bombas com variadores de frequência inteligentes integrados
TRANSCRIPT
nº do arquivo: 100.11ptdata: agosto de 2017
substitui o: 100.11ptdata: junho de 2017
Bombas inteligentesde velocidade variável
tm
d e s c r i ç ã o d a s o l u ç ã o
5.25 6.50
c
b
a
no. revision date
tolerances
decimals
2 places .010
3 places .005s.a. armstrong limited
scarborough canada
used on: name of part
numberdrawn by date
checked scale
num
ber
25.0°
12.5°
5.25 6.50
drill and tap4 sets of 2holes through1/4"x2 0unc
'a' b
ore
6.12
dia
.
7.00
55
2.49
9
1.874
'a'
'a'
(8) holes .687 dia. drill thruequally spaced on 8.031 p.c.d.straddling centres.
1.31
dia.
9.12
dia
. (re
f.)
2.49
7 di
a.
1.877
dia
.
15°
2.06
0.06
0.16 0.81
7.00
40 d
ia.
1.37
0.87
0.31
.002-a-
125
125
2.198
0.56
2.188
.703 drill x 1.75 deeptap .50 npt (1) hole
.002a
125
.002c
.015 x 45°chamfer
.002a-b-
b .002
125
r0.03max.
ref.
(4) holes .437 dia. drill thruequally spaced on 5.875 p.c.d.straddling centres.
45°
'b' 'b'
(4) holes drill .312 dia. x .75 deeptap .375-16unc x .56 deep equallyspaced on 3.280 p.c.d. straddlingcenters.
0.31
.25 dia. drill thru
.437 dia. drill x .50 deeptap .25 npt- (1) hole.(for groups 012, 032, 042,
datu
m
r0.03
.03 x 45°chamfer0.28
9.50
clean up ifnecessary
45°
57°
512, 532, 542 only)
f 0.002 d
a
NOTE:1. THE SECTION VIEW A-A IS ROTATED 90 ° CW.2. EPDM 1 TO BE VULCANIZED OVER STAINLESS STEEL INSERT 2 .3. EPDM ELASTOMER HARDNESS TO BE 70-DUROMETER TO ASTM D14154. MACHINING TOLERANCES APPLY TO THE ENTIRE DRAWING
a
c
D
e
6 5 4 1
MICROINCHES
INCHStandard
N/A4302, 4382 DUAL ARM PUMPS
GD&T to follow ASME14.5 R2009
6/21/20116/20/2011
IniIniIniGLSD
1 of 20.038220
--
1:1
B 428493-003
3rd ANGLE PROJECTION
TITLE:
REV:DRAWING NO:SIZE:
SHEET:MASS [kg]:SCALE:
COMMENTS:ENG APPMFG APPQ.A.
CHECKDRAWN
DATENAME
USED ON:
STANDARD:SURFACE FINISH:
UNITS OF MEASUREMENT:
CAVITY NUMBER TO BE AGREED ANDIDENTIFIED ON MULTICAVITY TOOLS
ANGULAR TOLERANCE:X ° ±.5 °X.X ° ±.1 °
MACHINING TOLERANCE:X.X ±.0310 [0.762]X.XX ±.0100 [0.254]X.XXX ±.0050 [0.127]X.XXXX ±.0005 [0.0127]
UNLESS OTHERWISE SPECIFIED:
The information contained inthis drawing is the sole propertyof S.A. Armstrong Ltd. Anyreproduction in part or wholewithout written permission ofS.A. Armstrong Ltd. isprohibited.
