DELAWARE VETERANS HOME DELAWARE VETERANS HOME DELAWARE VETERANS HOME LIST OF SHEETS Sheet No. Sheet Title G-001 COVER SHEET G-002 ABBREVIATIONS / SYMBOLS / GENERAL NOTES A-101 FLOOR PLAN & DEMOLITION PLAN A-121 REFLECTED CEILING PLAN AND FINISH PLAN A-401 FIXTURE PLAN AND DOORS A-501 INTERIOR ELEVATIONS AND CASEWORK A-601 EXTERIOR WINDOWS AND DETAILS P-001 PLUMBING LEGENDS AND FIXTURE SCHEDULES P-101 PLUMBING SANITARY PIPING PLANS P-102 PLUMBING DOMESTIC WATER PIPING PLANS P-501 PLUMBING RISER DIAGRAMS AND DETAILS M-001 MECHANICAL LEGENDS, SYMBOLS, AND ABBREVIATIONS M-101 MECHANICAL FLOOR PLANS AND DETAILS M-102 MECHANICAL FIRST FLOOR PLAN MEDICAL GAS E-001 ELECTRICAL LEGENDS AND FIXTURE SCHEDULES E-101 ELECTRICAL DEMOLITION AND NEW WORK FLOOR PLANS E-401 ELECTRICAL DETAILS & SCHEDULES FP-101 FIRE PROTECTION PLANS © 2018 BERNARDON PC Sheet Number: Sheet Title: Project Number: Contact: Drawn: Reviewed: Owner: Revision/Issue: Project: William E. Holloway, AIA Bernardon PC C:\Revit Locals\8347_11-17 DE Vets Blue Wing Bathing Suite_dquaintance.rvt 9/18/2018 1:39: 45 PM G-001 DJQ 8347.11-17 COVER SHEET Delaware Veterans Home BLUE WING BATHING SUITE RENOVATION 100 Delaware Veterans Boulevard Milford, DE 19963 RET Bill Holloway, AIA STATE OF DELAWARE OMB - DFM Thomas Collins Building 540 S. DuPont Highway Dover, DE 19901 2 AREA MAP N 1 LOCATION MAP 3 SITE MAP N STATE OF DELAWARE OFFICE OF MANAGEMENT AND BUDGET OMB/DFM CONTRACT # MJ2009000004 BLUE WING BATHING SUITE RENOVATION AT 100 DELAWARE VETERANS BOULEVARD N DIVISION OF FACILITY MANAGEMENT MILFORD, DE 19963 DELAWARE VETERANS HOME 0 9/18/18 Issued for Bid

Upload: others

Post on 05-Jun-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet

DELAWARE VETERANS HOME

DELAWARE VETERANS HOME

DELAWARE VETERANS HOMELIST OF SHEETSSheet No. Sheet Title

G-001 COVER SHEET

G-002 ABBREVIATIONS / SYMBOLS / GENERAL NOTES

A-101 FLOOR PLAN & DEMOLITION PLAN

A-121 REFLECTED CEILING PLAN AND FINISH PLAN

A-401 FIXTURE PLAN AND DOORS

A-501 INTERIOR ELEVATIONS AND CASEWORK

A-601 EXTERIOR WINDOWS AND DETAILS

P-001 PLUMBING LEGENDS AND FIXTURE SCHEDULES

P-101 PLUMBING SANITARY PIPING PLANS

P-102 PLUMBING DOMESTIC WATER PIPING PLANS

P-501 PLUMBING RISER DIAGRAMS AND DETAILS

M-001 MECHANICAL LEGENDS, SYMBOLS, AND ABBREVIATIONS

M-101 MECHANICAL FLOOR PLANS AND DETAILS

M-102 MECHANICAL FIRST FLOOR PLAN MEDICAL GAS

E-001 ELECTRICAL LEGENDS AND FIXTURE SCHEDULES

E-101 ELECTRICAL DEMOLITION AND NEW WORK FLOOR PLANS

E-401 ELECTRICAL DETAILS & SCHEDULES

FP-101 FIRE PROTECTION PLANS

© 2018 BERNARDON PC

Sheet Number:

Sheet Title:

Project Number:

Contact:

Drawn:

Reviewed:

Owner:

Revision/Issue:

Project:

William E. Holloway, AIA

Bernardon PC

C:\

Rev

it L

oca

ls\8

347

_1

1-1

7 D

E V

ets

Blu

e W

ing B

athin

g S

uit

e_d

quai

nta

nce

.rvt

9/1

8/2

018 1

:39

: 45 P

M

G-001

DJQ

8347.11-17

COVER SHEET

Delaware Veterans HomeBLUE WING BATHINGSUITE RENOVATION100 Delaware VeteransBoulevardMilford, DE 19963

RET

Bill Holloway, AIA

STATE OF DELAWAREOMB - DFMThomas Collins Building540 S. DuPont HighwayDover, DE 19901

2AREA MAP

N

1LOCATION MAP

3SITE MAP

N

STATE OF DELAWARE

OFFICE OF MANAGEMENT AND BUDGET

OMB/DFM CONTRACT # MJ2009000004

BLUE WING BATHING SUITE RENOVATION

AT

100 DELAWARE VETERANS BOULEVARD

N

DIVISION OF FACILITY MANAGEMENT

MILFORD, DE 19963

DELAWARE VETERANS HOME

0 9/18/18 Issued for Bid

Page 2: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet

© 2018 BERNARDON PC

Sheet Number:

Sheet Title:

Project Number:

Contact:

Drawn:

Reviewed:

Owner:

Revision/Issue:

Project:

William E. Holloway, AIA

Bernardon PC

C:\

Rev

it L

oca

ls\8

347

_1

1-1

7 D

E V

ets

Blu

e W

ing B

athin

g S

uit

e_d

quai

nta

nce

.rvt

9/1

8/2

018 1

:39

: 46 P

M

G-002

DJQ

8347.11-17

ABBREVIATIONS /SYMBOLS /GENERAL NOTES

Delaware Veterans HomeBLUE WING BATHINGSUITE RENOVATION100 Delaware VeteransBoulevardMilford, DE 19963

RET

Bill Holloway, AIA

STATE OF DELAWAREOMB - DFMThomas Collins Building540 S. DuPont HighwayDover, DE 19901

1. Applicable Code(s) & Regulations For This Project.

State: 2012 IBC (International Building Code With Amendments)2012 IEBC (International Existing Building Code)

ICC A117.1-2009 (Accessible and Useable Buildings and Facilities)Delaware State Fire Prevention Regulation 20122012 Edition of Life Safety NFPA 101

Federal: 2010 ADA (Standards for Accessible Design)

2. Occupancy Use Classification(s): I-2 Institutional (Existing)3. Construction Type(s) / Classification(s): II-B / II-000 (Assumed Existing)

