black-bury underground connectors underground
TRANSCRIPT
EA
EA
EA
www.greaves-usa.comPhone 860-664-4505 • Fax 860-664-4546TOLL FREE 1-800-243-1130 (Outside CT)
PAGE 66
NAEDNUMBER
80432
80433
80434
80435
80436
80438
80453
80454
80455
80456
80458
80474
80476
80478
CATALOGNUMBER
UPP 2-350
UPP 3-350
UPP 4-350
UPP 5-350
UPP 6-350
UPP 8-350
*UPP 3-500
*UPP 4-500
*UPP 5-500
*UPP 6-500
*UPP 8-500
*UPP 4-750
*UPP 6-750
*UPP 8-750
PORTS
2
3
4
5
6
8
3
4
5
6
8
4
6
8
UNDERGROUND
WIRERANGE
350 MCM-#10 STR
500 MCM-#10 STR
750 MCM-#2 AWG
W
41/2
51/8
61/2
H
21/2
3
4
NAEDNUMBER
80350
80360
80370
CATALOGNUMBER
**UPP 1-350
**UPP 1-500
*†UPP 1-750
L
85/8
913/16
101/4
CTNQTY
2
1
1
WIRE RANGE
350MCM - #10STR
500MCM - #10STR
750MCM - #2AWG
DIMENSIONS (IN)
W
13/8
2
33/4
H
23/4
4
61/2
Direct BurialDual-Rated
600V
BLACK-BURY™ UNDERGROUND CONNECTORSSubmersible for direct burial or below-grade boxesFor use in lighting, power distribution, URDMeets ANSI C119.1 and ANSI C119.4 for Class A Heavy duty re-enterable EPDM or TPE black rubber cover Supplied with silicone grease for ease of installation and sealingAluminum connector 6061-T6 alloy Dual-rated connectors prefilled with oxide inhibitor
SPLICE CONNECTORSUse as end-to-end splice or reducerAccommodates wide range of wire sizes within each connector size
UPP SERIES In-line
486D
L
2.73
3.56
4.68
5.81
6.93
9.18
4.56
6.03
7.50
8.98
11.91
7.0
10.4
13.75
HEX
5/16
5/16
3/8
MULTI-CABLE PEDESTAL CONNECTORSUse for multi-cable connections such as pedestal or URDAccommodates a wide range of wire sizes within each connector sizeLarge heavy duty screw-cap pull-tab
UPP SERIES Multi-cable
† UPP1-750 has side-by-side configuration with 4 screws.* UPP 500 and UPP 750 sizes not UL listed.
1.50
0.61
2.50
EST. SHIPPINGWEIGHT(lbs) UNIT
0.61
0.85
1.10
1.83
1.61
2.14
1.38
1.83
2.26
2.71
3.66
4.20
6.40
8.70
EST. SHIPPINGWEIGHT(lbs) UNIT
DIMENSIONS (IN)
*UPP500 and UPP750 sizes not UL Listed.
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
90976_Text_00101_Text 1/6/20 2:17 PM Page 66
CTN
www.greaves-usa.comPhone 860-664-4505 • Fax 860-664-4546TOLL FREE 1-800-243-1130 (Outside CT)
NAED NUMBER
80300
CATALOGNUMBER
UFK 8
QUANTITY
12
UNDERGROUNDDIRECT BURIAL
WIRE RANGE
UF jacketed copper cable #8-14 AWG2/C plus ground or 3/C plus ground
Direct Burial600V CU
UF SPLICE KIT Submersible Splice Kit for UF Underground Feeder CableConvenient - for splice/repair of jacketed Underground Feeder Cable UL Listed - for direct burial splicing of jacketed UF Cable #14 - 8 AWG
- 2/C plus ground, or 3/C plus ground - copper wires only - 600 Volts max
Faster - easier-to-use with only one piece of tubing to shrink Watertight - sealant activated with heat-shrinking process Tough - heavy-wall adhesive-lined heat-shrink tubingUV Resistant - for above-ground applications
Kit ContainsConnector with 4 tubular brass splice couplers (screw type) 8-inch length of heavy-wall adhesive-lined heat-shrinkable tubing Installation instruction and wire stripping guide on package
Display packaged - Card 12 X 5 X 11/2 inches in bagInstallation - Use soft-flame torch or heat gun to shrink tubing and melt adhesive.