4284
93-0
03pa
rt n
o:
3IN. DUAL ARM VALVE SEAT
MASS [kg(lb)] DIMMENSIONMATERIALPOSITIONPART №
ECO № DATE APPROVEDREVISION23
5 1346 2
b
C
A
d
E
B
CASTING TOLERANCE:0 � 3 [0 � 76.2] ±.031 [±0.79]3 � 7 [76.2 � 177.8] +.094, -.063 [+2.38, -1.58]7 � 20 [177.8 � 508] +.125, -.063 [+3.17, -1.58]20 � 100 [508 � 2540] ±.125 [±3.17]
-- ECO 9639 11-06-21 GL
428493-003 2 ASTM D1418 EPDM 0.011(0.026) 3.587X2.300X.290428493-103 1 SST AISI-304 16GA 0.027(0.058) 3.587X2.300X.0625
2x r.175
r1.510
2x r.390
.254.400
r1.720
k .002 a b
k .004
u .002
u .004
j n .002 a b
b .002 a
a
a ab
r1.70
5.0°
20.0°
30.0°
25.0°
30.0°
8x ø .150
1.400
2.500
3.400
.106
.620
r1.900
r1.45
r.33r.33
2.173
.400
2x r.100 ±.005
.32
1.700
.187
k .002
k .002
u .002
u .004
b
b
1 2
.100
2x r.175
2x r.1002x r.280
r1.565
.240.400
2.18
2.500
1.700
3.400
.380
2x r.390
r1.900
r1.400
r1.720 j n .002 a b
2.300
dc
2
1
c .002
c .002
j
.063
section b-b
c .005
c .005
desempenho idealo tempo todo
s bombas Design Envelope da Armstrong são uma solução completa para sistemas de aquecimento, refrigeração e bombeamento. A integração de uma bomba perfeitamente combinada, motor e controlador de velocidade variável inteligente, cria a solução de bombeamento de maior valor agregado.
Motivadas pela responsabilidade social, ambiental ou fiscal, as empresas que pensam no futuro devem adotar as práticas e tecnologias de economia de energia.
Através de avanços nos projetos, a Armstrong eliminou as compensações nos custos que frequentemente acompanham as escolhas sus-tentáveis. A linha Design Envelope oferece o menor custo de instalação e o menor custo por vida útil de qualquer solução de bombeamento atual.
5.25 6.50
As soluções Design Envelope reduzem os custos de bombeamento através da velocidade variável e de uma operação baseada na demanda, que consome apenas a energia necessária, com base na demanda do sistema atual.
As bombas Design Envelope utilizam uma combinação de tamanho de impulsor otimizado e controle de velocidade para uma operação energeticamente eficiente dentro de um envelope
de desempenho estabelecido. Os envelopes de desempenho são selecionados para uma melhor eficiência da bomba onde os sistemas de fluxo variável geralmente operam. Isso garante que o sistema de bombeamento de um edifício consuma o mínimo de energia possível. Isso também garante que a instalação atenda ou exceda as orientações da ashrae 90.1 , que exigem 70% de economia de energia a 50% da carga máxima.
A maioria dos sistemas opera com menos de 60% da capacidade 90% do tempo ou mais.
As bombas tradicionais são projetadas para uma operação de alta eficiência na carga total.
c
b
a
no. revision date
tolerances
decimals
2 places .010
3 places .005s.a. armstrong limited
scarborough canada
used on: name of part
numberdrawn by date
checked scale
num
ber
25.0°
12.5°
5.25 6.50
drill and tap4 sets of 2holes through1/4"x2 0unc
'a' b
ore
6.12
dia
.
7.00
55
2.49
9
1.874
'a'
'a'
(8) holes .687 dia. drill thruequally spaced on 8.031 p.c.d.straddling centres.
1.31
dia.
9.12
dia
. (re
f.)
2.49
7 di
a.
1.877
dia
.
15°
2.06
0.06
0.16 0.81
7.00
40 d
ia.
1.37
0.87
0.31
.002-a-
125
125
2.198
0.56
2.188
.703 drill x 1.75 deeptap .50 npt (1) hole
.002a
125
.002c
.015 x 45°chamfer
.002a-b-
b .002
125
r0.03max.
ref.
(4) holes .437 dia. drill thruequally spaced on 5.875 p.c.d.straddling centres.
45°
'b' 'b'
(4) holes drill .312 dia. x .75 deeptap .375-16unc x .56 deep equallyspaced on 3.280 p.c.d. straddlingcenters.
