INSPECTION TYPE:
SAMPSONCOUNTY BRIDGE NUMBER 810101 INSPECTION CYCLE YRS
ROUTE ACROSS M.P.SR1256 BIG SWAMP CREEK 0
LOCATION 0.4 MI E.JCT SR1410
SUPERSTRUCTURE
SUBSTRUCTURE
RC FLOOR/TIMBER JOISTS (STD. BMD-10)
EBTS&IBTS:TIMBER CAPS/TIMBER PILES @ 8'CTS,CRUTCH BT@BT3
SPANS 1@17'9;1@17'1;1@17';1@16'10;1@17'11
LONGITUDE LATITUDE
PRESENT CONDITION INVENTORY RATING
INSPECTION DATE OPERATING RATING
PRESENT POSTING PROPOSED POSTING
COMPUTER UPDATE ANALYSIS DATE
POSTING LETTER DATE SUFFICIENCY RATING
OTHER SIGNS PRESENT
SIGN NOTICE ISSUED FOR
NUMBERED REQUIRED
WEIGHT LIMIT
DELINEATORS
NARROW BRIDGE
ONE LANE BRIDGE
LOW CLEARANCE
78° 34' 25.8" 34° 59' 44.4"
FAIR
SV 18 TTST 26
08/25/2010
No
No
No
No
No
LOOKING EAST
SV 18 TTST 26
Routine Inspection
2
BRIDGE INSPECTION REPORT
NC DEPARTMENT OF TRANSPORTATION
DIVISION OF HIGHWAYS
BRIDGE MANAGEMENT UNIT
ATTENTION PRIORITY MAINTENANCE ISSUED ON PILESSHORED STRUCTUREPILE REPAIRS: CONCRETE ENCASEMENTS
(1) STATE NAME -NORTH CAROLINA
(8) STRUCTURE NUMBER(FEDERAL)
INVENTORY ROUTE (ON/UNDER) - ON
(2) STATE HIGHWAY DEPARTMENT DISTRICT
(4) PLACE CODE
(6) FEATURE INTERSECTED -
(11)MILEPOINT
(16)LAT
(98)BORDER BRIDGE STATE CODE
(99)BORDER BRIDGE STRUCTURE NO
(43) STRUCTURE TYPE MAIN:
(44) STRUCTURE TYPE APPR :
(45) NUMBER OF SPANS IN MAIN UNIT
(46) NUMBER OF APPROACH SPANS
(107)DECK STRUCTURE TYPE -
TYPE -
(108)WEARING SURFACE / PROTECTIVE SYSTEM :
(A) TYPE OF WEARING SURFACE -
(B) TYPE OF MEMBRANE -
(C) TYPE OF DECK PROTECTION -
(27) YEAR BUILT
(28) LANES: ON STRUCTURE UNDER STRUCTURE
(29) AVERAGE DAILY TRAFFIC
(30) YEAR OF ADT (109) TRUCK ADT PCT
(19) BYPASS OR DETOUR LENGTH
UNDER -
(42) TYPE OF SERVICE : ON -
(106)YEAR RECONSTRUCTED
(3) COUNTY CODE
(9) LOCATION
(17)LONG
(7) FACILITY CARRIED
(48) LENGTH OF MAXIMUM SPAN
(49) STRUCTURE LENGTH
(50)CURB OR SIDEWALK: LEFT
(51) BRIDGE ROADWAY WIDTH CURB TO CURB
(52) DECK WIDTH OUT TO OUT
(32) APPROACH ROADWAY WIDTH (W/SHOULDERS)
(33) BRIDGE MEDIAN -
(34) SKEW (35) STRUCTURE FLARED
(10) INVENTORY ROUTE MIN VERT CLEAR
(47) INVENTORY ROUTE TOTAL HORIZ CLEAR
(53) MIN VERT CLEAR OVER BRIDGE RDWY
(54) MIN VERT UNDERCLEAR REF
(55) MIN LAT UNDERCLEAR RT REF
(56) MIN LAT UNDERCLEAR LT REF -
(38) NAVIGATION CONTROL -
(111)PIER PROTECTION -
(39) NAVIGATION VERTICAL CLEARANCE
(116)VERT - LIFT BRIDGE NAV MIN VERT CLEAR
(40) NAVIGATION HORIZONTAL CLEARANCE
SUFFICIENCY RATING =
STATUS =
(112)NBIS BRIDGE SYSTEM -