4. Project Description: Renovation of existing bedroom into new bathing suite

5. Date(s) of Original Construction: 2005

6. Authority Having Jurisdiction: City of Milford DE

KEY INFORMATION

CL

N

ARCHITECTURAL STANDARD ABBREVIATIONSALT AlternateAPC Acoustic Panel Ceiling

APPROX ApproximateARCH Architectural

BD Board

BITUM BituminousBLDG BuildingBLKG Blocking

BM BeamBRG BearingBSMT BasementBUR Built-up Roofing

CAB CabinetCB Catch Basin

CCTV Closed Circuit TelevisionCEM CementCF/CI Contractor Furnished/

Contractor InstalledCF/OI Contractor Furnished/

Owner InstalledCI Cast Iron

CIP Cast-in-placeCJ Control JointCLG Ceiling

CL ClosetCLR ClearCMU Concrete Masonry UnitCNTR Center

COL ColumnCONC ConcreteCONST Construction

CONT ContinuousCORR CorridorCPT CarpetCRS Course(s)

CT Ceramic Tile

DBL Double

DEPT DepartmentDET DetailDF Drinking FountainDIA Diameter

DIM DimensionDN DownDS DownspoutDWG Drawing

E EastEA Each

EIFS Exterior Insulation and Finish System

EJ Expansion JointEL Elevation

ELEC ElectricalELEV ElevatorEMER Emergency

EOS Edge of SlabEPDM Ethylene Propylene Diene MonomerEPS Expanded Polystyrene

InsulationEQ EqualEQUIP Equipment

ETR Existing to RemainEWC Electric Water CoolerEXIST ExistingEXP Expansion

EXT Exterior

FA Fire Alarm

FD Floor DrainFDN FoundationFE Fire ExtinguisherFEC Fire Extinguisher Cabinet

FHC Fire Hose CabinetFIN FinishFIXT FixtureFLR Floor

FLUOR Fluorescent

FOC Face Of ConcreteFOF Face Of Finish

FOM Face Of MasonryFOS Face Of StudsFPBI Foam Plastic Board

Insulation

FRJS Fire Resistive Joint SystemFRP Fiberglass Reinforced

Plastic

FRT Fire Retardant TreatedFT Foot/FeetFTG FootingFURR Furring

GA GaugeGALV Galvanized

GFCI Ground Fault Circuit Interrupter

GL GlassGR Grade

GYP BD Gypsum Board

HB Hose Bibb

HC Hollow CoreHDW HardwareHDWD HardwoodHM Hollow Metal

HORIZ HorizontalHP High PointHR Hour

HSS Hollow Structural Section (Tube Steel)

HT Height

ID Inside DiameterIN Inch(es)INS InsulationINT Interior

JAN JanitorJST Joist

JT Joint

LAB LaboratoryLAM Laminate

LAV LavatoryLP Low PointLTTR Long Term Thermal

ResistanceLVL Laminated Veneer Lumber

MAX Maximum

MDF Medium Density Fiberboard

MECH Mechanical

MEP Mechanical, Electrical, Plumbing

MFR ManufacturerMIN Minimum

MISC MiscellaneousMO Masonry OpeningMOD BIT Modified Bituminous

MT Marble ThresholdMTD MountedMTL MetalMUL Mullion

N NorthN/A Not Applicable

NIC Not In ContractNO NumberNOM NominalNTS Not To Scale

OC On CenterOCC Occupant(s)

OD Outside DiameterOF/CI Owner Furnished/

Contractor InstalledOF/OI Owner Furnished/

Owner InstalledOH OverheadOPG OpeningOPP Opposite

OSB Oriented Strand Board

PCC Precast ConcretePCFS Perimeter Fire

Containment SystemPL PlatePLAM Plastic LaminatePLYWD Plywood

PR PairPSF Pounds Per Square

Foot

PSL Parallel Strand Lumber

PSI Pounds Per Square Inch

PT Pressure TreatedPTD PaintedPVMT Pavement

R Riser or RadiusRD Roof DrainREF Reference

REFR RefrigeratorREINF ReinforcedREQD Required

RES ResilientRM RoomRO Rough OpeningRWC Rain Water

Conductor

S South

SC Solid CoreSCHED ScheduleSECT SectionSF Square Feet

SFRM Spray Fire Resistive MaterialsSIM SimilarSPEC Specification

SPM Single Ply MembraneSQ SquareSS Stainless Steel

STD StandardSTL SteelSTOR StorageSTRUCT Structure

SUSP SuspendedSYM Symmetrical

T TreadT&G Tongue & GrooveTEL TelephoneTHK Thick

TOC Top Of ConcreteTOF Top Of FinishTOM Top Of Masonry

TOS Top Of SteelTPO Thermoplastic

Polyolefin TYP Typical

UNO Unless Noted Otherwise

VCT Vinyl Composition Tile

VERT Vertical

VEST VestibuleVIF Verify In Field

W WestW/ WithW/O WithoutWC Water Closet

WD WoodWH Water HeaterWIC Walk-in-Closet

WP Working PointWRB Water-Resistive

BarrierWSCT Wainscot

WT WeightWWF Welded Wire Fabric

XPS Extruded Polystyrene

Insulation

4A-401

1A-201

1

A-40

1

SYMBOLS

W: Wall FinishB: BaseF: Floor Finish

Diameter

Center Line

Accessory / Fixture Type

Number Or Pound

Revision Number

And

At

Room NameRoom Number

Interior Elevation Number

Elevation or Section

Number Working Point Or

Control Point

Sheet Number

Detail NumberSheet Number

Sheet Number

New Column

Door Number

Partition Type

Window Type

Magnetic North

Plan North

Existing Column

Ceiling TypeCeiling Height

Casework Finish Dimension to Face of

Material

1A

1

1

101 #

ø

1

&

@

OFFICE

A

APC-19'-0"

P-1WB-1CPT-1

SS-11

WBF

C

101

MATERIALS

Gypsum Board

Plywood

Wood - Continuous Lumber

Wood - Finish

Wood - Blocking Steel

Stone

Concrete Masonry Unit

Porous Fill, Stone Or

Gravel

Insulation - Rigid

Glass In Elevation

Insulation - Batt, Blanket

Or Loose

Brick

Concrete

Earth

Architect: Consultant to Owner

BERNARDON123 Justison Street, Suite 101 Wilmington, DE 19801

T 302-622-9550 F 302-622-9554

Contact:

Email:

Bill Holloway, [email protected]

MEP Engineer: Consultant to Architect

315 South Chapel StreetNewark, DE 197115

T: 302-738-7172 F 302-738-7175

DEDC INC.

Contact:

Email:

John Farina, [email protected]

0 9/18/18 Issued for Bid

Page 3: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet

B U I L D I N G C E N T E R , M A S T E R W O R K P O I N T 0 , 0

FLOOR PLAN GENERAL NOTES1. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO ROUGH MATERIAL (FACE

OF FRAMING, MASONRY, AND/OR CONCRETE.)2. REFER TO THE TYPICAL RESTROOM ACCESSORY MOUNTING HEIGHTS DIAGRAM

FOR FIXTURE AND ACCESSORY MOUNTING HEIGHTS AND OTHER ADA REQUIREMENTS.

3. COORDINATE APPLIED SURFACE MATERIAL WITH FINISHES. CRITICAL CLEAR DIMENSIONS NOTED ARE TO MATERIAL FINISH.

4. INSTALL MOISTURE RESISTANT BOARD IN FRAMED PARTITIONS IN ALL WET LOCATIONS.

5. PARTITIONS ABOVE OPENINGS SHALL BE THE SAME AS THE PARTITIONS BESIDE THE OPENING.

6. PROVIDE WOOD BLOCKING IN NEW AND EXISTING FRAMED PARTITIONS FOR FIXTURES, ACCESSORIES AND THE INSTALLATIONS OF GRAB BARS AS PER MANUFACTURERS RECOMMENDATIONS.

