body oem unit dimensions /mount for supra s6, s7, s8 s9 · 2020. 7. 30. · athens, ga 30601 usa...

1
Unit Weights Carrier Transicold reserves the right to modify this information and model design without prior notice, in line with our policy of continuous improvement of design, quality and performance. 3.9" min. 75.4” 11.3” 3.2” 21.7” 48.2” 24.2” 0.9” E Required Opening C L 49” 24.5” 51.4” 25.7” 16.1” 1.1 12.2” 13.8" (S10) 5.5” 1” 24.8” 35.2” = = F W 30.6” 9.5”/11.5" (S10) 3.5”/4.1" (S10) 7.1” min. 11.4”/13" (S10) 14.6” 26.3° 16.6" 4.7” 5” Mounting Bolts Axis All dimensions are in inches and for reference only A B C 4” 2” 59” B B A C Minimum clearance around evaporator Body OEM Unit Dimensions /Mount for Supra S6, S7, S8, S9 and S10 ©2020 Carrier Corporation - Printed in U. S. A. - 04/2020 Carrier Transicold P.O. Box 4805 Syracuse, NY 13221 USA North America Carrier Transicold 700 Olympic Drive Athens, GA 30601 USA Central America and Mexico Ejercito Nacional 253A Piso 5 Colonia Anahuac 11320 Mexico, D.F. 62-12125 Rev C 32.1” Key CL = Center Line E = Exhaust Pipe F = Fuel Line W = Water Drain Mounting Bolts (Qty 4) Diameter: 1/2" - 13 UNC-2A Grade: 5 (SAE) Length: 3.5" from Mounting Surface Alternative for recessed body installation Mounting Bolts Locations 15.6" (S10) 23.5" (S10) 4 - Ø0.625” Road Only Standby S6 844 lbs 950 lbs S7/S8 860 lbs 955 lbs S9 908 lbs 1015 lbs S10 1023 lbs 1060 lbs

Upload: others

Post on 17-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Unit Weights

    Carrier Transicold reserves the right to modify this information and model design without prior notice, in line with our policy of continuous improvement of design, quality and performance.

    3.9"

    min

    .

    75.4”

    11.3”

    3.2”

    21.7”

    48.2

    24.2

    ”0.

    9”

    E

    Required Opening

    CL

    49”

    24.5”

    51.4”

    25.7”

    16.1

    1.1 12.2

    ”13

    .8" (

    S10)

    5.5”

    1”

    24.8”

    35.2” == FW

    30.6”

    9.5”

    /11.

    5" (S

    10)

    3.5”/4.1" (S10)

    7.1”

    min

    .

    11.4

    ”/13"

    (S10

    )

    14.6

    26.3°16.6"

    4.7”

    5”

    Mounting Bolts Axis

    All dimensions are in inches and for reference only

    A B C

    4” 2” 59”

    B

    B

    A

    C

    Minimum clearance around evaporator

    Body OEM Unit Dimensions /Mount for

    Supra S6, S7, S8, S9 and S10

    ©2020 Carrier Corporation - Printed in U. S. A. - 04/2020

    Carrier TransicoldP.O. Box 4805Syracuse, NY 13221 USA

    North AmericaCarrier Transicold700 Olympic DriveAthens, GA 30601 USA

    Central America and MexicoEjercito Nacional 253−A Piso 5 Colonia Anahuac11320 Mexico, D.F.

    62-12125 Rev C

    32.1”

    Key CL = Center Line E = Exhaust Pipe F = Fuel Line W = Water Drain

    Mounting Bolts (Qty 4) Diameter: 1/2" - 13 UNC-2A Grade: 5 (SAE)Length: 3.5" from Mounting Surface

    Alternative for recessed body

    installation

    Mounting Bolts Locations

    15.6" (S10)

    23.5" (S10)

    4 - Ø0.625”

    Road Only StandbyS6 844 lbs 950 lbsS7/S8 860 lbs 955 lbsS9 908 lbs 1015 lbsS10 1023 lbs 1060 lbs