blow gun - smc (thaimodel piping length: 2 m coil tube tube diameter s coupler model ø6 ø6 ø8...

16
Air cost: 3 Yen/m 3 Air-flow volume is determined by the effective area, not the nozzle diameter. A large effective area means that the blow gun can be used with less pressure for the required job. This means it is possible to use with less air consumption. In addition, the environmentally friendly low noise nozzle is also available. Produces less noise by dividing the air-blow slit. 80 dB or less Low-noise nozzle Series VMG VMG 506 570 650 3,038 3,420 3,936 6,077 6,840 7,871 ø2 ø2.5 ø3 30 6 6 211 237.5 273.3 + 763 +1,794 + ¥2,289 + ¥5,382 Energy saving Noise reduction For example Blow Gun Reduction of annum is possible. 2,000 m 3 per Reduction of annum is possible. 2,000 m 3 per Conventional model A Conventional model B Pressure loss 1 % or less Pressure loss 1 % or less (Nozzle diameter: ø2.5) CAT.ES50-20C Nozzle diameter 1 month 6 months 12 months Air consumption (m 3 ) Cost Air consumption (m 3 ) Amount difference (12 months) Effective area (mm 2 ) Consumption flow (dm 3 /min (ANR))

Upload: others

Post on 01-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

∗ Air cost: 3 Yen/m3

Air-flow volume is determined by theeffective area, not the nozzle diameter.

A large effective area means that the blow gun can beused with less pressure for the required job.

This means it is possible to use with less air consumption.In addition, the environmentally friendly low noise nozzle

is also available.

Produces less noiseby dividing the

air-blow slit.

80 dB or lessLow-noise nozzle

Series VMG

VMG 506

570

650

3,038

3,420

3,936

6,0776,8407,871

ø2

ø2.5

ø3

30

6

6

211

237.5

273.3

+ 763+1,794

+ ¥2,289+ ¥5,382

Energysaving

Noisereduction

Forexample

Blow Gun

Reduction of

annum is possible.2,000 m3 per

Reduction of

annum is possible.2,000 m3 per

Conventional model A Conventional model B

Pressure loss 1% or less

Pressure loss 1% or less

(Nozzle diameter: ø

2.5)

CAT.ES50-20C

Nozzlediameter 1 month 6 months 12 months Air consumption (m3) Cost

Air consumption (m3) Amount difference (12 months)Effectivearea (mm2)

Consumption flow

(dm3/min (ANR))

Page 2: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

Valve Construction and Pressure Loss

Comparison by Switchover

Straighter flowing fluid “improves pressure loss.”

PAT.PEND

Series VMG

Pressure Loss

0 0.2 0.4 0.6 0.8 1

Supply pressure (MPa)

Pre

ssur

e lo

ss (

MP

a)

0 30 60 90 120 150 1800

4,000

6,000

8,000

10,000

12,000

14,000

16,000∗ Air cost: 3 Yen/m3

0

1,000

2,000

3,000

4,000

5,000

6,000

7,000

8,000

9,000

0 30 60 90 120

150

180

210

240

270

300

330

360

Air consumption comparison (per blow gun)

Approx. 2,000 m3

differencein 365 days

Approx. 1,000 m3

differencein 365 days

VMGConventional model AConventional model B

� VMG11W-02-03Effective area 30 mm2

Nozzle diameter ø2

� Conventional model AEffective area 6 mm2

Nozzle diameter ø2.5

� Conventional model BEffective area 6 mm2

Nozzle diameter ø3

• Workpiece impact pressure: 0.01 MPa• Workpiece distance: 100 mm• Piping: TU0805-3 m• Blow time: 30 s/times• Blow frequency: 10 times/h• Working hours: 16 hrs/day

0

0.1

0.05

0.15

0.2

0.25

0.3 VMG(Nozzle diameter: ø2.5)

Pressure loss: 0.005 MPa or less with 0.5 MPa

Model

Condition

Cos

t (Y

en)

Days

Air

cons

umpt

ion

(m3 )

Days

Total cost comparison (Blow gun purchase price + Air cost)

Breakeven withconventional model B

Breakeven withconventional model A

Conventional construction

Energy savingvalve construction

Balance-poppet valve construction

Conventional model AConventional model B

Features 1

Page 3: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

Example of Air Blow Improvement

ø2.5

Filterregulator

S couplerCoiltube

Nozzleø2.5

Effective arearatio

1 : 1.33

S2S0 to S1

Effective arearatio

3.3 : 1

S2S0 to S1

When using the air gun, energy-saving measures are rarely taken.

