7/27/2019 Bird SA-2000 Manual http://slidepdf.com/reader/full/bird-sa-2000-manual 1/124 SITE ANALYZER™ CABLE AND ANTENNA TESTER FOR WIRELESS SYSTEMS OPERATING INSTRUCTIONS ©Copyright 1999, 2002 by Bird Electronic Corporation Instruction Book Part Number 920-7002A800 Revision K Site Analyzer is a trademark of Bird Electronic Corporation Microsoft® and Windows® are registered trademarks of the Microsoft Corporation

Upload: josesgabo

Post on 14-Apr-2018

226 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 1/124

SITE ANALYZER™

CABLE AND ANTENNA TESTERFOR WIRELESS SYSTEMS

OPERATING INSTRUCTIONS

©Copyright 1999, 2002 by Bird Electronic CorporationInstruction Book Part Number 920-7002A800 Revision K

Site Analyzer is a trademark of Bird Electronic CorporationMicrosoft® and Windows® are registered trademarks

of the Microsoft Corporation

Page 2: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 2/124

Page 3: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 3/124

i

Safety Precautions

Remove Power 

Observe general safety precautions. Do not open the instrument withthe power on.

Safety Earth Ground 

 An uninterruptible safety earth ground must be supplied from themain power source to the instrument. Grounding one conductor of atwo conductor power cable is not sufficient protection. Serious injury

or death can occur if this grounding is not properly installed.Safety Symbols

The caution symbol appears on the equipment indicatingthere is important information in the instruction manualregarding that particular area. See page 82 for specificcautions.

NOTE: Calls attention to supplemental information.

Warning Statements

The following safety warnings appear in the text where there isdanger to operating and maintenance personnel, and are repeatedhere for emphasis.

WARNINGWarning notes call attention to a procedure, which if not correctly

performed, could result in personal injury.

CAUTIONCaution notes call attention to a procedure, which if not correctly

performed, could result in damage to the instrument.

WARNINGThe SA-BATPAK is shipped charged. Be careful when removing thesafety cap, 12Vdc @ 2.0 AH/20 hour rate can be present inside the

receptacle. Do not touch the inside of the receptacle. The possibilityof an electric shock exists.

Page 4: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 4/124

Bird Site Analyzer 

ii

Caution Statements

The following equipment cautions appear in the text and are repeatedhere for emphasis.

Safety Statements

USAGE

 ANY USE OF THIS INSTRUMENT IN A MANNER NOTSPECIFIED BY THE MANUFACTURER MAY IMPAIRTHE INSTRUMENT’S SAFETY PROTECTION.

USO

EL USO DE ESTE INSTRUMENTO DE MANERA NO

ESPECIFICADA POR EL FABRICANTE, PUEDE ANULAR LAPROTECCIÓN DE SEGURIDAD DEL INSTRUMENTO.

BENUTZUNG

WIRD DAS GERÄT AUF ANDERE WEISE VERWENDET ALS VOMHERSTELLER BESCHRIEBEN, KANN DIE GERÄTESICHERHEITBEEINTRÄCHTIGT WERDEN.

WARNINGThis equipment should not be connected to an antenna or operated

during a storm that has the potential to produce lightning. The

possibility exists for electrical shock.

WARNINGWhen using the ac adapter, only connect the plug to a properly

grounded receptacle. Serious injury or death can occur if groundingis not properly installed.

CAUTIONHarsh or abrasive detergents, and some solvents, can damage the

display unit and information on the labels.

CAUTION

When using a Bird 5011, do not exceed 2 W average or 125 W peakpower for 5 µs. Doing so will render the sensor inoperative.

CAUTION+22 dBm max. input

Do not apply RF power to Antenna Test Port. Exceeding themaximum input will damage the Site Analyzer.

Page 5: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 5/124

iii

UTILISATION

TOUTE UTILISATION DE CET INSTRUMENT QUI N’EST PASEXPLICITEMENT PRÉVUE PAR LE FABRICANT PEUT

ENDOMMAGER LE DISPOSITIF DE PROTECTION DEL’INSTRUMENT.

IMPIEGO

QUALORA QUESTO STRUMENTO VENISSE UTILIZZATO INMODO DIVERSO DA COME SPECIFICATO DAL PRODUTTORELA PROZIONE DI SICUREZZA POTREBBE VENIRNECOMPROMESSA.

SERVICESERVICING INSTRUCTIONS ARE FOR USE BY SERVICE - TRAINED PERSONNEL ONLY. TO AVOIDDANGEROUS ELECTRIC SHOCK, DO NOT PERFORM

 ANY SERVICING UNLESS QUALIFIED TO DO SO.

SERVICIO

LAS INSTRUCCIONES DE SERVICIO SON PARA USO

EXCLUSIVO DEL PERSONAL DE SERVICIO CAPACITADO. PARAEVITAR EL PELIGRO DE DESCARGAS ELÉCTRICAS, NOREALICE NINGÚN SERVICIO A MENOS QUE ESTÉCAPACITADO PARA HACERIO.

WARTUNG

 ANWEISUNGEN FÜR DIE WARTUNG DES GERÄTES GELTENNUR FÜR GESCHULTES FACHPERSONAL.

ZUR VERMEIDUNG GEFÄHRLICHE, ELEKTRISCHE SCHOCKS,SIND WARTUNGSARBEITEN AUSSCHLIEßLICH VONQUALIFIZIERTEM SERVICEPERSONAL DURCHZUFÜHREN.

ENTRENTIEN

L’EMPLOI DES INSTRUCTIONS D’ENTRETIEN DOIT ÊTRERÉSERVÉ AU PERSONNEL FORMÉ AUX OPÉRATIONSD’ENTRETIEN. POUR PRÉVENIR UN CHOC ÉLECTRIQUEDANGEREUX, NE PAS EFFECTUER D’ENTRETIEN SI L’ON N’A

PAS ÉTÉ QUALIFIÉ POUR CE FAIRE. ASSISTENZA TECNICA

LE ISTRUZIONI RELATIVE ALL’ASSISTENZA SONO PREVISTEESCLUSIVAMENTE PER IL PERSONALE OPPORTUNAMENTE

 ADDESTRATO. PER EVITARE PERICOLOSE SCOSSEELETTRICHE NON EFFETTUARRE ALCUNA RIPARAZIONE AMENO CHE QUALIFICATI A FARLA.

Page 6: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 6/124

Bird Site Analyzer 

iv

About This Manual

This instruction book covers the Bird Site Analyzer Models SA-2000,SA-2000A, and SA-2500A.

Changes to This Manual 

We have made every effort to ensure this manual is accurate. If youshould discover any errors, or if you have suggestions for improving thismanual, please send your comments to our Solon, Ohio factory. Thismanual may be periodically updated. When inquiring about updates tothis manual refer to the part number and revision level on the title page.

Quick Start and Reference Card 

The Quick Start and Reference Card contains minimum operationalsteps and the order they should be performed. Use this manual forreference or if further explanation of any step is required.

Site Analyzer Keys

There are two types of keys on the Site Analyzer. The first type is a hardkey with a particular function. The function is indicated on or next to thekey. Hard key names are set in a bold type, e.g., Press the ENTER key.

The second type is a soft key. Each of the soft keys (there are five to theleft of the display), has a corresponding soft key legend which dependson the function selected. The name will be at the left of the display,directly to the right of the corresponding key. Soft key names are set in abold italic type, e.g. Press the SCALE key. Refer to the figure below.

Soft Key

Hard Key

 A magnified softkey legend is aninstruction topress the

correspondingsoft key.

Soft Key Legend

Page 7: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 7/124

v

Chapter Layout 

Introduction — Identifies the parts, functions, and features of the Site Analyzer as well as optional equipment available.

Getting Started — Provides power up information for the Site Analyzer.

Calibration — Provides step by step instructions for calibrating theSite Analyzer, which must be done before using Measure Match orFault Location modes.

Measure Match Mode — Lists the steps required to make matchmeasurements, as well as providing instructions for all functions

available in Measure Match mode.

Fault Location Mode — Lists the steps required to make distance tofault measurements, as well as providing instructions for all functionsavailable in Fault Location mode.

Save and Recall — For units with the most recent firmware revision.Describes how to save, recall, and delete traces and setups in MeasureMatch or Fault Location modes.

