blood glucose monitoring system - rossmax.com

1
Advanced GDH-FAD Technology The GDH-FAD test strips can eliminate interference from oxygen variations and non-glucose sugar such as maltose and galactose, providing you with the most reliable and accurate results. GDH-FAD Enzyme Affected by Oxygen Affected by Galactose Affected by Maltose GDH-FAD GDH-PQQ GOD No No Yes No Yes No No Yes No 1 1 2 2 3 3 Insert HS200 test strip Apply blood sample Result in 5 seconds Blood Glucose Monitoring System prevention • monitoring • therapy • professional Model: HS200 www.rossmax.com OBM_Epaper_HS200_EN_ver2036 Storage and Transportation Condition -20°C~50°C, < 90% RH 700~1060 hPa • Advanced GDH- FAD Technology (applicable for wide HCT range: 0-70%) • Auto Coding • 5 seconds Fast Test Time • Measures with Small Blood Sample • Insufficient Blood Sample Volume Detection • 7/14/30 Days Average for blood glucose patterns tracking • Stores up to 500 Results • Easy-slide Strip Ejector • Error Indicator • Bluetooth ® low energy Technology (optional) • PC Link (optional) • Alternative Sites Testing Approved (Cap optional) Patent Nos: US 10,004,443 B2 US 9,763,612 B2 I563980, I563979 ZL 2014 1 0140609.9 ZL 2014 1 0142578.0 Other patents pending 7/14/30 days

Upload: others

Post on 05-Oct-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Blood Glucose Monitoring System - rossmax.com

Advanced GDH-FAD TechnologyThe GDH-FAD test strips can eliminate interference from oxygen variations and non-glucose sugar such as maltose and galactose, providing you with the most reliable and accurate results. GDH-FAD

Enzyme

Affected by Oxygen

Affected by Galactose

Affected by Maltose

GDH-FAD GDH-PQQ GOD

No No Yes

No Yes No

No Yes No

11

22

33

Insert HS200 test strip

Apply blood sample

Result in 5 seconds

Blood Glucose Monitoring System

prevention • monitoring • therapy • professional

Model: HS200

www.rossmax.comOBM_Epaper_HS200_EN_ver2036

Storage and Transportation Condition-20°C~50°C, < 90% RH

700~1060 hPa

• Advanced GDH- FAD Technology (applicable for wide HCT range: 0-70%)

• Auto Coding• 5 seconds Fast Test Time • Measures with Small Blood Sample• Insufficient Blood Sample Volume Detection• 7/14/30 Days Average for blood glucose patterns

tracking• Stores up to 500 Results• Easy-slide Strip Ejector• Error Indicator• Bluetooth® low energy Technology (optional)• PC Link (optional)• Alternative Sites Testing Approved (Cap optional)

Patent Nos: US 10,004,443 B2US 9,763,612 B2I563980, I563979ZL 2014 1 0140609.9ZL 2014 1 0142578.0Other patents pending

7/14/30days