ø3

Pressure loss

Large

Nozzleø3

Pressure loss

Small

After improvementBefore improvement

Reduced pressure loss for the whole system Reduced air consumption

95%95%

Reduced bymore than Reduced bymore than

After improvementBefore improvement

Effective area ratio (S0 to S1 : S2)

Regulator pressure

Air gun pressure (idling)

Outlet pressure

Air consumption

TCU0805 coil tube

Conventional model

ø3

6.8 mm2

6 mm2

6.3 mm2

1 : 1.33

0.3 MPa

0.255 MPa

0.177 MPa

210.7 dm3/min (ANR)

0.123 MPa

0.078 MPa

Piping

Air gun

Nozzle size

Piping (S0)

Air gun (S1)

Nozzle (S2)

Whole system

Air gun single unit

After reviewing the air-blow job, changing the fittings, tube and blow gun create a larger effective area.

10%10%

Operatingequipment

Effectivearea

Effective area ratio (S0 to S1 : S2)

Regulator pressure

Blow gun pressure (idling)

Outlet pressure

Air consumption

TCU1065�-1-20-X8 coil tube

Series VMG1

ø2.5

14.8 mm2

30 mm2

4.4 mm2

3.3: 1

0.26 MPa

0.254 MPa

0.252 MPa

186.6 dm3/min (ANR)

0.008 MPa

0.002 MPa

Piping

Blow gun

Nozzle size

Piping (S0)

Blow gun (S1)

Nozzle (S2)

Whole system

Blow gun single unit

Operatingequipment

Reduced bymore than

Reduced bymore than

Features 2

Reduced bymore than

Reduced bymore than

Beforeimprovement

Afterimprovement

Pressureloss

Effectivearea

Pressureloss

Page 4: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

Operability, Safety, Environmentally

Dark blue White

Piping direction

Bottom

Top

Body color

White

Dark blue

Piping type

With S coupler plug

Rc, NPT, G 1/4, 3/8

NozzlesHand-fit Design34 Types in Nozzle VariationHand-fit Design34 Types in Nozzle VariationHand-fit Design34 Types in Nozzle Variation

Low-noise nozzleMono-porous nozzle (ø2) 90 to 100 dBø1 x 4 low noise nozzle 80 dB or lessNote) Supply pressure: 0.5 MPa

Measured at a 45 degree angle according to JIS B 8379

∗ Achieving lower-noise by dividing the air blow slit.

∗ Powerful, and economical.

Male thread nozzle

∗ Making use of Bernoulli effect andachieving high-efficiency.

High-efficiency nozzle

∗ Secures large power even at a greaterdistance from a workpiece.

Copper extension nozzle

Resin:PBT

Seals:NBR

Nozzle:Brass

Metal:Aluminum

alloyStainless

steel Recyclable

When using this product even at a high pressure the same gripping force is required as for a lower pressure due to the unique balance-poppet construction.

When using this product even at a high pressure the same gripping force is required as for a lower pressure due to the unique balance-poppet construction.

Resin parts are labeled with their material composition for easy identification. In addition, all components are separable according to their material composition.

Resin parts are labeled with their material composition for easy identification. In addition, all components are separable according to their material composition.

Shock-resistant resin is used in the main body. No cracks, breaks or other damage occurred in a drop test from a 2-meter height or in a human stomp test.

Shock-resistant resin is used in the main body. No cracks, breaks or other damage occurred in a drop test from a 2-meter height or in a human stomp test.

Features 3

Components can be separated for recycling.

Not affected by supply pressure,Assured operability

Use of shock-resistant resin

Page 5: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

Air blowAir blow

70%

� First, check your blow gun.Most blow guns in use have an effective area of about 6 mm2.

� Furthermore, energy can be saved using a comprehensive air-blow system.

etc.

Lowerpressure

loss

Use withlower

pressure.

Lowerair con-

sumption

Reducedpower con-sumption

Largeeffective

area

Reducedcost

If a blow gun with alarger effective area is used.

