GTR7 Head Restraints – Phase 2 BIORID IIG RESPONSE TO VARYING COMFORT FEATURE STIFFNESS AND VARYING SEATBACK ROTATIONAL STIFFNESS (TESTS CONDUCTED UNDER IIWPG PROTOCOL) G. Locke Feb. 28-Mar. 1, 2011

Upload: others

Post on 04-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

BIORID IIG RESPONSE TO VARYING COMFORT FEATURE STIFFNESS AND VARYING SEATBACK ROTATIONAL STIFFNESS (TESTS CONDUCTED UNDER IIWPG PROTOCOL)

G. LockeFeb. 28-Mar. 1, 2011

Gianotti
Text Box
GTR7-06-07
Page 2: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

PURPOSEOriginal Knowing that the seat response plays a significant role in rear impact neck

injury protection, what is the influence of different comfort feature and seatback deflection combinations on the IIWPG rating

GTR7 Phase 2 Considerations Can the BioRID II distinguish between comfort systems and identify a better

design choice for neck injury protection? Can the BioRID II response identify a difference in seat frame stiffness

(rotation) for a given comfort feature? Is the BioRID II response repeatable enough to make reliable design choices

for neck injury protection? Report observations relevant to the injury evaluation parameters and limits

proposed by Japan

Page 3: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

TEST SET-UP

BioRID II build level: gIIWPG Test Protocol

Same seat cushion and adjuster assembly design for all tests

Fresh seatback assembly for each test -same backframe ,foam, trim and head restraint design for all tests

Passive h/r with EPP core

Recliners converted to free-pivots and seatback rotation controlled by spring-damper system – three rotation angles (7, 10 & 15 degrees)

Three common seatback comfort systems tested – two tests at each seatback rotation angle

String-potentiometers measuring upper and lower dummy penetration

Page 4: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

DESCRIPTION OF SEATBACK COMFORT SYSTEMS

STATIC SUSPENSION

HORIZONTAL LUMBAR

VERTICAL LUMBAR

Page 5: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

TEST SET-UP: BACKSET BY SEATBACK COMFORT SYSTEM

Horizontal Lumbar has smallest backset as there is no foam support in the upper seatback and initial seatback angle is smallest

Static Suspension has largest backset due to most uniform and prominent foam support

Vertical Lumbar similar to, but slightly less than Static Suspension

Seatback AngleBackset (mm) Height (mm) Initial (degrees)

H051 55 53 20.7H052 50 54 20.5H103 50 49 20.6H104 56 56 20.5H155 56 51 20.8H156 53 56 20.5S051 69 56 22.2S052 70 60 22.2S103 64 58 21.2S104 67 61 21.4S155 72 61 22.0S156 64 60 21.7V051 61 49 20.3V052 70 57 21.8V103 64 57 21.4V104 66 62 21.2V155 60 65 21.8V156 65 56 21.9

BioRID IITest ID

Page 6: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

MECHANICAL RESPONSE CONSIDERATIONS

Sled pulse very consistent

Spring-damper reaction repeatable

Seat back rotation consistent by lumbar type, but rotation rate is influenced by lumber type (measured using DTS angular rate sensors)

Static Suspension and Horizontal Lumbar showed consistent mechanical response

Vertical Lumbar motor bracket (mid-frame and engages side-members) showed inconsistent deformation, contributing to BioRID response variation

Page 7: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

Page 8: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

Page 9: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

Page 10: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

Page 11: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

Page 12: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

Vertical Lumbar motor bracket deformed and disengaged from side-member (V051)

Page 13: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

V051 bracket disengagement

Page 14: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

V051 bracket disengagement

Horizontal maximums

Page 15: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

V051 bracket disengagement

Page 16: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

V051 bracket disengagement

Page 17: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

V051 bracket disengagement

Page 18: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

V051 bracket disengagement

Page 19: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

V051 bracket disengagement

Page 20: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

7 DEGREE SEATBACK ROTATION

V051 bracket disengagement

Page 21: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 22: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 23: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 24: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 25: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 26: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 27: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 28: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Horizontal maximums

Page 29: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 30: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 31: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 32: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 33: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 34: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

10 DEGREE SEATBACK ROTATION

Page 35: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 36: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 37: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 38: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 39: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 40: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 41: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 42: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 43: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 44: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 45: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 46: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 47: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 48: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

15 DEGREE SEATBACK ROTATION

Page 49: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

COEFFICIENTS OF VARIATION

Page 50: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

CV CALCULATION DISCLOSURES

Sample size of two for all CV values reported

Maximum values used for CV calculations were determined between time zero and the end of head contact

Negative upper shear values defaulted to zero (per consumer rating system protocols

Undetermined if this is appropriate for regulation

The absolute value of extension moment values were used

In cases where data anomalies were correlated to seat mechanical issues (i.e.. Vertical Lumbar system), the CV will not be reported

Page 51: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

CV VALUES OF STATIC SUSPENSION AT 7 DEGREE S/B ROTATION

Page 52: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

CV VALUES OF STATIC SUSPENSION AT 10 DEGREE S/B ROTATION

Occipital My extension values low (2.67, 1.23)

Page 53: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

CV VALUES OF STATIC SUSPENSION AT 15 DEGREE S/B ROTATION

Occipital My extension values very low (1.56, 0.52)

Page 54: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION

Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV calculation and CV=0 (otherwise, the CV=-0.499 or 49.9%)

Occipital My extension values low (1.80, 2.49)

Page 55: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

CV VALUES OF HORIZONTAL LUMBAR AT 10 DEGREE S/B ROTATION

Upper Fx values very low (-1.72, 2.2), negative value set to zero

Occipital My extension values low (3.57, 1.78)

Page 56: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

CV VALUES OF HORIZONTAL LUMBAR AT 15 DEGREE S/B ROTATION

Page 57: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

CONCLUSIONS

Caution: CV values of samples with small magnitudes (near zero) are exaggerated

BioRID IIg acceleration responses are very repeatable (CV < 5%)

BioRID IIg NIC value is repeatable (CV < 10%)

BioRID IIg neck loads are marginal (CV<23%), with the exception of Occipital Extension Moment which is not repeatable

BioRID IIg is capable of distinguishing between the various stiffness’ of some comfort features currently in the market

BioRID IIg is capable of detecting mechanical anomalies of seatback features

BioRID IIg response generally increases with a decrease in seat frame stiffness (increase in seatback rotation)

Page 58: BIORID IIG RESPONSE TO VARYING COMFORT FEATURE …€¦ · CV VALUES OF HORIZONTAL LUMBAR AT 7 DEGREE S/B ROTATION Upper Fx actual values of -3.72 N and -1.78 N set to zero for CV

GTR7 Head Restraints – Phase 2

BIORID IIG INJURY PARAMETER OBSERVATIONS

BioRID IIg Lower Fx generally 4x-10x the magnitude of Upper Fx stiffer seat has higher multiplier

BioRID IIg Upper Fz generally 2x the magnitude of Lower Fz

BioRID IIg Lower My is predominantly extension and generally 1.5x-2x the magnitude of Occipital My in flexion less stiff seat has higher multiplier