 6 6 7 6 6 7 6 6 5 5 5 5

163 5 5 5 5 6 6 7 7 6 7 7 6 6 5 5 5 5

164 4 5 5 5 7 6 6 7 6 6 7 6 6 6 5 5 4

165 5 5 5 5 7 6 6 6 7 7 6 6 6 6 6 4 5

166 6 5 5 5 7 6 6 7 7 6 6 6 6 5 5 5 6

167 5 5 5 5 7 6 7 7 6 7 7 6 6 6 6 6 5

168 5 5 6 4 7 6 6 7 6 7 6 6 6 5 6 5 5

169 5 5 6 5 7 6 7 7 7 7 7 6 6 6 6 6 5

170 6 5 6 5 6 6 7 7 7 6 6 6 6 5 6 6 6

171 5 5 5 6 7 6 7 6 7 6 7 7 6 6 6 6 5

172 5 5 6 5 7 6 7 7 7 6 7 6 6 5 6 6 5

173 5 5 6 5 6 6 7 6 7 7 7 7 7 6 6 6 5

174 6 5 5 6 7 6 7 6 6 6 7 6 6 6 6 5 6

175 6 5 5 6 7 6 6 7 6 6 6 6 6 6 6 6 6

176 5 5 6 6 7 6 6 6 6 5 6 6 7 6 6 6 5

177 5 5 5 5 7 6 6 6 6 6 6 6 6 4 6 6 5

178 5 5 6 5 7 6 6 6 6 6 6 6 6 5 6 6 5

179 5 5 5 6 7 6 6 6 6 5 6 5 6 6 6 6 5

180 6 5 5 6 7 6 6 5 6 5 5 5 6 6 6 6 6

Page 16: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

16 / 22

Page 17: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

17 / 22

2.2 Electrical, Photometric and Chromaticity Measurements(Refer to Work Instruction BL-QP-033)

Test date 2019-07-16 Test Ambient: 25.2 º C

Test Orientation As intended Stabilization Time (min) 90

Model Number AST-SWP01-55BA2-abcd57

Electrical Measurement:Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD%

BLC1907022E-A2

120.0 60 0.4622 54.46 0.982 14.42

277.0 60 0.2204 55.24 0.905 12.96

DLC Pass Criteria >= 0.9(-3%) <= 20(+5)

Chromaticity Measurement - Sphere-Spectroradiometer Method:Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 80 R9 0

Frequency (Hz) 60 R2 87 R10 69

CCT (K) 5652 R3 91 R11 81

Duv 0.00256 R4 81 R12 57

Chromaticity (x, y) x=0.3290 y=0.3431 R5 81 R13 82

Chromaticity (u’, v’) u(u')=0.2038 v'=0.4781 R6 82 R14 95Color Rendering Index (CRI) 81.7 R7 86 R15 74

R9 0 R8 66 -- --

Photometric Measurement – Sphere-Spectroradiometer Method:Parameter Result DLC V4.4 Pass Criteria

Test Voltage (V) 120.0 277.0--

Frequency (Hz) 60 60

Total Luminous (lm) 7211.0 7244.2 5000-10000 (-10%)

Luminous Efficacy (lm/W) 132.41 131.14Premium: >= 115(-3%)

Most worst Luminous/Highest Watts 130.54

Page 18: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

18 / 22

Spectral Power Distribution & Chromaticity Diagram

Page 19: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

19 / 22

TM30

Page 20: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

20 / 22

Page 21: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

21 / 22

Calculated Efficacy Data for family models (4500K, 5000K):Model Number Luminous Flux (lm) Power (W) Efficacy (lm/W)

AST-SWP01-55BA2-abcd40 7033.9 54.38 129.35AST-SWP01-55BA2-abcd45 7078.2 54.42 130.07AST-SWP01-55BA2-abcd50 7122.5 54.42 130.88AST-SWP01-55BA2-abcd57 7211.0 54.46 132.41

*1: This value is calculated and the calculation formula is as below:7078.2=(7211.0-7033.9)/4+7033.97122.5=(7211.0-7033.9)/4+7078.2*2: This value is calculated and the calculation formula is as below:54.42= (54.38+54.46)/2*3: This value is calculated and the calculation formula is as below:130.07=7078.2/54.42130.88=7122.5/54.42

Page 22: Beyond LED Technology...Surge-Protective Device provided or not; “c” can be “R” or blank for PIR Sensor provided or not; “d” can be “P” or blank for Photocontrol provided

Report No.: BLC1907022E-A

Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,

Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012

22 / 22

3. Test Equipment

Equipment Name Model No. Serial No. Next Calibration Date

Goniophotometeric System GPM-3000 DYHXF120001 2020-01-14

AC Power Source CHP-500C N/A 2020-01-13

Total Luminous Flux StandardLamp

24V/150W DYJYR040040 2020-01-21

Digital Power Meter WT500 DYDWQ200006 2020-01-13

Integral Sphere (2M) 2M DYJCE120067 2020-01-14

Digital Power Meter WT500 DYDWQ200006 2020-01-13

Optical Color and ElectricalMeasurement System

CMS-3000S DYJCE120067 2020-01-14

Expand Uncertainty:Photometric Measurement (Sphere): 2.08%, k=2Chromaticity Measurement(Sphere):25.6K, k=2Photometric Measurement(Goniophotometer):2.645%, k=2

****** END OF REPORT ******