Air leakage measures Improvement of pressure loss High-efficiency

S coupler achieves a smooth flow with less lossUrethane coil tube

Male thread nozzle

High efficiency nozzle

Low noise nozzlewith male thread

Copper extension nozzle

Blow gunPiping length: 1 m

Coil tube

Tube diameter

S coupler

Model

Piping length: 2 mCoil tube

Tube diameter

S coupler

Model

ø6

ø6

ø8

ø10

ø6

ø6

ø8

ø6

ø10

ø8

ø10

ø6

ø8

ø6

ø8

KK4S-06�KK4S-06�KK4S-08�KK4S-10�KK4S-06�KK4S-06�KK4S-08�KK4S-06�KK4S-10�KK4S-08�KK4S-12�KK4S-06�KK4S-08�KK4S-06�KK4S-08�

ø6

ø8

ø10

ø12

ø6

ø8

ø10

ø6

ø12

ø10

ø12

ø8

ø10

ø8

ø10

KK4S-06�KK4S-08�KK4S-10�KK4S-12�KK4S-06�KK4S-08�KK4S-10�KK4S-06�KK4S-12�KK4S-10�KK4S-12�KK4S-08�KK4S-10�KK4S-08�KK4S-10�

ø1

ø1.5

ø2

ø2.5

ø1

ø1.5

ø2

ø0.75 x 4

ø0.9 x 8

ø1 x 4

ø1.1 x 8

ø1.5-300 mm

ø2-300 mm

ø1.5-600 mm

ø2-600 mm

Nozzle type Nozzle diameter

Example of air consumptioninside the factory

“Why not use wasted air?”

Air leakage20%

Actuation

10%The power consumption for air (compressor) consumed in the factory is accounting for 20%. An estimated 70% of total air con-sumption is used for air blowing.Why not review your air con-sumption?

But the SMC model has

an of .

etc.

Selection Table for Blow Gun Nozzle Diameter and Tube ∗ Recommended system in accordance with the nozzle type

Features 4

Page 6: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

Blow gun

VMG 1

Series

1 03 01W

Standard type

Male thread nozzle

High efficiency nozzle

Low noise nozzlewith male thread

Copper Note)

extensionnozzle

Specifications

Fluid

Operating pressure range

Proof pressure

Ambient and fluid temperature

Effective area

Port size

Piping entry

Nozzle port size

Weight

Operational force (when the valve is fully open)

Air

0 to 1.0 MPa

1.5 MPa

�5 to 60�C (No freezing)

30 mm2 (without nozzle)

Rc, NPT, G 1/4, 3/8

Rc 1/4

180 g

7 N

Bottom Top

Note) One piece of H06-02 self-align fitting is attached.When a copper extension nozzle is ordered separately, a self-align fitting will also be required for connection. Order one with the above part number in addition to the nozzle.

Note) In the case of a type with an S coupler plug, specify no symbol (Rc) for the piping connection type. The size is Rc 1/4.

Resin body lever type1

Body colorWhite

Dark blue

WBU

Piping entryBottom

Top

12

Piping connection typeRc

NPT

G

Nil

NF Connection size

Size and part no.Piping connection system

Screw-in type

With S coupler plug Note)

1/4

3/8

KK4P-02MS

020311

NozzleType Nozzle model

Without nozzle

KN-R02-100

KN-R02-150

KN-R02-200

KN-R02-250

KNH-R02-100

KNH-R02-150

KNH-R02-200

KNS-R02-075-4

KNS-R02-090-8

KNS-R02-100-4

KNS-R02-110-8

KNL3-06-150

KNL3-06-200

KNL6-06-150

KNL6-06-200

Nozzle size

ø1

ø1.5

ø2

ø2.5

ø1

ø1.5

ø2

ø0.75 x 4

ø0.9 x 8

ø1 x 4

ø1.1 x 8

ø1.5

ø2

ø1.5

ø2

Nil010203041112132122232431323334

Length300 mm

Length600 mm

Port size

Plug part no.