0.31
.25 dia. drill thru
.437 dia. drill x .50 deeptap .25 npt- (1) hole.(for groups 012, 032, 042,
datu
m
r0.03
.03 x 45°chamfer0.28
9.50
clean up ifnecessary
45°
57°
512, 532, 542 only)
f 0.002 d
NOTE:1. THE SECTION VIEW A-A IS ROTATED 90 ° CW.2. EPDM 1 TO BE VULCANIZED OVER STAINLESS STEEL INSERT 2 .3. EPDM ELASTOMER HARDNESS TO BE 70-DUROMETER TO ASTM D14154. MACHINING TOLERANCES APPLY TO THE ENTIRE DRAWING
a
c
D
e
6 5 4 1
MICROINCHES
INCHStandard
N/A4302, 4382 DUAL ARM PUMPS
GD&T to follow ASME14.5 R2009
6/21/20116/20/2011
IniIniIniGLSD
1 of 20.038220
--
1:1
B 428493-003
3rd ANGLE PROJECTION
TITLE:
REV:DRAWING NO:SIZE:
SHEET:MASS [kg]:SCALE:
COMMENTS:ENG APPMFG APPQ.A.
CHECKDRAWN
DATENAME
USED ON:
STANDARD:SURFACE FINISH:
UNITS OF MEASUREMENT:
CAVITY NUMBER TO BE AGREED ANDIDENTIFIED ON MULTICAVITY TOOLS
ANGULAR TOLERANCE:X ° ±.5 °X.X ° ±.1 °
MACHINING TOLERANCE:X.X ±.0310 [0.762]X.XX ±.0100 [0.254]X.XXX ±.0050 [0.127]X.XXXX ±.0005 [0.0127]
UNLESS OTHERWISE SPECIFIED:
The information contained inthis drawing is the sole propertyof S.A. Armstrong Ltd. Anyreproduction in part or wholewithout written permission ofS.A. Armstrong Ltd. isprohibited.
4284
93-0
03pa
rt n
o:
3IN. DUAL ARM VALVE SEAT
MASS [kg(lb)] DIMMENSIONMATERIALPOSITIONPART №
ECO № DATE APPROVEDREVISION23
5 1346 2
b
C
A
d
E
B
CASTING TOLERANCE:0 � 3 [0 � 76.2] ±.031 [±0.79]3 � 7 [76.2 � 177.8] +.094, -.063 [+2.38, -1.58]7 � 20 [177.8 � 508] +.125, -.063 [+3.17, -1.58]20 � 100 [508 � 2540] ±.125 [±3.17]
-- ECO 9639 11-06-21 GL
428493-003 2 ASTM D1418 EPDM 0.011(0.026) 3.587X2.300X.290428493-103 1 SST AISI-304 16GA 0.027(0.058) 3.587X2.300X.0625
2x r.175
r1.510
2x r.390
.254.400
r1.720
k .002 a b
k .004
u .002
u .004
j n .002 a b
b .002 a
a
a ab
r1.70
5.0°
20.0°
30.0°
25.0°
30.0°
8x ø .150
1.400
2.500
3.400
.106
.620
r1.900
r1.45
r.33r.33
2.173
.400
2x r.100 ±.005
.32
1.700
.187
k .002
k .002
u .002
u .004
b
b
1 2
.100
2x r.175
2x r.1002x r.280
r1.565
.240.400
2.18
2.500
1.700
3.400
.380
2x r.390
r1.900
r1.400
r1.720 j n .002 a b
2.300
dc
2
1
c .002
c .002
j
.063
section b-b
c .005
c .005
0–60%
do tempo
90%
00
5
10
15
20
25
10 20 30 40 50 60 70 80 90 100
perfil de carga t íp ico de um edif íc io
ho
ras
de
ope
raçã
o %
carga de aquecimento/refrigeração %
As bombas Design Envelope são projetadas para uma operação de
alta eficiência com carga parcial
até
65% de economia nos custos de instalação
até
80%de economia de energia
> Operação paralela e redundância gerenciada substitui a operante/reserva
> Relatórios e gerenciamento proativo
> vfd montado em parede/suporte> Sensor remoto> Reduz parcialmente os custos de energia
end suction base montada > Projeto antigo> Caso base para comparação> Troca de selo demorada
> Elimina a necessidade de: Base estrutural, base de inércia, conectores flexíveis, grauteamento
e alinhamento> Custos de mão de obra de
instalação reduzidos> Menor ocupação de espaço na sala
de máquinas (50–75%)
Troca do selo em15 min economiza até $ 700
Economiza mais de $ 5.000,00 para uma bomba de 8".