(104)HIGHWAY SYSTEM
(26) FUNCTIONAL CLASS -
(100)STRAHNET HIGHWAY -
(101)PARALLEL STRUCTURE -
(102)DIRECTION OF TRAFFIC -
(103)TEMPORARY STRUCTURE -
(110)DESIGNATED NATIONAL NETWORK -
(20) TOLL
(31) MAINTAIN -
(22) OWNER -
(37) HISTORICAL SIGNIFICANCE -
(58) DECK
(59) SUPERSTRUCTURE
(60) SUBSTRUCTURE
(61) CHANNEL & CHANNEL PROTECTION
(62) CULVERTS
(31) DESIGN LOAD
(64) OPERATING RATING -
(66) INVENTORY RATING -
(70) BRIDGE POSTING -
(41) STRUCTURE OPEN, POSTED ,OR CLOSED
DESCRIPTION -
(67) STRUCTURAL EVALUATION
(68) DECK GEOMETRY
(69) UNDERCLEARANCES,VERTI & HORIZ
(71) WATERWAY ADEQUACY
(72) APPROACH ROADWAY ALIGNMENT
(36) TRAFFIC SAFETY FEATURES
(113)SCOUR CRITICAL BRIDGES
(75) TYPE OF WORK -
(76) LENGTH OF STRUCTURE IMPROVEMENT
(94) BRIDGE IMPROVEMENT COST
(95) ROADWAY IMPROVEMENT COST
(96) TOTAL PROJECT COST
(97) YEAR OF IMPROVEMENT COST ESTIMATE
(114)FUTURE ADT (115) YEAR FUTURE ADT
(90) INSPECTION DATE
(92) CRITICAL FEATURE INSPECTION : (93) CFI DATE
A) FRACTURE CRIT DETAIL -
B) UNDERWATER INSP -
C) OTHER SPECIAL INSP
SCOUR
A)
B)
C)
810101BRIDGE
000000001630101
131012560
3
00000163
BIG SWAMP CREEK
SR1256
0.4 MI E.JCT SR1410
0
78° 34' 25.8"34° 59' 44.4"
TYPE - CODE
CODE
CODE
IDENTIFICATION
STRUCTURE TYPE AND MATERIAL
AGE AND SERVICE
GEOMETRIC DATA
RIGHT
NAVIGATION DATA
CODE
CODE
CLASSIFICATION CODE
CODECONDITION
CODELOAD RATING AND POSTING
CODEAPPRAISAL
PROPOSED IMPROVEMENTS
INSPECTIONS
Wood or Timber
Stringer Mutlibeam or Girder 702
5
Concrete cast-in-place CODE 1
CODE 1
CODE 0
CODE 0
Concrete
None
None
1962
Highway
Waterway 15
2
210
2005 6 %
4 MI
18 FT
87 FT
0.8 FT 0.8 FT
24.0 FT
25.3 FT
18.0 FT
0No Median
NO0°
99 FT 99 IN
24.0 FT
99 FT 99 IN
CODE
Not a Highway or Railroad
99.9 FT
0.0 FT
0
0
Not Applicable
No Navigational Control 0
Not a Highway or Railroad
33.7
Structurally Deficient
YES
0NON NHS Route
09Local
0Not a STRAHNET Route
No Parallel Structure N
2-way Traffic 2
Temporary T
Not Part of 0
On Free Road 3
State Highway Agency 01
State Highway Agency 01
Not Eligible 5
5
6
3
6
N
Other or Unknown 0
HS-1 201
HS-1 201
Posting Required 0
P
Posted for Load
2
5
N
7
8
0000
U
CODE 311
113 FT
$242,000
$61,000
$363,000
2007
420 2025
08/25/2010
NO
03/01/2010YES 48Mo
NO
PCT SHARE
SCOUR PLAN OF ACTION
NATIONAL BRIDGE INVENTORY-------- STRUCTURE INVENTORY AND APPRAISAL Run Date: 10/11/2010
3. RAILING
Routine InspectionINSPECTION TYPE
BRIDGE NO.