1

Series VMGBlow Gun

How to Order

Page 7: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

1234567891011121314151617181920

Body L

Body R

Main valve

Valve guide

Nozzle holder

Port

Elbow

Cover

Ring

Arm L

Arm R

Spring

Main valve seal

Lever

Piping (bottom)

O-ring

O-ring

Parallel pin

Cross recessed round head screw

Hexagon nut

Material

Chromated

Anodized

Anodized

∗Only for VMG11�

PBT

PBT

PBT

Aluminium alloy

Aluminium alloy

Aluminium alloy

PBT

PBT

PBT

PBT

PBT

Stainless steel

HNBR

PBT

POM

NBR

NBR

Stainless steel

Stainless steel

Stainless steel

Note

Component Partsi

y

ureq w

o

t

!3!7!2

!5

!6!1 !0

!8

@0 !9

!4

600

500

400

300

200

100

00.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

KN-R02-250

KN-R02-200

KN-R02-100

400

350

300

250

200

150

100

50

0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

KNH-R02-200

KNH-R02-150

KNH-R02-100

400

350

300

250

200

150

100

50

0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

KNL3-06-200

KNL3-06-150

KNL6-06-200

KNL6-06-150

900

800

700

600

500

400

300

200

100

0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

KNS-R02-110-8

KNS-R02-090-8

KNS-R02-100-4

KNS-R02-075-4

Supply pressure [MPa] Supply pressure [MPa]

Flo

w r

ate

[l/m

in (

AN

R)]

Supply pressure [MPa]

Flo

w r

ate

[l/m

in (

AN

R)]

Supply pressure [MPa]

Flo

w r

ate

[l/m

in (

AN

R)]

Male thread nozzle High efficiency nozzle

Low noise nozzle with male thread Copper extension nozzle

KN-R02-150

Note) Grease is used on rubber and sliding sections.

Note) Values when the main valve is fully open.

DescriptionNo.

Construction

Flow Characteristics

Flo

w r

ate

[l/m

in (

AN

R)]

2

Blow Gun Series VMG

Page 8: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

23

23

A

172.

5

34.2

30

147

117.5

102

A

30

156

117.5

102

Rc, NPT, G 1/4, 3/8

Rc, NPT, G 1/4, 3/8

Rc 1/4

Width across flats 22

Nozzle

Rc 1/4

Type Nozzle model

Male thread nozzle

High efficiency nozzle

Nozzle size A Note)

34.2

Not

e)

Note) Reference dimensions after installation

(mm)

Nozzle

KN-R02-100

KN-R02-150

KN-R02-200

KN-R02-250

KNH-R02-100

KNH-R02-150

KNH-R02-200

ø1

ø1.5

ø2

ø2.5

ø1

ø1.5

ø2

23.4

23

22.5

22.1

44

44

44

Type Nozzle model

Low noise nozzle with male thread

Copper extension nozzle (with self-align fitting H06-02)

Nozzle size A Note)

(mm)

KNS-R02-075-4

KNS-R02-090-8

KNS-R02-100-4

KNS-R02-110-8

KNL3-06-150

KNL3-06-200

KNL6-06-150

KNL6-06-200

ø0.75 x 4

ø0.9 x 8

ø1 x 4

ø1.1 x 8

ø1.5

ø2

ø1.5

ø2

12

12

12

12

305.3

305.3

605.3

605.3

Dimensions

S coupler plug mounting

Not

e)

Width across flats 22

VMG12/Piping entry: Top

S coupler plug mounting

3

VMG11/Piping entry: Bottom

Series VMG

Page 9: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

øD

L1

A

L1

øD

H1

Connection thread

øD

2

A

L1

Connection threadH1

AL1

øD

H1

Connection thread

KNL3-06-150A02KNL3-06-200A02KNL6-06-150A02KNL6-06-200A02

KNL3-06-150 (1 pc.)KNL3-06-200 (1 pc.)KNL6-06-150 (1 pc.)KNL6-06-200 (1 pc.)

Description

H06-02-X2 (1 pc.)H06-02-X2 (1 pc.)H06-02-X2 (1 pc.)H06-02-X2 (1 pc.)

(mm)

KN-R02-100KN-R02-150KN-R02-200KN-R02-250

ø1ø1.5ø2ø2.5

R 1/4R 1/4R 1/4R 1/4

14141414

31.431 30.530.1

25.425 24.524.1

∗ Reference dimensions after R thread installation.

L1 A∗H1

(mm)

KNH-R02-100KNH-R02-150KNH-R02-200

ø1ø1.5ø2

R 1/4R 1/4R 1/4

141414

525252

464646

∗ Reference dimensions after R thread installation.