design envelope tango/dualarm
vertical in-line com controle de velocidade variável
vertical in-line com acoplamento dividido
tango
> Unidades menores são mais fáceis de manusear> Dois dispositivos girantes compartilhando um casco> Desempenho de vida útil otimizado
e dos custos de instalação
evolução do bombeamento
economiza em média
15% da energia
Economia adicional média de $ 2.000,00
> Controlador de velocidade variável sensorless, integrado
> Elimina a fiação do vfd para a bomba e o aterramento do eixo
> Suporta menores seleções de motor> Nenhuma exigência de sensor de
resposta ou fiação bomba de velocidade constante válvula de 3 vias
bomba de velocidade variávelcom controles desativados (bomba em manual)
> Operação com velocidade
constante> Caso base para o uso de
energia da bomba> A bomba é operada no
ponto de projeto, controlada por estrangulamento
> Velocidade constante reduzida
> Reduz a velocidade do motor ao invés de estrangular o fluxo
bomba de velocidade variável controlador
montado na parede/válvula de 2 vias
design envelope vertical in-line
vs.vs.
> Filtro de harmônicas interno> Sem exigências de espaço na parede> Balanceamento automático de vazão com um toque > Conectividade e serviços da Web incorporados
kWh
a 100% da vazãoprojetada
a 50% da vazãoprojetada
kWhA tecnologia de velocidade
variável Design Envelope da Armstrong altera a operação
da bomba dentro de um grande sistema hvac. A inteligência de velocidade vari-ável incorporada no controlador Design Envelope da Armstrong ajusta a opera-ção da bomba para atender à demanda imediata. A bomba responde instanta-neamente e consome apenas a energia necessária para atender à demanda.
economia de energia
e economia de energia
desempenho superior
até
50% de economia de energia
até
70%+ economia de energia
design envelope 3.1
> Controle de velocidade da bomba através da tecnologia sensorless
> Mapeamento detalhado da curva de desempenho
> Seleção de motores meno-res em 25% dos projetos
> Controlador integrado — maior eficiência do motor
> Precisão da medição da vazão de ±5%
> Seleção otimizada em relação ao perfil de carga
até
65% de economia de energia
bomba de velocidade variável/controlador montado na parede/válvula de 2 vias
> Operação do motor de indução ineficiente
> Bomba selecionada para o ponto de projeto
> Sensor localizado na carga remota
> Mantém a pressão na zona remota
> Sem economia se o sensor parar de funcionar
bomba de velocidade variável controladormontado na parede/válvula de 2 vias
> Sensor na sala de máquinas
> Manutenção constante da altura piezométrica do projeto
> Sem economia se o sensor parar de funcionar
até
80%+ economia de energiadesign envelope geração 5 (1–10 hp) > Controles digitais
avançados> Controle ajustado para o
motor específico> Motor iecm: Classificação
de eficiência ie5> Hidráulica avançada
pens
ando
um
ní
vel
acim
a
> Compartilhamento de carga em múltiplas bombas
> Preparação com a melhor eficiência (con-trole de bombas paralelo sensorless)
> Diagnósticos e tendên-cias incorporadas
> Gerenciamento de de-sempenho em tempo real
carga
carga
carga
carga
chiller
altura do edifício
válvulas de controle de duas vias
sensorexterno tradicional
t
t
t
t
t tt
controles
Em um sistema de água gelada, os controles de temperatura de um edifício influenciam o vazão local das válvulas de
controle que modulam o vazão para as serpentina de refrigeração (carga). Conforme as válvulas de controle abrem para uma maior vazão de água gela-da, a pressão diferencial através da válvula diminui.