7. SELECT ACOUSTICAL BATT INSULATION THICKNESS TO FILL STUD CAVITY WITHOUT COMPRESSING.

SEMI-PRIVATEUNIT

1059

BATHING SUITE1058

LOUNGE

1057

CLOSET1078

STOR1058C

TOILET1058A

CORRIDOR1075

STOR

1058B

ALIGN

4'-0"

1058A

1058B

2'-5"

5'-0"

ALIGN 135°

3'-6 3/8"

135°

7'-7 3/4" 2'-5"

1'-5 1/4"

2'-2"

1A

1A

1A

1

1

1

1A

A-501

1

A-501

543

2

1A-601

2A-6011058C

12" M

IN CLR

1'-0"

NEW CARD READER

BATHING TUB RECOMMENDED CLEARANCE

2'-0"

SEMI-PRIVATEUNIT

1060

CLEAN ROOM

1077

1078

3'-6"

FD

ALIGN

1

1058

8'-0 5/8"

BATHING SUITE1058 D

F

A

A

B

C

B

C

D

A

A

A

A

D

F

G

TOILET1058A

SEMI-PRIVATEUNIT

1059

CORRIDOR1075

CLOSET1078

LOUNGE1057

E H

E H

6'-0" 1'-1"

A

E

J

E H J

E H J

J

DEMOLITION DEFINITIONS• REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE

OF THEM OFF-SITE UNLESS INDICATED TO BE REMOVED AND SALVAGED OR REMOVED AND REINSTALLED.

• REMOVE AND SALVAGE: CAREFULLY DETACH FROM EXISTING CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE, AND DELIVER TO OWNER.

• REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING CONSTRUCTION, PREPARE FOR REUSE, AND REINSTALL WHERE INDICATED.

• EXISTING TO REMAIN: EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT TO BE PERMANENTLY REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE REMOVED, REMOVED AND SALVAGED, OR REMOVED AND REINSTALLED.

DEMOLITION KEYNOTES

A REMOVE EXISTING WALL

B

C

REMOVE EXISTING PLUMBING FIXTURE AND ASSOCIATED CASEWORK. COORDINATE WITH PLUMBING DRAWINGS.

REMOVE EXISTING PLUMBING FIXTURE AND ASSOCIATED ACCESORIES. REINSTALL RELEVANT ACCESSORIES. COORDINATE WITH PLUMBING DRAWINGS.

D REMOVE EXISTING DOOR AND FRAME

E REMOVE EXISTING FLOOR FINISH AND BASE

F REMOVE EXISTING CLOSET ROD AND SHELF

G REMOVE EXISTING EXTERIOR WINDOW, SILL, AND TREATMENT

1. REMOVE ITEMS DESIGNATED BY DASHED LINES. VERIFY CONDITIONS PRIOR TO COMMENCEMENT OF WORK.

2. AREAS AND PARTITIONS NOT DASHED OR NOTED TO BE REMOVED SHALL STAY INTACT. REFER TO FLOOR PLAN FOR MORE INFORMATION. PATCH AND REPAIR ADJACENT AREAS AS REQUIRED AFTER DEMOLITION IN ACCORDANCE WITH RENOVATIONS.

3. PROVIDE INTERIOR AND EXTERIOR SHORING, BRACING, OR OTHER SUPPORT TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE OF ELEMENTS TO BE DEMOLISHED AND ADJACENT WORK TO REMAIN.

4. PROVIDE TEMPORARY WEATHER PROTECTION DURING INTERVAL BETWEEN DEMOLITION AND INSTALLATION OF NEW CONSTRUCTION TO ENSURE THAT WATER LEAKAGE DOES NOT DAMAGE THE STRUCTURE.

5. UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS.

6. EXISTING SERVICES/SYSTEMS TO BE REMOVED, RELOCATED OR ABANDONED: LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF INDICATED UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEM SERVING AREAS TO BE SELECTIVELY DEMOLISHED.

7. VERIFY THAT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING SELECTIVE DEMOLITION OPERATIONS.

8. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF MECHANICAL AND ELECTRICAL DEMOLITION.

9. DEMOLISH CONCRETE AND MASONRY IN SMALL SECTIONS. CUT CONCRETE AND MASONRY AT JUNCTURES WITH OTHER ELEMENTS TO REMAIN USING POWER-DRIVEN MASONRY SAW OR HAND TOOLS; DO NOT USE POWER-DRIVEN IMPACT TOOLS.

10. REMOVE FROM BUILDING SITE DEBRIS, TRASH, AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. TRANSPORT AND LEGALLY DISPOSE OF OFF SITE.

11. IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN THE WORK. IF MATERIALS SUSPECTED OF BEING HAZARDOUS ARE ENCOUNTERED, DO NOT DISTURB. IMMEDIATELY NOTIFY ARCHITECT AND OWNER. HAZARDOUS MATERIALS WILL BE REMOVED BY OWNER UNDER SEPARATE CONTRACT.

12. BURNING OF REMOVED MATERIALS IS NOT PERMITTED ON PROJECT SITE.13. STORE ITEMS TO BE RELOCATED AND PROTECT FROM DAMAGE.14. COORDINATE DEMOLITION WITH BUILDING OWNER AND OTHER TRADES. CONFIRM

EXTENT, TIMING, AND ITEMS TO BE SALVAGED BY BUILDING OWNER.

DEMOLITION GENERAL NOTES

H REMOVE EXISTING LIGHTING FIXTURES ABOVE. COORDINATE EXTENT WITH REFLECTED CEILING PLAN.

J REMOVE EXISTING GYP BD AS REQUIRED TO INSTALL NEW BLOCKING.

BASE - SEE FINISH SCHEDULE

CEILING - SEE REFLECTED CEILING PLAN

UNDERSIDE OF FLOOR OR ROOF STRUCTURE

FLOOR STRUCTURE

4 7/8"

ACOUSTICAL BATT INSULATION (WALL TYPE 1A ONLY)

CONTINUOUS METAL STUD BOTTOM TRACK

CONTINUOUS DEEP LEG DEFLECTION TRACK

3 5/8" METAL STUDS AT 16" OCPLAN

HEAD

BASE

5/8" GYP BD

AREA OF WORK

© 2018 BERNARDON PC

Sheet Number:

Sheet Title:

Project Number:

Contact:

Drawn:

Reviewed:

Owner:

Revision/Issue:

Project:

William E. Holloway, AIA

Bernardon PC

C:\

Rev

it L

oca

ls\8

347

_1

1-1

7 D

E V

ets

Blu

e W

ing B

athin

g S

uit

e_d

quai

nta

nce

.rvt

9/1

8/2

018 1

:39

: 37 P

M

A-101

DJQ

8347.11-17

FLOOR PLAN &DEMOLITION PLAN

Delaware Veterans HomeBLUE WING BATHINGSUITE RENOVATION100 Delaware VeteransBoulevardMilford, DE 19963

RET

Bill Holloway, AIA

STATE OF DELAWAREOMB - DFMThomas Collins Building540 S. DuPont HighwayDover, DE 19901

0' 2' 8'4'