L1 A∗H1

Low noise nozzle with male thread: KNS (mm)

KNS-R02-075-4KNS-R02-090-8KNS-R02-100-4KNS-R02-110-8

ø0.75 x 4ø0.9 x 8ø1 x 4ø1.1 x 8

R 1/4R 1/4R 1/4R 1/4

14141414

20202020

14141414

Model

∗ Reference dimensions after R thread installation.

Nozzle sizeD

Connectionthread L1 A∗Width across flats

H1

Copper extension nozzle: KNL (mm)

KNL3-06-150KNL3-06-200KNL6-06-150KNL6-06-200

ø1.5ø2ø1.5ø2

300300600600

ø6ø6ø6ø6

Model Outside diameterNozzle size

D L1

Nozzle Self-align fittings

Male thread nozzle: KN

Dimensions: Nozzle/Series KN

ModelNozzle size

DConnection

threadWidth across flats

High efficiency nozzle: KNH

ModelNozzle size

DConnection

threadWidth across flats

Out

side

diam

eter

Note) When a copper extension nozzle is ordered separately, a self-align fitting will also be required for connection with the blow gun. Order one with the following part number in addition to the nozzle.

Self-align fittings (For copper extension nozzle connection)

Male connectorH06-02-X2

Set no.

4

Blow Gun Series VMG

Page 10: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

Back page 1

Safety InstructionsThese safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)∗1), and other safety regulations.∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.

ISO 4413: Hydraulic fluid power – General rules relating to systems.IEC 60204-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements)ISO 10218-1: Manipulating industrial robots - Safety.etc.

1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications.Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.

2. Only personnel with appropriate training should operate machinery and equipment.The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling

or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the

power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully.

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct

sunlight.2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military,

medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.

3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical

protective function, and periodical checks to confirm proper operation.

Warning

Caution:

Danger :

Warning:

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

Page 11: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

Back page 2

Safety Instructions

Limited warranty and Disclaimer/Compliance Requirements The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance Requirements”.Read and accept them before using the product.

1. The product is provided for use in manufacturing industries.The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.

Caution

Limited warranty and Disclaimer

1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.∗2)

Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.

2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.

3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products.

∗2) Vacuum pads are excluded from this 1 year warranty.A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.

Compliance Requirements1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or

any other weapon is strictly prohibited.

2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.

Page 12: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

Male thread

R 1/4

R 3/8

Tightening torque N⋅m

12 to 14

22 to 24

PortSpanner

Wrapping direction

Pipe tape

Expose approx. 2 threads

Back page 3

Nozzle tightening torque range 12 to 14 N �m

Nozzle holderSpanner

Insufficient tightening may cause loosening of the nozzle.

1. Do not apply the blow gun to flammable, explosive or toxic substances such as gas, fuel gas or refrigerant. Such substances may exude from inside the blow gun.

1. Install a stop valve on the supply pressure side of the blow gun to enable emergency shut off in case of unexpected leakage or damage.

2. When installing a nozzle on the blow gun, wrap seal tape around the threads of the nozzle.

3. When installing the nozzle, secure the nozzle holder of the blow gun by applying a spanner of 22 mm width across flats to the two chamfered surfaces of the holder without applying force to the body. Then tighten the nozzle with force within the following torque ranges. As a guideline, it is equivalent to 2 to 3 additional turns with a tool after manual tightening.

1. Confirm the specifications.The products in this catalog are designed to be used in compressed air systems only. If the products are used in an environment where pressure or temperature is out of the specified range, damage and/or malfunction may result. Do not use under such conditions.

Selection

Mounting

Warning

Warning

1. Confirm the model, type and size before installation.Also make sure that there is no scratches, gouges or cracks on the product.

2. Before pipingBefore piping, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.

Piping

Caution

Caution

3. Wrapping of pipe tapeWhen screwing together pipes and fittings, etc., be certain that chips from the pipe threads and sealing material do not get inside the piping. Also, when the pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads.

Piping

Caution

4. When tightening the threads, secure the nozzle holder of the blow gun by applying a spanner of 22 mm width across flats to the two chamfered surfaces of the holder without applying force to the body. Then tighten the nozzle with torque specified in the table below. As a guideline, it is equivalent to 2 to 3 additional turns using a tool after manual tightening.Be careful that tightening with torque beyond the ranges in the table below may cause damage to the body.

