bp ampscomparison
TRANSCRIPT
![Page 1: BP AmpsComparison](https://reader035.vdocument.in/reader035/viewer/2022073018/55cf9bf8550346d033a80d12/html5/thumbnails/1.jpg)
BrainAmp seriesBrainAmp Standard BrainAmp DC BrainAmp ExG
Number of Channels per Unit 32 32 8/16
Max. Number of Channels 256 256 -
Channel Type / Referencereferential channels /recording with one electrode as reference (unipolar)
referential channels /recording with one electrode as reference (unipolar)
>> BrainAmp ExG 8: 8 bipolar (sensors cannot be connected!)
>> BrainAmp ExG 16: 16 bipolar OR 8 bipolar + 8 AUX (to connect sensors)
Integrated Impedance Measurement yes, including reference and ground electrode
yes, including reference and ground electrode
yes
Device suitable for MRI scanner room No No No
Input Impedance for DC [MT] 10 switchable: 10 / 10000 switchable: 10 / 200000
Input Noise [µVpp] M 2 M 1 M 2
CMR [dB] N 90 N 110 N 100
High Pass [Hz] 0.016 (10 s)0 in DC mode, 0.016 (10s) in AC mode,AC or DC software switchable
0 in DC mode, 0.016 (10s) in AC mode,AC or DC software switchable
Low Pass [Hz] 10001000 / 250 (switchable for resolutions 0.1 μV / 0.5 μV per bit)
1000 / 250 (switchable for resolutions 0.1 μV / 0.5 μV per bit)
Operating Range [mV] ± 3.28switchable: ±3.28; ±16.384; ±327.68
switchable: ±3.28; ±16.384; ±327.68
Resolution [µV] 0.1 per bit switchable: 0.1; 0.5; 10 per bit switchable: 0.1; 0.5; 10 per bit
Sampling Rate [kHz] 5 per channel 5 per channel 5 per channel
A/D-Conversion [bit] 16 16 16
DC Offset Compatibility [mV] ± 300 ± 300 ± 300
Signal Transmission optical (via twin fiber optics) optical (via twin fiber optics) optical (via twin fiber optics)
Deblocking Function Yes Yes Yes
Blocking of unused Channels Yes Yes Yes
Power Supply
mains power adapter („PS6 wr V-0“): 100-240 Volt AC, 50/60 Hz) or rechargeable battery („PowerPack“)
mains power adapter („PS6 wr V-0“): 100-240 Volt AC, 50/60 Hz) or rechargeable battery („PowerPack“)
mains power adapter („PS6 wr V-0“): 100-240 Volt AC, 50/60 Hz) or rechargeable battery („PowerPack“)
Power Consumption [mA] M 150, typical 7 in standby M 150, typical 7 in standby M 150, typical 7 in standby
Computer Interface USB-Adapter (BUA, dualBUA) orPCI Adapter Card
USB-Adapter (BUA, dualBUA) orPCI Adapter Card
USB-Adapter (BUA, dualBUA) orPCI Adapter Card
TTL Trigger Input [bit] 16 16 16
Medical Device yes yes yes
Classification to MDD 93/42/EEC Class IIa Class IIa Class IIa
CE Mark CE 0535 CE 0535 CE 0535
Electrical Safety according to IEC 60601-1;EMC tested, electrically safe
according to IEC 60601-1;EMC tested, electrically safe
according to IEC 60601-1;EMC tested, electrically safe
Device Protection Class II II II
Patient Safety (IEC 60601-1) applied part of type BF applied part of type BF applied part of type BF
Dimensions H x W x D [mm] 68 x 160 x 187 68 x 160 x 187 68 x 160 x 187
Weight [kg] 1.1 1.1 1.1
Contact us at:Tel. +49 (0) 8105 733 84 0 or [email protected]
At a glance: Brain Products Amplifiers in Comparison (page 1 of 4)
Content created by Marketing Version .019 09/2012
![Page 2: BP AmpsComparison](https://reader035.vdocument.in/reader035/viewer/2022073018/55cf9bf8550346d033a80d12/html5/thumbnails/2.jpg)
actiCHamp (compared to BrainAmp Standard and DC)
At a glance: Brain Products Amplifiers in Comparison (page 2 of 4)