N

SCALE: 1/4" = 1'-0"1NEW WORK FLOOR PLAN

N

SCALE: 1/4" = 1'-0"2DEMOLITION PLAN

0' 2' 8'4'

SCALE: 3/4" = 1'-0"3PARTITION TYPES 1 & 1A

0" 6" 2'1'

KEY PLAN

N

0 9/18/18 Issued for Bid

Page 4: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet

B U I L D I N G C E N T E R , M A S T E R W O R K P O I N T 0 , 0

REFLECTED CEILING PLAN GENERAL NOTES

1. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING AND EXIT SIGNS.2. ALL DIMENSIONS ARE FROM FACE OF FINISHED SURFACE, UNLESS NOTED

OTHERWISE.3. CEILING PANELS SHALL BE CENTERED WITHIN THE ROOM, UNLESS NOTED

OTHERWISE.4. FIXTURES SHALL BE CENTERED WITHIN SOFFITS AND CEILING GRID UNLESS

NOTED OTHERWISE.5. IF A DISCREPANCY BETWEEN THE REFLECTED CEILING PLANS AND THE

MECHANICAL, ELECTRICAL, PLUMBING, AND/OR FIRE PROTECTION / ALARM PLANS OCCURS, THE ENGINEERS DRAWING TAKE PRECEDENCE. CONSULT WITH ARCHITECT IF THE LIGHTING LAYOUTS SHOWN ON THE REFLECTED CEILING PLAN ARE IMPACTED.

6. PATCH AND REPAIR EXISTING GYP BD CEILING AS REQUIRED.

1. ALL FLOOR SURFACES SHALL BE PREPARED IN A MANNER APPROPRIATE TO RECEIVE NEW MATERIAL DESIGNATED. PATCH AND LEVEL WITH LATEX COMPOUND APPROVED BY FLOORING MANUFACTURER.

2. FLOORING CONTRACTOR SHALL PROVIDE ALL REQUIRED TRANSITION TRIM BETWEEN CHANGES IN FLOORING MATERIAL. SUBMIT SAMPLES FOR DESIGNER'S REVIEW PRIOR TO INSTALLATION.

3. FLOORING TRANSITIONS OCCURRING AT DOORWAYS SHALL BE LOCATED UNDER THE CENTER OF THE DOOR WHEN IN CLOSED POSITION, UNLESS NOTED OTHERWISE.

4. ALL GYP BD SHALL BE PAINTED WITH LATEX SATIN FINISH.5. ALL INTERIOR HOLLOW METAL DOOR FRAMES SHALL BE PAINTED P-2, SEMI-

GLOSS LATEX ENAMEL.6. FLOOR FINISHES AND BASE TO CONTINUE UNDER ALL CASEWORK.

FINISH GENERAL NOTES

PAINT:

P-1: WALL: MFR: SHERWIN WILLIAMS; COLOR: SW 6147 PANDA WHITE; FINISH: SEMI-GLOSS; CONTACT: SHELLY A. BEEKLEY, [email protected], T (215) 806-3579

P-2: DOOR FRAME: MFR: SHERWIN WILLIAMS; COLOR: SW 7037 BALANCED BEIGE P-2; FINISH: SEMI-GLOSS; CONTACT: SHELLY A. BEEKLEY, [email protected], T (215) 806-3579

FINISH SELECTIONS

FINISH PLAN LEGEND

X-1C

BASE FINISHX-1B

WALL FINISHX-1W

FLOOR FINISHX-1F

CABINET FINISHCAB

X-1C CASEWORK FINISH

X-1C COUNTER FINISHCTR

INDICATES START/STOP POINT OF FLOORING FINISHES

WALL TILE:

WT-1: MFR: GARDEN STATE TILE; STYLE: CROSSVILLE; MATERIAL: PORCELAIN; PATTERN: MARCA CORONA; COLOR: PLANET WHITE; SIZE: 12x24; FINISH: HONED; CONTACT: JENNY WAWRZYNIAK, [email protected], T (717) 360-1100

WT-2: ACCENT TILE: MFR: BEST TILE; STYLE: WOODLAND COLLECTION; PATTERN:CYPRESS; COLOR: RANDOM BRICK MOSAIC 250353; SIZE: .625 X .625 MOSAIC; CONTACT: DEBORAH COSTANTINO, [email protected], T (732) 739-5501

WT-3: MFR: GARDEN STATE TILE, STONE PARTNERSHIP INC; STYLE: LIMESTONE PENCIL TRIM; COLOR: CLAIR; FINISH: HONED; CONTACT: JENNY WAWRZYNIAK, [email protected], T (717) 360-1100

FLOOR TILE:

FT-1: MFR: GARDEN STATE TILE; STYLE: CROSSVILLE; MATERIAL: PORCELAIN; PATTERN: MARCA CORONA; COLOR: PLANET WHITE; SIZE: 12x24; FINISH: HONED; CONTACT: JENNY WAWRZYNIAK, [email protected], T (717) 360-1100

FT-2: MFR: GARDEN STATE TILE; STYLE: CROSSVILLE; MATERIAL: PORCELAIN; PATTERN: FLOW; COLOR: AMBER; SIZE: 2x2 MOSAIC; FINISH: NATURAL; CONTACT: JENNY WAWRZYNIAK, [email protected], T (717) 360-1100

BASE:

B-1: MFR: GARDEN STATE TILE; STYLE: CROSSVILLE; MATERIAL: PORCELAIN; PATTERN: MARCA CORONA; COLOR: PLANET WHITE; SIZE: 4x24; FINISH: HONED; CONTACT: JENNY WAWRZYNIAK, [email protected], T (717) 360-1100

SOLID SURFACE:

SS-1: MFR: CORIAN; STYLE: RESIN; COLOR: LINEN; EDGE: EASED;CONTACT: MARIA DIPIETRO, [email protected], T (610) 275-4199

PLASTIC LAMINATE:

PL-1: MFR: LAB DESIGNS; STYLE: HONEY CAYMAN; COLOR: PT004 (VERTICAL USE ONLY); CONTACT: MICHELE WENGER, [email protected]

PRIVACY CURTAIN AND TRACK:

PC-1: MFR: EYKON; STYLE: DAYBREAK; COLOR: CBD-02 BLUE GREEN; WIDTH: 102", INCLUDING 20-22" INTEGRAL MESH; CONTECNTS: 100% POLYESTER; REPEAT: 55" HORITONZONTAL REPEAT 5" VERTICAL REPEAT: BORDER PRINT, 12" HORIZONTAL REPEAT; FIRE TEST: PASSES NFPA 701; TRACK: HCC; TRACK STYLE #11 FOR TUB AREA. ALUMINUM TRACK W/ 3 CARRIERS PER FOOT; ONE STRAP END, ONE STOP W/ PULL OUT.; CONTACT: JANET CACKOVIC, [email protected], T (610) 731-5359

P-3: ACCENT WALL: MFR: SHERWIN WILLIAMS; COLOR: SW 6493 EBBTIDE; FINISH: SEMI-GLOSS; CONTACT: SHELLY A. BEEKLEY, [email protected], T (215) 806-3579

FW-1: MFR: SCHLUTER; STYLE: DITRA-HEAT-TB; NOTE: SEE ELECTRICAL DRAWINGS FOR DETAILS AND EXTENT; CONTACT: JENNY WAWRZYNIAK, [email protected], T (717) 360-1100