UFK SERIES Splice Kit
3.0
EST. SHIPPINGWEIGHT (lbs) UNIT
PAGE 67
90976_Text_00101_Text 1/6/20 2:17 PM Page 67
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
www.greaves-usa.comPhone 860-664-4505 • Fax 860-664-4546TOLL FREE 1-800-243-1130 (Outside CT)
WIRESIZE
#4
#2
#1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000
NAEDNUMBER
80100
80110
80115
80120
80125
80130
80135
80140
80145
80150
80155
80160
80165
80170
80175
CATALOGNUMBER
ASC 4K
ASC 2K
ASC 1K
ASC 10K
ASC 20K
ASC 30K
ASC 40K
ASC 250K
ASC 300K
ASC 350K
ASC 400K
ASC 500K
ASC 600K
ASC 750K
ASC 1000K
COLORCODE
Green
Pink
Gold
Tan
Olive
Ruby
White
Red
Blue
Brown
Green
Pink
Black
Yellow
Brown
DIEINDEX
11/375
12/348
471
296
297
467
17/298
18/324
19/470
20/299
22/472
300
24/473
936
302
SPLICECOVER
R20
R35
R50
R100
UNDERGROUNDIN-LINE WIRE SPLICE KITS
WIRE RANGEMAX. MIN.
350 MCM 6 STR
500 MCM 2 STR
NAEDNUMBER
71005
71010
CATALOGNUMBER
US 350-K
US 500-K
CONNECTORLENGTH (IN)
3
33/16
Dual-Rated600V
Direct Burial
Submersible watertight insulation splice kitsRe-enterable EPDM rubber coverEliminates taping in above-ground installationsEach splice kit contains:
(1) submersible watertight EPDM splice cover(1) capsule of silicone grease(1) electrical splice connector
Splice kit with dual-rated mechanical connectorConnector filled with oxide inhibitor and cappedUse to splice or reduce wire sizeAccepts a wide range of wire sizesDual-rated for aluminum or copper wiring
US-K SERIES
Splice kit with dual-rated compression connectorConnector filled with oxide inhibitor and capped Use to splice specific wire sizeDual-rated for aluminum or copper wiring
ASC-K SERIES
Dual-Rated600V
0.89
0.97
EST. SHIPPINGWEIGHT(lbs) UNIT
0.17
0.17
0.17
0.19
0.26
0.28
0.32
0.32
0.34
0.49
0.52
0.85
0.96
1.00
1.32
EST. SHIPPINGWEIGHT(lbs) UNIT
PAGE 68
90976_Text_00101_Text 1/6/20 2:17 PM Page 68
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
www.greaves-usa.comPhone 860-664-4505 • Fax 860-664-4546TOLL FREE 1-800-243-1130 (Outside CT)
WIRE RANGEMAX CU MAX AL MIN
2/0 1/0 14
350 300 14
500 400 14
1000 1000 2
Submersible watertight insulation splice kitsRe-enterable EPDM rubber coverEliminates taping in above-ground installationsEach splice kit contains:
(1) submersible watertight EPDM splice cover(1) capsule of silicone grease(1) electrical splice connector
Splice kit with copper compression connectorUse to splice specific wire size, copper wire only
C-K SERIES
NAEDNUMBER
80200
80205
80210
80215
CATALOGNUMBER
R 20
R 35
R 50
*R 100
SPLICE CHAMBER DIMENSIONS (IN)
LENGTH DIAMETER
2.75 .68
4.5 .75
4.75 1.05
9.6 1.84
Submersible watertight splice cover onlyRe-enterable EPDM rubber coverEliminates taping in above-ground installationsContains (1) submersible EPDM splice cover
(1) capsule of silicone grease
R SERIES
WIRESIZE
#4
#2
#1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000
NAEDNUMBER
80010
80015
80020
80025
80030
80035