actiCHamp BrainAmp Standard BrainAmp DC
Number of (EEG) Channels per Unit 32 32 32
Max. Number of Channels 160 + 8 AUX 256 256
Channel Type / Reference
EEG channels: referential channels / internal Reference
AUX channels: bipolar, -4.8 V - 4.8 V
referential channels /recording with one electrode as reference (unipolar)
referential channels /recording with one electrode as reference (unipolar)
Integrated Impedance Measurement yesyes, including reference and ground electrode
yes, including reference and ground electrode
Device suitable for MRI scanner room No No No
Input Impedance for DC [MT] EEG: > 1000 AUX: > 40
10 switchable: 10 / 10000
Input Noise [µVpp] ≈ 2 (0.1 - 30 Hz) for EEG channels M 2 M 1
CMR [dB] > 100 N 90 N 110
High Pass [Hz] 0 (DC) 0.016 (10s)0 in DC mode, 0.016 (10s) in AC mode,AC or DC software switchable
Low Pass [Hz]EEG channels: 20000 or 8000 (depending on amp. version)AUX channels: 20000
10001000 / 250 (switchable for resolutions 0.1 μV / 0.5 μV per bit)
Resolution [µV] ≈ 0.048 per bit 0.1 per bit switchable: 0.1; 0.5; 10 per bit
Sampling Rate [kHz] in combination with BrainVision PyCorder (Python-based open source recording software)
16ch + 8 AUX: 100 32ch + 8 AUX: 50 64ch + 8 AUX: 25 96ch + 8 AUX: 10 128ch + 8 AUX: 10 160ch + 8 AUX: 10
combination not possible combination not possible
Sampling Rate [kHz] in combination with BrainVision Recorder 1.20 (commercial license)
16ch + 8 AUX: 100 32ch + 8 AUX: 100 64ch + 8 AUX: 50 96ch + 8 AUX: 25 128ch + 8 AUX: 25 160ch + 8 AUX: 25
5 per channel 5 per channel
A/D-Conversion / Digitization [bit] EEG and AUX channels: 24(one converter per channel)
16 16
Signal Transmission via USB 2.0 optical (via twin fiber optics) optical (via twin fiber optics)
Deblocking Function No Yes Yes
Power Supply rechargeable battery („actiPOWER“)
mains power adapter („PS6 wr V-0“): 100-240 Volt AC, 50/60 Hz) or rechargeable battery („PowerPack“)
mains power adapter („PS6 wr V-0“): 100-240 Volt AC, 50/60 Hz) or rechargeable battery („PowerPack“)
Computer Interface direct via USB 2.0USB-Adapter (BUA, dualBUA) orPCI Adapter Card
USB-Adapter (BUA, dualBUA) orPCI Adapter Card
TTL Trigger Input / Output [bit] 8 / 8 16 / - 16 / -
Medical Device no yes yes
Patient Safety (IEC 60601-1) acc. to IEC 60601-1, 3rd. Ed. applied part of type BF applied part of type BF
Device Protection Class II II II
Electrical Safety according to IEC 60601-1, 3rd. Ed.
according to IEC 60601-1;EMC tested, electrically safe
according to IEC 60601-1;EMC tested, electrically safe
CE Mark yes CE 0535 CE 0535
Dimensions H x W x D [mm] 68 x 160 x 187 68 x 160 x 187 68 x 160 x 187
Weight [kg] 1.1 1.1 1.1
Content created by Marketing Version .019 09/2012
The actiCHamp is intended to be used for research applications only and is not sold, designed or intended to be used as medical devices as defined in EU Directive 93/42/EEC, nor is it inten-ded to be used for other medical applications such as diagnosis or treatment of disease. The hardware is freely configurable. Brain Products shall not be liable for any use other than pure scientific and research applications. The actiCHamp hardware has been tested and certified as per the relevant EMC and electrical safety standards. A non-medical CE certificate is available on request.