O controlador reage a essa alteração aumentando a velocidade da bomba. Se as válvulas de controle são fechadas para reduzir a vazão de água gelada, a pressão diferencial através da válvula aumenta e o controlador reduz a velocidade da bomba.
Equipado com technologiasensorless, as soluções Design Envelope não exigem um sensor externo para monitorar e controlar a carga do hvac.
o sensor internoo sensor interno
c
b
a
no. revision date
tolerances
decimals
2 places .010
3 places .005s.a. armstrong limited
scarborough canada
used on: name of part
numberdrawn by date
checked scale
num
ber
5.25 6.50
drill and tap4 sets of 2holes through1/4"x20unc
'a' b
ore
6.12
dia
.
7.00
55
'a'
'a'
(8) holes .687 dia. drill thruequally spaced on 8.031 p.c.d.straddling centres.
9.12
dia
. (re
f.)
0.06 7.00
40 d
ia.
1.37
0.87
0.31
.002-a-
125
125
2.198
0.56
2.188
.703 drill x 1.75 deeptap .50 npt (1) hole
.015 x 45°chamfer
.002a-b-
b .002
125
ref.
(4) holes .437 dia. drill thruequally spaced on 5.875 p.c.d.straddling centres.
'b'
(4) holes drill .312 dia. x .75 deeptap .375-16unc x .56 deep equallyspaced on 3.280 p.c.d. straddlingcenters.
0.31
.25 dia. drill thru
.437 dia. drill x .50 deeptap .25 npt- (1) hole.(for groups 012, 032, 042,
datu
m
r0.03
.03 x 45°chamfer0.28
9.50
clean up ifnecessary
45°
(4) holes .437 dia. drill thru equallyspaced on 5.118 p.c.d. straddling centres(for groups 511 512 531 532 541 and
512, 532, 542 only)
542 only-d-
f 0.002 d
como funciona
Equipada com a tecnologia sensorless, a curva característica de desempenho da bomba Design Envelope (consumo de
energia e rpm) e a curva de operação, são pré-pro-gramadas no controlador. Durante a operação, o controlador monitora a potência e a velocidade da bomba e estabelece o desempenho hidráulico e a posição da condição de vazão-pressão da bomba
em relação às exigências do sistema. À medida que as válvulas de controle do prédio abrem ou fecham para regular a vazão nas serpentinas de resfriamen-to e mantêm o conforto dos ocupantes do prédio, o controlador sensorless ajusta automaticamente a velocidade da bomba para alcançar a vazão e a pressão exigidos pelo sistema.
monitoramento depotência e velocidade mapa do
programa
controlandopressão e vazão
(P1 ,S1)=(H1 ,F1)
(P2 ,S2)=(H2 ,F2)
monitora potência e velocidade
controla pressãoe vazão
monitora potência e velocidade
controla pressãoe vazão
como funciona
S.A. ARMSTRONG LIMITED
B
A
1
NO. REVISION DATE
TOLERANCES
DECIMALS
2 PLACES .010
3 PLACES .005 SCARBOROUGH CANADA
USED ON: NAME OF PART
NUMBERDRAWN BY DATE
CHECKED SCALE
NU
MBE
R
a
A
A
a
a
chamfer .06 x 45°both ends
dia
.002b .002b
.001
b
0.5050.510
1.624
1.625
dia
.003b
.09 saw cut
section a - a
NOTES UNLESS OTHERWISE SPECIFIED1 MACHINE FINISH: BORE 63 OTHER SURFACES 125
2 BREAK ALL SHARP CORNERS 1/64 & REMOVE ALL BURRS3 INSIDE CORNER RADII 1/64 MAX.4 FRACTIONAL DIMENSIONS TOLERANCE ±1/645 MAKE FROM P/N 991254-300 3.5" DIA STRESS RELIEVED HIGH TENSILE ALUMINUM ROD-6061-T6511
COUPLING - SPLIT1.625X1.625 DIA SHAFTS, 2.75 GAP
4300 SERIES284TSC, 286TSC MOTORS
427735-00010/8/96
FULL
D.C.