STRUCTURE TYPE
ROUTE ORIENTATION
COUNTY ROUTE
SPANS
OVERSAMPSON SR1256 BIG SWAMP CREEK810101
RC FLOOR/TIMBER JOISTS (STD. BMD-10)
W - E 1@17'9;1@17'1;1@17';1@16'10;1@17'11
EVALUATION CODE: 0-2 CRITICAL, 3 & 4 POOR, 5 & 6 FAIR, 7-9 GOOD
INSPECTION ITEM
DECK ITEMS GRADES
1. WEARING SURFACE
2. DECK NO. OF EA TYPE SPN GRADE RATES SI & A ITEM 58
a. CONCRETE
b. TIMBER
c. STEEL PLANK
d. OPEN GRID
a. CONCRETE
b. TIMBER
c. ALUMINUM
d. STEEL
4. CURBS, WHEELGUARDS, PARAPETS, MEDIANS
5. WALKWAYS (ON OR ATTACHED TO STRUCTURE)
6. DECK EXP JTS. OR DEVICES. NO. OF EACH
b. MISC PREFAB
a. STEEL PL OR FINGER
c. COMPRESSION SEAL
d. STANDARD JOINTS
e. OPEN JOINTS
7. DECK DEBRIS (INCLUDES EXCESS SAND/GRAVEL)
SUPER STR. (FM. 1 (90)B TRUSS) ITEM 59
10. LONGITUDINAL BEAMS OR GIRDERS
11. LONGITUDINAL JOIST OR STRINGERS
12. INT. DIAP'S, X-FRAMES, BRACING & CONN'S
13. END DIAP'S, CURTAIN WALLS, & CONN'S
14. FLOOR BEAMS AND CONNECTIONS
15. BEARING ASSEMBLIES (INCLUDING MISALIGN)
16. DRAINAGE SYSTEM (ON STRUCTURE)
17. MOVABLE SPAN MACHINERY
SUB STR. ITEMS. ITEM 60 (INCLUDE SCOUR)
35. TIM SUB STR.
36. CONC SUB STR.
37. STEEL SUB STR.
38. FOUNDATION PILES TYPE MATERIAL
39. SLOPE PROT., RIP-RAP (INCLUDE DRAINAGE)
40. FENDER SYSTEMS
41. DRIFT
a. ABUT. & INT. BENT CAPS & RISERS
b. PILES, POST, SILLS, & BRACING
c. BULKHEADS, WING'S, & TIE BACKS
a. ABUT. & INT. BENT CAPS
b. ABUT. & BENT COL'S BREASTWALLS
c. ABUT. & INT. BENT PILES
d. BACKWALLS, WING'S, RETAIN. WALLS
e. ABUT. & BENT FOOTINGS & SILLS
a. ABUT. & INT. BENT CAPS & RISERS
b. PILES, BRACING, AND BULKHEADS
ITEM 61
45. CHANNEL & CHANNEL PROT.
a. WATERWAY
b. ALIGNMENT
c. SCOUR
d. SLOPE PROT., RIP-RAP, DIKES, ETC.
50. APPROACH ROADWAY CONDITION
51. APPROACH SLABS
52. PAINT SYSTEM
53. UTILITIES
54. RESPONSE TO LIVE LOAD
55. ESTIMATED REMAINING LIFE
60. REGULATORY SIGN NOTICE ISSUED
61. PROMPT-ACTION NOTICE ISSUED
62. PRESENTLY POSTED
63. TOT. FIELD INSP TIME (INCLUDE WRITE UP)(MAN HR)
64. TOTAL SNOOPER INSP. TIME (HRS)
65. TOTAL TRAFFIC CONTROL TIME (MAN HRS)
70. SI&A GENERAL CONDITION RATINGS
ITEM 58
b. SUPERSTRUCTURE
c. SUBSTRUCTURE
d. CHANNEL & CHANNEL PROT.