![Page 3: BP AmpsComparison](https://reader035.vdocument.in/reader035/viewer/2022073018/55cf9bf8550346d033a80d12/html5/thumbnails/3.jpg)
At a glance: Brain Products Amplifiers in Comparison (page 3 of 4)
BrainAmp MR seriesBrainAmp MR BrainAmp MR plus BrainAmp ExG MR
Number of Channels per Unit 32 32 8 or 16
Max. Number of Channels 128 (for use in fMRI); 256 (for use in other application fields)
128 (for use in fMRI); 256 (for use in other application fields)
-
Channel Type / Referencereferential channels /recording with one electrode as reference (unipolar)
referential channels /recording with one electrode as reference (unipolar)
>> BrainAmp ExG MR 8: 8 bipolar (sensors cannot be connected!)
>> BrainAmp ExG MR 16: 16 bipolar OR 8 bipolar + 8 AUX (to connect sensors)
Integrated Impedance Measurement yes, including reference and ground electrode
yes, including reference and ground electrode
yes
Device suitable for MRI scanner room
yes
> SIEMENS/PHILIPS: 1.5 - 7 T > GE: 1.5 - 3 T > Bruker: 4 T
yes
> SIEMENS/PHILIPS: 1.5 - 7 T > GE: 1.5 - 3 T > Bruker: 4 T
yes
> SIEMENS/PHILIPS: 1.5 - 7 T > GE: 1.5 - 3 T > Bruker: 4 T
Input Impedance for DC [MT] 10 switchable: 10 / 10000 10
Input Noise [µVpp] M 1 M 1 M 2
CMR [dB] N 90 N 110 N 100
High Pass [Hz] 0.016 / AC0 in DC mode, 0.016 (10s) in AC mode,AC or DC software switchable
0 in DC mode, 0.016 (10s) in AC mode,AC or DC software switchable
Low Pass [Hz] 2501000 / 250 (switchable for resolutions 0.1 μV / 0.5 μV per bit)
1000 / 250 (switchable for resolutions 0.1 μV / 0.5 μV per bit)
Operating Range [mV] ± 16.384switchable: ±3.28; ±16.384; ±327.68
switchable: ±3.28; ±16.384; ±327.68
Resolution [µV] 0.5 per bit switchable: 0.1; 0.5; 10 per bit switchable: 0.1; 0.5; 10 per bit
Sampling Rate [kHz] 5 per channel 5 per channel 5 per channel
A/D-Conversion [bit] 16 16 16
DC Offset Compatibility [mV] ± 300 ± 300 ± 300
Signal Transmission optical (via twin fiber optics) optical (via twin fiber optics) optical (via twin fiber optics)
Deblocking Function Yes Yes Yes
Blocking of unused Channels Yes Yes Yes
Power Supply rechargeable battery („PowerPack“)
rechargeable battery („PowerPack“)
rechargeable battery („PowerPack“)
Power Consumption [mA] M 150, typical 7 in standby M 150, typical 7 in standby M 150, typical 7 in standby
PC Interface USB-Adapter (BUA, dualBUA) orPCI Adapter Card
USB-Adapter (BUA, dualBUA) orPCI Adapter Card
USB-Adapter (BUA, dualBUA) orPCI Adapter Card
TTL Trigger Input [bit] 16 16 16
Medical Device Yes Yes Yes
Classification to MDD 93/42/EEC Class IIa Class IIa Class IIa
CE Mark CE 0535 CE 0535 CE 0535
Electrical Safetly according to IEC 60601-1;EMC tested, electrically safe
according to IEC 60601-1;EMC tested, electrically safe
according to IEC 60601-1;EMC tested, electrically safe
Device Protection Class II II II
Patient Safety (IEC 60601-1) applied part of type BF applied part of type BF applied part of type BF
Dimensions H x W x D [mm] 68 x 160 x 187 68 x 160 x 187 68 x 160 x 187
Weight [kg] 1,1 1,1 1,1
Contact us at:Tel. +49 (0) 8105 733 84 0 or [email protected]