FLOOR WARMING:

GYPSUM BOARD CEILING (NEW)

REFLECTED CEILING PLAN LEGEND

LED DOWNLIGHT FIXTURE - DIMMINGA

SURFACE MOUNTED LED CEILING LIGHT FIXTUREB

SUPPLY DIFFUSER (SEE MECHANICAL DRAWINGS)

RETURN REGISTER (SEE MECHANICAL DRAWINGS)

EXHAUST FAN (SEE MECHANICAL DRAWINGS)

WALL SCONCEC

RADIANT HEAT LAMP FIXTURED

SPRINKLER HEAD (SEE FIRE PROTECTION DRAWINGS)

3 5/8" METAL FRAMING AT 16" OC

5/8" GYP BD

EXISTING GYP BD CEILING

BO BULKHEAD+8'-0"

EXIST CEILING+9'-0" VIF

EXISTING PARTITION

SEE REFLECTED CEILING PLAN

WT-1

WT-2

WT-1

WT-3

5"4'-11"

TO FINISH FLOOR

EXIST9'-0"

GYP BD8'-0"

GYP BD8'-0"

GYP BD8'-0"

BATHING SUITE

1058

TOILET1058A

CORRIDOR1075

SEMI-PRIVATEUNIT

1059

CLOSET1078

LOUNGE1057

STOR1058B

STOR1058C

GYP BD8'-0"

EXIST9'-0"

3A-121

3A-121

B

A

A

A

D

A

A

A

A

EQ EQ

1'-0"

EQEQEQ

EQ

EQ EQ

EQEQ

EQ EQ

EQ EQ

3'-10"

2'-0"

EQEQ

EQ EQ

6'-10"

3'-5"

AA

6'-6" 6'-6" 3'-3"

A

C

C

C C10'-0" 1'-0"

EQEQ

EQ EQA

A

2'-8"

EQEQ

EXIST

BATHING SUITE1058

STOR1058C

STOR

1058B

TOILET1058A

CORRIDOR1075

SEMI-PRIVATEUNIT

1059

CLOSET1078

LOUNGE1057

A-501

1

A-501

543

2

EXIST TERRAZZO

W P-1W WT-1B B-1F FT-1F FW-1

PC PC-1

W P-3W WT-1B B-1F FT-1F FW-1

FT-1

W WT-1W WT-2W WT-3B B-1F FT-2F FW-1

W P-1B B-1F FT-1F FW-1

W WT-1

FT-2 FT-1END TILE AT ALL OUTSIDE CORNERS WITH SCHULTER JOLLY TRIM (POLISHED CHROME ANODIZED ALUMINUM (ACG) )

EXTENT OF WALL TILE WT-1 TO 7'-2" AFF. INSIDE TRIM AT BASE AND CORNERS -SCHULTER DILEX-HK (COLOR: SAND PEBBLE)

W P-1B B-1F FT-1F FW-1

EXTENT OF WALL TILE WT-1 TO 7'-2" AFF. INSIDE TRIM AT BASE AND CORNERS -SCHULTER DILEX-HK (COLOR: SAND PEBBLE)

W WT-1

W P-3W WT-1

W WT-1

W WT-1

W WT-1

W WT-1

W WT-1

ALL FINISHES IN CLOSET 1078 TO BE COORDINATED WITH OWNER

PC PC-1

AREA OF WORK

© 2018 BERNARDON PC

Sheet Number:

Sheet Title:

Project Number:

Contact:

Drawn:

Reviewed:

Owner:

Revision/Issue:

Project:

William E. Holloway, AIA

Bernardon PC

C:\

Rev

it L

oca

ls\8

347

_1

1-1

7 D

E V

ets

Blu

e W

ing B

athin

g S

uit

e_d

quai

nta

nce

.rvt

9/1

8/2

018 1

:39

: 40 P

M

A-121

DJQ

8347.11-17

REFLECTEDCEILING PLAN ANDFINISH PLAN

Delaware Veterans HomeBLUE WING BATHINGSUITE RENOVATION100 Delaware VeteransBoulevardMilford, DE 19963

RET

Bill Holloway, AIA

STATE OF DELAWAREOMB - DFMThomas Collins Building540 S. DuPont HighwayDover, DE 19901

0' 2' 8'4' 0' 2' 8'4'

SCALE: 1 1/2" = 1'-0"3BULKHEAD DETAIL

0" 3" 6" 1' SCALE: 1" = 1'-0"4TILE ACCENT DETAIL

0" 6" 2'1'

N

SCALE: 1/4" = 1'-0"1REFLECTED CEILING PLAN

N

SCALE: 1/4" = 1'-0"2FINISH PLAN KEY PLAN

N

0 9/18/18 Issued for Bid

Page 5: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet

B U I L D I N G C E N T E R , M A S T E R W O R K P O I N T 0 , 0

1. REFER TO THE TYPICAL RESTROOM ACCESSORY MOUNTING HEIGHTS DIAGRAM FOR FIXTURE AND ACCESSORY MOUNTING HEIGHTS AND OTHER ADA REQUIREMENTS.

2. SEE PLUMBING DRAWINGS FOR FIXTURE SIZE AND DESCRIPTIONS. COORDINATE FIXTURE SIZE WITH REQUIRED CLEAR DIMENSIONS AND CLEAR FLOOR SPACE.

3. PROVIDE WOOD BLOCKING IN NEW AND EXISTING PARTITIONS FOR FIXTURES, ACCESSORIES, AND THE INSTALLATIONS OF GRAB BARS AS PER MANUFACTURERS RECOMMENDATIONS.

4. COORDINATE CRITICAL CLEAR DIMENSIONS WITH WALL FINISHES. 5. INTERIOR DIMENSIONS ARE FROM FACE OF STUD OR MASONRY FOR NEW

PARTITIONS (UNO.) DIMENSIONS ARE FROM FACE OF FINISH FOR EXISTING PARTITIONS.

6. INSTALL MOISTURE RESISTANT BOARD IN ALL WET LOCATIONS.7. PROVIDE PIPE INSULATION AT ALL EXPOSED PIPES.8. COORDINATE RECESSED ACCESSORY LOCATIONS WITH MEP DRAWINGS TO AVOID

CONFLICTS WITH PIPES, VENTS, AND CONDUITS IN THE WALL.9. IF ACCESSORY IS ABOVE AND BELOW THE TOP OF WAINSCOT FINISH MATERIAL

PROVIDE AN ALUMINUM CHANNEL OR OTHER FILLER TO ELIMINATE GAP BETWEEN ACCESSORY FLANGE AND FINISH FACE OF WALL.

