BPM Status. Pengjia Zhu 2013.9.11. 3.13. 3.14. 3.6. 3.9. 3.17. 3.27. 3.29. 2.5T 90 deg. 5T 6 deg. straight through. 2.5T 90 deg. septum fired. 2.5T 90 deg. 2.257GeV. 3.17 run 3273 raster size calibration. using 3.14 constant. BPM A. BPM B. BPM A constant works good. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/1.jpg)
1
BPM Status
Pengjia Zhu
2013.9.11
![Page 2: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/2.jpg)
2
3.13 3.14 3.173.9 3.273.6straightthrough
2.5T90 deg
2.5T90 deg
5T6 deg
septumfired
3.292.5T90 deg
2.257GeV3.17 run 3273 raster size calibration
BPM A BPM B
BPM B constant destroyed
using 3.14 constant
BPM A constant works good
![Page 3: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/3.jpg)
3
Reason:div changed from 4 to 2 for both BPM A and BPMB after 3176 run-> gain changed (auto gain, gain diff between + and - did not change)(I was thought the div will not change the position)
BPM A seems was not affected BPM B tragedy
![Page 4: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/4.jpg)
4
3.13 3.14 3.173.9 3.273.6
auto gain
straightthrough
2.5T90 deg
2.5T90 deg
5T6 deg
septumfired
3.292.5T90 deg
3.14 straight through harp scan
3.16 2.5T harp scan
timeline
3.16 harp scan have 3 runs with div=2 for BPM B (with target field)
Luckily...
BPMA BPMBharp 05
can use BPM A and harp05 to calibrate BPM B
![Page 5: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/5.jpg)
5
Unfortrantly...
survey uncertainty -> 0.25 mmBPMA resolution limit ~ 0.15mmBPMA,BPMB,Harp are close (941,814,677mm)three harp scans' pos too close ~ 1-3mm
The calibration failed
pos got from BPMA and harp05
BPM B data
![Page 6: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/6.jpg)
6
New method to calibrate BPM-- brute force calibration
![Page 7: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/7.jpg)
7
first step
beam position at targetgot from carbon hole~ 0.4mm uncertainty at target
BPMA
Reliable BPM A position
center position at BPM B
![Page 8: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/8.jpg)
8
packaged used: pyQT, matplotlib
ideal shaperadius and center position from BPMA and carbon hole
calibrated BPM B shape
only raster x turn on
only raster y turn on
sliders,manualy change constant
check if rotation changed
visually see the changes
![Page 9: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/9.jpg)
9
raw shape -- with 3/14 calibration constant
ideal shape
BPM B shape
only raster x turn on
only raster y turn on
check if rotation changed
![Page 10: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/10.jpg)
10
optimized
![Page 11: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/11.jpg)
11
3185 x position at target by using new constant
matched with Chao's fit result
![Page 12: BPM Status](https://reader035.vdocument.in/reader035/viewer/2022062723/56813f60550346895daa2ff2/html5/thumbnails/12.jpg)
12
Futher optimize:Use circle fit to get carbon hole center position instead of eyesParameter to judge if circlular?
Another job for beampackage:Optimized bpm calibration code, much faster