Old Save and Recall — For firmware older than 1-Nov-2001.Describes how to save, recall, and delete traces and setups in MeasureMatch or Fault Location modes.

Measure Power Mode — Lists the steps required to make powermeasurements, as well as providing instructions for all functionsavailable in Measure Power mode.

Utilities — Describes utilities to set up the Site Analyzer.

Computer Software — Provides installation instructions and lists thefeatures of the Bird Site Analyzer PC Software.

Maintenance — Lists routine maintenance tasks for the Site Analyzer, as well as troubleshooting for common problems.Specifications and parts information are also included.

Page 8: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 8/124

vi

Table of Contents

Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i

About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Items Supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Items Not Supplied. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Site Analyzer Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

 Antenna Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Transmitter Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Component Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Connection Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Display Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Internal Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

External Battery Pack (Optional) . . . . . . . . . . . . . . . . . . . . . . . . 11

Power Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Self Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

System Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Calibration Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15Calibrating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Measure Match Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Setting the Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Band List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Setting the Scale & Unit of Measure . . . . . . . . . . . . . . . . . . . . . . . . 21

 Auto Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Setting Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Cable Loss Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Limit Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Limit Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Marker Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Measurement Hold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Printing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Page 9: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 9/124

vii

Fault Location Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Setting the Frequency Span . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Setting the Cable Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

Cable List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Setting the Distance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Setting Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Setting the Scale & Unit of Measure . . . . . . . . . . . . . . . . . . . . . . . . 42

 Auto Scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Setting Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Limit Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Limit Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Marker Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Smooth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Measurement Hold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Printing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Save and Recall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53

Save Trace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Trace Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55

Trace Label Quicktext . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Trace Label Config. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

Save Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65

Recall Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66

Recall Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Delete Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

Delete Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

Old Save and Recall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

Save Trace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

Label and Sort Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

Save Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75

Recall Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76

Recall Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

Delete Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

Delete Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

Measure Power Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81Connecting a Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

Setting the Full Scale Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

Setting the Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

Recall Setups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

Choosing the Displayed Measurement . . . . . . . . . . . . . . . . . . . . . . 86

Setting Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

Page 10: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 10/124

viii

Calibrating the Bird 5011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88

Utilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

 Adjust Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

Return to Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

FM Modulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

Computer Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

Computer Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Charging the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100

Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102

Unit Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103

Flash ROM Upgrade (SA-2500A Only) . . . . . . . . . . . . . . . . . . . . . 104

EPROM Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105

Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

Optional Equipment Available . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111

Page 11: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 11/124

1

Chapter 1 Introduction

The Bird Site Analyzer is a multifunction testinstrument for use in installation and maintenance of wireless systems.

 Antenna systems are tested by using a Site Analyzerto measure match conditions. Data is graphed at 238points across a user-specified frequency band ordistance range. Transmitter systems are tested by

using a Site Analyzer and a Bird power sensor tomeasure RF power. Data is displayed as power ormatch efficiency, depending on the sensor.

Items Supplied 

1. Site Analyzer2. Soft-Sided Carrying Case

3. PCTool Software4. AC Power Adapter5. Automobile Cigarette Lighter Adapter6. 9-Pin Serial Communications Cable7. Instruction Manual (Not Shown)8. Quick Start and Reference Cards (Not Shown)

Page 12: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 12/124

Bird Site Analyzer 

2

Items Not Supplied 

y Calibration Combination

y Bird 5010 Directional Power Sensor

y Bird 5011 Terminating Power Sensor

Site Analyzer Features

General

y Field replaceable Li-ion battery.

y  Automatic power down conserves battery life.Antenna Test

y Rejects on-channel interfering signals to +13 dBm.y Stores up to 15 calibration profiles.y  Adjustable pass/fail limit line with visual indicator.

Page 13: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 13/124

Introduction

3

y Stores up to 300 sets of measurement data in rawformat to facilitate conversion between antennamatch and DTF.

y On-screen comparison between currentmeasurement and stored data – no PC required.

y Pop-up menus contain over 70 cable types and 30frequency band presets.

y X and Y scales and units are user adjustable.y Dual measurement markers and one difference

marker.y Measurement hold to temporarily store a trace.y Printing capability. The Bird Site Analyzer is

compatible with all printers that use HP PCLLevel 3, including most HP inkjet printers.

MeasureMatch Mode

y Fast swept measurement.y Frequency can be set using either Start/Stop or

Center/Span frequencies.y Measurement units can be either return loss [dB],

cable loss [dB], or VSWR [ratio].

FaultLocation

Mode

y Transform Algorithm - Fast Fourier Transform(FFT) with three levels of smoothing.

y Distance units can be either feet or meters.y Measurement units can be either return loss [dB] or

 VSWR [ratio].

Transmitter Test

MeasurePower Modey

Numerical readout and analog dial.y Can display either forward power, reflected power,

or match efficiency depending on the sensor.y Power measurement units can be either Watts or

dBm. Match units can be either VSWR, return loss,or % match efficiency.

y Compatible with the Bird Directional Power Sensor,Terminating Power Sensor, VSWR Alarms, andBroadcast Power Monitors.

Page 14: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 14/124

Bird Site Analyzer 

4

Component Description

1

2

3

4

5

6

7

8

9

Page 15: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 15/124

Introduction

5

1. Soft Keys  Activates the function described directly to theright of the key.

2. Mode Keys

Mode  Activates the mode menu. This menu allows theuser to select Measure Match, Fault Location,Measure Power, or Utilities modes.

Config  Activates the configuration menu for the currentmode. This menu provides access to the variablemeasurement parameters (e.g. frequency band,distance, and units).

Calibrate  Activates the calibration menu.Marker   Activates the marker menu. This menu allows

the user to turn markers is on or off and to movethe active marker.

3. Numeric Keys Enter numeric data into the selected item, or asdefined by the function description.

4. Escape Key

During:

Menu Selection Backs up one menu level.

Data Entry Exits data entry without changing the value.

5. Enter KeyDuring

List Selection Selects the highlighted item in the list.

Data Entry Exits data entry, changing the value.

6. Cursor Keys

Left ArrowDuring:

Data Entry Deletes previously entered data one character ata time.

Marker Control Moves active marker left one point at a time.

 All other times  As defined by the function description.

Page 16: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 16/124

Bird Site Analyzer 

6

Right ArrowDuring:

Marker Control Moves active marker right one point at a time.

 All other times  As defined by the function description.

Up ArrowDuring:

Data Entry Increases the numeric value.

Marker Control Moves the marker to the maximum trace value.

While pressingthe contrast key Increases the display contrast.

 All other times  As defined by the function description.

Down ArrowDuring:

Data Entry Decreases the numeric value.

Marker Control Moves the marker to the minimum trace value.While pressingthe contrast key

Decreases the display contrast.

 All other times  As defined by the function description.

7. Battery LED The yellow LED lights when the unit is poweredby an external dc power source. When chargingthe internal battery pack, the yellow LED blinks.Once the battery is fully charged the yellow LEDstops blinking.

The green LED lights whenever the unit is on.

8. Contrast Key Hold while pressing the up/down arrow keys toadjust the contrast of the display.

9. l/0 (On/Off) Turns the instrument on and off. The key must bepressed for at least one-half (½) second.

Page 17: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 17/124

Introduction

7

Connection Description

 AntennaTest Port

ParallelPrinter Port

Computer PortRemote Power Sensor 

DC Input

CAUTION+22 dBm max. input

Do not apply RF power to Antenna Test Port. Exceeding the maxi-mum input will damage the Site Analyzer.

Antenna Test Port Standard N-type female connector. Use aphase-stable armored cable to connectthe Site Analyzer to the antenna.

Optional Test Port Extension Cables and

adapters are listed in the AccessoryGuide Brochure.

Parallel Printer Port 25-pin (DB25) parallel connector.Connect the Site Analyzer to a HP-typeinkjet printer. The cable is not included.

Computer/Power Sensor Port 9-pin RS-232 (DB9) serial connector.9600 baud, 8 data bits, 1 stop bit, noparity, and no handshake. Connect the

Site Analyzer to a PC serial port or toBird power sensors.

DC Input Input for external power supplies. Plugeither the ac power supply or thecigarette lighter adapter into the dcinput. The external supplies operate theunit and charge the internal battery.

