blackwood fire company use of the scott rit pak. scott rit pak

11
Blackwood Fire Company Blackwood Fire Company Use of the Scott Use of the Scott RIT PAK RIT PAK

Upload: pierce-wilcox

Post on 30-Dec-2015

219 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK

Blackwood Fire CompanyBlackwood Fire Company

Use of the ScottUse of the Scott

RIT PAKRIT PAK

Page 2: Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK

Scott RIT PAKScott RIT PAK

Page 3: Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK

FeaturesFeatures

The harness is streamlined and has no The harness is streamlined and has no strapsstrapsThe unit is equipped with a single stage, The unit is equipped with a single stage, hose mounted pressure reducerhose mounted pressure reducerThe unit does not have an integrated The unit does not have an integrated PASS alarmPASS alarmThe unit does not have a low pressure The unit does not have a low pressure warning alarm. The member assigned to warning alarm. The member assigned to the bag must monitor cylinder level.the bag must monitor cylinder level.

Page 4: Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK

Contents and LocationContents and Location

Stored in Cab of R-84Stored in Cab of R-84

Equipped with:Equipped with:– 1 30 minute SCBA cylinder (a 60 minute cylinder 1 30 minute SCBA cylinder (a 60 minute cylinder

will be provided later this year)will be provided later this year)– 1 Spare SCBA mask1 Spare SCBA mask– 1 Spare mask regulator / buddy breather hose1 Spare mask regulator / buddy breather hose– 1 hose assembly with pressure reducer and adapter 1 hose assembly with pressure reducer and adapter

fittingsfittings– Small rescue hand tools and webbingSmall rescue hand tools and webbing

Page 5: Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK

ContentsContents

Page 6: Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK

StagingStaging

Assign a member of FAST to emergency Assign a member of FAST to emergency airair

Turn the cylinder ON and check pressureTurn the cylinder ON and check pressure

Check contents and ensure locations are Check contents and ensure locations are well knownwell known

Any firefighter trapped, missing or reported Any firefighter trapped, missing or reported in trouble will be considered low on air.in trouble will be considered low on air.

Page 7: Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK

Airline Fitting Airline Fitting Utilize the Hansen fitting to supply air through the air line whip, directly to his mask

(only if the pack is properly equipped, all of ours are)

Page 8: Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK

Buddy Breather ConnectionBuddy Breather Connection

Page 9: Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK

Change the Regulator or Mask Change the Regulator or Mask CompletelyCompletely

Page 10: Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK

Alternate MethodsAlternate Methods

TL-84 FAST BAGTL-84 FAST BAG

Page 11: Blackwood Fire Company Use of the Scott RIT PAK. Scott RIT PAK

Use the Rope Bag to Store a Use the Rope Bag to Store a Standard SCBAStandard SCBA