TOILET ROOM GENERAL NOTESPLUMBING FIXTURE SCHEDULEID DESCRIPTION ADA

A WATER CLOSET (BARIATRIC)B LAVATORY

YESYES

ACCESSORIES SCHEDULEID DESCRIPTION

1 36" GRAB BAR2 42" GRAB BAR3 18" GRAB BAR4 TOILET TISSUE DISPENSER

REMARKSMODEL #

5 24" x 36" MIRROR6 PAPER TOWEL DISPENSER7 SOAP DISPENSER8 COAT HOOK

1011 TRASH RECEPTACLE

MFR

REUSE EXISTING

9

REUSE EXISTING

REUSE EXISTINGREUSE EXISTING

#9124BRADLEY DOUBLE HOOK SS1-Teak-Left-Hand-01GBS 34.5" x 21" x 16"

REUSE EXISTINGCUSTOM

#P0955KICHLER

FULL WIDTH MIRROR W/ WOOD FRAMEADA SHOWER BENCH

C SHAMPOO SINK YESD TUB (PURCHASED / INSTALLED BY CONTRACTOR) YESE SHOWER YES

REUSE EXISTINGREUSE EXISTING

12 CUBICLE CURTAIN W/ TRACK TBD13 BARIATRIC LIFT14 BARIATRIC SHOWER CHAIR

ARJOHUNTLEIGHARJOHUNTLEIGH

16 42" FLIP UP GRAB BAR ACCESSIBLE ENVIRONMENTS

97-2254GLEG15 BATHING GURNEY ARJOHUNTLEIGH

TENORCARMINAMIRANTI

SIDE ELEVATIONWATER CLOSET PLAN FRONT ELEVATION LAVATORY SECTION

TYPICAL RESTROOM ACCESSORY MOUNTING HEIGHTS (NOT ALL WILL BE USED ON THIS PROJECT)

44"- 48"

* COORDINATE WALL MOUNTED WATER CLOSET WITH GRAB BAR MOUNTING HEIGHT REQUIREMENTS

* TOP OF SINK RIM OR TOP OF COUNTER, WHICHEVER IS GREATER

TO REFLECTIVE SURFACE

40" (MAX)

6" (MAX)

9" (MIN)

ADA COMPLIANT FAUCET

MIRROR

27" (MIN)

34" * (MAX)

FLUSH CONTROL ON APPROACH SIDE

NOTE: PROVIDE ADA COMPLIANT INSULATION FOR EXPOSED PIPES UNDER LAVATORIES

PROTRUDING DISPENSER LOCATION BELOW GRAB BAR

NOTE: THESE MOST STRINGENT REQUIREMENTS COMPLY WITH ICC A117.1-2009, IBC 2012, AND ADA 2010

16"-18"

33"-36

"

CLEAR

59" (MIN)

CLEAR

60" (MIN)

12" (MAX) 42" (MIN)

39"-41"

(MIN)

18"

(MIN)

18"

(MIN)

1 1/2"

24" (MIN) 12" (MIN)

36" (MIN)

SANITARY NAPKIN

DISPENSER

TOILET SEAT COVER

DISPENSER

HAND DRYER

TOWEL DISPENSER

WASTE RECEPTACLE

17"-19"

39"-41"FLOOR MOUNTED ADULT WATER CLOSET SHOWN

8" (MIN) KNEE CLEARANCE

11" (MIN) KNEE CLEARANCE

[56" (MIN) FOR

ADULT WALL HUNG

WATER CLOSETS]

54" (MIN)

* RESTROOM ACCESSORIES NOT PERMITTED TO PROTRUDE GREATER THAN 4" INTO PEDESTRIAN CIRCULATION PATH

CLEAR

48" (MIN)

CLEAR

30" (MIN)

EQ EQ

LAVATORY PLAN

17"-25"

42" (MAX)

7"-9"

CLEAR FLOOR SPACE

CLEAR FLOOR SPACE

TOWEL DISPENSER / WASTE RECEPTACLE

BABY CHANGING STATION

34" (MAX)

27" (MIN)

17"-25"

24" (MIN)

1. UNLESS NOTED OTHERWISE, LOCATE FINISH OPENINGS 6" FROM ADJACENT WALL.

2. PROVIDE WOOD BLOCKING TO MOUNT ALL WALL STOPS.3. "MFR STD" DENOTES MANUFACTURER STANDARD.4. UNLESS NOTED OTHERWISE, ALL INTERIOR GLAZING SHALL BE 1/4" SAFETY

GLASS5. ALL LOCK SETS AND LATCH SETS SHALL BE LEVER TYPE TO MEET ICC A117.1

AND ADA STANDARDS.6. DOOR CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90

DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS MINIMUM.

7. DOOR-OPENING FORCE FOR INTERIOR HINGED DOORS: 5.0 POUNDS MAXIMUM.8. HARDWARE SHALL BE 34 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE

THE FLOOR. 9. F-NUMBERS REFER TO FUNCTIONS OF BHMA SERIES 4000 BORED LOCKS.10. THRESHOLDS SHALL BE NO HIGHER THAN 1/2" ABOVE FINISH FLOOR. EDGES

OF THRESHOLD SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1 IN 2.11. PROVIDE 18" CLEAR SPACE ON STRIKE/PULL SIDE OF ALL DOORS AND PROVIDE

12" CLEAR SPACE ON STRIKE/PUSH SIDE OF DOORS FOR DOORS WITH LATCH AND CLOSER.

HARDWARE DEVICES DOOR NOTES:DOOR AND FRAME MATERIALS

HARDWARE MATERIALS AND FINISHES (BHMA)

#600 PRIMED FOR PAINTING#605 BRIGHT BRASS#612 SATIN BRONZE#613 DARK SATIN BRONZE, OIL RUBBED#626 SATIN CHROME PLATED ON BRASS#628 SATIN ALUMINUM, CLEAR ANODIZED#630 SATIN STAINLESS STEEL#632 BRIGHT BRASS PLATED ON STEEL (FOR FIRE RATED HINGES)#652 SATIN CHROME, PLATED STEEL (FOR FIRE RATED HINGES)

AL ALUMINUMEMB EMBOSSED HARD BOARD FACEFG FIBERGLASSGL GLASSGALV GALVANIZEDHM HOLLOW METALINS INSULATEDPLAM PLASTIC LAMINATESG SAFETY GLASS (TEMPERED OR LAMINATED SAFETY GLASS)SS 18 GAUGE STAINLESS STEELSTL STEELWD WOODWD/HC WOOD HOLLOW COREWD/SC WOOD SOLID COREWG WIRE GLASS

ADB AUTOMATIC DOOR BOTTOMAP ARMOR PLATEAST ASTRAGALBB 1 1/2 PAIR BUTT HINGES PER LEAF FOR DOORS 7'-0" HIGH, 2 PAIR FOR DOORS OVER 7'-0" HIGHCL CLOSERCR CARD READERDH DOOR HOLDERDL DUMMY LEVERES ELECTRIC STRIKEFB FLUSH BOLTFS FLOOR STOPHPS HINGE PIN DOOR STOPKP KICKPLATELSC LOCK SET, CLASSROOM (F84)LSE LOCK SET, ENTRANCE (F81)

LSP LOCK SET, PRIVACY (F76)LSS LOCK SET, STOREROOM (F86)LTC LATCH SET (F75)ML MAGNETIC LATCHMAG MAGNETIC HOLD OPENMD MOTION DETECTORPP PUSH PULLSB SLIDEBOLTSH SPRING HINGESSIL SILENCERSSW SWEEPTH THRESHOLDWS WEATHER STRIPPINGWST WALL STOPXR EXIT DEVICE, RIM TYPEXVE EXIT DEVICE, VERTICAL ROD, EXPOSEDXVC EXIT DEVICE, VERTICAL ROD, CONCEALED

