bosch pir ir 200 lsn

4
Intrusion Systems | IR 200 LSN Infrared Motion Detector The IR 200 LSN infrared motion detector is used to monitor rooms for unauthorized entry. PIR motion detector, 15 m wide-angle version. 25 m long- range version with long-range mirror (optional). Functions A dual, differentially-connected pyroelectric sensor is positioned at the focal point of a mirror. Depending upon the particular construction of the mirror, this results in a fine-mesh, grid-like (IR 200 LSN) monitoring area, or a comprehensive, wall-like (IR 200 LSN with IRS 162) monitoring area. Temperature The detector uses the temperature of surrounding surfaces, such as floors and walls, as the reference value. The detector is configured for optimum sensitivity and false alarm suppression. However, high temperature fluctuations on the reference surfaces should be avoided. Sensitivity adjustments The sensitivity can be set at 3 levels using the DIP switch: the sensitivity setting "high value" must not be used in rooms with wall lengths of less than 5 m. High values – increased detection requirements Default – living room, office Raw environment – premises with significant disturbances Detector displays The detector has a walk test indicator that, when the walk test is activated, blinks for approx. 3 seconds each time the alarm is triggered. The detector is not equipped with an alarm log display. Due to the individual detector identification by the LSN control panel, this is no longer necessary. Certifications and Approvals Region Certification Germany VdS G 101531, B IR 200 LSN (W) G 101532, B IR 200 LSN (V) Europe CE IR 200 LSN Installation/Configuration Notes IR 200 LSN detectors do not mutually influence each other. If multiple detectors are used for wall-to-wall monitoring, the detection zones can overlap. Fixed objects represent surfaces that reduce the detection zone. IR 200 LSN Infrared Motion Detector Wide-angle version (standard) up to 15 m Long-range version (optional) up to 25 m Temperature compensation Configuration of the detector is done by programming software in the corresponding LSN control panel. Alarm, tampering and faults are evaluated via the LSN bus. 2-wire connection to LSN www.boschsecurity.com

Upload: melody-cotton

Post on 09-Dec-2015

227 views

Category:

Documents


4 download

DESCRIPTION

PIR BOSCH

TRANSCRIPT

Page 1: Bosch Pir Ir 200 Lsn

Intrusion Systems | IR 200 LSN Infrared Motion Detector

The IR 200 LSN infrared motion detector is used to monitorrooms for unauthorized entry.

PIR motion detector, 15 m wide-angle version. 25 m long-range version with long-range mirror (optional).

Functions

A dual, differentially-connected pyroelectric sensor ispositioned at the focal point of a mirror. Depending uponthe particular construction of the mirror, this results in afine-mesh, grid-like (IR 200 LSN) monitoring area, or acomprehensive, wall-like (IR 200 LSN with IRS 162)monitoring area.

TemperatureThe detector uses the temperature of surrounding surfaces,such as floors and walls, as the reference value. Thedetector is configured for optimum sensitivity and falsealarm suppression. However, high temperature fluctuationson the reference surfaces should be avoided.

Sensitivity adjustmentsThe sensitivity can be set at 3 levels using the DIP switch:the sensitivity setting "high value" must not be used inrooms with wall lengths of less than 5 m.

High values – increased detection requirements

Default – living room, office

Raw environment – premises with significant disturbances

Detector displaysThe detector has a walk test indicator that, when the walktest is activated, blinks for approx. 3 seconds each time thealarm is triggered.

The detector is not equipped with an alarm log display. Dueto the individual detector identification by the LSN controlpanel, this is no longer necessary.

Certifications and Approvals

Region Certification

Germany VdS G 101531, B IR 200 LSN (W)

G 101532, B IR 200 LSN (V)

Europe CE IR 200 LSN

Installation/Configuration Notes

IR 200 LSN detectors do not mutually influence each other.If multiple detectors are used for wall-to-wall monitoring,the detection zones can overlap.

Fixed objects represent surfaces that reduce the detectionzone.

IR 200 LSN Infrared Motion Detector▶ Wide-angle version (standard) up to 15 m

▶ Long-range version (optional) up to 25 m

▶ Temperature compensation

▶ Configuration of the detector is done by programmingsoftware in the corresponding LSN control panel.

▶ Alarm, tampering and faults are evaluated via the LSNbus.

▶ 2-wire connection to LSN

www.boschsecurity.com

Page 2: Bosch Pir Ir 200 Lsn

2 | IR 200 LSN Infrared Motion Detector

Outside the monitoring area, ceilings and walls should bemechanically stable.

