Dr. Vidyavati Dr. Vidyavati Professor of ophthalmology Professor of ophthalmology Sarojini Devi Eye Hospital, Hyderabad Sarojini Devi Eye Hospital, Hyderabad Beyond The Second Dimension Beyond The Second Dimension This watermark does not appear in the registered version - http://www.clicktoconvert.com

Upload: vuongdang

Post on 29-Aug-2019

213 views

Category:

Documents


0 download

TRANSCRIPT

Dr. VidyavatiDr. VidyavatiProfessor of ophthalmologyProfessor of ophthalmology

Sarojini Devi Eye Hospital, HyderabadSarojini Devi Eye Hospital, Hyderabad

Beyond The Second DimensionBeyond The Second Dimension

This watermark does not appear in the registered version - http://www.clicktoconvert.com

LATERAL EYES

FRONTAL EYES

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Why two eyes ?Why two eyes ?

l Just to have a spare

l Wider field of vision when using two eyes

compared to one.

l Stereoscopic vision by blending slightly

dissimilar views of an object , which is then

seen singly and with depth.

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Binocular viewingBinocular viewing

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Stereopsis Stereopsis l The relative ordering of visual

objects in the third dimension

This watermark does not appear in the registered version - http://www.clicktoconvert.com

l Stereopsis is obtained from fusible

but disparate retinal images falling

within Panum’s area. While

horizontal disparity produces

stereopsis , vertical disparity does

not result in any such perception .

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Panum’s areaPanum’s area

l Region around the horopter in horizontal space in

which single vision is present.

l Small in center, larger in periphery.

This watermark does not appear in the registered version - http://www.clicktoconvert.com

StereopsisStereopsis

l It is not a form of simple fusion

l Develops by the age of 3 months & is

established by 6 months

l It occurs when retinal disparity is too big to

permit simple fusion but not big enough to

elicit diplopia. ( A bridge between fusion

and diplopia )

This watermark does not appear in the registered version - http://www.clicktoconvert.com

l It ranges from 20 to 2000 ft

(7000 times the IPD)

l Stereo acuity is the smallest amount

of retinal image disparity that produces

stereopsis ,and is measured in seconds

of arc.

StereopsisStereopsis

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Testing forTesting forstereopsis stereopsis

l Essentially the two eyes must be

dissociated, and presented with a

separate field of view and targets

with fiducial marks.

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Categories ofCategories ofAvailable TestsAvailable Tests

l Self contained

- Two pencil test - Lang I & II

- Synoptophore - Frisby

l Those that need polaroid or red green

glasses

- Titmus fly - Random dot Butterfly

- Random dot - TNO

- Randot E

l Mentor B – Vat

l Bioptogram

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Two pencil test

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Synoptophore Synoptophore

l Slides are presented to the two eyes

at slightly disparate angles

l Used for testing gross stereopsis

l Braddick slides test detailed stereopsis

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Lang TestLang Test

l Test I measures from 600 to 1200 sec

of arc

l Test II measures from 200 to 1200 sec

of arc

l Unique feature – No glasses need to be

worn for viewing the test plate

This watermark does not appear in the registered version - http://www.clicktoconvert.com

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Titmus fly testTitmus fly test

Basis : Principle of linear polarization

Measures 40 to 3000 sec of arc

l Wings of the fly - 3000 sec

lLozenges - 40 to 800 secs

l Animals - 200 to 400 secs –

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Principle

Images formed of dots which are displaced

in relation to one another, the intervening

space being randomly filled by dots. Each

eye sees a separate set of dots , which

when fused result in a stereo image.

Random dot tests

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Random Dot Butterfly Random Dot Butterfly

l Butterfly

– Top of upper wings 2000 sec

– Bottom of lower wings 1150 sec

– Tip of abdomen 700 sec

l Circles 40 to 800 sec

l Animals 100 to 400 sec

This watermark does not appear in the registered version - http://www.clicktoconvert.com

l For infants ( 6 months onwards)

Randot stereo

smile test

This watermark does not appear in the registered version - http://www.clicktoconvert.com

l Randot for preschool children

l 80-400 sec of arc

Randot test

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Randot ‘E’ TestRandot ‘E’ Test

l Direction of tumbling ‘E’ is an added

feature

l Can be done at varying distances

l Measures

– At ½ meter 50 secs of arc

– At 5 meters 504 secs of arc

This watermark does not appear in the registered version - http://www.clicktoconvert.com

TNO Test TNO Test

Principle : Random dot and anaglyph

images. ( Viewed with Red & Green glasses )

l Used for quantitative assessment of

stereo acuity without changing distance

l Range 15 to 480 secs of arc

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Anaglyphs Anaglyphs

This watermark does not appear in the registered version - http://www.clicktoconvert.com

MentorMentorBB--Vat system Vat system

l Measures distance stereo acuity

l Done with tumbling ‘E’ image

l Liquid crystal glasses and microprocessor

attachment

l Screen presents disparate images that

alternate rapidly ( 60 cycles / sec )

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Bioptor Vision TestsBioptor Vision Tests

l Test 5a – for measuring distance stereo

acuity

l Range A to F measures 400 to 24 sec arc

l Useful in binocular imbalance (with eso or exo

bias)

This watermark does not appear in the registered version - http://www.clicktoconvert.com

BioptogramBioptogram

This watermark does not appear in the registered version - http://www.clicktoconvert.com

Thank YouThank YouThis watermark does not appear in the registered version - http://www.clicktoconvert.com