Page 18: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 18/124

Bird Site Analyzer 

8

Display Description

MeasureMatch

SampleDisplay 

825.00 MHz 841.00

Measure Match Mode

Calibration: Full

M2

M1

M1: 835.20 MHz

M2: 831.50 MHz

∆M: 3.70 MHz

1.64

1.20

0.44

Limit: 1.43

FAIL

1.70

1.00

V

SWR

Save/Recall

 AutoScale

LimitTest On

Run

Print

000, ABC, 01-JAN-2001 12:01

1 8

2 3 4 5

7

6

Fault Location

SampleDisplay 

0.0 Meters 18.2

Fault Location Mode

Calibration: Full

1.70

1.00

VSWR

Save/Recall

 AutoScale

LimitTest On

Run

Print

9 14

10 11 12

13

Page 19: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 19/124

Introduction

9

1. Trace Graphic display of the measurement.

2. Calibration Indicator  Indicates the calibration status.

3. Limit Line Value Indicates the limit value.

4. Limit Test Indicator  Displays FAIL if any part of the traceexceeds the limit value.

5. Limit Line  A horizontal line that graphicallydisplays the limit value.

6. Marker Value Indicates the position and value of atrace point.

7. Marker Cursor  Identifies the trace point displayed inthe marker value.

8. Recalled Name Indicates the name of a recalled trace.

9. Soft Key Description Describes the function of the soft key tothe left of the description.

10. Indicator Ball Indicates if the trace is sweeping.

11. Scale Indicates the minimum and maximumvalues displayed on that axis.

12. Units Indicates the measurement units forthat axis.

13. Battery Gauge Indicates whether the Site Analyzer isusing the internal battery or an externalpower supply, and indicates the amount

of battery life remaining.14. Mode Indicator  Name of the current mode.

Page 20: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 20/124

Bird Site Analyzer 

10

MeasurePower 

SampleDisplay 

Fwd 0.0 Watts

Refl

600.00

Match

0.00 Watts

0.00 Loss(dB)

Measure Power Mode

PwrUnitWatts

Sensor Connected

MatchUnitRtn Loss

DisplayFwd

1

2

3

4

5

6

7

1. Sensor Status Indicates the current status of powersensor.

2. Primary Measurement Identifies the measurement displayed onthe analog dial.

3. Primary Value Numeric display of the primary value.

4. Measurement Scale Indicates the dial’s full scale.

5. Dial Graphic display of the primarymeasurement.

6. Secondary Measurements Identifies the measurements notdisplayed on the dial.

7. Secondary Value Numeric display of the secondary values.

Page 21: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 21/124

11

Chapter 2  Getting Started

Power Supply 

InternalBattery

The Bird Site Analyzer has an internal, rechargeablelithium-ion battery pack. This will operate the unit fora minimum of 3 hours of continuous usage. Rechargingtime, from a full discharge, is approximately 4 hours.

NOTE: When the unit is received the battery may

not be fully charged. An ac adapter should be usedwhen operating the unit for the first time.

The battery gauge indicates the approximate batterylife remaining. At ¼ charge the gauge also displays“LO”. When using an external power source, a powercord symbol replaces the battery gauge.

Adapters The Bird Site Analyzer can be operated using an ac

adapter or a 12 V automobile cigarette lighter adapter.Using these will also charge the internal battery.

ExternalBatteryPack

(Optional)

The SA-BATPAK is an optional external battery pack.This will operate the unit for approximately 2 hours.The liquid acid gel battery will fully charge, from a fulldischarge, in about 6-8 hours.

WARNINGWhen using the ac adapter, only connect the plug to

a properly grounded receptacle. Serious injury ordeath can occur if not properly grounded.

WARNINGThe SA-BATPAK is shipped charged. Be careful

when removing the safety cap, 12Vdc @ 2.0 AH/20hour rate can be present inside the receptacle. Do

not touch the inside of the receptacle. The possibilityof an electric shock exists.

Page 22: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 22/124

Bird Site Analyzer 

12

To charge the external battery pack:

1. Plug the automobile cigarette lighter adapterinto the external battery pack on the side thatsays “To Battery”. Refer to the figure above.

2. Plug the other end of the automobile cigarettelighter adapter into the charger adapter.

3. Plug the ac adapter into the charger adapter.4. Plug the ac adapter into a properly grounded

outlet. The charger’s “On” LED comes on andstays on until the charger is disconnected.

To use the external battery pack with a Site Analyzer:

1. Plug the automobile cigarette lighter adapterinto the adapter of the charged externalbattery pack.

2. Plug the other end of the automobile cigarettelighter adapter into the dc input of the Site

 Analyzer.

SA-BATPAK 

1

2

3

4

     O     n

To

Battery

       E       l     e

     c       t

     r     o      n

       i     c

       C     o      r     p       o      r     a

       t       i

     o      n

     S      A

  -     B     A     T     P     A     K

     C      H     A     R     G      E     R

          1          5           V 2

  .          7          A

On

To

Battery

Electronic

Corporation

SA-BATPAK 

CHARGER 

15V

2.7A

Page 23: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 23/124

Page 24: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 24/124

Bird Site Analyzer 

14

Page 25: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 25/124

15

Chapter 3 Calibration

Calibration Accessories

Calibration Combination including:

y One 50 ohm loady One Open standardy One Short standard

Test Cable (optional) – Phase-stable for reliable,consistent results.

NOTE: If a test cable is used to connect the Site Analyzer system under test, attach the standardsto the end of the test cable during calibration.

Calibrating 

Press key from either 

MeasureMatch or 

Fault 

Locationmode

825.00 MHz 841.00

Calibration Mode

Calibration: Off 

1.70

1.00

    V    S

    W    R

Open

Short

Load

Cal Done

Page 26: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 26/124

Bird Site Analyzer 

16

y Press the CALIBRATE key.y  Attach the open standard.

Press the OPEN key.Wait for a “beep” and for the trace to scroll beforecontinuing.

y  Attach the short standard.Press the SHORT key.Wait for a “beep” and for the trace to scroll beforecontinuing.

y  Attach the load standard.Press the LOAD key.Wait for a “beep” and for the trace to scroll beforecontinuing.

y Press the CAL DONE key. New coefficients arecalculated. The Site Analyzer is now calibrated.

NOTE: Now is a good time to save the setup.Saving after calibration will save the newcalibration coefficients. See “Save Setup”, page 75.

Page 27: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 27/124

17

Chapter 4 Measure Match Mode

This measurement verifies and monitors the matchconditions in the antenna system at variousfrequencies. The results are shown on an x-y graph.Frequency is shown on the x-axis while return loss,cable loss, or VSWR is shown on the y-axis.

Set the frequency and calibrate the Site Analyzerbefore taking any readings.

Press theMode key 

Press fromSelect Mode 780.00 MHz 2500.00

Measure Match Mode

Calibration: OFF

99.99

1.00

VS

WR

Save/Recall

 AutoScale

LimitTest OFF

HOLD

Print

MeasureMatch

FaultLocation

Page 28: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 28/124

Bird Site Analyzer 

18

Setting the Frequency 

Frequencies can be set manually or chosen from a listof presets. If the start, stop, center, or span ismanually changed, the band will become “Custom”.

NOTE: Changing the frequency settings willautomatically turn calibration off. Always setthe frequency before calibrating the unit.

NOTE: If a frequency outside of the Site Analyzer’s range is entered, the unit’s minimum or

maximum frequency will be set instead.

Press fromMeasure

Match Mode

Press todisplay thefrequency 

settings780.00

MHz2500.00

Measure Match Mode

Start: 780.00 MHzStop: 2500.00 MHz

99.99

1.00

VSWR

Freq

Scale

LimitLine

CableLoss

Center: 1640.00 MHzSpan: 1720.00 MHz

Band List: Custom

Freq

Scale

Page 29: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 29/124

Measure Match Mode

19

Band List The band list pop-up menu contains frequency bandpresets. Using a preset is quick, easy, and sets testparameters while eliminating a possible source of 

operator error.