In order to ensure the intrusion security of ceilings that arenot mechanically stable, detectors should monitor eachother.

The HIGH response sensitivity cannot be used in roomswhose sides are less than 5 m long.

Moving objects within the detection zone are not permitted.

If placed above a heating radiator, a minimum distance of1.5 m to the radiator is necessary.

Heat sources within the detection zone cause faults.

InstallationShielded installation cable must be used to connect thedetector.

The detector reacts best to movement at right angles to thedetection zones.

After initial set-up of the detector in an LSN cluster, wait atleast one minute until the detector is operationally ready.

The installation bracket (optional) can be used to swivel thedetector around by +/-45° and to tilt it by +10°/-15° (notVdS compliant!).

Note Do not remove the circuit board in thedetector. Risk of damage!

Installation height

1,6

1,9

2,2

2,5

2,8

m

7 11 13 15 m Y

B

A

5,5 7 8,5 10 11,5 m x

A B

Y Range y: central long-range zone

X Range x: lateral long-range zone

Wide-angle version• Greatest possible monitoring density by closely-spaced

chessboard-type mirror with 16 zones and a 15 m range.• In the case of perpendicular (standard) installation, the

inclination of the central long-range zone is 5.5°, therange is 15 m, and the lateral long-range zone is 12 m.

• In the case of installation with a 3° incline, the laterallong-range zone is inclined to 8.5°, the range 13 m, andthe lateral long-range zone is 11 m. This means the zoneconfiguration can be adjusted to match the spatialconditions.

Side view

0 5 15 m

2,2m

39 21

10

5,5

10

Plan view

Y

X

85°

12 m

X: range of the lateral long-range zoneY: range of the central long-range zone

Long-range version with IRS 162 (optional)• Long-range version by changing the IRS 162 long-range

mirror (optional)• 11 zones give a closed, long-range detection zone of up

to 25 m• Monitoring area cannot be bypassed due to overlapping

operating zone distribution

IR 200 LSN

10m 20m 25m

1,25m1,0m0,5m0,0m

+ IRS 162

15m

1

1 Non-monitored surface

Page 3: Bosch Pir Ir 200 Lsn

IR 200 LSN Infrared Motion Detector | 3

2,2m

25m

2,2m

0,4m 1,4m

25m

4,0m

4m

0,75m1,5m

1 1

2 2

3 3

4

1 Installation height

2 Side view

3 Top view

4 The distance from the side to the wall depends on the range

The detector requires a stable reference for the entiredetection zone. The detection zone consists of twosubzones (separated by the central level). The subzonescannot be referenced to different surfaces that may consistof differing materials. The middle level of a detection zoneis in the detector's longitudinal axis, which is perpendicularto the installation surface (housing floor).

Not permissible:

1

2

3

4

44

Permissible:

21

3

4

4

4

1 Material A

2 Material B

3 Outside wall

4 Inside wall

Parts Included

Type Qty. Component

IR 200 LSN 1 Infrared motion detector

Technical Specifications

LSN operating voltage Max. 33 V

LSN current consumption Approx. 4.15 mA

Movement speeds

• Wide-angle mirror 0.2 to 3.0 m/s

• Long-range mirror 0.2 to 4.0 m/s

Environmental conditions

• Operating temperature -20 °C to +55 °C

• Storage temperature -20 °C to +60 °C

• Humidity (EN60721) <95% relative humidity, no dew point

Dimensions (H x W x D) 135.5 x 55 x 45 mm

Housing protection category(EN60529, EN50102)

IP41/IK02

VdS environmental class II

Ordering Information

IR 200 LSN Infrared Motion DetectorFor monitoring rooms for unauthorized entry,15 m wide-angle version, 25 m long-range ver-sion with long-range mirror (optional)

4998085570

www.boschsecurity.com

Page 4: Bosch Pir Ir 200 Lsn

4 | IR 200 LSN Infrared Motion Detector

Americas:Bosch Security Systems, Inc.130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 [email protected]

Europe, Middle East, Africa:Bosch Security Systems B.V.P.O. Box 800025600 JB Eindhoven, The NetherlandsPhone: + 31 40 2577 284Fax: +31 40 2577 [email protected]

Asia-Pacific:Robert Bosch (SEA) Pte Ltd, Security Systems11 Bishan Street 21Singapore 573943Phone: +65 6258 5511Fax: +65 6571 [email protected]

Represented by

© Bosch Security Systems Inc. 2010 | Data subject to change without noticeT339142667 | Cur: en-US, V14, 2 Jul 2010 | Src: de-DE, V0, 7 Jul 2008