4277
35-0
00
1.250
0.37
90.
377
b .001
3.900
dia.
(6) p
lace
s..7
5
2.54
02.
530
5.250
scri
be m
ark
1.085
0.980
1.680
0.750
3.4483.452dia
1.190
0.7360.741
2.380ctrs 4.742
6.243
7.68
0.3800.385
2.03
02.
035d
ia
b .005
.001
b
4.305
GROOVE ADDED AT PUMP END 3/11/97
2.500
0.37
70.
379
ECO 9156 G.L. JAN.21 2003
ref.
ref.
vivendo o
O Gerenciador de Bomba é um serviço de gerenciamento de desempenho que ajuda os operadores a manter uma eficiência otimizada de longo prazo.
desempenho ampliado
custo de instalação mais baixo até 65% de economia em comparação com as soluções padrões do setor
custo de operação mais baixo até 80% de economia em comparação com as soluções padrões do setor
menor risco Menor ocupação de espaço
Peso geral reduzido
Menos componentes de conexão
Custo de mão de obra reduzido
Comissionamento automático para a máxima eficiência imediata
Custos de manutenção mais baixos em qualquer configuração de bombeamentoDesempenho de alta eficiência ampliado
Máxima confiabilidade
Máxima flexibilidade
Redundância gerenciada sem operante/reserva
A maioria dos sistemas de controle de múltiplas bombas preparam as bombas com base na capacidade. A lógica de controle do pspc utiliza
um mapeamento das curvas de eficiência da bomba para determinar a melhor combinação possível de bombas e velocidades de operação para qualquer exigência de vazão.
Quando o pspc calcula que um arranjo de bombas iria operar com mais eficiência com mais uma bomba adicionada ao conjunto atual de bombas em operação, a lógica de controle liga mais uma bomba e coordena as velocidades de operação de todas as bombas de operação, para compartilhar a carga.
Controle de bomba paralelo sensorless é uma tecnologia que minimiza os
custos de energia da instalação de múltiplas bombas, utilizando estagios
na melhor eficiencia.
> Detecção antecipada de alterações na condição da bomba
> Notificação de alterações nas configurações de equipamentos
> Visão do status, desempenho e eficiência da bomba
> Vida útil estendida e ótimo desempenho com as configurações Tango e dualArm
vivendo o
NOTE:1. THE SECTION VIEW A-A IS ROTATED 90 ° CW.2. EPDM 1 TO BE VULCANIZED OVER STAINLESS STEEL INSERT 2 .3. EPDM ELASTOMER HARDNESS TO BE 70-DUROMETER TO ASTM D14154. MACHINING TOLERANCES APPLY TO THE ENTIRE DRAWING
a
c
D
e
6 5 4 1
MICROINCHES
INCHStandard
N/A4302, 4382 DUAL ARM PUMPS
GD&T to follow ASME14.5 R2009
6/21/20116/20/2011
IniIniIniGLSD
1 of 20.038220
--
1:1
B 428493-003
3rd ANGLE PROJECTION
TITLE:
REV:DRAWING NO:SIZE:
SHEET:MASS [kg]:SCALE:
COMMENTS:ENG APPMFG APPQ.A.
CHECKDRAWN
DATENAME
USED ON:
STANDARD:SURFACE FINISH:
UNITS OF MEASUREMENT:
CAVITY NUMBER TO BE AGREED ANDIDENTIFIED ON MULTICAVITY TOOLS
ANGULAR TOLERANCE:X ° ±.5 °X.X ° ±.1 °
MACHINING TOLERANCE:X.X ±.0310 [0.762]X.XX ±.0100 [0.254]X.XXX ±.0050 [0.127]X.XXXX ±.0005 [0.0127]
UNLESS OTHERWISE SPECIFIED:
The information contained inthis drawing is the sole propertyof S.A. Armstrong Ltd. Anyreproduction in part or wholewithout written permission ofS.A. Armstrong Ltd. isprohibited.