Scroll toStart, Stop,

Center, or Span

Enter a new value

1500.00 MHz 2500.00

Measure Match Mode

Start: 1500.00 MHzStop: 2500.00 MHz

99.99

1.00

VSWR

Freq

Scale

LimitLine

CableLoss

Center: 2000.00 MHzSpan: 1000.00 MHz

Band List: Custom

Scroll toBand List 

780.00 MHz 2500.00

Measure Match Mode

Start: 780.00 MHzStop: 2500.00 MHz

99.99

1.00

VSWR

Freq

Scale

LimitLine

CableLoss

Center: 1640.00 MHzSpan: 1720.00 MHz

Band List: Custom

Page 30: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 30/124

Bird Site Analyzer 

20

Display theband list 

and select afrequency 

band 

Measure Match Mode

Freq

Band Start StopScale

LimitLine

CableLoss

<Full Band>

IS-553(Rx)

IS-553(Tx)

IS-54(Rx)

IS-54(Tx)

IS-95(Rx)

IS-95(Tx)

IS-95(Rx)

780.00

824300

869.00

824.00

869.00

1850.00

1930.00

824.00

2500.00

849.00

894.00

849.00

894.00

1910.00

1990.00

849.00

 Activate theselected 

band 

824.00 MHz 849.00

Measure Match Mode

Start: 824.00 MHzStop: 849.00 MHz

99.99

1.00

VSWR

Freq

Scale

LimitLine

CableLoss

Center: 836.50 MHzSpan: 25.00 MHz

Band List: IS-54(Rx)

Page 31: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 31/124

Measure Match Mode

21

Setting the Scale & Unit of Measure

The display scale can be set manually or by using AutoScale. The display can have units of return loss [dB],cable loss [dB], or VSWR [ratio].

Press fromMeasure

Match Mode

Press todisplay the

scalesettings 780.00 MHz 2500.00

Measure Match Mode

Min: 1.00

Max: 99.99

99.99

1.00

VSWR

Freq

Scale

LimitLine

Cable

Loss

 Auto Scale

Units: VSWR

Freq

Scale

Scroll to Minor Max 

Enter a new value

780.00 MHz 2500.00

Measure Match Mode

Min: 10.00

Max: 99.99

99.99

10.00

    V    S     W    R

Freq

Scale

LimitLine

CableLoss

 Auto Scale

Units: VSWR

Page 32: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 32/124

Page 33: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 33/124

Page 34: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 34/124

Bird Site Analyzer 

24

 Activate theselected 

unit 

780.00 MHz 2500.00

Measure Match Mode

Min: -60.0 dB

Max: 0.0 dB

0.0

-60.0

RtnLoss(dB)

Freq

Scale

LimitLine

Cable

Loss

 Auto Scale

Units: Rtn Loss

Page 35: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 35/124

Measure Match Mode

25

Cable Loss Measurements

To measure cable loss, the cable being tested shouldhave an open on the far end.

Press fromMeasure

Match Mode

Press toactivate

Cable Loss780.00 MHz 2500.00

Measure Match Mode

Calibration: OFF

0.0

-60.0

CableLoss(d

B)

Freq

Scale

LimitLine

CableLoss

Cable Loss Mode

Press todeactivate

Cable Loss

780.00 MHz 2500.00

Measure Match Mode

Calibration: OFF

0.0

-60.0

RtnLoss(dB)

Freq

Scale

LimitLine

CableLoss

Page 36: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 36/124

Bird Site Analyzer 

26

Limit Line

The limit line is an option that helps you see a failure.It appears as a horizontal line at the limit line value.

Press fromMeasure

Match Mode

Press todisplay the

limit linevalue

Enter a new value 780.00 MHz 2500.00

Measure Match Mode

99.99

1.00

    V    S     W    R

Freq

Scale

LimitLine

CableLoss

Limit Line: 1.43

Page 37: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 37/124

Measure Match Mode

27

Limit Test 

Limit Test compares the trace to the limit line.

Test Off — disables the comparison and the pass/failindicator.

Test On — enables the comparison. If all of the trace isbelow the limit value, “PASS” is displayed at thebottom of the screen. If any part of the trace exceedsthe limit value, that portion is displayed in red and“FAIL” is displayed at the bottom of the screen.

Test Audio — as Test On. In addition, the Site Analyzer will beep if any part of the trace exceeds thelimit value.

Press fromMeasure

Match Mode

Togglebetween Off, Audio, & On

825.00 MHz 841.00

Measure Match Mode

Calibration: Full

Limit: 1.43

FAIL

1.70

1.00

V

SWR

Save/Recall

 AutoScale

LimitTest On

HOLD

Print

Page 38: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 38/124

Bird Site Analyzer 

28

Marker Adjustment 

Markers indicate VSWR to 0.01, or Return or CableLoss to 0.1 dB. The exact values of M1, M2, and thedelta marker (difference of M1 and M2) are displayedat the bottom of the screen.

NOTE: If M1 was Active, it becomes ON(displayed) when M2 becomes Active.

Press fromMeasure

Match Mode

Togglebetween Off,

On, and  Active

Togglebetween Off 

and Single825.00 MHz 841.00

Measure Match Mode

Calibration: Full

M2

M1

M1: 838.50 MHz

M2: 834.10 MHz

∆M: 4.40 MHz

1.40

1.30

0.10

1.70

1.00

VSWR

M1 Active

M2On

∆MSingle

Page 39: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 39/124

Measure Match Mode

29

Moveacross the

trace

Locate thehighest 

 point of the

trace

Locate thelowest point of the trace

825.00 MHz 841.00

Measure Match Mode

Calibration: Full

M2

M1

M1: 835.20 MHz

M2: 831.50 MHz

∆M: 3.70 MHz

1.64

1.20

0.44

1.70

1.00

VSWR

M1 Active

M2

On

∆MSingle

Page 40: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 40/124

Bird Site Analyzer 

30

Measurement Hold 

Measurement Hold stops tracing at the end of thecurrent measurement and displays the last measure-ment result. It is active when a lock appears in theindicator ball.

Press fromMeasure

Match Mode

TogglebetweenRun and 

Hold 

825.00 MHz 841.00

Measure Match Mode

Calibration: Full

1.70

1.00

VSWR

Save/Recall

 AutoScale

LimitTest Off 

Run

Print

Page 41: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 41/124

Measure Match Mode

31

Printing 

The Bird Site Analyzer can print the informationdisplayed on the screen to any HP Deskjet printer thatsupports the PCL Level 3 protocol.

Press fromMeasure

Match Mode

Prints theinformation

on thescreen

825.00 MHz 841.00

Measure Match Mode

Calibration: Full

1.70

1.00

VSWR

Save/Recall

 AutoScale

LimitTest Off 

Run

Print

M2

M1

M1: 835.20 MHz

M2: 831.50 MHz

∆M: 3.70 MHz

1.64

1.20

0.44

Page 42: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 42/124

Bird Site Analyzer 

32

Page 43: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 43/124

Page 44: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 44/124

Bird Site Analyzer 

34

Setting the Frequency Span

The frequency span and relative propagation velocitydetermine the maximum distance at which distance-to-fault measurements can be taken. For best results,use the table below to select the frequency span whichmatches the length and either the propagation velocityor dielectric constant of the cable under test.

NOTE: Changing the frequency settings willautomatically turn calibration off. Always setthe frequency before calibrating the unit.

Table 1: Frequency Span vs. Vp

VelocityPercentage

Dielectric Constant 

60%

2.778 

80%

1.562

100%

1

FrequencySpan (MHz)

Distanceft (m)

Resolutionin (cm)

Distanceft (m)

Resolutionin (cm)

Distanceft (m)

Resolutionin (cm)

1900 37 (11) 1.9 (4.7) 49 (15) 2.5 (6.3) 62 (19) 3.1 (7.9)

1800 39 (12) 2.0 (5.0) 52 (16) 2.6 (6.7) 65 (20) 3.3 (8.3)

1700 41 (13) 2.1 (5.3) 55 (17) 2.8 (7.1) 69 (21) 3.5 (8.8)

1600 44 (13) 2.2 (5.6) 59 (18) 3.0 (7.5) 73 (22) 3.7 (9.4)

1500 47 (14) 2.4 (6.0) 62 (19) 3.2 (8.0) 78 (24) 3.9 (10.0)

1400 50 (15) 2.5 (6.4) 67 (20) 3.4 (8.6) 84 (26) 4.2 (10.7)

1300 54 (16) 2.7 (6.9) 72 (22) 3.6 (9.2) 90 (27) 4.5 (11.5)