a. DECK
ITEM 59
ITEM 60
ITEM 61
71. SI&A FIELD APPRAISAL RATINGS
a. WATERWAY ADAQUACY
b. APPR. RDWY. ALIGNMENT
72. FIELD SCOUR EVALUATION
USE OF INSP. ACCESSIBILITY EQUIPMENT
SNOOPER (CODE S, 4, OR N)
LADDER
BUCKET TRUCK
BOAT
OTHER
SPECIAL INSPECTION REQUESTED FOR
NOTE
80. INSPECTED BY:
81. REVIEWED BY:
CODE
55
6
7
1 5
6
6
7
4
6
5
5
6
7
6
6
7
7
6
7
8
YES
YES
8
0
0
5
6
5
6
7
8
O
NO
NO
NO
YES
NO
HRS
BRIDGE INSPECTION RECORD AND SUMMARYBRIDGE I & A FORM1 (90)A
2a 5 CONCRETE DECK 5SCALING WITH EXPOSED COARSE AGGREGATE AND POPOUTS 1/2 IN. DEEP IN ALL SPANS.SPAN 13 - 1/8 IN. TO 1/4 IN. LONGITUDINAL CRACKS THE FULL LENGTH OF SPAN.1/16 TO 1/8 IN. TRANSVERSE CRACKS AT 1 FT, 4 FT , 7 FT , AND 11 FT FROM END BENT 1.SPAN 23 - HAIRLINE TO 1/8 IN. LONGITUDINAL CRACKS THE FULL LENGTH OF SPAN.2 - HAIRLINE TO 1/16 IN. TRANSVERSE CRACKS AT 6 FT AND 9 FT FROM BENT 1.SPAN 31/8 IN. LONGITUDINAL CRACK NEAR CENTERLINE THE FULL LENGTH OF SPAN.SPAN 41 - 1/8 IN. LONGITUDINAL CRACK THE FULL LENGTH OF SPAN.HAIRLINE TO 1/32 IN. WIDE TRANSVERSE CRACKS AT 4 FT , 7 FT , AND 9 FT FROM BENT 3.SPAN 52 - 1/16 IN. LONGITUDINAL CRACKS FULL LENGTH OF SPAN.1/16 IN. TRANSVERSE CRACKS AT 1 FT , 4 FT , AND 8 FT FROM END BENT 2.
3a 6 CONCRETE RAILS 6SCALING WITH EXPOSED COARSE AGGREGATE IN FACES.LEFT SIDE RAIL HAS BEEN REPAIRED IN SPAN 1 , 2 , 3 , AND 4.
4 7 CURBS 7SCALING WITH EXPOSED COARSE AGGREGATE IN FACES.
6d 5 STANDARD JOINTS 5JOINTS ARE CRACKED AND LEAKING IN SPOTS.
7 6 DECK DEBRIS 61 IN DEEP DIRT AND DEBRIS OUT 1 FT.
11 6 LONGITUDINAL JOISTS 6JOIST 19 IS A REPLACEMENT IN ALL SPANS.RANDOM 1/16 IN. TO 1/8 IN. LONGITUDINAL CHECKS IN SIDES OF JOISTS.SPAN 4JOIST 1 SPAN 4 AT BENT 4 IS SPLIT OFF IN THE BOTTOM CORNER 1 1/2 IN. X 2 IN. HIGH X 26 IN. LONG.
16 4 DRAINAGE SYSTEM 4ALL OF THE DRAIN HOLES ARE CLOGGED.
35a 6 TIMBER CAPS 6CAPS AND CROWNSTRIPS AT END BENT 1, BENTS 1 - 4 ARE REPLACEMENTS.LONGITUDINAL CHECKS UP TO 1/8 IN. WIDE IN FACES.