Content created by Marketing Version .019 09/2012
![Page 4: BP AmpsComparison](https://reader035.vdocument.in/reader035/viewer/2022073018/55cf9bf8550346d033a80d12/html5/thumbnails/4.jpg)
At a glance: Brain Products Amplifiers in Comparison (page 4 of 4)
* Using existing EEG files for teaching purposes with the BrainVision Analyzer Education or using the amplifier installed in the lab for training purposes, is the common procedure for out of the lab training sessions. We are offering the FirstAmp in combination with the Analyzer Education at a special low price. But it doesn‘t stop here! When you order a FirstAmp we will upgrade the number of licenses for your Analyzer Education to a total of 30, thus beating class size even in the most crowded environments! ** Versatility is the most distinctive feature of the Brain-Vision V-Amp. Favorably priced, the V-Amp is a valuable supplementation even for well-equipped laboratories. Biofeedback experiments, teaching courses as well as low budget projects will profit from the package including full BrainVision Recorder and Analyzer licenses shipped in a handy carrying box.
FirstAmp * / V-Amp **FirstAmp / V-Amp 8 channel V-Amp 16 channel
EEG Channels
Number of EEG Channels 8 plus Reference and Ground 16 plus Reference and Ground
Channel Type / Reference referential channels /recording with one electrode as reference (unipolar)
referential channels /recording with one electrode as reference (unipolar)
A/D-Conversion [µVpp] 24 24
Input Range [mV] ± 410 ± 410
Input Noise [µVpp] < 1 (0.5 - 30 Hz) < 1 (0.5 - 30 Hz)
Input Impedance to Ground for DC [MT] > 100 > 100
CMR 100 at 50 Hz 100 at 50 Hz
Sampling Rate [kHz] 2 2
Sampling Rate in High-Speed Mode (4 ch) [kHz] - 20
Resolution [µV / bit] ≈ 0.0489 ≈ 0.0489
Bandwidth [Hz] 0 (DC) - 500 (- 3 dB) 0 (DC) - 500 (- 3 dB)
Bandwidth in High-Speed Mode (4 ch) [Hz] - 0 (DC) - 4000 (- 3 dB)
AUX Channels
Number of AUX Channels 2 2
Channel Type bipolar bipolar
A/D-Conversion [µVpp] 24 24
Input Range [mV] ± 5 ± 5
Input Impedance to Ground for DC [MT] > 10 > 10
Differential Input Impedance for DC [MΩ] > 20 > 20
Sampling Rate [kHz] 2 2
Resolution [µV / bit] ≈ 1.19 ≈ 1.19
Bandwidth [Hz] 0 - 150 (- 3 dB) 0 - 150 (- 3 dB)
On-Board-Display TFT LCD 320 x 240 pixels; diagonal size of 3.5 inch
TFT LCD 320 x 240 pixels; diagonal size of 3.5 inch
No. of Trigger Inputs 9, TTL Level 9, TTL Level
Power Supply via USB via USB
Max. current in active mode during recording [mA] < 450, typical 370
Computer Interface USB 1.1 or higherfull speed mode with plug-and-play support
USB 1.1 or higherfull speed mode with plug-and-play support
Device suitable for MRI scanner room No No
Medical Device yes, conforms to MDD 93/42/EEC (and amended)
yes, conforms to MDD 93/42/EEC (and amended)
Patient Safety (IEC 60601-1) applied part of type BF applied part of type BF
Device Protection Class II II
CE Mark CE 0535 CE 0535
Dimensions H x W x D [mm] 170 x 125 x 30 170 x 125 x 30
Weight [kg] 0,400 0,430
Contact us at:Tel. +49 (0) 8105 733 84 0 or [email protected]
Content created by Marketing Version .019 09/2012