1200 59 (18) 3.0 (7.5) 78 (24) 3.9 (10.0) 98 (30) 4.9 (12.5)

1100 64 (19) 3.2 (8.2) 85 (26) 4.3 (10.9) 106 (32) 5.4 (13.6)

1000 70 (21) 3.5 (9.0) 94 (29) 4.7 (12.0) 117 (36) 5.9 (15.0)

900 78 (24) 3.9 (10.0) 104 (32) 5.3 (13.3) 130 (40) 6.6 (16.7)

800 88 (27) 4.4 (11.2) 117 (36) 5.9 (15.0) 146 (45) 7.4 (18.8)

700 100 (31) 5.1 (12.9) 134 (41) 6.8 (17.1) 167 (51) 8.4 (21.4)

600 117 (36) 5.9 (15.0) 156 (48) 7.9 (20.0) 195 (60) 9.8 (25.0)

500 141 (43) 7.1 (18.0) 187 (57) 9.5 (24.0) 234 (71) 11.8 (30.0)

400 176 (54) 8.9 (22.5) 234 (71) 11.8 (30.0) 293 (89) 14.8 (37.5)

300 234 (71) 11.8 (30.0) 312 (95) 15.8 (40.0) 390 (119) 19.7 (50.0)

200 351 (107) 17.7 (45.0) 469 (143) 23.6 (60.0) 586 (179) 29.5 (75.0)

Page 45: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 45/124

Page 46: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 46/124

Page 47: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 47/124

Page 48: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 48/124

Page 49: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 49/124

Fault Location Mode

39

 Activate theselected 

cable

0.0 Meters 17.0

Fault Location Mode

Vel. Prop.: 0.8200 Cable List: 5062Loss: 0.1447 dB/m

99.99

1.00

VSWR

Distance

Scale

LimitLine

Smooth

Low

Cbl Type

Page 50: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 50/124

Bird Site Analyzer 

40

Setting the Distance

The maximum possible Stop Distance is determinedby the frequency span. (See Table 1 on page 34)

Press fromFault 

LocationMode

Press todisplay the

distancesettings

Scroll toStart or Stop

0.0 Meters 18.2

Fault Location Mode

Start: 0.0 mStop: 18.2 m

Units: Meters

99.99

1.00

VSWR

Distance

Scale

Limit

Line

SmoothLow

Cbl Type

Enter a new value

0.0 Meters 10.0

Fault Location Mode

Start: 0.0 mStop: 10.0 m

Units: Meters

99.99

1.00

VSWR

Distance

Scale

Limit

Line

SmoothLow

Cbl Type

Page 51: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 51/124

Page 52: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 52/124

Page 53: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 53/124

Page 54: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 54/124

Bird Site Analyzer 

44

SettingUnits

Scroll toUnits

0.0 Meters 18.2

Fault Location Mode

Min: 1.00Max: 99.99

 Auto ScaleUnits: VSWR

99.99

1.00

VSWR

Distance

Scale

LimitLine

SmoothLow

Cbl Type

Display theunits list 

and select VSWR or 

Return Loss

0.0 Meters 18.2

Fault Location Mode

Min: 1.00Max: 99.99

 Auto ScaleUnits: VSWR

99.99

1.00

VSW

R

Distance

Scale

LimitLine

SmoothLow

Cbl Type

MHz

Units

VSWR

Rtn Loss

Page 55: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 55/124

Fault Location Mode

45

 Activate theselected 

unit 

0.0 Meters 18.2

Fault Location Mode

Distance

Scale

LimitLine

Smooth

Low

Cbl Type

0.0

-60.0

RtnLoss(dB)

Min: -60.0 dB

Max: 0.0 dB

 Auto Scale

Units: Rtn Loss

Page 56: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 56/124

Bird Site Analyzer 

46

Limit Line

The limit line is an option that helps you see a failure.It appears as a horizontal line at the limit line value.

Press fromFault 

LocationMode

Press todisplay the

limit line

value

Enter a new value 0.0 Meters 18.2

Fault Location Mode

99.99

1.00

VSWR

Distance

Scale

LimitLine

SmoothLow

Cbl Type

Limit Line: 1.50

Page 57: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 57/124

Fault Location Mode

47

Limit Test 

Limit Test compares the trace to the limit line.

Test Off — disables the comparison and the pass/failindicator.

Test On — enables the comparison. If all of the trace isbelow the limit value, “PASS” is displayed at thebottom of the screen. If any part of the trace exceedsthe limit value, that portion is displayed in red and“FAIL” is displayed at the bottom of the screen.

Test Audio — as Test On. In addition, the Site Analyzer will beep if any part of the trace exceeds thelimit value.

Press fromFault 

LocationMode

Togglebetween Off, Audio, & On

0.0 Meters 18.2

Fault Location Mode

Calibration: Full

Limit: 1.43

FAIL

1.70

1.00

V

SWR

Save/Recall

 AutoScale

LimitTest On

HOLD

Print

Page 58: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 58/124

Bird Site Analyzer 

48

Marker Adjustment 

Markers indicate VSWR to 0.01, or Return Loss to 0.1dB. The exact values of M1, M2, and the delta marker(difference of M1 and M2) are displayed at the bottomof the screen.

NOTE: If M1 was Active, it becomes ON(displayed) when M2 becomes Active.

Press fromFaul 

LocationMode

Togglebetween Off,

On, and  Active

Togglebetween Off 

and Single

M1 Active

M2On

∆MSingle

0.0 Meters 18.2

Fault Location Mode

Calibration: Full

1.70

1.00

VSWR

M1: 15.3 m

M2: 10.2 m

∆M: 5.1 m

1.40

1.30

0.10

M2

M1

Page 59: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 59/124

Page 60: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 60/124

Page 61: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 61/124

Page 62: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 62/124

Page 63: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 63/124

53

Chapter 6  Save and Recall

This chapter applies to Bird Site Analyzers withfirmware from 1-Nov-2001 or later. If you have anolder firmware version, see “Old Save and Recall” onpage 71.

Traces and setups can be stored in nonvolatilememory, along with descriptive labels and a time-datestamp.

Press fromMeasure

Match or Fault Location

Mode

Save and Recall

Save

Recall

Label

Setup

Delete

1 of 1:

001 015 ALPHA RX02 05-OCT-2001 11:26

Reg Description Date

Page 64: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 64/124

Bird Site Analyzer 

54

Save Trace

Press fromSave and 

Recall 

The trace is

saved 

Save and Recall

Save

Recall

Label

Setup

Delete

2 of 2:

001 015 ALPHA RX02 05-OCT-2001 11:26000 05-OCT-2001 11:26

Reg Description Date

Page 65: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 65/124

Page 66: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 66/124

Page 67: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 67/124

Page 68: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 68/124

Page 69: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 69/124

Save and Recall 

59

SavingLabels

 A complete

label  Save and Recall

Delete

V

W

* Shortcuts off. See config/help for details.

X

 A D G J M P S V Y .

B E H K N Q T W Z ,

C F I L O R U X / -

: @ # [Space]  _ * ( )

QuickText

016 BETA TX01

Save thelabel 

Save and Recall

Save

Recall

Label

Setup

Delete

2 of 2:

001 015 ALPHA RX02 05-OCT-2001 11:26000 016 BETA TX01 05-OCT-2001 11:26

Reg Description Date

Page 70: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 70/124

Bird Site Analyzer 

60

Trace Label Quicktext 

Store commonly used label elements in the Quicktextto speed label entry.

ViewQuicktext

If a Quicktext entry is more than 15 characters long,the complete entry will not be shown in the QuickTextcolumn.

From TraceLabel, scroll 

 past therightmost column to

activateQuicktext 

Save and Recall

Select

 Add toQtext

Delete

Shortcuts off. See config/help for details.

ViewQText

 A D G J M P S V Y .

B E H K N Q T W Z ,

C F I L O R U X / -

: @ # [Space]  _ * ( )

QuickText

Press toview the full 

Quicktext entry 

Save and Recall

Select

 Add toQtext

Delete

Shortcuts off. See config/help for details.

ViewQText

 A D G J M P S V Y .