80040
80045
80050
80055
80060
80065
80070
80075
80080
CATALOGNUMBER
C 4K
C 2K
C 1K
C 10K
C 20K
C 30K
C 40K
C 250K
C 300K
C 350K
C 400K
C 500K
C 600K
C 750K
C 1000K
COLORCODE
Gray
Brown
Green
Pink
Black
Orange
Purple
Yellow
White
Red
Blue
Brown
Green
Black
White
DIEINDEX
8/346
10
11/375
12/348
13
14
15
16
17/298
18/324
19/470
20/299
22/472
24/473
27
SPLICECOVER
R20
R35
R50
R100
UNDERGROUND
IN-LINE WIRE SPLICE KITS
Copper wire only600V
600V
Direct Burial
IN-LINE SPLICE COVERS
0.14
0.21
0.29
0.52
0.17
0.19
0.20
0.22
0.24
0.32
0.36
0.39
0.43
0.50
0.61
0.81
1.30
1.45
1.88
EST. SHIPPINGWEIGHT(lbs) UNIT
EST. SHIPPINGWEIGHT(lbs) UNIT
PAGE 69
* Size not UL.
90976_Text_00101_Text 1/6/20 2:17 PM Page 69
www.greaves-usa.comPhone 860-664-4505 • Fax 860-664-4546TOLL FREE 1-800-243-1130 (Outside CT)
UNDERGROUNDHEAT SHRINK TUBINGHEAVY WALL with ADHESIVEBlack cross-linked heavy-wall heat-shrink tubingUse to insulate electrical cable splices in utility/industrial applicationsUse on compression splices (C, SC, SC-FX Series) and adapters (CRK, ND-R Series)Also use to insulate barrels of compression lugsUse for insulation of primary low voltage cablesWithstands severe mechanical and sealing requirements
of URD, submersible, and direct burial installationsProvides strain relief and mechanical protectionResists impact and abrasionSupplied as expanded tubeShrink ratio 3:1, wide range of available diametersShrink temperature: 120°CThermoplastic hot-melt adhesive lining seals to cable jackets
when heatedContinuous operating temperature rating: -55°C to 110°C
Meets UL 486D, CSA C22.2 No. 198.2, ANSI C119.1,Western Underground Guide Numbers 2.4 and 2.5,ICEA and NEMA insulation thickness requirements.
Lengths provide 2-inch seal on both cable jackets when using long barrel compression splice. Other lengths and sizes available.
NAEDNUMBER
41850
41875
41810
41815
41820
41827
CATALOGNUMBER
HWA50-6
HWA75-6
HWA100-9
HWA150-9
HWA200-9
HWA275-12
PKGQTY
8
6
4
3
3
1
NOMINALSIZE
1/2
3/4
1
11/2
2
23/4
WIRE SIZEMAX MIN
LENGTHPIECE (IN)
6
6
9
9
9
12
#6
#2
3/0
350
500
1000
#8
#6
#1
2/0
250
600
INSIDE DIAD d
.51
.75
1.1
1.5
2.0
2.7
.16
.24
.35
.47
.63
.87
HWA SERIES
INSTALLATION1. Place the tube over one of the cable-ends before splicing.2. Install the electrical splice.3. Center the tube over the splice so a minimum of 2 inches of tubing will seal to each cable jacket.4. With a soft-flame torch, begin at the center and heat slowly around the radius, moving progressively to each
end. When heated to shrink temperature, the tubing shrinks and conforms to the splice, and the adhesive melts and seals to the splice and cable jackets. Heat so adhesive forms a bead around each end. Do not overheat, which can scorch and damage the tubing.
CTN
CTN
CTN
CTN
CTN
EA
.3
.4
.6
.63
1.0
.5
EST. SHIPPINGWEIGHT(lbs) UNIT
PAGE 70
D d
As supplied
Before shrinking
After shrinking
1000V110°C
Before shrinking
Aftershrinking