Bridge I&A Form 1(82)H
State of North Carolina
Dept. of Transportation
Division of Highways
FIELD INSPECTION REPORT
Bridge Inspecion & Analysis
Team Leader
Assisted By
Item No. Grade
WILLIS C MAY
WTW
35b 5 TIMBER PILES 5PILE 3 END BENT 1 AND PILE 2 BENT 4 GRADE 4 ALL OTHERS GRADE 5.1/16 IN. VERTICAL CRACKS IN FACES.END BENT 1PILE 3 END BENT 1 IS DECAYED 12 IN. HIGH X 12 IN. WIDE X 3 IN. DEEP AT THE GROUND LINE . PRIORITY MAINTENANCE ISSUEDPILE 4 END BENT 1 HAS BEEN REPAIRED WITH A CONCRETE ENCASEMENT.BENT 1PILE 2 BENT 1 HAS BEEN SPLICED AND HAS A 2 FT. DIAMETER CONCRETE ENCASEMENT.BENT 2PILE 2 BENT 2 SPAN 3 SIDE IS DELAMINATED 8 IN. X 8 IN. X 1 IN. DEEP BELOW CROSS BRACE.BENT 3PILE 1 BENT 3 IS DECAYED AND BROKEN OFF AT WATERLINE. STEEL PILES WITH A CROSS CAP HAS BEEN PLACED 27 IN. FROM LEFT END OF CAP.BENT 4PILE 2 BENT 4 IS DECAYED IN THE LEFT SIDE NEAR WATERLINE 10 IN. HIGH X 8 IN. WIDE X 2 IN. DEEP. PRIORITY MAINTENANCE ISSUEDPILE 3 BENT 4 HAS BEEN REPAIRED AND HAS A CONCRETE ENCASEMENT.PILE 3 BENT 4 HAS A CONCRETE ENCASEMENT AND HAS A 1/4 IN. WIDE VERTICAL CRACK.
35c 5 TIMBER BULKHEADS, WINGWALLS 5END BENT 1VERTICAL BOARDS HAVE BEEN FACE NAILED TO END BENT 1 BULKHEAD BETWEEN PILE 2 & 3.BULKHEAD BOARD # 3 BELOW CAP IS DECAYED THROUGH IN SPOTS WITH EXPOSED FILL FROM PILE 3 TO RIGHT END.ENDS OF RIGHT SIDE WINGWALL BOARDS AT END BENT 1 ARE DECAYED BACK 6 IN. TO 12 IN.END BENT 2 RIGHT SIDE WINGWALL BOARD # 2 AT END BENT 2 IS DECAYED BACK 1 FT.
37a 6 STEEL CAPS 6THE STEEL CAPS HAVE AREAS OF RUST AND CORROSION AT THE EDGES AND AT THE WELDS.
37b 7 STEEL PILES 7STEEL PILES HAVE SPOTS OF CORROSIO IN THE EDGES.
41 6 DRIFT 6DRIFT BELOW WATERLINE SEE UNDERWATER REPORT.
45a 6 WATERWAY 6AQUATIC VEG IN WATERWAY.
Bridge I&A Form 1(82)H
State of North Carolina
Dept. of Transportation
Division of Highways
FIELD INSPECTION REPORT
Bridge Inspecion & Analysis
Team Leader
Assisted By
Item No. Grade
WILLIS C MAY
WTW
45b 7 CHANNEL ALIGNMENT 7SEE UNDERWATER REPORT.
50 6 APPROACH ROADWAY CONDITION 6BOTH APPROACHES ARE SETTLED UP TO 1 IN.PATCH IN APPROACH 2 AT END BENT 2.
62 YES SV 18 TTST 26
Bridge I&A Form 1(82)H
State of North Carolina
Dept. of Transportation
Division of Highways
FIELD INSPECTION REPORT
Bridge Inspecion & Analysis
Team Leader
Assisted By
Item No. Grade
WILLIS C MAY
WTW
2816 SY 140Asphalt Surface Repair or Replacement
APPROACHES ARE SETTLED UP TO 1 IN. AT END BENTS.
3310 LF 96Maintenance/Repair/Replacement of Standard Bridge Expansion Joints
JOINTS ARE CRACKED AND LEAKING IN SPOTS.
3326 SF 200Maintain Concrete Deck
CRACKS IN TOP OF DECK IN ALL SPANS.
3344 LF 5Repair / Replace Timber Substructure Components
PILE 2 BENT 4 IS DECAYED IN THE LEFT SIDE NEAR WATERLINE 10 IN. HIGH X 8 IN. WIDE X 2 IN. DEEP. SEE DRAWING
3344 LF 5Repair / Replace Timber Substructure Components
PILE 3 END BENT 1 IS DECAYED 12 IN. HIGH X 12 IN. WIDE X 3 IN. DEEP AT THE GROUND LINE . SEE DRAWING
3346 SF 40Repair / Maintain Timber Wings & Blkhds
DECAYED BULKHEAD AND WINGWALL BOARDS.