SEE PARTITION TYPE

SEE PARTITION TYPE

5/8"

2"

TYPICAL JAMB

HEAD

HOLLOW METAL FRAME

HOLLOW METAL FRAME

HM FRAME ANCHOR (3 PER JAMB MIN)

1/2" 1/2"

DOOR THICKNESS + 3/16" DOOR THICKNESS + 3/16"

DOUBLE STUDS AT JAMBS

METAL STUD BOTTOM TRACK

BATT INSULATION - SEE PARTITION TYPES

BATT INSULATION - SEE PARTITION TYPES

5/8"

2"

1/2" 1/2"

DOOR THICKNESS + 3/16" DOOR THICKNESS + 3/16"

* AT NON-BEARING WALL OPENINGS LESS THAN 7'-0"

FINISH FLOOR

SEE SCHEDULE

SEE SCHED

A

FINISH FLOOR

SEE SCHEDULE

2"

2"SEE SCHED2"

1

D

E

A

10

B

C

7

5

6

5

9

TOILET

1058A

BATHING SUITE1058

STOR1058C

STOR1058B

LOUNGE1057

CLOSET1078

CORRIDOR1075

SEMI-PRIVATEUNIT

1059

B

7

6

11

1

42

3

8

8

A-501

1

A-501

543

2

12

12

2'-0"

16

6" 1'-6"

13

14

15

AREA OF WORK

© 2018 BERNARDON PC

Sheet Number:

Sheet Title:

Project Number:

Contact:

Drawn:

Reviewed:

Owner:

Revision/Issue:

Project:

William E. Holloway, AIA

Bernardon PC

C:\

Rev

it L

oca

ls\8

347

_1

1-1

7 D

E V

ets

Blu

e W

ing B

athin

g S

uit

e_d

quai

nta

nce

.rvt

9/1

8/2

018 1

:39

: 43 P

M

A-401

DJQ

8347.11-17

FIXTURE PLAN ANDDOORS

Delaware Veterans HomeBLUE WING BATHINGSUITE RENOVATION100 Delaware VeteransBoulevardMilford, DE 19963

RET

Bill Holloway, AIA

STATE OF DELAWAREOMB - DFMThomas Collins Building540 S. DuPont HighwayDover, DE 19901

0' 2' 8'4'

SCALE: 1/4" = 1'-0"

TYPICAL RESTROOM ACCESSORY MOUNTING HEIGHTS DIAGRAM0' 2' 8'4'

DOOR SCHEDULE

DOOR NO ROOM NAME

DOOR FRAME

SILLFIRE

RATING HARDWAREHDW

FINISH REMARKSTYPE WIDTH HEIGHT THICK MATL FINISH TYPE MATL FINISH JAMB HEAD

1058 BATHING SUITE A 4'-0" 7'-0" 1 3/4" 1 NEW ELEC STRIKE / MAG LOCK EXIST NEW CARD READER

1058A TOILET A 4'-0" 7'-0" 1 3/4" WD/SC STN 1 HM PTD 3/A-401 3/A-401 - BB, LSP, TH, WST #628

1058B STOR A 2'-0" 7'-0" 1 3/4" WD/SC STN 1 HM PTD 3/A-401 3/A-401 - BB, LSS, WST #628

1058C STOR A 2'-0" 7'-0" 1 3/4" WD/SC STN 1 HM PTD 3/A-401 3/A-401 - BB, LSS, WST #628

1078 LOUNGE A 6'-0" 7'-0" 1 3/4" WD/SC STN 1 HM PTD 3/A-401 3/A-401 - BB, LSS, WST #628 TWO (2) EQUAL LEAFS

SCALE: 3" = 1'-0"3INTERIOR HM DOOR DETAIL

0" 2" 8"4"

SCALE: 1/4" = 1'-0"

DOOR TYPESSCALE: 1/4" = 1'-0"

DOOR FRAME TYPES0' 2' 8'4' 0' 2' 8'4'

N

SCALE: 1/4" = 1'-0"1FIXTURE PLAN KEY PLAN

N

EXISTING DOOR TO REMAIN

0 9/18/18 Issued for Bid

Page 6: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet

34" (MAX)

29" (MIN)

MIRROR

1/2" SOLID SURFACE COUNTERTOP WITH BULLNOSE EDGE

INTEGRATED SINK

REMOVABLE PLAM APRON

27" (MIN)

LINE OF ADA CLEARANCE

(MIN)

9"

SCRIBE MATCHING BACKSPLASH AND SIDESPLASH AT WALL AND APPLY CONT SEALANT TO MATCH FINISH

* COORDINATE PLUMBING WITH APRON

4"BOTTOM OF REFLECTIVE SURFACE

40" (MAX)

8" (MIN)

11" (MIN)

2'-0" (MAX)

SCHEDULED BASE SCHEDULED FLOOR TILE

SCHEDULED WALL TILE

PLAM PANEL

6A-501

MIRROR

PAINT SOFFIT ABOVE P-1

SS-1

PL-1

B-1

WT-1

TILE ACCENT BAND (SEE DETAIL 4/ A-121)

B-1

4'-11"

5"3'-8"

6A-501

9A-501

4'-0" 1'-6"

END PANEL

WT-1

MIRROR

P-1

PL-1 PL-1

B-1

SS-1

7A-501

8A-501

5'-0"

2'-0"1'-0"6'-0 1/2"1'-0"2'-0"

2'-9 1/2"

4'-4 1/2" TV

C L

WT-1

PL-1

PL-1

PL-1

PL-1

PL-1

PL-1

B-1

TILE ACCENT BAND (SEE DETAIL 4/A-121)

WT-1

B-1

4"4'-7"

5"2'-8"

2'-9 1/2"

* REFER TO SPECIFICATION FOR HARDWARE

2'-0"

1 1/2"

PLAM DRAWER WITH FULL EXTENSION DRAWER SLIDES

4"

6"

1'-2"

1'-0"

1/2" SOLID SURFACE COUNTERTOP WITH BULLNOSE EDGE

SCRIBE MATCHING BACKSPLASH AND SIDESPLASH AT WALL AND APPLY CONT SEALANT TO MATCH FINISH

1'-11"

SCHEDULED BASESCHEDULED FLOOR TILESCHEDULED WALL TILE

4'-4 1/2"

2'-9 1/2"

* REFER TO SPECIFICATION FOR HARDWARE

WHITE MELAMINE ON ALL EXPOSED INTERIOR SURFACES (TYP)

3/4" MELAMINE ADJUSTABLE SHELF WITH PLAM FRONT EDGE

PLAM CABINET DOOR

1/2" SOLID SURFACE COUNTERTOP WITH BULLNOSE EDGE. SCRIBE MATCHING BACKSPLASH AND SIDESPLASH AT WALL AND APPLY CONT SEALANT TO MATCH FINISH

1 1/2"

6"

1'-11"

WHITE MELAMINE ON ALL EXPOSED INTERIOR SURFACES (TYP)

3/4" MELAMINE ADJUSTABLE SHELVES WITH PLAM FRONT EDGE

1x3 CONT FRENCH CLEAT ATTACHED TO STUDS

1'-0"

2'-0"

SCHEDULED BASESCHEDULED FLOOR TILESCHEDULED WALL TILE

2'-9 1/2"

* REFER TO SPECIFICATION FOR HARDWARE

WHITE MELAMINE ON ALL EXPOSED INTERIOR SURFACES (TYP)

3/4" MELAMINE ADJUSTABLE SHELF WITH PLAM FRONT EDGE

PLAM CABINET DOOR

1/2" SOLID SURFACE COUNTERTOP WITH BULLNOSE EDGE. SCRIBE MATCHING BACKSPLASH AND SIDESPLASH AT WALL AND APPLY CONT SEALANT TO MATCH FINISH

1 1/2"

6"

APPLY SS-2 TO WALL BEHIND SINK

1'-11"

2'-0"

2'-0"

SCHEDULED BASESCHEDULED FLOOR TILESCHEDULED WALL TILE

CASEWORK GENERAL NOTES1. PROVIDE NEW WOOD BLOCKING IN EXISTING WALL AS REQUIRED FOR NEW

CASEWORK. COORDINATE WITH CASEWORK SUPPORT REQUIREMENTS.