5. Allow extra length when connecting the tube to accommodate changes in tube length due to pressure.

6. Make sure that no twisting, turning or tensile force or moment load is applied to the port or tube. It may cause the fittings to fracture or the tubing to crush, explode or come loose.

7. Do not abrade, entangle or scratch the tubing. It may cause the tubing to crush, explode or come loose.

1. Use clean air.Do not use compressed air which includes chemicals, synthetic oils containing organic solvents, salt or corrosive gases, etc., as it can cause damage or malfunction.

Air Supply

Warning

1. Do not lubricate the product.It may contaminate or damage the target object.

Lubrication

Warning

Series VMGSpecific Product Precautions 1Be sure to read this before handling.

Page 13: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

Hook

Back page 4

Air Supply

9. When the blow gun is being used or stored, make sure that no twisting, turning or tensile force or moment load is applied to the port or tube. It may cause the fittings to fracture or the tubing to crush, explode or come loose.

Series VMGSpecific Product Precautions 2Be sure to read this before handling.

1. Install air filters.Install air filters at the upstream side of blow gun. The filtration de-gree should be 5 µm or finer.

2. Install an after-cooler, air dryer or water separator, etc.Air excessive drainage may cause malfunction of blow gun and contaminate or damage the target object. To prevent this, install an after-cooler, air dryer or water separator, etc.

Caution

1. Do not use in an atmosphere of corrosive gases, chemicals, sea water, water or water vapor or in an environment where such substances may adhere.

2. Provide shading in an environment where the product is exposed to the sunlight.

3. Do not use in an environment where a heat source is at a close distance.

4. Do not use in an environment where static electricity is a problem. It may cause malfunction or failure of the system. Consult with SMC for use in such an environment.

5. Do not use in an environment where spatters are generated. There is danger of fires caused by spattering. Contact SMC for use in such an environment.

6. Do not use in an environment where the product is exposed to cutting oil, lubricant oil or coolant oil. Contact SMC for use in an environment where the product is exposed to such liquid as cutting oil, lubricant oil or coolant oil.

Operating Environment

Warning

1. In periodical inspections, check the follow-ing items and replace the parts if necessary.a) Scratches, gouges, abrasion, corrosionb) Air leakagec) Twisting, crushing and turning of connected tubesd) Hardening, deterioration and softening of connected tubese) Loosening of the nozzle

2. When removing the product, first stop the pressure supply, exhaust compressed air in the piping and confirm the condition of atmospheric release.

3. Do not disassemble or remodel the body of the product.

Maintenance

Caution

1. To prevent lurching of the nozzle due to air pressure, confirm that the nozzle is not loosened or rattling by pulling it by hand before operation.

2. Be sure to wear safety goggles to protect yourself from splashed substances.

3. Do not direct the tip of the nozzle at the face or other parts of a human body. It may cause danger to personnel.

4. Do not use the product to clean or remove toxic substances or chemicals.

5. Do not drop, step on or hit the product. It may cause damage to the product.

6. Do not use the product to disturb public order or public hygiene.

7. This product is not a toy.8. After blowing, be sure to hang the product

on a hook, etc.If leaving the product in a dusty place, particles will enter the product and may result in a malfunction.

Handling

Warning

Page 14: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main
Page 15: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main
Page 16: Blow Gun - SMC (ThaiModel Piping length: 2 m Coil tube Tube diameter S coupler Model ø6 ø6 ø8 ø10 ø6 ø6 ø8 ø6 ø 10 ø8 ø10 ø6 ... Elbow Cover Ring Arm L Arm R Spring Main

Record of changes

Edition B

Edition C

· Related devices Series KK/KKH S coupler, changed to the model change products.· High efficiency nozzle data listed. JR

· Best Pneumatics No.1 (Pages 1889 to 1899) extracted. NS

Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPANPhone: 03-5207-8249 Fax: 03-5298-5362URL http://www.smcworld.com© 2009 SMC Corporation All Rights Reserved

Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

1st printing GZ printing NS 12200SZ Printed in Japan.D-SZ

This catalog is printed on recycled paper with concern for the global environment.

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.