BRIDGE INSPECTOR'S RECOMMENDATION FOR MAINTENANCE REPAIRS
Bridge: 810101 County Date:
These Repairs Should Be Made Within Twelve Months From Date Of This Inspection
MMSCode
Description ofFunction
Unit Quantity Remarks Est.Cost
SAMPSON 08/25/2010
Priority Maintenance Level Not DeterminedPriority Maintenance Item Critical Finding Item
Key
MMS Code MMS Description Quantity
3344 Repair / Replace Timber Substructure Components 5
Submitted Date:
08/26/2010
Priority Level
Priority Maintenance
Status
Division Bridge Maintenance Notification Received
Location:
Pier Substructure Bent/Span No. 1 PILE 3 END BENT 1
Details
PILE 3 END BENT 1 IS DECAYED 12 IN. HIGH X 12 IN. WIDE X 3 IN. DEEP AT THE GROUND LINE . SEE DRAWING
LF
Submitted By:
WILLIS C MAY
Assisted By:
WAYNE T WILKINSON
MMS Code MMS Description Quantity
3344 Repair / Replace Timber Substructure Components 5
Submitted Date:
08/26/2010
Priority Level
Priority Maintenance
Status
Division Bridge Maintenance Notification Received
Location:
Pier Substructure Bent/Span No. 4 PILE 2 BENT 4
Details
PILE 2 BENT 4 IS DECAYED IN THE LEFT SIDE NEAR WATERLINE 10 IN. HIGH X 8 IN. WIDE X 2 IN. DEEP. SEE DRAWING
LF
Submitted By:
WILLIS C MAY
Assisted By:
WAYNE T WILKINSON
BRIDGE INSPECTOR'S RECOMMENDATION FOR PRIORITY MAINTENANCE REPAIRS
Bridge: 810101 County SAMPSON
THE FOLLOWING MAINTENANCE ITEMS HAVE BEEN SUBMITTED IN CONJUNCTION WITH A PRIORITY MAINTENANCE REQUEST
LONGITUDINAL AND TRANSVERSE CRACKING IN SPAN 1
TOP OF DECK SCALED WITH EXPOSED AGGREGATE
08/25/2010810101 County SAMPSON Date:Structure Condition Photos
LONGITUDINAL CRACK IN SPAN 3, SIMILAR IN SPAN 2, 4 & 5
TRANSVERSE CRACKING IN SPAN 5
08/25/2010810101 County SAMPSON Date:Structure Condition Photos
APPROACH 2 SETTLED AT END BENT 2
VERTICAL BOARDS FACE NAILED BETWEEN PILE 2 & 3 AT END BENT 1 BULKHEAD
08/25/2010810101 County SAMPSON Date:Structure Condition Photos
DELAMINATION IN PILE 2 AT BENT 2 SPAN 3 SIDE BELOW CROSSBRACE CONNECTION
DECAY IN THE LEFT SIDE OF PILE 2 AT BENT 4 (PRIORITY MAINTENANCE ISSUED)
08/25/2010810101 County SAMPSON Date:Structure Condition Photos
DECAY IN THE RIGHT SIDE OF PILE 3 AT END BENT 1 (PRIORITY MAINTENANCE ISSUED)
DECAY IN THE 3RD BULKHEAD BOARD FROM BOTTOM OF END BENT 1 CAP AND JUST TO THE LEFT OF PILE4
08/25/2010810101 County SAMPSON Date:Structure Condition Photos
COUNTY : DIV : DIST : STRUCTURE NUMBER : LENGTH :
ROUTE CARRIED : FEATURE INTERSECTED :
LOCATED : BRIDGE NAME :
FUNC. CLASS : SYST.ON : SYST.UNDER : ADT & YR : RAIL TYPE :
BUILT : BY : PROJ : FED.AID PROJ : DESIGN LOAD :
REHAB : BY : PROJ : ALIGNMENT : SKEW : LANES :
NAVIGATION : HT. CRN. TO BED : WATER DEPTH :
SUPERSTRUCTURE :
SUBSTRUCTURE :
SPANS :
BEAMS OR GIRDERS :
FLOOR : ENCROACHMENT : DECK (OUT TO OUT) :
CLEAR ROADWAY : BETWEEN RAILS : SIDEWALK OR CURB :
VERT.CL.OVER : VERT.CL.UNDER : HOR.CL.UNDER :
INV.RTG. : OPE.RTG. : CONTR.MEMBER : POSTED :
SYSTEM : GREEN LINE ROUTE :
2ND OPENING : 3RD OPENING : 4TH OPENING : 5TH OPENING :
REMARKS :
1962 BMU Other or Unknown
BMU TAN 90 2
09 NFA NFA 210 241
0.4 MI E.JCT SR1410
SR1256 BIG SWAMP CREEK
SAMPSON 3 2 810101 87
0.0 12 70.0FTVC HC FT FT
RC FLOOR/TIMBER JOISTS (STD. BMD-10)
EBTS&IBTS:TIMBER CAPS/TIMBER PILES @ 8'CTS,CRUTCH BT@BT3
1@17'9;1@17'1;1@17';1@16'10;1@17'11
19LINES 6X12 TIMBER JOIST @ VAR.CTS.
