boiler mountings and accesseries
TRANSCRIPT
![Page 1: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/1.jpg)
1
STUDY OF
BOILER MOUNTINGS&
ACCESSORIES
byProf. S. R. Khandagale
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
![Page 2: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/2.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
2
Mountings: The items which are used for safety of boiler are called mountings
Accessories:
The items which are used for increasing the boiler efficiency are called accessories
![Page 3: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/3.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
3
MOUNTINGS 1. Water Level indicator2.Pressure Gauge3. Safety valves A. Dead weight safety valve B. Spring loaded safety valve C. Lever controlled safety valve D. High steam & low water safety valve4. Fusible plug5. Blow-off cock6. Steam stop valve7.Feed check Valve
![Page 4: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/4.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
4
Water Level indicator
For indicating water level inside boiler
Usually 2 Nos.
Steel balls are provided to prevent loss of steam in case of glass breakage
![Page 5: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/5.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
5
Pressure Gauge
To indicate level of steam pressure inside the boiler
![Page 6: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/6.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
6
Safety valves• Safety valve releases steam outside of boiler in
case of excess pressure inside
A. Dead weight safety valve B. Spring loaded safety valve C. Lever controlled safety valve D. High steam & low water safety valve
![Page 7: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/7.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
7
![Page 8: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/8.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
8
High steam & low water safety valveActuates in 2 situations
1. Water level lowers 2. steam pressure increases
![Page 9: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/9.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
9
FUSIBLE PLUG
Function is to extinguish (switch off )fire when water level in boiler falls below certain limit
Fusible material is having low MP
e.g. brass, gunmetal
![Page 10: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/10.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
10
BLOW OFF COCK• To drain out water
from the boiler for internal cleaning inspection or other purposes
• Fitted at lowest part of boiler
![Page 11: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/11.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
11
STEAM STOP VALVERegulates the flow of a steam
Function : to shut off or regulate the flow of steam from the boiler to the steam pipe or steam from the steam pipe to the engine
![Page 12: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/12.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
12
FEED CHECK VALVE• To allow the feed
water to pass in to the boiler
• To prevent the back flow of water from the boiler in the event of the failure of the feed pump
![Page 13: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/13.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
13
1. Economizer2. Preheater3. Superheater4.Steam separator5.Injector6. Feed pump
ACCESSORIES
![Page 14: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/14.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
14
Economizer ,Preheater & Superheater
Use to recover some heat being carrying by exhaust flue gases.
Heat recovered is utilized in --> Economizerraising the temperature of the feed water
Heat recovered is utilized in --> air preheaterraising the temperature of the fresh air
Heat recovered is utilized in --> super heaterraising the temperature of the (saturated )steam
![Page 15: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/15.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
15
![Page 16: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/16.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
16
SUPERHEATER
![Page 17: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/17.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
17
AIR PREHEATER
![Page 18: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/18.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
18
GREEN’S ECONOMISER
![Page 19: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/19.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
19
STEAM SEPERATOR
• Separates moisture contain in steam and makes it dry
![Page 20: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/20.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
20
STEAM INJECTOR
Function of injector is to feed water into the boiler
It is commonly employed for vertical and locomotive boilers
Not suitable for large capacity high pressure boilers
Also used where the space is not available for the installation of feed pump
![Page 21: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/21.jpg)
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra
21
FEED PUMP• Used to deliver feed water to the boiler.
• It is desirable that the quantity of water supplied should be at least equal to that evaporated and supplied to the engine
• Two types of which are commonly used as feed pumps are
• (1) reciprocating pump • (2) rotary pump
![Page 22: boiler mountings and accesseries](https://reader033.vdocument.in/reader033/viewer/2022061500/58796d881a28ab37368b53ff/html5/thumbnails/22.jpg)
22
RECIPROCATING TYPE BOILER FEED PUMP
Prof. S.R. Khandagale,JJMCOE,Jaysingpur,Mahrashtra