4284
93-0
03pa
rt n
o:
3IN. DUAL ARM VALVE SEAT
MASS [kg(lb)] DIMMENSIONMATERIALPOSITIONPART №
ECO № DATE APPROVEDREVISION23
5 1346 2
b
C
A
d
E
B
CASTING TOLERANCE:0 � 3 [0 � 76.2] ±.031 [±0.79]3 � 7 [76.2 � 177.8] +.094, -.063 [+2.38, -1.58]7 � 20 [177.8 � 508] +.125, -.063 [+3.17, -1.58]20 � 100 [508 � 2540] ±.125 [±3.17]
-- ECO 9639 11-06-21 GL
428493-003 2 ASTM D1418 EPDM 0.011(0.026) 3.587X2.300X.290428493-103 1 SST AISI-304 16GA 0.027(0.058) 3.587X2.300X.0625
2x r.175
r1.510
.254
r1.720
k .002 a b
k .004
u .002
u .004
j n .002 a b
b .002 a
a
a ab
5.0°
20.0° 25.0°
1.400
2.500
3.400
.106
.620
r.33r.33
2.173
.400
2x r.100 ±.005
.32
1.700
.187
k .002
k .002
u .002
u .004
b
b
1 2
2x r.280
r1.565
2.500
1.700
3.400
2x r.390
r1.900
r1.400
r1.720 j n .002 a b
2.300
section a-ascale 2 : 1
dc
.260.170
.130
.054
.054
.063
detail dscale 4 : 1
2
1
c .002
c .002
.254
75°
.040
.046
r.020
.210
.040
.290.085
.085.145
.040r.020
.240
.046
105°
detail cscale 4 : 1
j .002 a
j .002 a
.063
section b-b
c .005
c .005
A Armstrong reinventou e redesenhou as soluções de bombeamento para incluir serviços de gerenciamento de desempenho e conectividade. As bombas Design Envelope fornecem a eficiência ideal através de:
Opções e gama de desempenho expandida
Balanceamento automático de vazão com um toque
Modulação de velocidade da bomba com base em uma curva de controle quadrática ajustável para a melhor eficiência com carga parcial
Precisão na medição da vazão (+/- 5%)
Dados e diagnósticos incorporados para fornecer notificações e informações de desempenho
pacotes de desempenho
funções incluídas
Conjunto sensorless (padrão)
• Controlesensorless• Leituradevazão• Vazãoconstante• Pressãoconstante
Sensorless paralelo(padrão na Tango e na dualArm)
• Controlesensorless paralelo
Conjunto performance de energia
• Balanceamentoautomaticoda vazão
• Controledevazãomaxima
Conjunto de \proteção
• Controledevazãomínima• Controledaválvulade
by-pass
Otimização de zona• Sinaisdecontroledesen-
sores de pressão diferencial
Configuração de dupla estação
• Predefiniçãodosparâ-metros de aquecimento e refrigeração para sistemas de duas tubulações
conectividadeO recurso de Wi-Fi incorporado suporta o controle remoto, o monitoramento em tempo real e o gerenciamento para custos de operação mais baixos
Acesso local e remoto a partir de qualquer dispositivo inteligente
Software adaptado para navegador e interface de usuário intuitiva
desempenho
gerenciador de bomba
Inteligência estendida: o controlador integrado fornece diagnósticos internos,, tendências, alertas, balanceamento de vazão automático e opcionalmente controle de bomba paralelo sensorless
Controles avançados: tela colorida de toque com ihm intuitiva e acesso em tempo real do desempenho e condições da bomba
Conectividade em tempo real:asopçõesincluemBACnet,BACnetIPeModbus. O Wi-Fi incorporado e a conectividade com fio suporta o controle local ou o controle baseado na Web a partir de uma unidade portátil
Motores inteligentes da Armstrong: com controles integrados fornecem níveis ie5 de eficiência energética (em modelos selecionados) e o menor consumo de energia
proprietários de edifício• Menorescustosdeoperaçãoaolongodavidadasbombas• Forneceumagarantiadecapacidadeadicionalparafuturasalterações
nas cargas do edifício• Incomparáveiseconomiasdeespaço,eficiênciaeredundânciacomas
configurações de múltiplas bombas Tango e dualArm
projetistas • Amplagamadeindicaçõesdedesempenhoparaiteraçõesreduzidas
de seleção de bomba e risco de desempenho reduzido• Certificação ul std 778 e csa std c22.2 N°.108
instaladores• Fácilinstalaçãoecomissionamento• Modelosexpressosdisponíveisparaentregarápida• Fonteúnicaderesponsabilidadeparatodososaspectosdeuma
solução de bombeamento integrada
líder do setor
o mais baixo risco de operação
e projeto
o mais baixo custo ambiental
o mais baixocusto de
instalação
o mais baixo custo de operação
a mais alta eficiência de energia
A tecnologia Design Envelope oferece o gerenciamento avançado do desempenho do hvac, o comissionamento mais simples e rápido e um desempenho de vida útil otimizado através de ações e visões em tempo real.