5 RC/NO AWS
25.3 FT
24.0 FT 25.4 FT 0.8 FT
99 FT 99 IN 00 FT 00 IN 0.0 FT
HS-1 HS-1 int.joist 18
Secondary S.R. Route N
ON UNDER
LT RT 0.8 FT
SV TTST 26 DATE 09/15/2008
241LT RT2005
FEET
FT
CITY :
BRIDGE MANAGEMENT UNIT
DATA ON EXISTING STRUCTURE Run Date: 10/11/2010
Structure Data Worksheet Spans
County: SAMPSON Structure No: 810101 Date: 08/25/2010 Inspected By: WCM
1 17.75 17.25
2 17.083 17.083
3 17 17
4 16.833 16.833
5 17.9167 17.33
Span NoSpan
LengthBearing to
Bearing Comments
Stream Bed Soundings(See next sheet for profile sketch)
Bridge No: County: Date: By:
Record sounding from top of rail. Other location if needed:
Distance from Highwater Mark to top of rail: Location of Highwater Mark:
810101 SAMPSON 08/25/2010 WCM
0 2.5 TOP OF WINGWALL
1 8.4 GROUND AT CAP 1 5.6 GROUND AT CAP
10 7.5
11 7.4
15 8.5 Water Surface/Water Edge (WSWE)
18 8.7 BENT 1 18 8.7 BENT 1
29 12.7
35 16.1 BENT 2 35 13.5 BENT 2
45 16.1
52 13.9 BENT 3 52 13.8 BENT 3
60 11.1
69 8.7 BENT 4 69 11.5 BENT 4
70 8.5 Water Surface/Water Edge (WSWE)
79 7.6
86 8.4 GROUND AT CAP 86 7.2 GROUND AT CAP
87 2.5 TOP OF WINGWALL
DOWNSTREAM UPSTREAM
Distance(Station) (ft)
Sounding(ft)
Description Distance(Station) (ft)
Sounding(ft)
Description
Top of Rail = 0 FT (Sounding)STREAMBED PROFILE (Downstream)
08/25/2010810101 County SAMPSON Date:Bridge:
LOOKING EAST
APPROACH 1
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
WEIGHT POSTING
JOINT AT END BENT 1
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
SPAN 1 OVERVIEW
JOINT AT BENT 1
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
SPAN 2 OVERVIEW
JOINT AT BENT 2
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
LOOKING SOUTH DOWNSTREAM
LOOKING NORTH UPSTREAM
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
SPAN 3 OVERVIEW
JOINT AT BENT 3
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
SPAN 4 OVERVIEW
JOINT AT BENT 4
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
SPAN 5 OVERVIEW
APPROACH 2
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
LOOKING WEST
SOUTH PROFILE
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
END BENT 2 OVERVIEW
CRUTCH PILES AT BENT 3 LEFT END OF CAP
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
NORTH PROFILE
BENT 2 SPAN 3 SIDE, OTHER BENTS SIMILAR
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
SUPERSTRUCTURE OVERVIEW
SUPERSTRUCTURE OVER END OF CAP
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
08/25/2010810101 County SAMPSON Date:Structure Structure Photos
END BENT 1 OVERVIEW