B E H K N Q T W Z ,

C F I L O R U X / -

: @ # [Space]  _ * ( )

QuickText

016 BETA

016 BETA

[Enter]

Page 71: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 71/124

Page 72: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 72/124

Page 73: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 73/124

Save and Recall 

63

DeleteQuicktext

Scroll to aQuicktext 

entry 

Save and Recall

Select

 Add toQtext

Delete

Shortcuts off. See config/help for details.

ViewQText

 A D G J M P S V Y .

B E H K N Q T W Z ,

C F I L O R U X / -

: @ # [Space]  _ * ( )

QuickText

RXTXBETA ALPHA

Press to

delete theQuicktext entry 

Save and Recall

Select

 Add toQtext

Delete

Shortcuts off. See config/help for details.

ViewQText

 A D G J M P S V Y .

B E H K N Q T W Z ,

C F I L O R U X / -

: @ # [Space]  _ * ( )

QuickText

RXBETA ALPHA

Page 74: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 74/124

Bird Site Analyzer 

64

Trace Label Config 

Label Help Label Help provides instructions for labelling traces.

LabelShortcuts

Enabling shortcuts allow you to select a column bypressing the key corresponding to the column number.When shortcuts are enabled, press the number keyonce to move the column, and twice to enter a number.

Press fromTrace Label 

Press todisplay the

help screen

Save and Recall

Help

DisableShortcuts

Done

 A D G J M P S V Y .

B E H K N Q T W Z ,

C F I L O R U X / -

: @ # [Space]  _ * ( )

QuickText

016 BETA X01T

Use LEFT or RIGHT arrows to select column or Use NUMBER keys to select columnUse SOFTKEYS to enter lettersPress NUMBER keys TWICE to enter digitsUse UP or DOWN arrows to move cursor 

Use ENTER or ESC to exit.

[Enter]

Shortcuts on. See config/help for details.

1 2 3 4 5 6 7 8 9 0

Press fromTrace Label 

Togglebetween

Enable and Disable

Save and Recall

Help

DisableShortcuts

Done Shortcuts on. See config/help for details.

QuickText

1 2 3 4 5 6 7 8 9 0

 A D G J M P S V Y .

B E H K N Q T W Z ,

C F I L O R U X / -

: @ # [Space]  _ * ( )

Page 75: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 75/124

Page 76: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 76/124

Page 77: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 77/124

Page 78: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 78/124

Page 79: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 79/124

Save and Recall 

69

Delete Setup

Press fromSave and 

Recall 

The Setup

menu isdisplayed 

Scroll to thesetup to be

deleted 

Save and Recall

Save

Recall

Traces

Delete

00 824-849 32 05-OCT-2001 09:01a01 780-2500 25 23-OCT-2001 11:26a

Setup Frequency DateTemp

Press todelete the

setup. Pressagain whenasked “AreYou Sure?” 

Save and Recall

Save

Recall

Traces

Delete

00 824-849 32 05-OCT-2001 09:01a

Setup Frequency DateTemp

Page 80: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 80/124

Page 81: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 81/124

Page 82: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 82/124

Bird Site Analyzer 

72

Label and Sort Trace

Press fromSave and 

Recall 

The Label 

menu isdisplayed 

Press todisplay theSite setting 

Enter sitenumber 

Page 83: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 83/124

Page 84: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 84/124

Bird Site Analyzer 

74

Press to sort traces

Press tocomplete trace

labeling 

Page 85: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 85/124

Page 86: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 86/124

Page 87: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 87/124

Page 88: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 88/124

Page 89: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 89/124

Page 90: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 90/124

Page 91: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 91/124

Page 92: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 92/124

Page 93: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 93/124

Page 94: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 94/124

Page 95: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 95/124

Page 96: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 96/124

Page 97: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 97/124

Page 98: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 98/124

Page 99: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 99/124

Measure Power Mode

89

Press to thewarning  Fwd 0.00 mWatts

Offset

12.00

FullScale

Measure Power ModeConfiguration Screen

Recall

Setups

0.00 dB

0.01 Watts

Calibrate5011

WARNINGDo not disconnect sensor until cal is complete.

Wait for calibration

to finish

Fwd 0.00 mWatts

Offset

12.00

FullScale

Measure Power ModeConfiguration Screen

RecallSetups

0.00 dB

0.01 Watts

Calibrate5011

Page 100: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 100/124

Bird Site Analyzer 

90

Page 101: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 101/124

91

Chapter 9 Utilities

These utilities adjust the Bird Site Analyzer’s dateand time, return the unit to default settings, or checkthe printer status.

Press the

Mode key 

Press from

Select Mode

Utility Mode

Rtn To

Defaults

FM Mod

Printer 

System

Model SA-2500A, 780 - 2500 MHz

SN: 00000000

8 Feb 2002

Page 102: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 102/124

Bird Site Analyzer 

92

 Adjust Date and Time

Press todisplay the

systemsettings

Utility Mode

Rtn ToDefaults

FM Mod

Printer 

System

Current Date / Time:12 - - 2001 12:05 pDEC

Model SA-2500A, 780 - 2500 MHz

SN: 00000000

8 Feb 2002

Scroll through thedate & time

Change thedate or time

Utility Mode

Rtn ToDefaults

FM Mod

Printer 

System

Current Date / Time:12 - - 2002 12:05 pFEB

Model SA-2500A, 780 - 2500 MHz

SN: 00000000

8 Feb 2002

Page 103: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 103/124

Utilities

93

Return to Defaults

 All settings will be returned to the factory presets.Saved traces and setups will not be affected. Thisfunction should be used after a unit failure and on firstpower up.

Press toreturn all 

settings tofactory 

 presets

Utility Mode

Rtn ToDefaults

FM Mod

Printer 

System

Return to defaults executed.

Model SA-2500A, 780 - 2500 MHz

SN: 00000000

8 Feb 2002

Page 104: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 104/124

Page 105: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 105/124

Utilities

95

Printer 

The Bird Site Analyzer is compatible all printers thatuse HP PCL Level 3, including most HP printers.

When a printer error occurs, this screen will displayan error message describing the printer problem.

Press todisplay the

 printer status

Utility Mode

Rtn To

Defaults

FM Mod

Printer 

System

Printer: Generic HP Ink Jet Printer Status: OK

Model SA-2500A, 780 - 2500 MHz

SN: 00000000

8 Feb 2002

Page 106: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 106/124

Page 107: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 107/124

97

Chapter 10  Computer Software

The Bird Site Analyzer Software is designed to helpyou use the Site Analyzer more effectively. Thesoftware enables use of a PC for archiving andanalyzing measurement data.

Features

y Multiple Document Interface - allows any numberof trace documents to be open simultaneously.

y Intelligent drag-and-drop automatically convertstraces to a common scale for precise and reliablecomparisons.

y Documents can be viewed in the frequency ordistance domains, or as a Smith chart.

y Data values can be read off the status bar as themouse is moved along the trace.

y Compatible with other cable and antenna testersincluding the Bird AT Series. NOTE: The Bird Site Analyzer and PCTool

software are no longer compatible with trace datafrom the Anritsu Site Master.

y  Automatic cursor calibration maintains accuratereadouts of trace data even if the x-axis changes.

y Supports long file names for easy identification.

Computer Requirements

To install and run the software, your computer systemmust meet the following requirements:

y Windows 95 or latery 486 or better microprocessor running enhanced

mode (66 MHz or better recommended)y 1 MB of free memoryy Hard disk with 3 MB of free spacey 1.44 MB Floppy Drive

NOTE: For more instructions refer to the help filesincluded with the software.

Page 108: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 108/124

Bird Site Analyzer 

98

Page 109: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 109/124

99

Chapter 11 Maintenance

Cleaning 

Only clean the Site Analyzer with a soft cloth

dampened with mild detergent and water. Do not useany other type of cleaning solution.

Charging the Battery 

The internal battery pack is charged while the Site Analyzer is connected to the ac adapter or theautomobile cigarette lighter adapter. Recharging time,

from a full discharge, is approximately 4 hours.

CAUTIONHarsh or abrasive detergents, and some solvents,

can damage the display unit and labels.

Page 110: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 110/124

Bird Site Analyzer 

100

Troubleshooting 

 Any service procedure not covered in this manualshould be referred to an authorized service facility.

Locate the problem, review the possible causes, andperform the action listed. If the problem is notcorrected, give us a call or return the unit for service.

Problem Possible Cause Possible Correction

Unit will not power up Battery pack drained Charge the battery pack.