© 2018 BERNARDON PC

Sheet Number:

Sheet Title:

Project Number:

Contact:

Drawn:

Reviewed:

Owner:

Revision/Issue:

Project:

William E. Holloway, AIA

Bernardon PC

C:\

Rev

it L

oca

ls\8

347

_1

1-1

7 D

E V

ets

Blu

e W

ing B

athin

g S

uit

e_d

quai

nta

nce

.rvt

9/1

8/2

018 1

:39

: 44 P

M

A-501

DJQ

8347.11-17

INTERIORELEVATIONS ANDCASEWORK

Delaware Veterans HomeBLUE WING BATHINGSUITE RENOVATION100 Delaware VeteransBoulevardMilford, DE 19963

RET

Bill Holloway, AIA

STATE OF DELAWAREOMB - DFMThomas Collins Building540 S. DuPont HighwayDover, DE 19901

SCALE: 1 1/2" = 1'-0"6LAVATORY SECTION

0" 3" 6" 1'

SCALE: 1/4" = 1'-0"1ELEVATION 1081A NORTH

SCALE: 1/4" = 1'-0"2ELEVATION 1081 NORTH

SCALE: 1/4" = 1'-0"3ELEVATION 1081 EAST

SCALE: 1/4" = 1'-0"4ELEVATION 1081 SOUTH

SCALE: 1/4" = 1'-0"5ELEVATION 1081 WEST

0' 2' 8'4'

0' 2' 8'4'

0' 2' 8'4'

0' 2' 8'4'

0' 2' 8'4'SCALE: 1 1/2" = 1'-0"7BASE CABINET WITH DRAWERS

SCALE: 1 1/2" = 1'-0"8BASE CABINET WITH OPEN SHELVING

0" 3" 6" 1'

0" 3" 6" 1'

SCALE: 1 1/2" = 1'-0"9BASE CABINET

0" 3" 6" 1'

0 9/18/18 Issued for Bid

Page 7: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet

EXISTING BRICK TO REMAIN

NEW FACE BRICK, MATCH EXISTING ADJACENT

EXISTING CONCRETE SLAB TO REMAIN

EXISTING FOUNDATION TO REMAIN

EXISTING GRADE

EXISTING SOFFIT TO REMAIN

EXISTING ROOF CONSTRUCTION TO REMAIN

EXISTING GYP BD, PATCH AND REPAIR AS REQUIRED

EXISTING VAPOR BARRIER TO REMAIN

NEW MTL STUDS W/ BATT INSULATION, MATCH EXISTING ADJACENT STUD SIZE / SPACING AND INSULATION R-VALUE

NEW GYP BD

EXISTING ROWLOCK COURSE TO REMAIN

EXISTING GYP SHEATHING TO REMAIN

NEW 5/8" GOLD BOND SHEATHING OR MATCH EXISTING ADJACENT

EXISTING BUILDING WRAP SYSTEM TO REMAIN

NEW VAPOR PERMEABLE WATERPROOFING SYSTEM, MATCH EXISTING ADJACENT

EXISTING MTL STUDS W/ BATT INSULATION TO REMAIN

NEW VAPOR BARRIER, MATCH EXISTING ADJACENT

EXISTING HEADER TO REMAIN

WEEPS @ 24" OC

NEW MTL FLASHING

NEW ALUMINUM BREAK METAL FASCIA

EXISTING BRICK TO REMAIN

NEW 3M FASARA LUCE FILM ON EXTERIOR OF LOWER GLASS PANEL OF EXISTING DOUBLE HUNG WINDOW

EXISTING CONCRETE SLAB TO REMAIN

EXISTING FOUNDATION TO REMAIN

EXISTING GRADE

EXISTING ROOF CONSTRUCTION TO REMAIN

EXISTING GYP BD, PATCH AND REPAIR AS REQUIRED

EXISTING VAPOR BARRIER TO REMAIN

NEW 1/2" PLYWOOD, PTD

NEW GYP BD, FLUSH W/ EXISTING ADJACENT

EXISTING ROWLOCK COURSE TO REMAIN

EXISTING GYP SHEATHING TO REMAIN

EXISTING BUILDING WRAP SYSTEM TO REMAIN

EXISTING MTL STUDS W/ BATT INSULATION TO REMAIN

NEW WD STUDS, SIZE TO FIT CAVITY

EXISTING HEADER TO REMAIN

EXISTING ALUM CLAD WD DOUBLE HUNG WINDOW TO REMAIN, FASTEN PERMENANTLY SHUT

EXISTING BRICK TO REMAIN

EXISTING SOLDIER COURSE TO REMAIN

MATCH EXISTING CHECK RAIL HEIGHT

5'-3" +/-

NEW WD SILL TO MATCH EXISTING, PTD

ALIGN

© 2018 BERNARDON PC

Sheet Number:

Sheet Title:

Project Number:

Contact:

Drawn:

Reviewed:

Owner:

Revision/Issue:

Project:

William E. Holloway, AIA

Bernardon PC

C:\

Rev

it L

oca

ls\8

347

_1

1-1

7 D

E V

ets

Blu

e W

ing B

athin

g S

uit

e_d

quai

nta

nce

.rvt

9/1

8/2

018 1

:39

: 44 P

M

A-601

DJQ

8347.11-17

EXTERIORWINDOWS ANDDETAILS

Delaware Veterans HomeBLUE WING BATHINGSUITE RENOVATION100 Delaware VeteransBoulevardMilford, DE 19963

RET

Bill Holloway, AIA

STATE OF DELAWAREOMB - DFMThomas Collins Building540 S. DuPont HighwayDover, DE 19901

SCALE: 1" = 1'-0"1WALL SECTION - WINDOW INFILL

SCALE: 1" = 1'-0"2WALL SECTION - CLERESTORY WINDOW

0" 6" 2'1' 0" 6" 2'1'

0 9/18/18 Issued for Bid

Page 8: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet
Page 9: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet
Page 10: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet
Page 11: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet
Page 12: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet
Page 13: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet
Page 14: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet
Page 15: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet
Page 16: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet
Page 17: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet
Page 18: BLUE WING BATHING SUITE RENOVATION · EXP Expansion EXT Exterior FA Fire Alarm FD Floor Drain FDN Foundation FE Fire Extinguisher FEC Fire Extinguisher Cabinet FHC Fire Hose Cabinet