boiler assessment matrix
TRANSCRIPT
![Page 1: Boiler Assessment Matrix](https://reader035.vdocument.in/reader035/viewer/2022082201/577ccdda1a28ab9e788cce1a/html5/thumbnails/1.jpg)
Plant Component Chart for Condition Assessment Services
Hone & Glow ®
locates header ligament cracks
NOTIS®
evaluates superheater tube life
FHyNES®
detects internal furnace tube damage
The Acoustic Ranger®
locates holes and pluggage inair heater tubes
FST-GAGE®
EMAT for tube thickness
Header/Pipingremaining life analysis
Leak-Before-Break AnalysisPCFAD® Software
Support Load Analysis
Stress/Strain Measurement
Valve Leak Detection
High Te
mp. Hea
ders
High Te
mp. Pip
ing
Rehea
ter Tu
bes
Low Te
mp. Hea
ders
Furna
ce W
all Tu
bes
Tubu
lar Ai
r Hea
ters
Conve
ction
Pass
Tube
s
Econ
omize
r Tub
es
Downc
omers
Drum Valve
Unique or PatentedB&W Services
Supe
rheate
r &
High Te
mp. Hea
ders
High Te
mp. Pip
ing
Rehea
ter Tu
bes
Attem
perat
ors
Low Te
mp. Hea
ders
Furna
ce W
all Tu
bes
Conve
ction
Pass
Tube
s
Econ
omize
r Tub
es
Downc
omers
Drum Deaera
torsStandard B&W
Testing and SamplingSu
perhe
ater &
UT Flaw Sizing(EPRI and/or ASME Section V)
Sample Analysis
Cycling AnalysisT/C data acqusition
Dye PenetrantSurface Tests (PT)
Magnetic ParticleSurface Tests (MT)
Material Verification
Ultrasonic ThicknessTesting (UTT)
Ultrasonic Testing (UT)Shearwavefor flaw detection (EPRI and/or ASME)
Replication AnalysisSurface Metallography
Remote Visual Inspectionof Inside Surface
![Page 2: Boiler Assessment Matrix](https://reader035.vdocument.in/reader035/viewer/2022082201/577ccdda1a28ab9e788cce1a/html5/thumbnails/2.jpg)
While others may use the Babcock name, we arethe original Babcock & Wilcox with more than130 years of experience in engineering, constructingand servicing steam generating systems. Insist onus by name.
For more information, or a complete listing ofour sales and service offices worldwide, call1-800-BABCOCK (222-2625) in North America.Outside North America, call (330) 753-4511 orfax (330) 860-1886 (Barberton, Ohio, USA). Oraccess our Web site at http://www.babcock.com.
Canada:Cambridge, OntarioEdmonton, AlbertaMontreal, QuebecSaint John, New BrunswickVancouver (Richmond), British Columbia
Denmark: EsbjergIndia: PuneIndonesia: JakartaPeople’s Republic of China: BeijingSingapore: SingaporeUnited States of America:
Atlanta, GeorgiaBarberton, OhioCharlotte, North CarolinaChicago (Downers Grove), IllinoisCincinnati, OhioDallas, TexasDenver (Sheridan), ColoradoFairfield, New JerseyHouston, TexasKansas City, MissouriMt. Holly, New JerseySan Francisco (Napa), CaliforniaSt. Petersburg, Florida
Powering the World Through Teamwork and Innovation®
The information contained herein is provided for general informationpurposes only and is not intended or to be construed as a warranty, anoffer, or any representation of contractual or other legal responsibility.
PS-272C 5MI1B
© 2001 The Babcock & Wilcox Company. All rights reserved.
Powering the World Through Teamwork and Innovation, Hone & Glow,NOTIS, FHyNES, The Acoustic Ranger, FST-GAGE, and PCFAD aretrademarks of The Babcock & Wilcox Company.
The FST-GAGE® is a licensed EPRI product.
B&W Field Support Expertise• Trained and experienced
service engineers• Service specialists
- Boiler structural- Air heaters- Pulverizers- Scrubbers- Water chemistry and
chemical cleaning• Metallurgists• On-site project management• Condition assessment specialists