Battery pack unable tokeep a charge

Replace the battery pack.

 AC adapter is notsecurely connected or isdamaged

Securely connect the acadapter to the unit.

Replace the ac adapter.

No power supplied at thewall receptacle.

Restore power to the wallreceptacle.

Self test fails Error condition Turn the unit off and thenback on. If the problempersists, return the unitfor service.

Date and time appear,hiding the display

Internal error Press Mode, Utility , andthen Escape.

Fault Location trace

appears incorrect

Scale too large Press Auto Scale to make

the scale is small enough.

Incorrect cable loss orvelocity of propagation

Check the cable loss and Vp settings.

Erratic antenna testmeasurements

Bad calibration combo Use a different calibrationcombo.

Soft Key One beepswhen pressed without

actually performingany function.

Context switchingoperations taking place

Wait for screen changes tocomplete before.

Page 111: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 111/124

Maintenance

101

Keys do not respond Unit is “Locked Up” Turn the unit off and thenback on.

Perform a full systeminitialization. Disconnectthe AC adapter, hold downthe Contrast key and turnthe unit off. Turn the unitback on.

Limit line disappears

in Fault LocationMode. The limit valueis valid, the test isperformed andreported, the failingportion of the trace isdrawn in red.

Limit line not drawing Turn the limit line off and

then back on.

Recalled fault locationtrace is invalid.

No fault locationmeasurement made

since last full systeminitialization (holdingdown the Contrast keywhile turning the unitOff).

Change to Measure MatchMode and then back to

Fault Location Mode.

Unit beeps and turnsoff.

Internal error Turn the unit back on andcontinue.

Unit is unable to print.“Error” is displayedafter pressing PRINT .

Printer error Check the error conditionin Utility Mode (Mode,Utility , Printer ). Correctthe error.

Problem Possible Cause Possible Correction

Page 112: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 112/124

Bird Site Analyzer 

102

Battery Replacement 

y Lay the Site Analyzer, display side down, on a cleansurface.

y Remove the four screws and the battery cover. Referto the figure below.

NOTE: Check the direction of the notch in theBattery Cover. It is important to replace the coverthe same way it was removed.

y Disconnect and remove the old battery pack fromthe battery compartment.

NOTE: Do not tear the protective label coveringthe EPROM and Reset access. Hold the wirescoming from the unit while disconnecting thebattery.

y Install the new battery. Make sure the wires arefirmly connected.

y

Place the battery in the battery compartment. Makesure the battery is flat in the compartment, and willnot damage any wires when the cover is installed.

y Replace the battery cover and the screws.

Page 113: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 113/124

Maintenance

103

Unit Reset 

y Lay the Site Analyzer, display side down, on a cleansurface.

y Remove the battery. Follow the instructions in“Battery Replacement”, page 102.

y Remove the label covering the Reset and EPROMaccess. Refer to the figure on the previous page.

y Press the Reset button with a nonconductiveinstrument.

y Place a new label over the Reset and EPROM accessarea.

y Replace the battery and battery cover. Follow thedirections in “Battery Replacement”, page 102.

Page 114: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 114/124

Bird Site Analyzer 

104

Flash ROM Upgrade (SA-2500A Only)

The SA-2500A uses flash-programmable ROM. It isnot necessary to replace the EPROM to upgrade thefirmware.

NOTE: The update process will erase the memoryof the Site Analyzer, including all saved traces andsetups. Use the PC software to save all traces to aPC before updating the flash ROM.

y Install the FlashLoader program on a PC.

y Turn off the Site Analyzer and disconnect theexternal power supply.y Connect the PC to the Site Analyzer’s serial port

with the supplied serial cable.y Run the FlashLoader and click the Begin button.

The status will change to “Waiting to Connect”.y Connect the Site Analyzer to the power supply. The

green LED on the SA will turn on and the FlashUpdater will display “Connected.”

y Select the data file (e.g. 04May2001.sre) and click“Open”.

y Select “Yes” to accept the warning and update theflash, or “No” if you do not want to proceed.

y The update process takes 3 to 5 minutes. After thisthe Site Analyzer will beep several times, the greenpower LED will turn off and the amber chargingLED will start blinking.

Page 115: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 115/124

Maintenance

105

EPROM Replacement 

The EPROM should not need to be replaced by theuser. If the EPROM does ever need to be replaced, itshould only be replaced by qualified service personnel.

NOTE: The Model SA-2500A uses flash-programmable ROM. It is not necessary to replacethe EPROM to upgrade the firmware.

y Make sure the power is turned off and the acadapter is removed from the unit.

y

Lay the Site Analyzer, display side down, on a cleansurface.y Remove the battery. Follow the instructions in

“Battery Replacement”, page 102.y Remove the label covering the Reset and EPROM

access. Refer to the figure below.y Move the battery wires away from the EPROM.y Remove the EPROM with an EPROM removal tool.

y Insert the new EPROM in the socket, keeping it inthe same orientation as the old one.y Put the battery wires back in place.y Place a new label over the Reset and EPROM access.y Replace the battery and battery cover. Follow the

directions in “Battery Replacement”, page 102.

Page 116: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 116/124

Bird Site Analyzer 

106

Customer Service

If you need to return the unit for any reason, contactthe Bird Service Center for a return authorization. Allinstruments returned must be shipped prepaid and tothe attention of Bird Service Center.

ServiceFacility

Bird Service Center

30303 Aurora RoadCleveland (Solon), Ohio 44139-2794Phone: (440) 519-2298Fax: (440) 519-2326

E-mail: [email protected]

SalesFacilities

For the location of the Sales Office nearest you, give usa call or visit our Web site at:

http://www.bird-electronic.com

Parts List 

Part Name Part Number  

Site Analyzer - Complete

806-2000 MHz SA-2000

806-2300 MHz SA-2000A

780-2500 MHz SA-2500A

 AC adapter (15 Vdc output) 5A2436

 Automobile cigarette lighteradapter

5A2238-2

Soft Carrying case 7002A850

9-pin Serial interface cable 5A2264-9MF-10PC interface software kit 7002A844

Instruction manual 920-7002A800

Internal Battery Pack 5A2431

Page 117: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 117/124

Maintenance

107

Specifications

Frequency Characteristics

Frequency Range:Model SA-2000Model SA-2000AModel SA-2500A

806 MHz to 2000 MHz806 MHz to 2300 MHz780 MHz to 2500 MHz

Frequency Resolution: 50 kHz

Frequency Accuracy: ± 150 kHz (75 ppm)

Number of Points: 238Measurement Range and Resolution

Range Resolution

Return Loss: 0.0 to –60.0 dB 0.1 dB

 VSWR: 1.00 to 99.99 0.01

Measurement Uncertainty (after 1 display refresh)Return Loss: Determined graphically from composite of  

42 dB directivity, 1.2 source VSWR, andinstrumentation error. Refer to the figureon page 110.

 VSWR: Calculated from Return Loss

Test Port

Connectors:Impedance:

N, Female normally supplied50 Ohms

Directivity 42 dB, after calibration

Measurement Speed Better than 1 sweep per 4 seconds, testport open, y-axis set to full scale

Immunity to Interfering

Signals

≥ 13 dB interferer at desired

measurement frequency.

Maximum Input Signal(Damage Level)

≥ 22 dBm

Output Power  < 0 dBm

Page 118: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 118/124

Bird Site Analyzer 

108

Distance to Fault (DTF) Measurement

Mode Internal

Resolution [R]

 X-Axis:

Where R=Resolution (meters),εr=Dielectric Constant*, ∆F= frequency

bandwidthY-Axis: 0.1 dB, 0.01 VSWR

Range

X-Axis: Y-Axis:

238 x R0 to –60 dB

Accuracy

X-Axis: Y-Axis:

± 2% of full-scale range with Vp = 1Same as for Return Loss Measurements

Vp Range 0.20 to 1.00, or 1.00 to 99 percent (new specs)

Power Measure Mode

Function: Displays power from Bird power sensors, VSWR alarm and BPM

(specifications determined by sensor)General

Data Storage 300 traces in fundamental data formatstored in non-volatile memory. Tracesmay be recalled and displayed in any of the display formats.