recursos
valor
interno externo
1 hp–10 hp 1–10 hp
Modelos expressos disponíveis
interno externo
1–100 hp 1–100 hp
interno externo
1–40 hp 1–40 hp
interno externo
1–7½ hp 1–7½ hp
interno externo
1 hp–450 hp 1–125 hp
Independente 450 hp–1250 hp
Modelos expressos disponíveis
interno externo
1–10 hp 1–10 hp
Modelos expressos disponíveis
interno externo
1–125 hp n/d
Modelos expressos disponíveis
interno externo
1–7½ hp n/d
Modelos expressos disponíveis
• Classificada para ul type 4x com motor padrão tefc.
• Proteçãodoseletrônicosdocontroladorcomepóxiparaprotegercontraacondensação.
• Contraplaca em aço inoxidável previne a corrosão entre a contraplaca e o dissipador térmico.
• Proteçãosuperiorcontraintempériesprotege o teclado de raios uv e evita o aquecimento excessivo devido exposição do sol, e evita o acúmulo de gelo nas áreas sensíveis.
linha de bombas design envelope*líder do setor
4302dualArm com acoplamento
dividido
4312Twin com
acoplamento dividido
4322/4372Tango com
acoplamento fechado e dividido
4392Twin com
acoplamento fechado
4300Vertical alinhada
com acoplamento dividido
4380Vertical alinhada
com acoplamento fechado
4200hSucção axial com
acoplamento dividido
4280Sucção axial com
acoplamento fechado
* Monofásica disponível para 7½ hp / 5½kW
aplicações externas
Entre em contato conosco em: +1 416 755 2291ArmstrongFluidTechnology.com/DE
1 hp 450 hp
Veja as suas economias e roi utilizando dados reais da sua instalação. Pergunte a um re-presentante da Amrstrong.
tm
a r m s t r o n g f lu i dt ec h n o lo g y. co ma r m s t r o n g f lu i d t ec h n o lo g y fundada em 1934
b u f f a l o
t o r o n t o
m a n c h e s t e r
b a n g a l o r e
x a n g a i
s ã o p a u l o
#59, first floor, 3rd mainmargosa road, malleswarambangalore, india560 003+91 (0) 80 4906 3555
wolverton streetmanchesterunited kingdomm11 2et+44 (0) 8444 145 145
93 east avenuenorth tonawanda, new yorku.s.a.14120-6594+1 716 693 8813
23 bertrand avenuetoronto, ontariocanadam1l 2p3+1 416 755 2291
no. 1619 hu hang road, xi du townshipfeng xian district, shanghaip.r.c.201401+86 21 3756 6696
rua josé semião rodrigues agostinho, 1370 galpão 6embu das artessão paulo, brasil+55 11 4781 5500
b i r m i n g h a mheywood wharf, mucklow hillhalesowen, west midlandsunited kingdomb62 8dj+44 (0) 8444 145 145