PC/Remote Power Sensor Interface PortConnector:

Protocol:

Female DB-9, compatible with PC serialport.Serial RS-232, 9600 baud, 8 data bits, 1stop bit, no parity, and no handshake.

 R3

8×10

2 εr 

F ∆××

-------------------------------≡

Page 119: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 119/124

Maintenance

109

Printer Interface Port

Connector:

Compatibility:

Female DB-25, compatible with PCparallel port.HP Deskjet printers with PCL Level 3protocol

Power Requirements

Internal:

External DC:External AC:

Lithium-ion rechargeable battery3 hours minimum operating time9 to 16 Vdc90 to 264 Vac @ 45 to 66 Hz

Physical Specifications

Dimensions:Weight:

10.44” x 8.38” x 3.28” (265 x 212 x 83 mm)< 5 lbs. (2.3 Kg)

Environmental Specifications

Operating Temp:Storage Temp:Humidity:

 Altitude:

 –10° to 50°C (14° to 122°F) –40° to 80°C (–40° to 176°F)95% maximum (non-condensing)up to 15,000 feet (4,572 m)

International Standards

EMC: Conforms to: EN 63126-1:1997

Safety: Conforms to: EN 61010-1:1993, with Amendment A2:1995

Calibration

Calibration Cycle: User Defined

RecommendedCalibration Interval:

12 months

*Dielectric Constant - The dielectric constant of the antenna cabledetermines the propagation velocity of the cable, which together with the

frequency range of the match data, determines the maximum distance forwhich the calculation can be done without aliasing errors.

Page 120: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 120/124

Bird Site Analyzer 

110

Measurement Uncertainty (Return Loss after one refresh)

  U  n  c   e r t   a i  n t  y (   d  B )

SiteAntennaTester

Measurem

entUnce

rtainty

MeasuredReturnLoss(dB)

  -    4  -    3 -2-1    0     12    3     4    0 

  -

    5 

-10

  -    1    5 

  -    2    0 

  -    2    5 

Page 121: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 121/124

Maintenance

111

Optional Equipment Available

Precision Open/Short/Load Combination:

Connector Type Part Number  

Male N

Female N

Male 7/16 DIN

Female 7/16 DIN

CAL-MN-B

CAL-FN-B

CAL-ME-B

CAL-FE-B

 Armored (phase stable) Test Cables:

Connector Types Length Part Number  

Male N to Male N

Male N to Male N

Male N to Male N

Male N to Female N

Male N to Female N

Male N to Female N

Male N to Female 7/16 DIN

Male N to Female 7/16 DIN

Male N to Female 7/16 DIN

1.5 meter

3.0 meter

5.0 meter

1.5 meter

3.0 meter

5.0 meter

1.5 meter

3.0 meter

5.0 meter

TC-MNMN-1.5

TC-MNMN-3.0

TC-MNMN-5.0

TC-MNFN-1.5

TC-MNFN-3.0

TC-MNFN-5.0

TC-MNFE-1.5

TC-MNFE-3.0

TC-MNFE-5.0

Precision Adapters:

Connector Types Part Number  

Male N to Male 7/16 DIN

Female N to Male 7/16 DIN

Male N to Female 7/16 DIN

Female N to Female 7/16 DIN

Female N to Female NFemale N to Male N, Right Angle

Female N to Female SMA

Female N to Male SMA

PA-MNME

PA-FNME

PA-MNFE

PA-FNFE

4240-500-14240-500-3

4240-500-4

4240-500-5

Page 122: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 122/124

Bird Site Analyzer 

112

Hard TransitCase

P/N: 7002C870Holds Site Analyzer, standard accessories, calibrationcombo, armored cable assembly, and adapters.

ExternalBattery

Pack

P/N: SA–BATPAK Includes ac adapter and dc power cord.

DirectionalPower 

Sensor 

P/N: 5010Sensor for Thruline power measurement. Requires twoDPM elements.

DPMElements Refer to DPM Element Guide, P/N 871-DPM-019-901,for a complete list of Bird DPM elements.

TerminatingPower 

Sensor 

P/N: 5011Sensor for terminating power measurement.

Terminating Power Sensor Accessories:

Description Part Number  

Female N to Male N Attenuators (RF power range using TPS)

30 dB (10 mW – 10 W) 8353A030–10

40 db (100 mW – 50 W) 8353A040–50

DC Block 5011A035–1

General Purpose Test Cable

Male N to Female N, 1.5 m

TC-MNFN-1.5-G

Calibration Data 5011–CALDATA

Recommended for attenuators, test cables, dc block, andright angle adapter

Page 123: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 123/124

Limited Warranty

 All products manufactured by Seller are warranted to be free from

defects in material and workmanship for a period of two (2) years,unless otherwise specified, from date of shipment and to conform toapplicable specifications, drawings, blueprints and/or samples. Seller’ssole obligation under these warranties shall be to issue credit, repairor replace any item or part thereof which is proved to be other than aswarranted; no allowance shall be made for any labor charges of Buyerfor replacement of parts, adjustment or repairs, or any other work,unless such charges are authorized in advance by Seller.

If Seller’s products are claimed to be defective in material or work-manship or not to conform to specifications, drawings, blueprints and/or samples, Seller shall, upon prompt notice thereof, either examinethe products where they are located or issue shipping instructions forreturn to Seller (transportation-charges prepaid by Buyer). In theevent any of our products are proved to be other than as warranted,transportation costs (cheapest way) to and from Seller’s plant, will beborne by Seller and reimbursement or credit will be made for amountsso expended by Buyer. Every such claim for breach of these warranties

shall be deemed to be waived by Buyer unless made in writing withinten (10) days from the date of discovery of the defect.

The above warranties shall not extend to any products or parts thereof which have been subjected to any misuse or neglect, damaged byaccident, rendered defective by reason of improper installation or bythe performance of repairs or alterations outside of our plant, andshall not apply to any goods or parts thereof furnished by Buyer oracquired from others at Buyer’s request and/or to Buyer’s

specifications. Routine (regularly required) calibration is not coveredunder this limited warranty. In addition, Seller’s warranties do notextend to the failure of tubes, transistors, fuses and batteries, or toother equipment and parts manufactured by others except to theextent of the original manufacturer’s warranty to Seller.

The obligations under the foregoing warranties are limited to theprecise terms thereof. These warranties provide exclusive remedies,expressly in lieu of all other remedies including claims for special or

consequential damages. SELLER NEITHER MAKES NOR ASSUMES ANY OTHER WARRANTY WHATSOEVER, WHETHEREXPRESS, STATUTORY, OR IMPLIED, INCLUDINGWARRANTIES OF MERCHANTABILITY AND FITNESS, AND NOPERSON IS AUTHORIZED TO ASSUME FOR SELLER ANY OBLIGATION OR LIABILITY NOT STRICTLY IN ACCORDANCEWITH THE FOREGOING.

Page 124: Bird SA-2000 Manual

7/27/2019 Bird SA-2000 Manual

http://slidepdf.com/reader/full/bird-sa-2000-manual 124/124

DECLARATION OF CONFORMITY

Manufacturer: Bird Electronic Corporation

30303 Aurora RoadCleveland, Ohio 44139-2794

Products: Site Analyzer

Models: SA-2500A

The undersigned hereby declares, on behalf of Bird Electronic Corporation of 

Cleveland, Ohio, that the above-referenced products, to which this declarationrelates, are in conformance with the provisions of the following standards.

y European Standard EN 55011,1998 - Conducted & Radiated Emissionsy European Standard EN 61000-3-2,1995 - Harmonic Emissionsy European Standard EN 61000-4-2,1995 - ESD Immunityy European Standard EN 61000-4-3,1995 - Radiated RF & EMF Immunityy European Standard EN 61000-4-4,1995 - Fast Transient & Burst Immunityy European Standard EN 61000-4-5,1995 - Surge Immunityy European Standard EN 61000-4-6,1995 - Conducted Immunity

y European Standard EN 61000-4-11,1995 - Voltage Dips & InterruptionsThese standards are in accordance with EMC Directive (89/336/EEC). Electricalequipment for measurement, control and laboratory use, EN 61326-1, 1997.

y European Standard EN 61010-1:1993 - Part 1: General RequirementsIncluding Amendment 2, 1995.

This standard is in accordance with Low Voltage Directive (73/23/EEC), 1973Including Amendment (93/68/EEC) 1993